ML18024B030

From kanterella
Jump to navigation Jump to search
Forwards LER 79-013/03L-1
Date released: 09/27/2018 Download: ML18024B030


LER 79-013/03L-1:on 790530,reactor Core Isolation Cooling Sys Tripped on Overspeed During Flow Test.Caused by Improper Assembly Which Allowed Turbine Wheel Nut to Loosen,Causing Axial Loading of Bearings
ML18024B031
Person / Time
Site: Browns Ferry 
Issue date: 09/24/1979
From:
TENNESSEE VALLEY AUTHORITY
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML18024B031 (5)
Forwards LER 79-013/03L-1
ML18024B029
Person / Time
Site: Browns Ferry 
Issue date: 09/24/1979
From: Calhoun J
TENNESSEE VALLEY AUTHORITY
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML18024B029 (2)