CORRECTION TO LICENSE AMENDMENT NO.

108 FACILITY OPERATING LICENSE NO.

DPR-33 DOCKET NO. 50-259 Remove the following page and replace with an identically numbered page.

255 84i0ii0016 8409iq

'PDR SDOCX 0S000aS9 PDR',.

~ P 4

P~

~J'I f

Croup 7:

The valvee fn Croup 7 are autcmatically actuated by only the Coilovfng conditioni

~e st~ supply valve not full-, closed.

Croup 8:

The valve'a in Croup d are autoaatfcally actuated by only the following condition:

1.

High Dryvell preaeure 2.

Reactor vessel low water level (538")

25~

Amendment No.

, 108

~)

'4 r'

CORRECTION TO LICENSE Al1ENDNENT NO.

102 FACILITY OPERATING LICENSE NO.

DPR-52 DOCKET NO. 50-260 Remove the following page and replace with an identically numbered page.

255

p ~

Croup 7:

The valvea in Croup 7 are automatically actuated by only the following condition:

Croup 8:

L. The respec""ve cu bine scare supply valve nor, fully closed.

E The valvaa in Group 8 ara automatically actuated by only the folloving condition:

High Dryvell praaaure 2.Reactor vessel low water.. level (538" )

255 Amendment No.

102

CORRECTION TO LICENSE AMENDMENT NO.

75 FACILITY OPERATING LICENSE NO.

DPR-68 DOCKET NO. 50-296 Remove the following page and replace with an identically numbered page.

267

only the following condition:

The respective turbine steam supply valve not Mly c3.osed.

Group 8:

The.valves in Group 8 are automatically actuated by only '<he folio'wing condition:

t.

High Drywe3.1 Pressure 2.

Reactor vessel low water level (538")

Amendment No.

267