APPLICANT:
Pennsylvania Power and Light Company FACILITY:
Susquehanna Steam Electric Station, Units 1 and 2
SUBJECT:
SUItARY OF SITE VISIT OF le 1~ 1980 On Hay 1, 1980,a visit was made to the Susquehanna Steam Electric Station site by the NRC Staff and members of DuPont Atomic Energy Division, Savannah River Plant, NRC's support contractor for the review of reactor system and instrumentation.
The purpose of the trip was to familiarize the support contractor personnel with the design and status of the instrumentation and control and reactor systems in the Susquehanna plant.
The attendees list is attached.
Initially, we met as a group and the applicant described the status of construc-tion of the various systems in the plant.
Subsequently the meeting divided into two tours, depending on interest. for a tour of the facility. At the end of the tour we reassembled to discuss questfons that came up as a result of the tour and to discuss problems the licensee had with questions he has received in the areas of Reactor Systems and Instrumentation and Control.
All the reactor systems questions generated by Savannah River have been reviewed by HRC and sent to the applicant.
Mfth regard to the Instrumentatfon and Contro'1 questions generated by Savannah River one set has been sent to the applicant and one set is being reviewed by NRC.
Savannah River is working on an additional set of questions.
The applicant expects to have draft responses to the questions he has received to date about the middle of July.
To further expedite the review.
we agreed to have technical meetings with the applicant to discuss responses to questions as soon as draft responses were available.
OhlelblALSIGHED'BY
Attachment:
List of Attendees Rfch Stark, Project f/anager Licensing Branch Ho.
1 Division of Licensing OFFICE P SURNAME OATE P DL:LB81 RStark:km 05/15/80 800618II~og.
DL:LB81 BSYoungbl ood 05/
/80 NRC FORM 318 t9 76) NRCM 0240 AU.S. GOVERNMENT PRINTING OFFICE: 1979 289'369
1' fh!
FF C
3 i
I J
3
'F
- 3 3
fl
< ~3 IFF I
3 ~
Uv< ~ ~ ~
- f
~
I 3
I f UF
~
4 vh
~
~
t.
3 A:
V<3 V v
1rh r
- 3 F Al
- 0"
'I I ~
3 ~
~
3
(
I II P
U
~ r Fr I
-r~
V r
~
3 3
3 F
3, I
3 I
F
~
I 3
'I I
4 1
'I
~ hr h
3
)
(
3,,
~ <
,I I ',
<I 3'
I 3
jh
<3 A<
I'I r ~
I K
1
~
j vi
~
FF 3
,F
'I 3 hr
$ ~g F
.3'f 3*
1 ~
1' I
~
r If Uh Fh h <Ifl I 3
ii P
1
~ Q I, ~
~ 3
)
~
UV (V'V I
I
MEETING SUN1ARY DISTRIBUTION 7, 50-388)
Docket File (50-'38 NRC PDR Local POR TIC NRR Readin'g LB¹l Reading H. Oenton E.
Case D. Eisenhut.
R. Purple B. J.
Youngblood A. Schwencer Branch Chief, LB¹3 J. Miller G. Lainas R. Vollmer J.
P. Knight R.
Bosnak F. Schauer R.
E. Jackson Project Manager R.
Attorney.,
OELO M. Rushbrook oiE (3-)
ACRS (16)
R. Tedesco NSIC NRC Parti chants:
D. Sullivan J.
Minns T. Y. Chang T.
E. Collins S. Miner BCC:
Aoplicant
& Se Stark rvice List Lear Noonan Pawlicki Benarova Rosztoczy Haass
- Muller, Ballard Regan Ross Check Satterfield Parr Rosa Butler Kreger Houston Muvohy Rubenstein Speis nch Chief, Stolz Hanauer 6ammill Mattson Schroeder Skovholt Ernst Baer Berlinger Kniel Kniqh ton nch Chief, G.
V.
S.
V.
z.
O.
R.
M.
fl.
P.
R.
0.
F.
T.
L.
T.
Bra Ja S.
R.
F.
D.
M.
R.
C.
K.
G.
Bra Cove Performance.
Rel.
& Risk Assessment Bv.
MAY ao
>BBO
[
C t
II l
P (
h
'I A'
I
~
~
pe RECy~
(4 0
Cy
~~a I
0O IA O
Vg+~
gO 0p*~+
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D. C. 20555 NAY 30 IS80 APPLICANT:
Pennsylvania Power and L'ight Company FACILITY:
Susquehanna Steam Electric Station, Units 1 and 2
SUBJECT:
SUMMARY
OF SITE VISIT OF MAY 1, 1980 On May 1, 1980,a visit was made to the Susquehanna Steam Electric Station site by the NRC Staff and members of DuPont Atomic Energy Division, Savannah River Plant, NRC's support contractor for the review of reactor system and instrumentation.
The purpose of the trip was to familiarize the support contractor personnel with the design and status of the instrumentation and control and reactor systems in the Susquehanna plant.
The attendees list is attached.
Initially, we met as a group and the applicant described the status of construc-tion of the various systems in the plant.
Subsequently the meeting divided into two tours, depending on interest, for a tour of the facility.
At the end of the tour we reassembled to discuss questions that came up as a result of the tour and to discuss problems the licensee had with questions he has received in the areas of Reactor Systems and Instrumentation and Control.
All the reactor systems questions generated by Savannah River have been reviewed gaby NRC and sent to the applicant.
With regard to the Instrumentation and Control questions generated by Savannah River one set has been sent to the applicant and one set is being reviewed by NRC, Savannah River is working on an additional set of questions.
The applicant expects to have draft responses to the questions he has received to date about the middle of July.
To further expedite the review, we agreed to have technical meetings with the applicant to discuss responses to questions as soon as draft responses were available.
Attachment:
List of Attendees Rich Stark, Project Manager Licensing Branch No.
1 Division of Licensing
t 'I y iL
'k I
II
~ ~
(
h
~A" l
a
~
l
MAY 1, 1980 NRC SITE MEETING Name W. E. Barberich C.
P.
Ross L. D. O'eil D.
F. Sullivan John Minns T. Y. Chang T. E. Collins H.
R.
Reeve G.
W. McManaway A. E.
Hadden N.
E. Barnett N. T. Hightower V. Peter H.
E. Stokes Russ Nossardi E. Connell, III Ralph Bloomstrand N. David Weiss T.
R. Wortham Thomas E. Gangloff William W. Williams W. J.
Jones R. A. Moor R. A. Bresler A. P.
Derhaus B. J. Skoras A.
M. Stern N. Coddington S. Miner Or anization Licensing -
PP&L DuPont - SRP PP&L - Plt Staff NRC NRC NRC NRC - Reactor Systems Branch DuPont DuPont DuPont DuPont DuPont PP8L Construction PP&L Construction Bechtel Engineering Bechtel Engineering GE - Licensing GE - Projects GE - Licensing PP&L - Licensing PP&L - Licensing PP&L Construction PP&L Construction PP&L Construction PP8L Engineering PP&L Engineering PP&L Engineering PP&L Licensing NRC/DPM MAY 20 1S80
N V
Mr. Norman W. Curtis Vice President
- Engineering and Construction Pennsylvania Power and Light Company 2 North Ninth Street Al 1entown, Pennsyl vania 18101 cc Mr. Earle M. Mead Project Engineering Manager Pennsylvania Power
& Light Company 2 North Ninth Street Al 1 entown, Pennsyl vani a 18101.
Jay Si 1 berg, Esq.
Shaw, Pittman, Potts Trowbridge 1800 M Street, N.
W.
Washington, D. C.
20036 Mr. William E. Barberich, Nuclear Licensing Group Supervisor Pennsylvania Power
& Light Company 2 North Ninth Street Al 1 entown, Pennsyl vania 18101 Edward M. Nagel, Esquire General Counsel and Secretary Pennsylvania Power
& Light Company 2 North Ninth Street Al 1 entown, Pennsyl vani a 18101 Bryan Snapp, Esq.
Pennsylvania Power
& Light Company 901 Hamilton Street Al 1 entown, Pennsyl vani a 18101 Robert M. Gallo Resident Inspector P. 0.
Box 52 Shickshinny, Pennsyl vani a 18655 Susquehanna Environmental Advocates c/o Gerald Schultz, Esq.
500 South River Street Wilkes-Barre, PA 18702 John L. Anderson Oak Ridge National Laboratory Union Carbide Corporation Bldg. 3500, P.
O.
Box X
Oak Ridge, Tennessee 37830 Iir. Robert J. Shovlin Project Manager Pennsylvania Power and Light Co.
2 North Ninth Street Al 1 entown, Pennsyl vani a 18101 Matias F. Travieso-Diaz, Esq.
Shaw, Pittman, Potts Trowbridge 1800 M Street, N.
W.
Washington, D. C.
20036 Dr. Judith H. Johnsrud Co-Director Environmental Coalition on Nuclear Power 433 Orlando Avenue State College, PA 16801 Mr. Thomas M. Gerusky, Director Bureau of Radiation Protection Department of Environmental Resources Commonwealth of Pennsylvania 0.
Box 2063 Harrisburg, PA 17120 Ms. Colleen Marsh Box 538A, RD84 Mountain Top, PA 18707 Mrs. Irene Lemanowicz, Chairperson The Citizens Against Nuclear Dangers P. 0.
Box 377 RD//1
- Berwick, PA 18503
I I
L
)
~qq qE'00
~G~
Wp0 Cy 0O
+r~
~O
++*++
, ft 4'gJ;
,... 0 NUCLEAR REGULATORY COMMISSION WASHINGTON, D. C. 20555 Docket Nos.
50-387/388 APR 1 ~ >98O MEMORANDUM FOR:
Dian D. Parr, Chief, Light Water Reactors Branch No. 3, DPM FROM:
SUBJECT:
DATE AND TIt~lE'OCATION:
PURPOSE:
PARTICIPANTS:
Richard M. Stark, Project Manager, Light Water Reactors Branch No. 3, DPM FORTHCOMING SITE VISIT TO THE SUSQUEHANNA STEAM ELECTRIC STATION
- Thursday, May 1, 1980 9:00 AM Susquehanna Steam Electric Station Site, Berwick, Pennsylvania.
To view the status and configuration of the primary systems (Feedwater,
(agenda attached).
NRC T. Collins, S. Miner, R. Stark, D. Sullivan, et al.
SAVANNAH RIVER H. Reeve, et al.
PPSL W. Barberick, et al.
Enclosure:
As Stated cc w/enclosure:
See next page Light Water Reactors Branch No.
3 Division of Project Management
I V>>t
Mr. Norman W. Curtis Vice President
<<Engineering and Construction Pennsylvania Power and Light Company
- 2. North Ninth Street Al 1 entown, Pennsyl vani a 18101 CC:
Mr. Earle M. Head Project Engineering Manager Pennsylvania Power
& Light Company 2 North Ninth Street Al 1 entown, Pennsyl vania 18101 Jay Silberg, Esq.
'haw, Pittman, Potts Trowbridge 1800 H Street, N.
W.
Washington, D. C.
20036 Hr. William E, Barberich, Nuclear Licensing Group Supervisor Pennsylvania Power
& Light Company 2 North Ninth Street Al 1 entown, Pennsyl vani a 18101 Edward M. Nagel, Esquire General Counsel and Secretary Pennsylvania Power
& Light Company 2 North Ninth Street Al 1 entown, Pennsyl vani a 18101 Bryan Snapp, Esq.
Pennsylvania Power
& Light Company 901 kamilton Street Al 1 entown, Pennsyl vania 18101 Robert M. Gallo Resident Inspector P. 0.
Box 52 Shickshinny, Pennsyl vani a 18655 Susquehanna Environmental Advocates c/o Gerald Schultz, Esq.
500 South River Street Wi lkes-Barre, PA 18702 John L. Anderson Oak Ridge National Laboratory Union Carbide Corporation Bldg. 3500, P. 0.
Box X
Oak Ridge,'ennessee 37830 Hr. Robert J. Shovlin Project Manager Pennsylvania Power and Light Co.
2,North Ninth Street.
Al 1 entown, Pennsyl vania 18101 Hatias F. Travieso-Diaz, Esq.
Shaw, Pittman, Potts Trowbridge 1800 M Street, N.
W.
Washington, D. C.
20036 Dr. Judith H. Johnsrud Co-Director
.Environmental Coalition on Nuclear Power 433 Orlando Avenue State College, PA 16801 Hr. Thomas M. Gerusky, Director Bureau of Radiation Protection Department of Epvironmental Resources Comnonwealth of Pennsylvania P. 0.
Box 2063 Harrisburg, PA 17120 t
Hs. Colleen Harsh Box 538A, RD¹4 Mountain Top, PA 18707 Mrs. Irene Lemanowicz, Chairperson The Citizens Against Nuc/ear Dangers P. 0.
Box 377 RD¹1
- Berwick, PA 18503
ENCLOSURE AGENDA SUS UEHANNA TOUR l.
Overview of Plant Status by PP8L personnel 2.
Tour of Unit 1 to view the main systems which are presently installed 3.
Discussion.of tour