Forwards LER 80-003/03L-0
Date released: 09/27/2018 Download: ML18024B355


LER 80-003/03L-0:on 800126,while Performing Control Rod Exercise,Control Rod 18-55 Would Not Insert W/Normal Drive Pressure.Caused by Failed Seal in Hydraulic Control Unit Directional Control Valve.Valve Repaired
ML18024B356
Person / Time
Site: Browns Ferry Tennessee Valley Authority icon.png
Issue date: 02/22/1980
From:
TENNESSEE VALLEY AUTHORITY
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML18024B356 (3)
Forwards LER 80-003/03L-0
ML18024B354
Person / Time
Site: Browns Ferry Tennessee Valley Authority icon.png
Issue date: 02/22/1980
From: Calhoun J
TENNESSEE VALLEY AUTHORITY
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References