ML18025A855

From kanterella
Jump to navigation Jump to search
Forwards LER 80-010/03L-0
Date released: 09/27/2018 Download: ML18025A855


LER 80-010/03L-0:on 800410,while Performing S.I. 4.2.A-3, LIS-3-56A SW1 & 2 & LIS-3-56B SW2 Failed to Operate.Caused by Dirty Contacts.Contacts Were Cleaned & Switches Checked for Proper Setpoint & Repeatability
ML18025A856
Person / Time
Site: Browns Ferry 
Issue date: 05/08/1980
From:
TENNESSEE VALLEY AUTHORITY
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML18025A856 (3)
Forwards LER 80-010/03L-0
ML18025A854
Person / Time
Site: Browns Ferry 
Issue date: 05/08/1980
From: Calhoun J
TENNESSEE VALLEY AUTHORITY
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML18025A854 (2)