q ACCESSION NBR F ACILt 50-259 50 260 50 296 AUTH,NAME MILLSpL ~ M ~

REC IP ~ t<ANE DENTONqH ~ RE REGULATORY FORMATION DISTRIBUTION S M (RIDS)

$ 84091 90002 DOC ~ DATE 84/09/14 NOTARIZED YES DOCKET Browns Ferry Nuclear Power Station~

Unit l~ Tennessee 05000259 Browns Ferry Nuclear Power Stations Unit 2< Tennessee~Q5K~~O Browns Ferry Nuclear Power Stations Unit 3, Tennessee f5000296 AUTHUR AFF ILIATION Tennessee Valley Authority RECIPIENT AFFILIATION Office of Nuclear Reactor Regulationr Director

SUBJECT:

Submits info re whether recommendations made in GE Svc Info Ltr 402 dealing w/nitrogen injection 5 vent header cracking problem identified in IE Bulletin 84-01 implementediin response to R Herman 840907 verbal requests DISTRIBUTIO~ CODE:

A001D COPIES RECEIVED:LTR FNCL SIZE:

/'ITLE!

OR Submi ttal t Gener al Distribution NOTES;NMSS/FCAF 1cy ~

1cy NMSS/FCAF/PM'L;06/26/73 NMSS/FCAF 1cy, 1cy NMSS/FCAF/PM'Li06/28/74 NMSS/FCAF 1cy ~

1cy NMSS/FCAF/PM'L:07/02/76 05000259 05000260 05000296 RECIPIENT ID CODE/NAME NRR ORB2 BC 01 INTERNAL: ADM/LFMB NRR/DE/MTEB NRR/DL/ORAB NRR/DSI/RAB RGN2 COPIES LTTR ENCL 7

1 1

0 1

1 1

1 RECIPIENT ID CODE/NAME ELD/HDS4 NRR/DL DIR

~

- OS'/METH 04 COPIES LTTR ENCL EXTERNAL: ACRS NRC PDR NTIS NOTES'9 02 LPDR NSIC 03 05 TOTAL NUMBER OF COPIFS REQUIRE D:

LTTR 28 ENCL

TENNESSEE VALLEYAUTHORITY CHATTANOOGA. TENNESSEE 37401 400 Chestnut Street Tower II September 14, 1984 Mr. Harold R. Denton,'Director Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, D.C. 20555

Dear Mr. Denton:

In the Matter of the Tennessee Valley Authority Docket Nos. 50-259 50-260 50-296 As requested verbally by Robert Herman of your staff on September 7,

1984, we are providing the following information for the Br owns Ferry Nuclear Plant.

Specifically, we were requested to inform the NRC regarding whether TVA has implemented the recommendations made in General Electric Service Information Letter (SIL) 402 dealing with the nitrogen injection and vent header cracking problem identified in IE Bulletin 84-01. It was agreed that an initial response would be made by September 14,

1984, and that additional information would be submitted at a later date.

We have reviewed and implemented GE SIL 402 as appropriate for Browns Ferry.

The configuration of the nitrogen infection piping into the wetwell at Browns Ferry is different from the configuration at Hatch Nuclear Plant.

As such, the recommendations of GE SIL 402 may not all be directly applicable to Browns Ferry.

TVA will submit by October 5,

1984, a detailed discussion of how GE SIL 402 recommendations were or are being implemented at Browns Ferry. If a recommendation was not implemented a discussion of why will be provided.

Very truly your s, Subscribed an sworn to for me t te ~g day of TENNESSEE VALLEY AUTHORITY L. M. Mills, anager Nuclear Licensing 1984.

Notar Public My Co ission Expires 4 cc:

U.S. Nuclear Regulatory Commission Region II ATTN:

James P. O'Reilly, Regional Administrator 101 Marietta Street, NW, Suite 2900 Atlanta Georgia 30323 8409190002 840914 PDR ADOCK 05000259 Mr. R. J. Clark 8

PDR Browns Ferry Pro)cot Manager U.S. Nuclear Regulatory Commission 7920 Norfolk Avenue

Bethesda, Maryland 20814 An Equal Opportunity Employer go~I tJy