NRC DISTRIBUTION FOR PART 50 DOCKET MATERI (TEMPORARY FORM)
AL CO~TRO~ NO: ""
FILE'ROM.
Pennsylvania Power 6 Light Co, Allentown, Pa DATE OF DOC DATE REC'D LTR TWX RPT OTHER To.
Dr. Walter R. Butler
.ORIG 1-signed CC OTHER SENT NRC PDR SENT LOCALPDR CLASS UNCLASS PROPINFO XXX DESCRIPTION INPUT NO CYS REC'0
'DOCKET No:"
50<<387 and 388 ENCLOSURES:
Ltr re our 6-5-75 ltr
~..trans the following Dist Per MD Rushbrook 8-20-75 PLANT NAME:
Susquehanna 1 & 2 SusQuehanna, Steam Electric'Station I
Suppression Pool Drawings '....
~
( 15 cys'nc'1 rec'd)
QTOy~TT ~q~~g FOR ACTION/INFORMATION 8-21-75 JGB UTLER (L)
W/ Copies CLARK (L)
W/ Copies PARR (L)
W/ Copies KNIEL (L)
W/ Copies SCHWENCER (L)
ZIEMANN(L)
W/ Copies W/ Copies STOLZ (L)
DICKER (E)
W/ Copies W/ Copies VASSALLO (L)
KNIGHTON (E)
W/ Copies W/ Copies PURPLE (L)
YOUNGBLOOD (E)
W/ Copies W/ Copies REGAN (E)
W/ Copies LEAR (L)
W/ Copies SPIES W/ Copies LPM W/
opuses REID(L)
W/
COPIES INTERNAL DISTR IBUTION LIC ASST R. DIGGS (L)
H. GEARIN (L)
E. GOULBOURNE (L)
P. KREUTZER (E)
J. LEE (L)
~ RUBHBROQK(L)g+g S. REED (E)
M. SERViCE (L)
S. SHEPPARD (L)
M. SLATER (E)
H. SMiTH (L)
S. TEETS (L)
G. WiLLiAMS(E)
V. WILSON (L)
R. INGRAM (L)
M. DUNCAN EXTERNALDISTRIBUTION T+CH REVIEW DENTON
~RC PDR 4a
~GC, ROOM P-506AIACCARY
~44 CiAMMILL GOSSI CK/STAF F ~ I G HT g
KASTNER CASE PAWLICKI BALLARD GIAMBUSSO
~HAO A
SPANG LE R BOYD STELLO MOORE (L)
HOUSTON ENVIRo
~8fYOUNG (Lgfg NOVAK MULLER SKOVHOLT (L) 'OSS DICKER GOLLER (L) (Ltr)
IPPOLITO KNIGHTON P. COLLINS
~DESCO ~ + YOUNGBLOOD DENISE S. COLT.INS R EG AN
~G OPR ML WAINAS PROJECT LDR FILE 5 REGION (2)
BENAROYA MIPC VOLLMIER HAR LESS A/T IND
~
B RAITMAN SALT7MAN MELTZ PLANS MCDONALD CHAPMAN DUBE (Ltr)
E. COUPE PETERSON HARTFIELD (2)
KLECKER EISENHUT WIGGINTON
~ LOCALPDR Wjlks Barre, Pa 1 TIC (ABERNATHY)
(1)(2)(10) NATIONALI ABS 1 NSIC (BUCHANAN) 1 W. PENNINGTON, Rrn E-201 GT 1 ASLB 1
CONSUI TANTS 1 Newton Anderson NEWMARK/BLUME/AGBAHIAN
~~ AORS IROLDING/SENT
<g4.
1 PD R-SAN/LA/NY 1 BROOKHAVEN NAT LAB 1 G. ULRIKSON ORNL
I
~
O tt
~ ~
~
~
~
~
~
~
~
1
)
I'l g
II 1
tepelL TWO NORTH NINTH STREET, ALLENTOWN, PA.
18101 PHONEME (215) 821-5151 August 7, 1975 (pc
<ci FJp@
p, Dr. Walter R. 'Butler, Chief Light Water Reactors Branch 1-2 ~4&00 Division of Reactor Licensing U.
S. Nuclear Regulatory Commi'ssion Washington, D.C.
20555 File Cy'.
SUSQUEHANNA STEAM ELECTRIC STATION CONTAINMENT DESI'NFORMATION ER 100450 FILE 170 PLA-77 DOCKET NOS.
50-387 and 50-388
Dear Dr. Butler:
In accordance with item 1 of the Mark II Containment Program described in our June 5, 1975 letter, we are enclosing 15 copies of the appropri-ate drawings.
Attached is a list of the numbers and titles of these drawings.
Drawing M-141, Rev. 1, Nuclear Boiler P&ID, containes information on the safety relief valve (SRV) numbers, set points and modes of operation.
This P&ID was forwarded to you in October, 1974.
The structural capability of the components and structures in the sup-pression pool which may be affected by SRV actuation will be submitted in November, 1975 as described in item 4 of the Mark II Containment Program.
Very truly yours, 11~,
I
'4A N.
W. Curtis Vice President Engineering and Construction
'I WEB:SLB Enclosures PENNSYLVANIA POWER 8
LIGHT COMPANY
~
1 ll 1
SUSQUEHANNA STEAM ELECTRIC STATION SUPPRESSION POOL DRAWINGS BECHTEL DESIGN DRAWINGS Reactor Buildin Units 1 and.
2 Liner Plate C-277 Rev.
14 Developed Elevation C-281 Rev.
7 Base Floor Plan 8 Details C-282 Rev.
7 Suppression Chamber Details C-293 Rev.
8 Diaphragm Floor Plan 8 Details Reactor Buildin Units 1 and. 2 Prim Containment C-331 Rev.
C-344 Rev.
C-370 Rev.
C-371 Rev.
C-372 Rev.
C-373 Rev.
5-3-
3-7 8-2 General Arrangement Suppression Chamber Wall Sections
& Details Suppression Chamber Steel Columns Vent Pipe Arrangement Vent Pipe Details Suppression Chamber Platforms Plant Desi n Drawin s Reactor Buildin Unit 1 M-25-1 Rev.
M-25-2 Rev.
M-25-3 Rev.
M-25-8 Rev.
M-27-1 Rev.
M-27-2 Rev.
M-27-3 Rev.
M-28-1 Rev.
M-28-2 Rev.
M-28-3 Rev.
M-28-9 Rev.
M-29-1 Rev.
M-29-2 Rev.
M-29-3 Rev.
M-70 "'ev.
4 Area 25 Plan of EL. 645-0 5 Area 25 Plan of El. 670-0 6 - Area 25 Plan of El. 683-0 5 Area 25 Misc. Details 4 Area 27 Plan of El. 645-0 5 Area 27 Plan of El. 670-0 9 Area 27 Plan of El. 683-0 5 Area 28 Plan of El. 645-0 4 Area 28 Plan of El. 670-0 4 Area 28 Plan of El. 683-0 3 Area 28 Misc. Details 4 - Area 29 Plan of El. 645-0 2 Area 29 Plan of El.'70-0 4 Area 29 Plan of El. 683-0 4 Details of Flued Heads General Arran ement Dr'awin s'-201Rev.
F Plan of Ground. Floor El. 676-0
& 668-0 M-207 Rev.
F Sections A-A and. B-B VENDOR PRINT DRAWINGS M-87-31-4 Electric Hydrogen Recombiner Enclosure Arrangement M-149-3-4 Outline Dimension Primary Containment Vacuum Relief Assembly
o 0'
I