ML18025A890

From kanterella
Jump to navigation Jump to search
Forwards LER 80-020/03L-0
Date released: 09/27/2018 Download: ML18025A890


LER 80-020/03L-0:on 800421,high Pressure Switch PS-3-22D Found Exceeding Setpoint During Normal Operation.Caused by Setpoint Drift.Barksdale BST-A12SS Switch Inspected,Calibr & Functionally Tested
ML18025A891
Person / Time
Site: Browns Ferry 
Issue date: 05/20/1980
From:
TENNESSEE VALLEY AUTHORITY
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML18025A891 (4)
Forwards LER 80-020/03L-0
ML18025A889
Person / Time
Site: Browns Ferry 
Issue date: 05/20/1980
From: Calhoun J
TENNESSEE VALLEY AUTHORITY
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML18025A889 (2)