Tennessee Waterway Assessment Study prepared for The Nashville District of the U.S. Army Corps of Engineers and The Tennessee Department of Transportation June 25, 2007 Prepared By:
Hanson Professional Services Inc.
One Burton Hills Blvd., Suite 360 Nashville, TN 37215 (615) 665-9611
TABLE OF CONTENTS
1.0 INTRODUCTION
& PURPOSE..................................................................................... 1 2.0 OVERVIEW OF HISTORIC AND CURRENT INLAND WATERWAY SYSTEM IN TENNESSEE.................................................................... 2 2.1 Early Pioneer Settlement...................................................................................... 2 2.2 U.S. Army Corps of Engineers............................................................................. 5 2.3 The First Locks and Dams................................................................................... 5 2.4 Establishing the Tennessee Valley Authority..................................................... 6 2.5 Managing the Rivers Today................................................................................. 7 2.5.1 Cumberland River Locks and Dams..................................................... 10 2.5.2 Tennessee River Locks and Dams......................................................... 12 2.6 Tennessee Department of Transportation........................................................ 16 2.7 Transportation Overview................................................................................... 18 3.0 WATERBORNE COMMERCE.................................................................................... 20 3.1 Waterborne Commodity Movements................................................................ 25 3.1.1 Mississippi River..................................................................................... 31 3.1.2 Tennessee River....................................................................................... 31 3.1.2.1 West TN River - River Miles66-210........................................ 34 3.1.2.2 East TN River - River Miles 416-652....................................... 34 3.1.3 Cumberland River.................................................................................. 39 4.0 RIVER TERMINAL INVENTORY............................................................................. 43 4.1 Inventory Methodology...................................................................................... 43 4.2 Terminal Categories........................................................................................... 44 4.2.1 River Terminal Ownership.................................................................... 44 4.2.2 River Terminal Operation..................................................................... 44 Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page i
TABLE OF CONTENTS (continued) 4.2.3 River Terminal Use................................................................................. 45 4.2.3.1 Special Purpose Terminals........................................................ 46 4.2.3.2 General Purpose Terminals...................................................... 55 5.0 PUBLIC AND STAKEHOLDER OUTREACH.......................................................... 67 5.1 Identification of Stakeholder Group................................................................. 67 5.2 Programs in Neighboring States........................................................................ 68 6.0
SUMMARY
AND CONCLUSIONS............................................................................. 75 Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page ii
LIST OF EXHIBITS 2-1 Locks and Dams on the Cumberland River................................................................... 8 2-2 Locks and Dams on the Tennessee River........................................................................ 9 2-3 Transportation Routes - State of Tennessee................................................................. 19 3-1 Inland Waterway System............................................................................................... 21 3-2 2004 Inland Waterway System - Trends in Commerce............................................... 22 3-3 Comparisons of Transportation Modes........................................................................ 23 3-4 Fuel Efficiency by Transportation Mode...................................................................... 24 3-5 2004 Trends in Commerce on the Mississippi River................................................... 26 3-6 2004 Trends in Commerce on the Tennessee River..................................................... 27 3-7 2004 Trends in Commerce on the Cumberland River................................................ 28 3-8 2004 Commodities Moved To, From and Within Tennessee...................................... 29 3-9 Mississippi River 2004 Inbound Tonnage - River Miles 700-925............................... 32 3-10 Mississippi River 2004 Outbound Tonnage - River Miles 700-925............................ 33 3-11 West Tennessee River 2004 Inbound Tonnage - River Miles66-210......................... 35 3-12 West Tennessee River 2004 Outbound Tonnage - River Miles66-210...................... 36 3-13 East Tennessee River 2004 Inbound Tonnage - River Miles 416-652........................ 37 3-14 East Tennessee River 2004 Outbound Tonnage - River Miles 416-652..................... 38 3-15 Cumberland River 2004 Inbound Tonnage - River Miles 100-380............................ 40 3-16 Cumberland River 2004 Outbound Tonnage - River Miles 100-380......................... 41 4-1 Liquid Terminals............................................................................................................ 47 4-2 Grain Terminals.............................................................................................................. 48 4-3 Dry Bulk Terminals........................................................................................................ 50 4-4 Sand and Gravel Terminals........................................................................................... 51 4-5 Cement Terminals........................................................................................................... 52 4-6 Fertilizer Terminals........................................................................................................ 53 4-7 On Site Terminals........................................................................................................... 54 Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page iii
LIST OF EXHIBITS (continued) 4-8 Navigation/Marine Service Terminals.......................................................................... 56 4-9 Other Terminals.............................................................................................................. 57 4-10 Inactive Terminals.......................................................................................................... 58 4-11 General Purpose Terminals........................................................................................... 59 APPENDIX A
Inventory of General Purpose River Terminals in Tennessee.................................. A-1 Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page iv
1.0 INTRODUCTION
AND PURPOSE The State of Tennessee is centrally located on the nations inland waterway system. With more than 1,062 miles of navigable waterways, Tennessee waterways connect terminals on the Tennessee, Cumberland, and Mississippi Rivers, and their tributaries, with river ports in 21 states and ocean ports in Houston, New Orleans, and Mobile.
The Tennessee Waterway Assessment Study (Study) is intended to provide short and long-range plans of action so that the Cumberland, Mississippi, and Tennessee River Systems and their tributaries will maintain their recognition as part of the national transportation system. The primary objectives are to increase the use of water transportation and improve regional and national economic conditions by increasing utilization of cost-effective, fuel-efficient, environmentally-friendly waterway transportation. To fully address this goal, the Tennessee Department of Transportation (TDOT) entered into an agreement with the U.S. Army Corps of Engineers, Nashville District (COE) to provide an overview of the inland waterways in Tennessee. The COE entered into an agreement with GKY & Associates which subcontracted the work to Hanson Professional Services Inc.
Phase 1 of the Study provides baseline information comprised of the following:
- 1. An overview of the Inland Waterways in Tennessee, in context of freight transportation.
- 2. An inventory of existing commercially navigable waterways in Tennessee, facilities and terminals, focusing on general cargo terminals and multimodal freight transportation infrastructure at these river ports.
- 3. A general assessment of waterborne commodity flows.
- 4. Identification of stakeholder groups and programs in neighboring states with regards to waterways transportation and port development.
- 5. Recommendations for Phase II tasks and scope of work.
Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page 1
2.0 OVERVIEW OF HISTORIC AND CURRENT INLAND WATERWAY SYSTEM IN TENNESSEE The Tennessee and Cumberland Rivers were first mapped in 1769. Both rivers had nearly identical characteristics; wild, fluctuating streams; tortuous, boulder-littered channels; broken by serious obstructions to navigation. Together these rivers comprise what has historically been referred to as the Twin Rivers.
2.1 Early Pioneer Settlement No discussion of early pioneer settlement in Tennessee is complete without mention of the names Robertson and Donelson. James Robertson and Col. John Donelson joined forces in 1779 to settle in Middle Tennessee. The seemingly innocuous plan called for Robertson to lead the men over land to current-day Nashville while the women and children followed by boat, led by Col. Donelson. This expedition marked the first recording of the hazards of the twin rivers.
Donelsons route called for the partys flotilla of boats to sail from Fort Patrick Henry down the Holston River to the Tennessee River, down the Tennessee River to the Ohio River, thence up the Ohio to the Cumberland River and up the Cumberland River.
Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page 2
That journey saw obstacles in the forms of impassable shoals, tumultuous eddies, Native American attacks, and smallpox. The first leg of the trip, traversing down the Tennessee, was the most dangerous. That passage took three months and in that time, according to Col.
Donelsons journal, 28 members of the party were killed, at least five more injured by Native American attacks, and all were hungry, weak, and tired.
The second phase of the journey was to navigate the Cumberland River from present-day Paducah, KY upstream against the rising waters of the cantankerous Cumberland in unwieldy craft entirely unsuited for upstream navigation. The flotilla made it thanks to much paddling, poling, and pulling, as well as a make-shift sail. Donelson and his party finally reunited with Robertson and the rest of the men on April 24, 1780. They had departed on December 22, 1779.
New settlement inevitably invites new trade and Robertsons and Donelsons Middle Tennessee settlement was no exception. From Leland Johnsons book Engineers on the Twin Rivers: A History of the Nashville District United States Army Corps of Engineers:
despite the difficulties of navigating the unimproved channel of the Cumberland, Indian resistance to the incursion of the settlers, and heavy duties laid on commerce by the Spanish on the Lower Mississippi, flatboats crammed to the gunwales with the bountiful produce of the Cumberland Valley were soon embarking from the Middle Tennessee settlements on the way to market at New Orleans.
In 1785 North Carolina, of which the Tennessee settlements were a part until 1790, established a tobacco inspection program in Davidson County and another at Clarksville in 1789.
There was such an extensive trade on the Cumberland by 1797 that Congress established Palymyra, Tennessee, as a port of entry, one of the first on the Transappalachian frontier.
Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page 3
This trade typically moved by flatboats. By definition, a flatboat is a boat with a flat bottom and square ends used to transport freight on inland waterways. The nature of these boats was such that they could float downstream, but not back up. Once a flatboat reached its destination, it was disassembled and its crew had to walk back to the point of origin. For trade between Middle Tennessee and the area between New Orleans and Natchez, this walk was usually along the Natchez Trace.
In the late 1700s and early 1800s, the Natchez Trace was used extensively by Native Americans and early Caucasian explorers as both a trade and transit route.
By the early 1800s, more advanced ships such as steamers were successfully advancing trade on inland waters such as the Hudson and Mississippi Rivers. Would-be traders on the Twin Rivers, however, found themselves facing the same obstacles as Donelson - the waterways were, simply put, difficult to navigate. Perhaps the greatest navigational obstacle that the Tennessee River posed is the rampant, racing waters of Muscle Shoals. In 1836 a canal was built around the Muscle Shoals by the State of Alabama with Federal Aid. The canal was not very successful because ships could not pass during the low waters months. No maintenance was performed on the canal because no funds had been appropriated. In 1838, the canal was abandoned and by the mid-1800s, the railroads began to take traffic away from the rivers.
In 1867, there was a renewed interest in water transportation on the Tennessee River, especially throughout the Shoals area. This time, the reconstruction of the canal to bypass the treacherous navigation in the Shoals area was funded and engineered by the federal government. Using an innovative design, the canal was widened and reconstructed with a series of locks and dams.
This design later aided in the planning of the Panama Canal.
Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page 4
In 1890, the first steamboat traveled from St. Louis to Chattanooga through the redesigned canal linking the Shoals area to the ever changing world. The Muscle Shoals Canal was one of the 19th centurys amazing accomplishments.
The canal increased river transportation, which in turn increased trade, leading the way for the use of inland waterways as a viable alternative for the transportation of goods.
An Early Steamboat 2.2 U.S. Army Corps of Engineers The beginnings of trade on the Cumberland River had similar tumultuous beginnings as the Tennessee River. From the beginning of commercial navigation until the Civil War, little effort was made to improve these waterways.
In the 1820s, steamboats were carrying tobacco, hemp, and cotton down the Cumberland. The Cumberland, however, was extremely perilous. Impassable at low water levels, steamboat accidents became commonplace.
In April of 1824, Congress passed the General Survey Act, charging the U.S. Army Corps of Engineers (COE) to prepare surveys, plans, and estimates to improve channels. Then, in May 1824, the first Rivers and Harbors Act was passed. It provided for the improvement of navigation by removing snags, old sand bars, and timber from the banks. From this date on, the COE was given the mission of keeping the rivers navigable.
2.3 The First Locks and Dams Canal projects on the Twin Rivers contributed to the renewal of hope and revival of trade and industry in the Tennessee and Cumberland River valleys after the Civil War. Canals, however, Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page 5
were not the long-term solution to navigational problems. For deep-draft vessels, the construction of locks and dams would be required.
First Lock - Lock 1 on the Cumberland River begins to take shape in August 1888 In 1887, plans were prepared for the first lock and dam on the Cumberland River, right across from the Metro Center Levee, creating a pool for Nashville, the busiest harbor on the Cumberland. This ultimately led to the beginnings of the Nashville District Corps of Engineers in 1888. The Districts first task was to oversee the construction of a series of locks and dams on the Cumberland River.
Over the next 40 years, fifteen locks and dams were built on the Cumberland River and were kept in service until the modern, multi-purpose dams that are now in operation were constructed.
2.4 Establishing the Tennessee Valley Authority In 1933, Congress, under the leadership of Franklin D. Roosevelt, passed the Tennessee Valley Authority (TVA) Act. The purpose of the act was to form an agency that would improve the navigability and flood control of the Tennessee River, and provide for affordable power, economic growth and protection of natural resources.
Since TVAs inception, the agency has contributed to the economic development of the Tennessee Valley region. In the 1930s, dams were built to control floods, improve navigation, and generate electricity.
During the early 1940s, TVA engaged in one of the largest hydropower construction programs ever undertaken in the United States, building 12 hydroelectric projects and a steam plant.
Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page 6
By the 1950s, TVA had completed a 650-mile navigation channel the length of the Tennessee River and had become the nations largest electricity supplier.
In the years to follow, TVA continued to lead the way in the energy and environmental areas.
2.5 Managing the Rivers Today In most of the United States, the COE has responsibility for the operation and maintenance of commercial navigation projects, while the U.S. Coast Guard (USCG) ensures safe transportation on America's waterways and protection of the marine environment. On the State of Tennessee River however, the responsibility for operation and maintenance of the navigable inland waterways is shared between the COE and TVA. This shared responsibility is further described in the following paragraphs.
On the Cumberland and Mississippi Rivers, the COE is responsible for the direction of all water resource activities. This entails the operation and maintenance of 4 navigation lock projects on the Cumberland River. The COE also maintains a commercial navigation channel along 355 miles of the Mississippi River which borders the State of Tennessee. Since there are no locks or dams on the Mississippi River below St. Louis, the COEs responsibility on this portion of the river is primarily river maintenance for navigability.
On the Tennessee River, the COE works in partnership with TVA. TVA owns and manages the overall system which includes nine main and four auxiliary locks. The COE operates the locks, performs maintenance dredging on the main channel, and designs and builds new locks and major rehabilitations. TVA and the COE share responsibility for lock maintenance and lock facility design and construction. The USCG installs and maintains the navigation aids along the commercial channel.
Of the locks and dams managed by the COE and TVA, eight are physically located in the State of Tennessee; three on the Cumberland River and five on the Tennessee River as shown in Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page 7
Exhibits 2-1 and 2-2. These river dams form a staircase of quiet, pooled water and controlled current.
Staircase formed by Locks and Dams Tennessee River C u m b e r l a n d R i v e r Nashville TN Ohio River Barkley Canal Mile 32.8 Cheatham Lock Mile 148.7 Old Hickory Lock Mile 216.2 Cordell Hull Lock Mile 313.5 T
T T
T Barkley Lock Mile 30.6 KY Exhibit 2-1. Locks and Dams on the Cumberland River Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page 8
TN AL KY MS GA Tenn-Tom Waterway T e n n e s se e R i v e r Tennessee River C u m b e r l a n d R i v e r T e n n e s se e R i v e r O h i o R i v e r Knoxville Chattanooga Florence Decatur T
T T
T T
T T
T Wilson Lock Mile 259.4 Wheeler Lock Mile 274.9 Guntersville Lock Mile 349.0 Nickajack Lock Mile 424.7 Watts Bar Lock Mile 529.9 Fort Loudoun Lock Mile 602.3 Chickamauga Lock Mile 471.0 T
Mile 22.3 Barkley Canal Mile 25.3 Staircase formed by Locks and Dams on the Tennessee River Kentucky Lock Pickwick Lock Mile 206.7 Exhibit 2-2. Locks and Dams on the Tennessee River Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page 9
2.5.1 Cumberland River Locks and Dams (Source: U.S. Army Corps Engineers)
Barkley Lock & Dam - Barkley Lock and Dam is located on the Cumberland River 30.6 miles upstream of the Ohio in Grand Rivers, KY. The lock was opened to navigation in 1964 and has clear chamber dimensions of 800 x 110. The Cumberland River downstream of Barkley Lock features several sharp turns (or bends) which limit navigation to one tow at a time. This, combined with varying flow levels on the Cumberland, cause the towing industry to favor using Kentucky Lock for loaded barges and Barkley Lock for empty barges.
Cheatham Lock - Cheatham Lock is located near Ashland City, TN at river mile 148.7 on the Cumberland River. The lock is the second lock on the river approximately 40 river miles downstream from Nashville, TN. Construction was started on Cheatham Lock in 1950 and the lock went into temporary operation December 12, 1952. It went into permanent operation on August 7, 1954.
The lock chamber is 800 x 110 and provides a normal lift of 26 feet. Also, the chamber requires 17,115,429 gallons of water and approximately 12 minutes to fill. It takes approximately 15 minutes to empty.
Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page 10
Old Hickory Lock & Dam - Old Hickory Lock and Dam, located on the Cumberland River at mile 216.2 in Sumner and Davidson Counties, Tennessee, is approximately 25 miles upstream from Nashville, Tennessee. The city of Hendersonville is situated on the northern shoreline of the lake and the city of Old Hickory is located on the southern side of the lake, just upstream of the lock and dam. The lake extends 97.3 miles upstream to Cordell Hull Lock and Dam near Carthage, Tennessee. Built in 1954, the locks dimensions are 400 x 84.
Cordell Hull Lock & Dam - Built in 1973, Cordell Hull Lock and Dam is located at Cordell Hull Lake on the Cumberland River at river mile 313.5, about 5 miles upstream of the city of Carthage, Tennessee. Built in 1973, the lock dimensions are 400 x 84. Modern lock facilities are provided for through river traffic from above Nashville to the head of navigation near Celina, Tennessee. It takes approximately 30 minutes to lock a boat through the 400 x 84 foot lock which contains approximately 17 million gallons of water.
Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page 11
2.5.2 Tennessee River Locks and Dams (Source U.S. Army Corps Engineers)
Kentucky Lock - Kentucky Lock is located near Gilbertsville, Kentucky, 22.3 miles from the confluence of the Tennessee and Ohio Rivers. It is 20 miles east of Paducah, Kentucky. The 184 mile reservoir created by Kentucky Dam stretches across parts of Tennessee and Kentucky and is the largest in the Eastern U.S.
Built in 1942, the lock dimensions are 600 x 110.
Ground was broken in October of 1999 on a new 1,200 x 110 lock. Completion of the new lock under realistic funding scenarios may not occur until beyond 2020. The existing lock will continue to be used as an auxiliary.
Pickwick Lock - Pickwick Lock is approximately 12 miles south of Savannah, Tennessee. It is just north of the Mississippi state line.
Located at Tennessee River mile 206.7, it is 52.7 miles below Wilson Lock and 184.7 miles above Kentucky Lock. There are two locks. The main lock is 1,000 x 110. The auxiliary lock is 600 x 110. Construction on the first lock was completed in 1937 by TVA. The larger lock was completed and put into operation in 1982.
Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page 12
Wilson Lock - Wilson Lock is located in the northwest corner of Alabama.
Located at Tennessee River mile 259.4, the lock is 15 miles below the Wheeler Locks and 52.7 miles above Pickwick Lock.
It is the highest single lift lock east of the Rocky Mountains with a normal lift of between 93 and 100 feet. Originally built in 1927, several improvements were made by TVA in 1959 including completion of the main single-lift lock to replace the old double-lift lockage system. The new lock began operating on November 10, 1959 and is 600 x 110.
Wheeler Lock - The Wheeler Locks are located about 30 miles from Decatur, Alabama at river mile 274.9. They are 15 miles above the Wilson Locks and 74.1 miles below Guntersville Lock.
Built in 1963, the main lock at Wheeler is 600 x 110. It takes 10 minutes to fill or empty the chamber of its 25 million gallon capacity. The auxiliary lock, built in 1934, is 400 x 60. Both locks have a maximum lift of 51.5 ft. and an average lift of 45 ft.
Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page 13
Guntersville Lock - Guntersville Lock is located at Tennessee River mile 349, nine miles downstream from the city of Guntersville, Alabama. It is 75.3 miles downstream from Nickajack Lock and 74.1 miles above the Wheeler Locks.
Put into operation in 1965, Guntersvilles main lock is 600 x 110.
It takes 10 minutes to fill the chamber to its 22 million gallon capacity and 11 minutes to empty it. The auxiliary lock, built in 1937, is 360 x 60 and holds 7 million gallons of water. Its fill and empty times are both 20 minutes.
Nickajack Lock - Nickajack Lock is located 35 miles west of Chattanooga, Tennessee near the city of Jasper at river mile 424.7. It is 46.3 miles below Chickamauga Lock and 75.3 miles above Guntersville Lock.
Construction began on the 600 x 110 Nickajack Auxiliary Lock in March of 1964.
TVA completed it for operation in December 1967. The foundation for an 800 ft.
long main lock was also laid, but it remains incomplete. This lock will not be completed until the amount of traffic exceeds the capacity of the current auxiliary lock.
Chickamauga Lock & Dam - Chickamauga Lock and Dam is located at mile 471 of the Tennessee River in the port of Chattanooga, Tennessee. TVA built the project in the 1930s.
The lock was placed in temporary operation in 1938 and was completed in 1940. The lock chamber measures 360 x 60. Chickamauga Lock Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page 14
has a history of problems associated with concrete expansion. A study conducted by the COE recommended the construction of a new 600 x 110 lock chamber. The existing lock requires aggressive maintenance to confront its Alkali Aggregate Reaction (AAR) problem. This expansion of concrete features is causing misalignment of mechanical components and would eventually cause the lock to be closed. Congress has authorized construction of a 600 x 110 replacement lock riverward of the existing structure which will remove four of the existing spillway bays. Project construction began in 2004. The COE currently projects the entire lock project could be completed by 2013, pending congressional funding.
Watts Bar Lock - Watts Bar Lock is located near Decatur, Tennessee at Tennessee River mile 529.9.
It is approximately halfway between Chattanooga and Knoxville. The lock is 72.4 miles downstream from Fort Loudoun Lock and 58.9 miles above Chickamauga Lock. Built in 1942, the locks dimensions are 360 x 60.
Fort Loudoun Lock - Fort Loudoun Lock is located near Lenoir City, Tennessee, some 55 miles downstream from Knoxville.
It is at Tennessee River mile 602.3, some 73.4 miles upstream of Watts Bar Lock. Completed in 1944, the locks dimensions are 360 x 60.
Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page 15
2.6 Tennessee Department of Transportation The Tennessee Department of Transportation (TDOT) was established in 1972 to provide the citizens of Tennessee with an efficient and economical transportation system. It was during this initial formation that the Transportation Act of 1972 was passed by the Tennessee State Legislative establishing the Bureau of Industrial Marine and Watercraft Transportation (Bureau).
This formally moved TDOT into the area of water transportation. The Bureaus purpose was to provide a water transportation system which would efficiently serve the movement of goods and people, and provide for the implementation of statewide social, economic, and recreational goals while maintaining the states ecological and environmental objectives.
In 1987, TDOT reorganized forming the Public Transportation, Waterways and Rail Division.
This division was divided into two offices: the Office of Public Transportation and the Office of Rail & Water Transportation.
- The Office of Public Transportation The Office of Public Transportation has responsibility for transit planning, capital and operating assistance to non-urbanized and urbanized areas, elderly and disabled transportation, statewide ridesharing, development of park and ride lots, promotion of efficient transit systems through the coordination of available resources, and research and technical assistance in all aspects of public transportation.
- The Office of Rail & Water Transportation The Office of Rail & Water Transportation oversees short line railroad track and bridge rehabilitation, railroad track and bridge needs assessments, and offers assistance to the inland waterways of Tennessee. In prior years, a number of waterway assessment studies have been conducted by this TDOT division, including such topics as river port development, transportation on the waterways, a feasibility study and master plan, Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page 16
economic impacts of waterways, development and management of ports, and most recently, a Tennessee Lake and Rivers Resource Booklet.
In the 1990s, the Public Transportation, Waterways and Rail Division created the Office of Rail Safety, which took over the former Public Service Commissions (PSC) railroad regulatory functions, as well as grade crossing safety. This Office was divided into two sections: the Railroad Regulatory Section and the Grade Crossing Safety Section.
- Railroad Regulatory Section The Railroad Regulatory Section partners with the Federal Railroad Administration (FRA) to enforce Federal Railroad Law (CFR Part 49) and oversees railroad safety programs, inspections, new construction, and operating programs & procedures. The Railroad Regulatory Section is a Tennessee Emergency Management Agency (TEMA) responder for railroad emergencies in Tennessee.
- Grade Crossing Safety Section The Grade Crossing Safety Section oversees railroad crossing inventories, closures, signal reviews, standards and related task force and work groups.
The Public Transportation, Waterways and Rail Division is currently undergoing another structural reorganization. In October, 2006, the Grade Crossing Safety Section was relocated to TDOTs Maintenance Division. In July, 2007, the Railroad Regulatory Section will be relocated and become part of TDOTs Chief Engineers staff. The Office of Public Transportation and the Office of Rail & Water Transportation will continue to be a joint division, with the Office of Rail
& Water continuing to oversee short line railroads, inland waterways, as well as the newly added functions of freight transportation and the state safety oversight program for fixed rail guide-way Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page 17
systems. This new division will report directly to the Commissioner of TDOT, but the organizational flow has yet to be completed.
2.7 Transportation Overview Economic development opportunities are enhanced by connectivity to several modes of transportation. As shown in Exhibit 2.3, the State of Tennessee has a comprehensive intermodal transportation system of inland waterways, interstate highways, and railroads. According to TDOT, the state has nearly 770 miles of shortline railroads and 13,752 miles of state-maintained highways, representing 16 percent of the total highway miles within the state and carrying 72 percent of the traffic. Included in the state highway system are 1,074 miles of interstate highways. Although the interstate system makes up just over one percent of the total highway mileage, it carries one quarter of all the traffic in Tennessee.
Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page 18
CSXT KCS CSXT NS NS NS NS CSXT NS BNSF NS NS NS NS CSXT NS NS NS NS NS NS NS NS NS CSXT CSXT CSXT CSXT CSXT CSXT CSXT NS NS CSXT NS CSXT NS NS CSXT CSXT CSXT CSXT NS NS NS CSXT CSXT CN CN CN BNSF KCS KCS BNSF KCS UP UP UP UP UP UP UP UP UP BNSF BNSF BNSF UP UP UP UP BNSF BNSF UP CN CN CSXT UP UP CN UP BNSF NS CSXT CN CSXT CSXT NS CSXT CSXT NS NS NS NS NS NS CSXT CSXT NS NS NS CSXT CSXT CSXT CSXT NS CSXT CSXT CSXT CSXT CSXT NS CSXT NS NS CSXT N S CN NS NS Tenn-Tom Waterway B l a c k Wa r ri o r R i v e r Te n n e s s e e R i v e r Tennessee River C u m b e r l a n d R i v e r T e n n e s see R i v e r Mis sis sippi River O h i o R i v e r Alabama Tuscaloosa Florence Pine Bluff Jonesboro Tennessee Waterway Assessment Study Hanson Professional Services Page 19 Illinois to Chicago Indiana to Indianapolis to Cincinnati Kentucky to St. Louis Mt. Vernon to Huntington Louisville Missouri Evansville Lexington Farmington Owensboro to Springfield Virginia Paducah Poplar Bluff West Plain Nashville North Carolina Knoxville NS Arkansas Ashville to Charlotte Memphis Chattanooga Greenville to Little Rock CN Decatur South Carolina Columbia Atlanta Augusta Birmingham to Charleston Columbus to Texarkana Georgia to Columbus Mississippi to Jackson to Meridian Exhibit 2.3 Transportation Routes - State of Tennessee
3.0 WATERBORNE COMMERCE Barges continue to be used today for the movement of large quantity bulk commodities and raw materials on the nations inland waterway system (Exhibit 3.1). According to the COE, nearly 630 million tons or 15% of the nations freight moved on the inland waterways in 2004 with dominant commodities including coal, petroleum products, raw materials and grain, as shown in Exhibit 3.2.
River transportation produces many benefits. It provides a cost-effective, energy efficient and environmentally sound alternative to land-based transportation modes as shown in Exhibits 3.3 and 3.4. In addition to the distinct advantages in energy savings, barge transportation helps relieve highway congestion and generates far less air and noise pollution, per ton of freight moved, than truck or rail. The movement of commerce on the nations waterways greatly reduces wear and tear on public highways and bridges. Statistics also show that waterborne transportation significantly reduces the number of traffic accidents and, by extension, the number of traffic fatalities, by reducing the number of vehicles on the highways and at rail crossings.
Over 15% of the nations freight is moved on inland waterways for less than 2% of the nations freight movement cost. According to research by the Tennessee Valley Authority, this cargo moves at an average transportation savings of $10.67 per ton over the cost of shipping by alternative modes. This translates into over $7 billion annually in transportation savings to the economy of the United States.
To carry goods and commodities, the inland river transportation system utilizes barges that are linked together to form tows. Each tow is pushed with a towboat. A standard jumbo hopper barge is 195 feet long by 35 feet wide. Each barge carries the equivalent Standard Hopper Barge and Towboat of 15 to 20 rail car loads or 50 to 60 truck loads of material.
Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page 20
Minneapolis Chicago Cleveland Pittsburgh Kansas City St. Louis Louisville Paducah Tulsa Nashville Knoxville Little Rock Memphis Chattanooga Atlanta Birmingham Montgomery Natchez New Orleans Mobile Exhibit 3-1. Inland Waterway System Tennessee Waterway Assessment Study Hanson Professional Services Page 21
National Inland Waterway System Trends in Commerce 580 590 600 610 620 630 640 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 Millions of Tons National Inland Waterway System Commerce By Commodity Other 2%
Primary Manufactured Goods 5%
Coal 28%
Oil & Oil Products 24%
Chemicals 8%
Crude Materials 20%
Food & Farm 13%
Exhibit 3-2. 2004 National Inland Waterway System -
Trends in Commerce Tennessee Waterway Assessment Study Hanson Professional Services Page 22
Exhibit 3-3. Comparisons of Transportation Modes Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page 23
Exhibit 3-4. Fuel Efficiency by Transportation Mode Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page 24
Where river transportation exists as a viable alternative, rail freight rates typically must be competitive with waterway shipping rates. Where a river does not exist as an alternative, rail freight rates may rise to be competitive with truck rates. According to the U.S. Army Corps of Engineers (COE) 2004 Civil Works Strategic Plan, the navigation infrastructure of waterborne commerce saves $7 billion annually in transportation costs by providing a more energy-efficient and environmentally friendly form of conveyance than rail or road transportation modes.
3.1 Waterborne Commodity Movements Exhibit 3-5 characterizes the total movement of commodities on the Mississippi River. Exhibits 3-6 and 3-7 show the total movement of commodities in 2004 through the State of Tennessee on the Tennessee and Cumberland Rivers, respectively. Exhibit 3-8 shows each commodity as both a percentage of the total tonnage of all commodities and as a percentage of the total value of all commodities.
According to the COE, over 31 million tons of commodities worth over $4.2 billion moved to, from and within the State of Tennessee in 2004. 3.2 million tons of these commodities were shipped out of the state. A sizeable portion of this outbound tonnage consisted of petroleum and aggregates. 61% of the 25.2 millions tons of commodities shipped to Tennessee was coal, with three Tennessee Valley Authority power plants receiving almost 14.2 million tons for electrical power generation.
Neighboring state Kentucky was Tennessees top trading partner with over 15.1 million tons moving on barges between the states in 2004 as shown in the table on page 28. Tennessee supplied Kentucky with gasoline and gypsum, while Kentucky supplied most of the coal to Tennessees power plants.
Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page 25
Mississippi River Trends in Commerce 295 300 305 310 315 320 325 330 335 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 Millions of Tons Mississippi River Commerce by Commodity Oil & Oil Products 25%
Coal 13%
Other 1%
Food & Farm 24%
Primary Manufactured Goods 7%
Crude Materials 18%
Chemicals 12%
Exhibit 3-5. 2004 Trends in Commerce on the Mississippi River Tennessee Waterway Assessment Study Hanson Professional Services Page 26
Tennessee River Trends in Commerce 40 42 44 46 48 50 52 54 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 Millions of Short Tons Tennessee River Commerce by Commodity Other Products Food & Farm Primary Manufactured Goods 6%
Crude Materials 33%
Coal 38%
13%
10%
Exhibit 3-6. 2004 Trends in Commerce on the Tennessee River Tennessee Waterway Assessment Study Hanson Professional Services Page 27
Cumberland River Trends in Commerce 5
10 15 20 25 30 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 Millions of Tons Cumberland River Commerce by Commodity Manufactured Goods Food & Farm 7%
Petro & Petro Products 2%
Coal 51%
2%
Other 2%
Crude Materials 36%
Exhibit 3-7. 2004 Trends in Commerce on the Cumberland River Tennessee Waterway Assessment Study Hanson Professional Services Page 28
Aggregates 26%
Petroleum 7%
Coal 48%
Other 5%
Ores/Minerals 4%
Grain 3%
Iron/Steel 4%
Chemicals 3%
% by Tons Other 23%
Coal 14%
Petroleum 10%
Iron/Steel 29%
Aggregates 7%
Ores/Minerals 3%
Grain 3%
Chemicals 11%
% by Value Exhibit 3-8. 2004 Commodities Moved To, From and Within Tennessee Tennessee Waterway Assessment Study Hanson Professional Services Page 29
Tennessee 2004 Commodities Shipped by Barge to and from Other States (values in millions of dollars)
Shipments To Tons Value Top Commodity Shipments From Tons Value Top Commodity Kentucky 956,205
$247 Petroleum Kentucky 14,351,449
$820 Coal Louisiana 488,553
$84 Grain Illinois 6,635,234
$374 Coal Alabama 461,247
$297 Iron/Steel Louisiana 2,341,884
$725 Ores/Minerals Arkansas 419,421
$156 Aggregates Missouri 463,791
$24 Others Indiana 342,995
$60 Aggregates Alabama 277,462
$84 Others Source: U.S. Army Corps of Engineers Waterborne Commerce Statistics Information on commodities moving through a specific waterway segment is useful in characterizing the nature and level of local port activity and commerce. In the United States, locations on rivers are designated by river mile (RM), with mile zero at the mouth or downstream end of all rivers except the Ohio River. (River miles on the Ohio begin at mile zero in Pittsburgh where the confluence of the Monongahela and Allegheny Rivers form the Ohio, and end at mile 981 where the Ohio joins the Mississippi River near Cairo, Illinois.) Reference is made to river miles in the following narratives to define specific river segments for further analysis of cargos and commodities being loaded into barges (outbound) or being offloaded from barges (inbound) in these segments. The river mile segments selected represent that which originates or terminates on pools in the study area.
Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page 30
3.1.1 Mississippi River The Mississippi River borders the western boundary of the State of Tennessee from RM 700 to RM 925. Trends in inbound and outbound cargo IL movements on this segment of the River are shown in Exhibits 3-9 and 3-10. Inbound metal shipments increased by 23% in the one year period from 2003 to 2004. Some of this increase may be attributable to the expansion of Nucor Steels Arkansas division, located along the banks of the Mississippi, and increased AR production at Nucor-Yamato Steel Company.
Outbound commodities are varied in nature.
Grain and feed are the dominant outbound commodity and is showing a trend for continual growth in shipments.
3.1.2 Tennessee River MO KY TN MS Mississippi River Ohio River Tennesse e River Memphis Paducah River Mile 925 River Mile 700 The Tennessee River is formed at the confluence of the Holston and French Broad Rivers on the east side of Knoxville, Tennessee. From Knoxville, it flows southwest through East Tennessee toward Chattanooga before crossing into Alabama. It loops TN KY MS GA Tenn-Tom Waterway Tennessee River Tennessee River C u m b er l a n d R i ve r Tennessee River River Mile 66 River Mile 652 River Mile 416 River Mile 210 Knoxville Chattanooga Florence Decatur T
T T
T T
T T
T Wilson Lock Mile 259.4 Wheeler Lock Mile 274.9 Guntersville Lock Mile 349.0 Nickajack Lock Mile 424.7 Watts Bar Lock Mile 529.9 Chickamauga Lock Mile 471.0 through northern Alabama and Fort Loudoun Lock Mile 602.3 eventually forms a small part of the Pickwick Lock Mile 206.7 state's border with Mississippi, before returning to Tennessee. At this point, the AL river flows almost due north into Kentucky and finally empties into the Ohio River near Paducah, KY. Inbound and outbound commodities were analyzed for the segments of the river that fall in the State of Tennessee. This Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page 31
Inbound Tonnage Tons x 1,000 8,000 6,000 4,000 2,000 0
Metals Sand, Gravel &
Aggregates Petroleum 2000 2001 2002 2003 2004 Metals 5,742 4,768 4,695 4,850 6,261 Sand, Gravel &
Aggregates 4,554 4,197 4,745 4,066 3,867 Petroleum 2,495 2,606 1,895 2,051 2,222 Other 1,212 1,095 929 1,014 1,090 Other Other Inbound Tonnage Detailed 0
100 200 300 400 500 600 700 2000 2001 2002 2003 2004 Tons x 1,000 Fertilizer Chemicals Coal Grain/Feed Miscellaneous Exhibit 3-9. 2004 Inbound Tonnage on Mississippi River -
River Miles 700 - 925 Tennessee Waterway Assessment Study Hanson Professional Services Page 32
Outbound Tonnage 1,000 2,000 3,000 4,000 5,000 6,000 Tons x 1,000 Grain/Feed Metals Other Other Outbound Tonnage Detailed 0
50 100 150 200 250 300 350 400 450 2000 2001 2002 2003 2004 Tons x 1,000 Petroleum Fertilizer Sand, Gravel &
Aggregates Forest Products Chemicals Miscellaneous Grain/Feed 3,836 4,128 4,031 5,047 4,882 Metals 954 853 852 904 955 Other 796 509 836 674 632 2000 2001 2002 2003 2004 Exhibit 3-10. 2004 Outbound Tonnage on Mississippi River -
River Miles 700 - 925 Tennessee Waterway Assessment Study Hanson Professional Services Page 33
encompasses river miles66-210 on the western portion of the state (West TN River) and river miles 416 to 652 which is the portion of the river that runs from the Nickajack Dam area, close to Chattanooga, to Knoxville (East TN River).
3.1.2.1 West TN River - River Miles 66 - 210 The West Tennessee segment of the River is the busiest section of the Tennessee River. Here Tennessee River traffic is joined by traffic passing through from the Cumberland, Ohio, or upper Mississippi Rivers destined for Alabama waterways or the Gulf of Mexico, or vice versa. A wide variety of waterborne commodities move on this section. Commodities originating or terminating on the lower reach of the Tennessee River include sand and gravel, coal, chemicals, petroleum, and ores and minerals.
Trends in commerce on this river segment are shown in Exhibits 3-11 and 3-12. Coal is the dominant commodity on this river segment shipped primarily to the power plants. In analyzing the commodity trends for the years 2000-2004, it is worth noting that even though coal is responsible for the primary inbound tonnage, metals have shown a 60% increase in tonnage over this period; 31% of this increase occurring from 2003 to 2004. Overall, inbound tonnage on this river segment has increased by 14% over the five year period analyzed. On the other hand, outbound tonnage has incurred a significant decrease over this same period attributable to the decline in shipments of sand, gravel, and aggregates.
3.1.2.2 East TN River - River Miles 416 - 652 River miles 416 to 652 on the Tennessee River constitute the segment of the river that runs through the eastern half of the state from near Chattanooga to Knoxville. Exhibits 3-13 and 3-14 show trends in commodities on this river segment. Sand, gravel and aggregates are the dominant commodities. Since 2000, overall tonnage has declined on the East Tennessee River. This decline is likely attributable to the structural problems of the Chickamauga Lock. In spite Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page 34
West Tennessee River Inbound Volume 0
500 1,000 1,500 2,000 2,500 3,000 3,500 4,000 Tons x 1,000 Coal Other Coal 3,095 3,131 3,641 3,740 3,562 Other 702 794 805 715 870 2000 2001 2002 2003 2004 West Tennessee River Inbound Volume-Other Commodities 0
100 200 300 400 500 600 2000 2001 2002 2003 2004 Tons x 1,000 Metals Petroleum Chemicals Sand, Gravel & Aggregates Fertilizer Grain/Feed Miscellaneous Exhibit 3-11. 2004 Tennessee West River Inbound Tonnage -
River Miles 66 - 210 Tennessee Waterway Assessment Study Hanson Professional Services Page 35
West Tennessee River Outbound Volume 0
200 400 600 800 1,000 1,200 Tons x 1,000 Sand, Gravel & Aggregates Other Sand, Gravel & Aggregates 739 945 1,013 471 277 Other 155 149 111 122 144 2000 2001 2002 2003 2004 West Tennessee River Outbound Volume-Other Commodities 0
20 40 60 80 100 120 140 160 2000 2001 2002 2003 2004 Tons (x1000)
Grain/Feed Miscellaneous Exhibit 3-12. 2004 Tennessee West River Outbound Tonnage -
River Miles 66 - 210 Tennessee Waterway Assessment Study Hanson Professional Services Page 36
East Tennessee River Inbound Volume Tons x 1,000 1,400 0
200 400 600 800 1,000 1,200 Sand, Gravel and Aggregates 928 2000 1,282 2001 1,154 2002 1,084 2003 905 2004 Petroleum 727 562 602 536 597 Grain/Feed 689 512 639 554 347 Other 490 415 352 450 419 Sand, Gravel and Aggregates Petroleum Grain/Feed Other East Tennessee River Inbound Volume-Other Commodities 0
50 100 150 200 250 300 350 2000 2001 2002 2003 2004 Tons x 1,000 Metals Chemicals Fertilizer Miscellaneous Exhibit 3-13. 2004 East Tennessee River Inbound Tonnage -
River Miles 416 - 652 Tennessee Waterway Assessment Study Hanson Professional Services Page 37
East Tennessee River Outbound Volume 0
100 200 300 400 Tons x 1,000 Metals 367 217 242 308 358 Chemicals 50 90 137 119 137 Grain/Feed 278 229 147 100 73 Sand, Gravel & Aggregates 47 209 252 243 69 Other 26 4
12 34 62 1
2 3
4 5
Metals Chemicals Grain/Feed Sand, Gravel & Aggregates Other East Tennessee River Outbound Volume-Other Commodities 0
10 20 30 40 50 60 70 2000 2001 2002 2003 2004 Tons x 1,000 Fert. & Mixes NEC M iscellaneous Exhibit 3-14. 2004 Tennessee East River Outbound Tonnage -
River Miles 416 - 652 Tennessee Waterway Assessment Study Hanson Professional Services Page 38
Tennessee River Cumberland River Nashville TN KY River Mile 380 River Mile 100 Cheatham Lock Mile 148.7 Old Hickory Lock Mile 216.2 Cordell Hull Lock Mile 313.5 T
T T
of this decline, there has been a resurgence over the five year period from 2000 to 2004 in the outbound shipments of metals, chemicals, and fertilizer. These three commodity groups constitute a 21% increase in shipments originating from this East Tennessee River segment from 2000 to 2004.
3.1.3 Cumberland River The Cumberland River flows nearly 700 miles from east to west, through the northern section of Tennessee. It dips down to Nashville, then back northwestward into Kentucky to its mouth on the Ohio River. River miles 100 to 380 were analyzed for inbound and outbound commodity tonnage. These river miles signify the first (RM 100) and last (RM 380) terminal locations in the study area on the Cumberland River. Trends in commerce on these river segments are shown in Exhibits 3-15 and 3-16. During the five year period shown, annual tonnage varied from a low in 2003 of 15.8 million to over 18 million in 2004. Coal is by far the primary commodity moving on this river segment.
Coal is the dominant inbound commodity unloaded primarily at power plants followed by sand, gravel and aggregates. A closer examination of these two inbound commodities shows a 9%
increase over the five year period from 2001 to 2004. Other commodities received in this river segment are diverse in nature as well as tonnage. Outbound shipments primarily consist of sand, gravel, aggregates, grain, and metals. Though outbound tonnage has varied over this same five year period, the period from 2003 to 2004 showed an 8% increase in the outbound shipment of metals as well as a 2% increase in sand, gravel, and aggregates. It is also worth noting that the shipment of metals has increased by 31% since 2001.
Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page 39
Cumberland River Inbound Volume 0
2,000 4,000 6,000 8,000 10,000 12,000 Tons x 1,000 Coal 9,823 9,760 10,726 9,092 10,958 Sand, Gravel, Aggregates 4,336 4,563 4,307 4,016 4,618 Other 1,771 1,660 1,536 1,445 1,397 2000 2001 2002 2003 2004 Coal Sand, Gravel, Aggregates Other Cumberland River Inbound Volume - Other Commodities 0
100 200 300 400 500 600 700 800 900 2000 2001 2002 2003 2004 Tons x 1,000 Metals Petroleum Fertilizer Chemicals Grain Miscellaneous Exhibit 3-15. 2004 Cumberland River Inbound Tonnage -
River Miles 100 - 380 Tennessee Waterway Assessment Study Hanson Professional Services Page 40
Cumberland River Outbound Volume 0
200 400 600 800 1,000 1,200 Tons x 1,000 Sand, Gravel, Aggregates Grain Metals Other Sand, Gravel, Aggregates 965 690 839 711 724 Grain 207 366 262 333 329 Metals 239 223 241 206 223 Other 126 145 5
0 0
2000 2001 2002 2003 2004 Cumberland River Outbound Volume - Other Commodities 0
200 400 600 800 1,000 1,200 2000 2001 2002 2003 2004 Tons x 1,000 Metals Petroleum Grain Fertilizer Chemicals Miscellaneous Exhibit 3-16. 2004 Cumberland River Outbound Tonnage -
River Miles 100 - 380 Tennessee Waterway Assessment Study Hanson Professional Services Page 41
The scope of work for this portion of the Tennessee Waterway Assessment Study does not include a detailed analysis that would indicate reasons for fluctuations in commodity volumes.
Such evaluations would require time and budget beyond that available in Phase 1 of this study.
Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page 42
4.0 RIVER TERMINAL INVENTORY Port development can be an important part of the economic development strategy for a region, providing land which has access to highway, rail and river transportation. By definition, a port is a segment of navigable waterway in which commercial activity takes place. A port encompasses land and facilities along a defined segment of a river, whereas a river terminal is a point at which barges are loaded and/or unloaded. A port complex may include both public and private terminals as well as industrial sites, railroads, warehousing and other infrastructure. In the context of this assessment, ports are important resources for the state and region, as well as their respective local areas.
4.1 Inventory Methodology The terminal inventory for the Study was conducted to identify the terminals within the borders of Tennessee and any direct competition just over the borders. To accomplish this task, terminal information was compiled from state agencies, associations, federal government, private-sector sources and personal contacts. The raw information was then compared to eliminate duplicates, clarify discrepancies and identify locations where field visits are needed.
Terminals located directly across the Mississippi River from Tennessee were included in the inventory of terminals to properly quantity the number of terminals in the area. Other areas outside of the borders of Tennessee were identified due to the large scale of operations complementing or competing with terminals in Tennessee. These areas are the Hickman-Fulton County Riverport Authority in Hickman, KY, New Madrid County Port Authority in Missouri, Pemiscot County Port Authority in Missouri and the Yellow Creek Inland Port in Iuka, MS.
Other terminals and ports were considered to be outside of the Tennessee market area and were not inventoried for this project.
Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page 43
4.2 Terminal Categories In the context of this Assessment, terminals are categorized by ownership, operation and use.
Terminal ownership can be characterized as public or private, as can operation. Terminals can be categorized in terms of use as either special purpose or general purpose. The categories are further explained in the following sections.
4.2.1 River Terminal Ownership River terminal ownership falls into two broad categories - public and private. Public ownership is where the terminal is owned by a public entity such as a port authority, unit of local government or a state. Private ownership is where a terminal is owned by a private corporation.
In the State of Tennessee, there are four publicly owned and eleven privately owned general cargo terminals as shown in the table on page 58.
4.2.2 River Terminal Operation Public port authorities may develop and construct facilities, retain ownership of the facilities, but contract or lease the facility to a private company which provides day-to-day operations, marketing and management (private operation). In the case of Tennessee, all of the publicly owned terminals are operated by private entities.
When a terminal facility is operated by its owner, control of the strategic direction and pricing of services is retained by the owner. The public entity now has the responsibility for staffing, purchasing and maintaining equipment, marketing and the myriad of other duties associated with operating a river terminal.
Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page 44
4.2.3 River Terminal Use Special purpose facilities are typically built to be very efficient for moving a specific commodity either inbound or outbound. For example, pneumatic systems, special pipelines, conveyors and special crane systems are often used in single-purpose applications such as loading grain, loading petroleum products, unloading cement, unloading liquid fertilizer or for certain steel or mineral products. Special purpose terminals may have little or no versatility with respect to moving other types of cargoes, but are typically very efficient for their special purpose. These terminals are most often seen at an industry, mine, power plant, or for some other on-site need, and are typically privately owned.
General purpose facilities are usually versatile and can be used for a wide variety of applications such as loading or unloading steel coils, pipe, machinery, forest products, or bulk materials.
Equipment may include, for example, a mobile crane which can be rigged with a bucket, spreader bar, hook, clamp, magnet or other cargo handling equipment to move the cargo from the dock into short-term storage. A general purpose terminal is constructed for versatility rather than specialization. Some degree of efficiency may be sacrificed when the general purpose facility is compared to a special purpose terminal built and operated for maximizing single cargo efficiency.
To enhance the transportation advantages of river front industrial sites, a public port authority may market some sites with direct river access for industries which require a private, special purpose terminal as part of their facility, and the port authority may also develop a public general purpose terminal for industries which may want to take advantage of the economics of waterborne transportation, but which do not generate sufficient tonnage to justify construction of their own private terminal.
Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page 45
4.2.3.1 Special Purpose Terminals Liquid Terminals - Liquids such as fuel, asphalt, other petroleum products, chemicals for industrial processing, and liquid fertilizers commonly move by barge. Most are loaded and unloaded at privately owned special purpose terminals such as those shown in Exhibit 4-1.
Liquids are typically offloaded using pumps mounted on the tank barge. Heaters may also be mounted on the barge, or the barge may be rigged to receive steam from a land-based source where heat is required to adjust the viscosity of the material being offloaded. Asphalt, for example, may require heating, especially in cold weather. Liquid storage tanks do not necessarily need to be located directly at the rivers edge and, to conserve river frontage for other uses, are often located some distance from the river bank. A liquids dock may be very simple, including adequate barge mooring structures as well as a structure to provide personnel access and hose handling. Hard piping on the barge is connected to hard piping on the land with a specially-fitted, flexible hose.
Grain Terminals - Grain terminals in the market area are shown in Exhibit 4-2. Most are privately owned and operated. Few, mostly in the Memphis area, are owned by a public river port and operated by a private sector firm which leases the facilities from the public entity. The grower will typically take his grain to the point at which he receives the best return, considering the price paid and the cost for delivery to the purchasing facility. Waterborne transportation generally costs less than land-based modes and grain prices at river facilities are often attractive to growers. Facilities for loading grain typically include receiving and storage structures, some form of reclaim equipment or device, and conveyance to the barge. A spout directs grain into the proper area of the barge. Some method for handling barge covers and possibly for moving the barge during loading operations may also be provided. Grain may be unloaded using a variety of devices ranging from special mechanical equipment to a general purpose crane rigged with a clam shell bucket.
Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page 46
CSXT NS NS NS NS NS CSXT CN BNSF KCS UP UP UP UP UP BNSF BNSF UP UP UP CN CN CSXT CSXT NS CSXT CSXT NS NS NS NS CSXT CSXT CSXT CSXT CSXT NS CN NS y
a w
r eta W
m o
T n
n e
T Tennessee River r
e vi R
e e
ss e
n n
e T
Cumberland River Tennessee River ss i
M ss i
r e
vi R
ip pi Ohio River T
T T
T T
T T
T T
T T
T T
T T
T Tennessee Waterway Assessment Study Hanson Professional Services Exhibit 4-1. Liquid Terminals
- 1. Ergon Terminal
- 2. Ashland Chemical
- 3. Brenntag Mid-South
- 4. Fleischmanns Molasses
- 5. Valero Refinery
- 6. Suburban Propane, W.M. Barr &
- 7. Valero Memphis Terminals
- 8. Trumbull Asphalt Co: Marathon
- 9. Vertex Industries
- 10. Western Tar Products
- 11. Valero West Memphis Terminals
- 12. Warren Unilube (Coastal), West
- 13. Lion Oil Co., Memphis Terminal
- 15. American Commercial
- 18. Paymaster Oil Mill
- 19. Continental Oil Co. Terminal
- 20. AG Distributors, Caruthersville
- 21. Marine Oil Co.
- 22. Koch Pavement Solutions, New
- 23. River Bend Ag., New Madrid
- 24. Sinclair Oil Mississippi River Terminals Tennessee CN Lauderdale Madison Allen Ballard Calloway Livingston Lyon McCracken Marshall Monroe Simpson Catoosa Murray Whitfield Alcorn Prentiss Tippah Tishomingo Union Craighead Crittenden Cross Mississippi Poinsett Bollinger Butler Dunklin Stoddard Alexander Hardin Johnson Massac Pope Pulaski to Columbus to Chicago Chattanooga Paducah Florence Jonesboro T
1-2 1-10 11-12 18-19 1
2-4 5
Illinois to St. Louis to Louisville Kentucky Missouri to Cincinnati Cape Union Girardeau Madison Crittenden Taylor Casey Edmonson Hart Hopkins Butler Green Caldwell Muhlenberg Adair Pulaski Warren Christian Wayne Scott to Springfield Metcalfe Logan Barren Russell Todd Mississippi Carlisle Cumberland Wayne McCreary Poplar Bluff Trigg Whitley Graves Clinton Hickman 22-24 New Madrid Fulton Clay Pemiscot Nashville 3
Greene 20-21 6-8 Knoxville Graham North Cherokee 13-17 Carolina Memphis St. Francis Fannin Dade Jackson to Little Rock Benton Union Lee Huntsville De Soto Limestone Walker Gilmer Tate Marshall Colbert Decatur Tunica Lumpkin Arkansas Chattooga Gordon Pickens Franklin Lawrence Morgan DeKalb Dawson Marshall Mississippi Georgia to Atlanta Alabama Tennessee River Terminals
- 1. Koch Materials, Inc. - Asphalt
- 14. Exxon Company USA Petroleum Transfer and Storage Division
- 2. Ergon, Inc.
Terminals, Memphis Dock
- 3. Marathon Ashland Petroleum Terminal
- 4. Star Interprises
- 16. ED&F Man (Westwat Terminals)
Molasses - Memphis Terminal
- 5. ADM, Chattanooga Oil Refining Dock
- 17. Lucy Woodstock Utility Terminal, Memphis Dock
- 6. Marathon-Ashland Petroleum Co.
- 7. Unocal Corps.
- 8. Volunteer Asphalt Company Dock Corporation Cumberland River Terminals
- 1. Southern State Asphalt Company Madrid Dock Memphis Dock
- 2. Marathon-Ashland Petroleum, LLC Liquid Fertilizer Dock Dock
- 3. Ergon, Inc.
Page 47
CSXT NS NS NS NS NS CSXT CN BNSF KCS UP UP UP UP UP BNSF BNSF UP UP UP CN CN CSXT CSXT NS CSXT CSXT NS NS NS NS CSXT CSXT CSXT CSXT CSXT NS CN NS y
a w
r eta W
m o
T n
n e
T Tennessee River r
e vi R
e e
ss e
n n
e T
Cumberland River Tennessee River ss i
M ss i
r e
vi R
ip pi Ohio River T
T T
T T
T T
T T
T T
T T
T T
T Tennessee Waterway Assessment Study Hanson Professional Services Tennessee CN Lauderdale Madison Allen Ballard Calloway Livingston Lyon McCracken Marshall Monroe Simpson Catoosa Murray Whitfield Alcorn Prentiss Tippah Tishomingo Union Craighead Crittenden Cross Mississippi Poinsett Bollinger Butler Dunklin Stoddard Alexander Hardin Johnson Massac Pope Pulaski to Columbus to Chicago Chattanooga Paducah Florence Jonesboro T
9 10-11 12-14 17 2-4
- 4. Kinder Morgan
- 5. Cargill Inc. (Wet Corn Facility)
- 6. Weiners Grain
- 7. Cargill Memphis Soybean Plant
- 9. Kinder Morgan
- 10. Bunge Corp. Memphis Elevator
- 11. Cargill (prev. Continental Grain )
- Memphis Grain Elevator
- 12. Bunge Corp., Osceola Riverside
- 13. Bunge Corp., Osceola Landside
- 14. Poinsett Rice & Grain
- 15. Cargill AgHorizons, Hales Point
- 16. West Tennessee Terminals Exhibit 4-2. Grain Terminals
- 17. Bunge Corp., Huffman Elevator
- 18. Bunge Corp., Heloise Elevator
- 19. Consolidated Grain and Barge
- 20. Bunge Corp., Boothspoint
- 21. Missouri Grain
- 22. Bunge Corp., Caruthersville
- 24. Cargill AgHorizons, Tiptonville
- 25. Bunge Corp., Linda Grain
- 26. New Madrid County Port Dock
- 27. Bunge Corp., Hickman Grain
- 28. Fulton County Grain Co.
- 29. Cargill AgHorizons, Hickman
- 30. Consolidated Grain and Barge Mississippi River Terminals Illinois to St. Louis to Louisville Kentucky Missouri to Cincinnati Cape Union Girardeau Madison Crittenden Taylor Casey Edmonson Hart Hopkins Butler Green Caldwell Muhlenberg Adair Pulaski Warren Christian Wayne Scott to Springfield Metcalfe Logan Barren Russell Todd Mississippi Carlisle Cumberland Wayne McCreary Poplar Bluff Trigg Whitley Graves Clinton Hickman 1
New Madrid 27-29 Fulton 25-26 24 Clay Pemiscot 21-23 Nashville 20 Greene 19 18 1
Knoxville 15-16 Graham North Cherokee Carolina 1-8 Memphis St. Francis Fannin Dade Jackson to Little Rock Benton Union Lee Huntsville De Soto Limestone Walker Gilmer Tate Marshall Colbert Decatur Tunica Lumpkin Arkansas Chattooga Gordon Pickens Franklin Lawrence Morgan DeKalb Dawson Marshall Mississippi Georgia to Atlanta Alabama Tennessee River Terminals
- 1. Cargill Ag Horizons
- 1. ADM
- 2. ADM Milling
- 2. ADM Dock
- 3. Cargill, Inc.
- 3. ADM
- 4. ADM, Chattanooga Oil Dock Refining Dock Cumberland River Terminals Co., Cottonwood Pt. Elev. Dock Dock Elevator Dock
- 8. Agriliance Dock
- 23. Consolidated Grain and Barge,
- 1. Hopkinsville Elevator Co.
Dock Caruthersville Dock Elevator Dock Elevator Dock Dock Dock Elevator Dock Elevator Dock Co., Dorena Elevator Dock Page 48
Dry Bulk Terminals - Dry bulk terminals shown in Exhibit 4-3 are involved in shipping or receiving sand, gravel, crushed stone, aggregates and other construction materials. Where aggregate and stone are loaded, a conveyor usually delivers material to the river front where it is channeled through a loading spout or chute into the barge, if the material is of a certain size and the drop is such that it will not damage the barge. Larger stone such as rip-rap may be placed with a crane or other mechanical device or may be dumped directly or via a chute if the drop is not too high.
Sand and Gravel Terminals - Sand and Gravel terminals, listed in Exhibit 4-4, typically receive cargo and store it in the open. The biggest consumer of sand and gravel is the cement industry and many cement manufacturers are located adjacent to sand and gravel terminals to take advantage of the close proximity.
Cement Terminals - Cement is moved in a variety of ways. Pneumatic equipment, mechanical devices or a general purpose crane rigged with a clam shell bucket may be used, but some methods of loading/unloading depend on the type of barge being used to carry the cement.
Exhibit 4-5 displays the cement terminals in the study area.
Fertilizer Terminals - Fertilizer terminals were also separated from dry bulk due to their high occurrence on the Mississippi River (Exhibit 4-6). There are terminals that handle fertilizer on the Cumberland and Tennessee Rivers. These were included in the dry bulk or general cargo designations due to the diverse product mix handled.
On-Site Terminals - On-site terminals in the area, shown in Exhibit 4-7, are generally privately owned and located at a power plant or manufacturing plant. These terminals move commodities such as coal, steel and other cargoes used specifically at that site. Types of docks and materials handling equipment vary. At power plants and other locations where coal is unloaded, the equipment used depends on the volume and rate of unloading capability required by the owner.
As with grain, equipment can vary from special high-speed mechanical unloading devices to a Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page 49
CSXT NS NS NS NS NS CSXT CN BNSF KCS UP UP UP UP UP BNSF BNSF UP UP UP CN CN CSXT CSXT NS CSXT CSXT NS NS NS NS CSXT CSXT CSXT CSXT CSXT NS CN NS y
a w
r eta W
m o
T n
n e
T Tennessee River r
e vi R
e e
ss e
n n
e T
Cumberland River Tennessee River ss i
M ss i
r e
vi R
ip pi Ohio River T
T T
T T
T T
T T
T T
T T
T T
T Tennessee Waterway Assessment Study Hanson Professional Services Mississippi River Terminals
- 1. Koch Materials
- 2. Drexel Chemicals
- 4. West Tennessee Terminals
- 5. Choctaw Transportation Co., Heloise Dock
- 6. Caruthersville Marine Service, Dock and Fleet
- 7. MFA, Caruthersville Dock
- 8. Oakley Missouri, Caruthersville Dock
- 9. New Madrid County Port Dock
- 10. Cargill AgHorizones, New Madrid Dry Exhibit 4-3. Dry Bulk Terminals Tennessee CN Lauderdale Madison Allen Ballard Calloway Livingston Lyon McCracken Marshall Monroe Simpson Catoosa Murray Whitfield Alcorn Prentiss Tippah Tishomingo Union Craighead Crittenden Cross Mississippi Poinsett Bollinger Butler Dunklin Stoddard Alexander Hardin Johnson Massac Pope Pulaski to Columbus to Chicago Chattanooga Paducah Florence Jonesboro T
1-2 3
6 7
9 Illinois to St. Louis to Louisville Kentucky Missouri to Cincinnati Cape Union Girardeau Madison Crittenden Taylor Casey Edmonson Hart Hopkins Butler Green Caldwell Muhlenberg Adair Pulaski Warren Christian Wayne Scott to Springfield Metcalfe Logan Barren Russell Todd Mississippi Carlisle Cumberland Wayne McCreary Poplar Bluff Trigg Whitley Graves Clinton Hickman 9-10 New Madrid Fulton Clay Pemiscot 6-8 1
Nashville Greene 2
4-5 Knoxville 8
Graham North 5
4 3
Cherokee Carolina Memphis St. Francis Fannin Dade Jackson to Little Rock Benton Union Lee Huntsville De Soto Limestone Walker Gilmer Tate Marshall Colbert Decatur Tunica Lumpkin Arkansas Chattooga Gordon Pickens Franklin Lawrence Morgan DeKalb Dawson Marshall Mississippi Georgia to Atlanta Alabama Tennessee River Terminals
- 1. Kinder Morgan (Hall-Buck Marine)
- 2. Cargill Ag Horizons
- 3. Perlco
- 3. Tennessee Consolidated Coal
- 4. Tennessee Consolidated Coal Company
- 5. Commercial Metal, Chattanooga Dock
- 6. Philip Services Corporation Mooring
- 7. American Electrical Inds., Inc.
- 8. Smoky Mountain Transfer Corportion
- 9. Philip Services Corporation Fertilizer Dock Page 50
CSXT NS NS NS NS NS CSXT CN BNSF KCS UP UP UP UP UP BNSF BNSF UP UP UP CN CN CSXT CSXT NS CSXT CSXT NS NS NS NS CSXT CSXT CSXT CSXT CSXT NS CN NS y
a w
r eta W
m o
T n
n e
T Tennessee River r
e vi R
e e
ss e
n n
e T
Cumberland River Tennessee River ss i
M ss i
r e
vi R
ip pi Ohio River T
T T
T T
T T
T T
T T
T T
T T
T Tennessee Waterway Assessment Study Hanson Professional Services Exhibit 4-4. Sand and Gravel Terminals Tennessee River Terminals Herbert Sangravl Co., New Johnsonville Docks Tinker Sand and Gravel, Inc.
Teague Brothers Sand and Gravel Signal Mountain Cement Co.,
Bennett Lake Quarry Dock Signal Mountain Cement Company Plant Vulcan Materials American Limestone Co.
Ricker Materials Tennessee CN Lauderdale Madison Allen Ballard Calloway Livingston Lyon McCracken Marshall Monroe Simpson Catoosa Murray Whitfield Alcorn Prentiss Tippah Tishomingo Union Craighead Crittenden Cross Mississippi Poinsett Bollinger Butler Dunklin Stoddard Alexander Hardin Johnson Massac Pope Pulaski to Columbus to Chicago Chattanooga Paducah Florence Jonesboro T
2 6
1 2
Mississippi River Terminals Martin Marietta Aggregates, Lake Cormorant Dock Arkansas Sand and Gravel Brown Sand and Gravel Taylor Sand and Gravel -
Affiliate of Wepfer Marine Taylor Sand and Gravel -
Affiliate of Wepfer Marine Lattus Sand & Gravel Co.
Illinois to St. Louis to Louisville Kentucky Missouri to Cincinnati Cape Union Girardeau Madison Crittenden Taylor Casey Edmonson Hart Hopkins Butler Green Caldwell Muhlenberg Adair Pulaski Warren Christian Wayne Scott to Springfield Metcalfe Logan Barren Russell Todd Mississippi Carlisle Cumberland Wayne McCreary Poplar Bluff Trigg Whitley Graves Clinton Hickman 1
5 New Madrid 6 Fulton Clay Pemiscot 3-4 Nashville Greene 2-3 1
Knoxville 3
Graham North 5
4 Cherokee Carolina Memphis St. Francis Fannin Dade Jackson to Little Rock Benton Union Lee Huntsville De Soto Limestone Walker Gilmer Tate Marshall Colbert Decatur Tunica Lumpkin Arkansas Chattooga Gordon Pickens Franklin Lawrence Morgan DeKalb Dawson Marshall Mississippi Georgia to Atlanta Alabama Cumberland River Terminals
- 1.
- 1.
- 1. Ingram Materials Company
- 2. Metro Materials
- 2.
- 2.
- 3. Ingram Materials Company
- 3.
- 3.
- 4.
- 4.
- 5.
- 5.
- 6.
- 6.
- 7.
- 8.
Page 51
CSXT NS NS NS NS NS CSXT CN BNSF KCS UP UP UP UP UP BNSF BNSF UP UP UP CN CN CSXT CSXT NS CSXT CSXT NS NS NS NS CSXT CSXT CSXT CSXT CSXT NS CN NS y
a w
r eta W
m o
T n
n e
T Tennessee River r
e vi R
e e
ss e
n n
e T
Cumberland River Tennessee River ss i
M ss i
r e
vi R
ip pi Ohio River T
T T
T T
T T
T T
T T
T T
T T
T Tennessee Waterway Assessment Study Hanson Professional Services Mississippi River Terminals Holman (US) Cement Terminal Martin Marietta Aggregates Memphis Cement APAC Tennessee, Memphis Terminal Dock LaFarge Corp. - Bulk Cement Transfer &
Buzzi Unichem (prev. Lone Star Industries) -
Memphis Terminal Dock River Ready Mix Exhibit 4-5. Cement Terminals Tennessee CN Lauderdale Madison Allen Ballard Calloway Livingston Lyon McCracken Marshall Monroe Simpson Catoosa Murray Whitfield Alcorn Prentiss Tippah Tishomingo Union Craighead Crittenden Cross Mississippi Poinsett Bollinger Butler Dunklin Stoddard Alexander Hardin Johnson Massac Pope Pulaski to Columbus to Chicago Chattanooga Paducah Florence Jonesboro T
5 4
3 Illinois to St. Louis to Louisville Kentucky Missouri to Cincinnati Cape Union Girardeau Madison Crittenden Taylor Casey Edmonson Hart Hopkins Butler Green Caldwell Muhlenberg Adair Pulaski Warren Christian Wayne Scott to Springfield Metcalfe Logan Barren Russell Todd Mississippi Carlisle Cumberland Wayne McCreary Poplar Bluff Trigg Whitley Graves Clinton Hickman New Madrid Fulton Clay Pemiscot Nashville 1-3 Greene 9
Knoxville Graham North 1
4-8 Cherokee Carolina Memphis St. Francis Fannin Dade Jackson to Little Rock Benton Union Lee Huntsville De Soto Limestone Walker Gilmer Tate Marshall Colbert Decatur Tunica Lumpkin Arkansas Chattooga Gordon Pickens Franklin Lawrence Morgan DeKalb Dawson Marshall Mississippi Georgia to Atlanta Alabama Tennessee River Terminals
- 1.
- 1. Cemex, Inc.
- 2. Buzzi Unicem
- 3. APAC Tennessee, West Memphis Dock
- 4.
- 5.
Cumberland River Terminals
- 6.
- 7.
- 1. Lafarge Storage
- 2. Lone Star Industries, Inc.
- 8.
- 3. Signal Mountain Cement Company
- 4. Southdown, Inc.
- 9.
- 5. Holnam, Inc.
Page 52
CSXT NS NS NS NS NS CSXT CN BNSF KCS UP UP UP UP UP BNSF BNSF UP UP UP CN CN CSXT CSXT NS CSXT CSXT NS NS NS NS CSXT CSXT CSXT CSXT CSXT NS CN NS Tenn-Tom Waterway T e n n e s s e e R i v e r Tennessee River C u m b e r l a n d R i v e r T e n n e s see R i v e r Mis sis sippi River O h i o R i v e r T
T T
T T
T T
T T
T T
T T
T T
T Tennessee Waterway Assessment Study Hanson Professional Services Tennessee CN Lauderdale Madison Allen Ballard Calloway Livingston Lyon McCracken Marshall Monroe Simpson Catoosa Murray Whitfield Alcorn Prentiss Tippah Tishomingo Craighead Crittenden Cross Mississippi Poinsett Bollinger Butler Dunklin Stoddard Alexander Hardin Johnson Massac Pope Pulaski to Columbus to Chicago Chattanooga Paducah Florence Jonesboro T
2-3 Mississippi River Terminals Helm Fertilizer Terminal, Memphis Dry Fertilizer Dock Blythville River and Rail Terminal - Bunge Corp., Barfield Terminal Dock Terra Industries, Blytheville Plant Dock West Tennessee Terminals AG Distributors, Caruthersville Dock MFA Caruthersville Dock River Bend Ag, New Madrid Liquid Fertilizer Dock Cargill AgHorizons, New Madrid Dry Fertilizer Dock Exhibit 4-6. Fertilizer Terminals Illinois to St. Louis to Louisville Kentucky Missouri to Cincinnati Cape Union Girardeau Madison Crittenden Taylor Casey Edmonson Hart Hopkins Butler Green Caldwell Muhlenberg Adair Pulaski Warren Christian Wayne Scott to Springfield Metcalfe Logan Barren Russell Todd Mississippi Carlisle Cumberland Wayne McCreary Poplar Bluff Trigg Whitley Graves Clinton Hickman 7-8 New Madrid Fulton Clay Pemiscot Nashville Greene 5-6 4
Knoxville Graham North Cherokee 1
Carolina Memphis St. Francis Fannin Dade Jackson to Little Rock Benton Union Lee Huntsville De Soto Limestone Walker Gilmer Tate Marshall Colbert Decatur Tunica Lumpkin Arkansas Chattooga Union Gordon Pickens Franklin Lawrence Morgan De Kalb Dawson Marshall Mississippi Georgia to Atlanta Alabama
- 1.
- 2.
- 3.
- 4.
- 5.
- 6.
- 7.
- 8.
Page 53
CSXT NS NS NS NS NS CSXT CN BNSF KCS UP UP UP UP UP BNSF BNSF UP UP UP CN CN CSXT CSXT NS CSXT CSXT NS NS NS NS CSXT CSXT CSXT CSXT CSXT NS CN NS y
a w
r eta W
m o
T n
n e
T Tennessee River r
e vi R
e e
ss e
n n
e T
Cumberland River Tennessee River ss i
M ss i
r e
vi R
ip pi Ohio River T
T T
T T
T T
T T
T T
T T
T T
T Tennessee Waterway Assessment Study Hanson Professional Services Exhibit 4-7. On Site Terminals Mississippi River Terminals
- 2. TVA TH Allen Electric Generation Plan
- 3. Nucor-Yamato Steel Corp.,
Blytheville Dock
- 4. Marine Terminals of Arkansas, Barfield Dock and Fleet Mooring
- 5. Marine Terminals of Arkansas, Hickman Docks
- 6. Nucor Steel, Blytheville Dock
- 7. Trinity Marine Products, Caruthersville Shipyard Dock
- 8. Noranda Aluminum, New
- 9. City of New Madrid Power Plant Tennessee River Terminals
- 1. Scepter, Inc.
- 2. El Dupont Denemours & Co.
- 3. TVA, Johnsonville Steam Plant,
- 4. Vulcan Materials Co. - Clifton
- 5. International Paper Company
- 6. Serodino, Inc. - Shipyard Pier
- 7. Alston ABB Combustion
- 8. TVA Sequoyah Nuclear Plant
- 9. Olin Corp. - Charleston Plant
- 10. Southern Ionics, Inc.
- 11. TVA Watts Bar Fossil Plant
- 12. TVA Bull Run Fossil Plant
- 13. TVA Kingston Fossil Plant
- 14. Tennessee Valley Port
- 15. McKinnon Bridge Co., Loudon
- 16. AE Stanley Manufacturing, Inc.
Tennessee CN Lauderdale Madison Allen Ballard Calloway Livingston Lyon McCracken Marshall Monroe Simpson Catoosa Murray Whitfield Alcorn Prentiss Tippah Tishomingo Union Craighead Crittenden Cross Mississippi Poinsett Bollinger Butler Dunklin Stoddard Alexander Hardin Johnson Massac Pope Pulaski to Columbus to Chicago Memphis Chattanooga Paducah Florence Jonesboro T
3 4
7-9 10 3-4 5-6 5
6 7
11 15 12-14 16 8
5 Illinois to St. Louis to Louisville Kentucky Missouri to Cincinnati Cape Union Girardeau Madison Crittenden Taylor Casey Edmonson Hart Hopkins Butler Green Caldwell Muhlenberg Adair Pulaski Warren Wayne Christian Scott to Springfield Metcalfe Logan Barren Russell Todd Mississippi Carlisle Cumberland Wayne McCreary Poplar Bluff Trigg Whitley Graves Clinton Hickman 1
8-9 New Madrid Fulton 1
2 Clay Pemiscot 6
Nashville Greene 1-3 7
Knoxville 4
9-10 Graham North Cherokee 1-2 Carolina St. Francis Fannin Dade Jackson to Little Rock Benton Union Lee Huntsville De Soto Limestone Walker Gilmer Tate Marshall Colbert Decatur Tunica Lumpkin Arkansas Chattooga Gordon Pickens Franklin Lawrence Morgan DeKalb Dawson Marshall Mississippi Georgia to Atlanta Alabama Cumberland River Terminals
- 1. Metal Prep
- 1. TVA Cumberland Fossil Plant
- 2. Zinifex - Clarksville, Inc.
- 3. Nashville Bridge Company Fuel Oil Dock
- 4. Philip Metals, Inc.
- 5. Mid-South Wire Company
- 6. EI DuPont Denemours &
Company, Inc.
- 7. Garrott Brothers, Inc.
Engineering, Inc.
- 8. TVA Gallatin Fossil Plant
- 9. TVA Gallatin Fossil Plant
- 10. TVA Hartsville Plant Site Authority, Watts Bar, Steam Plant Dock Madrid Dock Wharf Page 54
general purpose crane rigged with a clam shell bucket. Most power plants and other high volume users will have a dedicated special purpose dock with staging area for a number of barges, barge haul equipment and an unloading device like a bucket wheel or other high-speed machine to deliver the coal to an inbound conveyor.
Navigation/Marine Service Terminals - Navigation/marine services category includes facilities which are not necessarily terminals that handle cargo, but rather includes facilities whose core purpose is to provide services to the marine industry. These facilities are shown in Exhibit 4-8 and include fleeting and mooring service providers, government agencies such as the United States Coast Guard and Corps of Engineers, and fueling/grocery service for towboats.
Other Terminals - Other terminals are those that have a use that is not directly classified above.
Exhibit 4-9 displays the other terminals which are used for miscellaneous purposes. Of interest, is that the Cates Casting Field, listed on the Mississippi River in Northwest Tennessee, is the location of a new public port facility (Cates Landing Terminal) expected to open in late 2007/early 2008.
Inactive Terminals - Inactive terminals are those used that are not regularly operated. Exhibit 4-10 shows these terminals.
4.2.3.2 General Purpose Terminals Public port authorities often construct a general purpose river terminal to enhance the overall economic development competitiveness of an area by providing capability to load and/or unload a wide variety of materials and commodities. Some general purpose terminals are constructed, owned and operated by private companies to provide services to the general public. General purpose terminals are shown in Exhibit 4-11, including those in adjoining states which serve markets in Tennessee.
Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page 55
CSXT NS NS NS NS NS CSXT CN BNSF KCS UP UP UP UP UP BNSF BNSF UP UP UP CN CN CSXT CSXT NS CSXT CSXT NS NS NS NS CSXT CSXT CSXT CSXT CSXT NS CN NS y
a w
r eta W
m o
T n
n e
T Tennessee River r
e vi R
e e
ss e
n n
e T
Cumberland River Tennessee River ss i
M ss i
r e
vi R
ip pi Ohio River T
T T
T T
T T
T T
T T
T T
T T
T Tennessee Waterway Assessment Study Hanson Professional Services Exhibit 4-8. Navigation/Marine Service Terminals Tennessee CN Lauderdale Madison Allen Ballard Calloway Livingston Lyon McCracken Marshall Monroe Simpson Catoosa Murray Whitfield Alcorn Prentiss Tippah Tishomingo Union Craighead Crittenden Cross Mississippi Poinsett Bollinger Butler Dunklin Stoddard Alexander Hardin Johnson Massac Pope Pulaski to Columbus to Chicago Chattanooga Paducah Florence Jonesboro T
2 5 6-7 1-6 11 3
- 1. Barnhart Crane & Rigging Co.
- 2. Great Lakes Dredging
- 4. Pine Bluff Sand and Gravel
- 7. Patton Tully Trans. Co. Mooring
- 8. Waxler Towing Co. (Economy
- 9. American Commercial Terminals, Memphis Dock
- 10. Vulcan Material (Barge Fleeting)
- 11. Poinsett Rice & Grain
- 12. West Tennessee Terminals
- 13. Tri-State Marine Service, Dock
- 14. Caruthersville Marine Service,
- 15. St. Jude and New Madrid Harbor
- 16. St. Jude and New Madrid Harbor
- 17. Wepfer Marine, Hickman Dock
- 18. Hickman Harbor Service Mississippi River Terminals Illinois to St. Louis to Louisville Kentucky Missouri to Cincinnati Cape Union Girardeau Madison Crittenden Taylor Casey Edmonson Hart Hopkins Butler Green Caldwell Muhlenberg Adair Pulaski Warren Wayne Christian Scott to Springfield Metcalfe Logan Barren Russell Todd Mississippi Carlisle Cumberland Wayne McCreary Poplar Bluff Trigg Whitley Graves Clinton Hickman 15-16 Fulton New Madrid 17-19 1
Clay Pemiscot 1 3 Nashville 4 Greene 2
13-14 Knoxville 12 Graham North 4
5 Cherokee 7-10 Carolina Memphis St. Francis Fannin Dade Jackson to Little Rock Benton Union Lee Huntsville De Soto Limestone Walker Gilmer Tate Marshall Colbert Decatur Tunica Lumpkin Arkansas Chattooga Gordon Pickens Franklin Lawrence Morgan DeKalb Dawson Marshall Mississippi Georgia to Atlanta Alabama Tennessee River Terminals
- 1. US Coast Guard Pier
- 2. New Johnsonville Marine and Fleet Mooring Service
- 3. Wepfer Marine
- 3. Serodino, Inc. - Shipyard Pier Dock and Fleet Mooring
- 4. Southern Electric Fleeting Co.,
- 5. Wepfer Marine Chattanooga Mooring US Coast Guard Pier
- 6. Wepfer Marine Service, Lower Fleet Moorings
- 5.
Service, New Madrid Fleet Moorings Boat Store Cumberland River Terminals
- 1. Ingram Materials Co. - Fleeting and Fleet Mooring
- 2. Cherokee Marine Terminal -
- 19. U.S. Coast Guard, Depot Hickman Moorings Fleeting
- 3. Ingram Materials Co. - Fleeting
- 4. Ingram Materials Co. - Fleeting
- 5. Nashville Bridge Co.
- 6. Ingram Materials Co. - Fleeting
- 7. US Army Corps of Engineers Page 56
CSXT NS NS NS NS NS CSXT CN BNSF KCS UP UP UP UP UP BNSF BNSF UP UP UP CN CN CSXT CSXT NS CSXT CSXT NS NS NS NS CSXT CSXT CSXT CSXT CSXT NS CN NS y
a w
r eta W
m o
T n
n e
T Tennessee River r
e vi R
e e
ss e
n n
e T
Cumberland River Tennessee River ss i
M ss i
r e
vi R
ip pi Ohio River T
T T
T T
T T
T T
T T
T T
T T
T Tennessee Waterway Assessment Study Hanson Professional Services Exhibit 4-9. Other Terminals Mississippi River Terminals
- 1. Rivergate Industrial Port
- 2. T&B Trucking
- 3. Barnhart Crane and Rigging
- 4. USACE Ensley Engineer Yard Wharf
- 5. Truman Arnold Companies/West Memphis Dock
- 6. Luhr Brothers
- 7. Patton-Tully Transportation Co.
- 8. USCG Lower Mississippi River
- 9. US Army Corps of Engineers, Richardson Casting Field Landing
- 10. McAlister Construction Co.
- 11. James Marine Equipment
- 12. Caruthersville Casting Field
- 13. Ralph Anderson Lumber co.
- 14. Cates Casting Field Tennessee CN Lauderdale Madison Allen Ballard Calloway Livingston Lyon McCracken Marshall Monroe Simpson Catoosa Murray Whitfield Alcorn Prentiss Tippah Tishomingo Union Craighead Crittenden Cross Mississippi Poinsett Bollinger Butler Dunklin Stoddard Alexander Hardin Johnson Massac Pope Pulaski to Columbus to Chicago Chattanooga Paducah Florence Jonesboro T
6-8 5
9-10 Illinois to St. Louis to Louisville Kentucky Missouri to Cincinnati Cape Union Girardeau Madison Crittenden Taylor Casey Edmonson Hart Hopkins Butler Green Caldwell Muhlenberg Adair Pulaski Warren Wayne Christian Scott to Springfield Metcalfe Logan Barren Russell Todd Mississippi Carlisle Cumberland Wayne McCreary Poplar Bluff Trigg Whitley 13 Hickman Graves Clinton New Madrid Fulton 14 Clay Pemiscot Nashville Greene 11-12 Knoxville Graham North Cherokee Carolina 1-4 Memphis St. Francis Fannin Dade Jackson to Little Rock Benton Union Lee Huntsville De Soto Limestone Walker Gilmer Tate Marshall Colbert Decatur Tunica Lumpkin Arkansas Chattooga Gordon Pickens Franklin Lawrence Morgan DeKalb Dawson Marshall Mississippi Georgia to Atlanta Alabama Page 57
CSXT NS NS NS NS NS CSXT CN BNSF KCS UP UP UP UP UP BNSF BNSF UP UP UP CN CN CSXT CSXT NS CSXT CSXT NS NS NS NS CSXT CSXT CSXT CSXT CSXT NS CN NS y
a w
r eta W
m o
T n
n e
T Tennessee River r
e vi R
e e
ss e
n n
e T
Cumberland River Tennessee River ss i
M ss i
r e
vi R
ip pi Ohio River T
T T
T T
T T
T T
T T
T T
T T
T Tennessee Waterway Assessment Study Hanson Professional Services Exhibit 4-10. Inactive Terminals Mississippi River Terminals Cargill AgHorizons, Richardson Continental Grain Co., Golddust Fred Stokes Oil Co.
Triple L. Marine Service,
- 1.
- 2. Hardin County Port -
- 3. TVA Raccoon Mountain
- 4. Luria Brothers & Co.
- 5. BP - Amoco Oil Company
- 7. Concrete Service Company
- 8. Vulcan Materials Co.,
- 9. Volunteer Army Ammunition
- 10. Bowater, Calhoun Woodlands
- 11. Bowater, Southern Division -
- 12. Bowater, Calhoun Woodlands Cumberland River Terminals Shell Oil Company, Inc.
Lion Oil Company Cities Serv. Oil Co.
Triangle Refineries Gainsboro Port Authority Celina Port Authority Tennessee CN Lauderdale Madison Allen Ballard Calloway Livingston Lyon McCracken Marshall Monroe Simpson Catoosa Murray Whitfield Alcorn Prentiss Tippah Tishomingo Union Craighead Crittenden Cross Mississippi Poinsett Bollinger Butler Dunklin Stoddard Alexander Hardin Johnson Massac Pope Pulaski to Columbus to Chicago Chattanooga Paducah Florence Jonesboro T
8 4-5 7
8 2
3 4-8 9
10 12 13-17 18 19 20 Illinois to St. Louis to Louisville Kentucky Missouri to Cincinnati Cape Union Girardeau Madison Crittenden Taylor Casey Edmonson Hart Hopkins Butler Green Caldwell Muhlenberg Adair Pulaski Warren Wayne Christian Scott to Springfield Metcalfe Logan Barren Russell Todd Mississippi Carlisle Cumberland Wayne McCreary Poplar Bluff Trigg Whitley Graves Clinton Hickman New Madrid 3-4Fulton Clay Pemiscot 1-2 Nashville 24-25 Greene 3 6 21 1
22-23 Knoxville 2
1 11 Graham North Cherokee Carolina Memphis St. Francis Fannin Dade Jackson to Little Rock Benton Union Lee Huntsville De Soto Limestone Walker Gilmer Tate Marshall Colbert Decatur Tunica Lumpkin Arkansas Chattooga Gordon Pickens Franklin Lawrence Morgan DeKalb Dawson Marshall Mississippi Georgia to Atlanta Alabama Tennessee River Terminals
- 1.
- 2.
Vanguard Services, Inc., Div.
- 13. Bowater, Calhoun Woodlands of Al Johnson Construction Co.
Operations Landing Dock
- 14. Clinch River Corporation Packaging Corp. of America
- 15. Eagles Bend Manf. Co.
Elevator Dock
- 3.
- 16. Harbert International, Inc. -
- 4.
Pumped Storage Plant Harriman Coal
- 17. US Dept. of Energy Hickman Dock
- 18. APAC of Tennessee, Harrison
- 6. Rock-Tenn Company - Mill Div.
Division
- 19. Tellico Reservoir Dev. Agency
- 20. TVA Singleton Dock
- 21. Signal Mountain Cement Co.
- 1.
Chattanooga Batch Plant Dock
- 22. Star Enterprise Co.
- 2. Exxon Co.
- 23. RL Conley and Company
- 3.
Plant
- 24. White Lily Foods (not owned
- 4.
by them anymore)
- 5. NAMOLCO Operations
- 25. Regal Corp., Knoxville
- 6.
Terminal Wharf
- 7.
Fuel Oil
- 8.
Operations Page 58
CSXT NS NS NS NS NS CSXT CN BNSF KCS UP UP UP UP UP BNSF BNSF UP UP UP CN CN CSXT CSXT NS CSXT CSXT NS NS NS NS CSXT CSXT CSXT CSXT CSXT NS CN NS y
a w
r eta W
m o
T n
n e
T Tennessee River r
e vi R
e e
ss e
n n
e T
Cumberland River Tennessee River ss i
M ss i
r e
vi R
ip pi Ohio River T
T T
T T
T T
T T
T T
T T
T T
T Tennessee Waterway Assessment Study Hanson Professional Services Mississippi River Terminals Kinder Morgan Bulk Terminals Lash Intermodal Terminal Kinder Morgan Bulk Terminals Fullen Dock and Warehouse, Memphis Wharves West Tennessee Terminals Pemiscot County Port Authority St. Jude Industrial Park, Barge Hickman-Fulton County Riverport Authority Exhibit 4-11. General Purpose Terminals Tennessee River Terminals
- 1.
- 2.
- 3.
- 4.
- 5.
- 6.
- 7.
- 8.
Tennessee CN Lauderdale Madison Allen Ballard Calloway Livingston Lyon McCracken Marshall Monroe Simpson Catoosa Murray Whitfield Alcorn Prentiss Tippah Union Craighead Crittenden Cross Mississippi Poinsett Bollinger Butler Dunklin Stoddard Alexander Hardin Johnson Massac Pope Pulaski to Columbus to Chicago Chattanooga Paducah Florence Jonesboro T
3 4
1-2 3
4-5 6
7 Illinois to St. Louis to Louisville Kentucky Missouri to Cincinnati Cape Union Girardeau Madison Crittenden Taylor Casey Edmonson Hart Hopkins Butler Green Caldwell Muhlenberg Adair Pulaski Warren Wayne Christian Scott to Springfield Metcalfe Logan Barren Russell Todd Mississippi Carlisle Cumberland Wayne McCreary Poplar Bluff Trigg Whitley Graves Clinton Hickman 1
7 Fulton New Madrid 8
Clay Pemiscot 8
2 Nashville Greene 1
5 Knoxville Graham North Cherokee 4
Carolina 3
Memphis St. Francis Fannin Dade Tishomingo 2
Jackson to Little Rock Benton Union Lee Huntsville De Soto Limestone Walker Gilmer Tate Marshall Colbert Decatur Tunica Lumpkin Arkansas Chattooga Gordon Pickens Franklin Lawrence Morgan DeKalb Dawson Marshall Mississippi Georgia to Atlanta Alabama Cumberland River Terminals
- 1.
Herbert Sangravl Co., New
- 1. Winn Materials
- 2.
Johnsonville Docks
- 2. Hunter Marine Transport, Inc.
Company Yellow Creek State Inland Port
- 3. Haileys Harbor River
- 3.
Authority Transportation Terminal
- 4.
Port of Nickajack, Inc.
- 4. Cherokee Marine Terminals Mid South Terminals, Div. of
- 5.
Serodino, Inc.
- 6.
JIT Terminals
- 7.
Centre South Riverport Dock Fort Loudon Terminal
- 8.
Burkhart Enterprises, Inc.
Page 59
A general purpose terminal provides access to barge transportation for shippers who need to take advantage of low-cost barge rates, but do not have sufficient annual tonnage to justify construction of their own facility. In Tennessee, there are 15 general purpose terminals as shown in the table below. Four are located on the Mississippi River, another four terminals on the Cumberland River and seven on the Tennessee River. Recent news has also indicated that preliminary work on the Port of Cates Landing in Tiptonville, TN, is scheduled to begin around April of 2007.
There are four publicly owned general cargo terminals in Tennessee. The four publicly owned terminals are leased to and operated by private sector entities. The Memphis County Port Commission owns two terminals in Memphis operated by Kinder Morgan and Lash Intermodal.
The Nickajack Port Authority owns the Port of Nickajack in South Pittsburg, TN and is operated by Parker Towing. The Hamilton County Port Authority owns the Centre South Riverport Wharf in Chattanooga which is also operated by Parker Towing. All others are privately owned and there are no publicly operated terminals in Tennessee.
General Cargo Terminals in the Study Area River Mile L/R Terminal Location Public Ownership Private Ownership Public Operation Private Operation Mississippi 725.0 L
Kinder Morgan Bulk Terminals Memphis, TN X
X Mississippi 725.0 L
Lash Intermodal Terminal Company Memphis, TN X
X Mississippi 740.3 L
Fullen Dock and Warehouse, Memphis Wharfs.
Memphis, TN X
X Mississippi 818.5 L
West Tennessee Terminals Halls, TN X
X Cumberland 123.9 R
Winn Materials Clarksville, TN X
X Cumberland 175.5 L
Hunter Marine Transport, Inc.
Nashville, TN X
X Cumberland 180.1 R
Hailey's Harbor River Transportation Terminal Nashville, TN X
X Cumberland 189.9 R
Cherokee Marine Terminals Nashville, TN X
X Tennessee 100.4 R
Herbert Sangravl Co., New Johnsonville Docks.
New Johnsonville, TN X
X Tennessee 423.7 L
Port of Nickajack, Inc.
South Pittsburg, TN X
X Tennessee 456.2 R
Mid South Terminals, Div of Serodino, Inc.
Chattanooga, TN X
X Tennessee 463.8 R
JIT Terminals Chattanooga, TN X
X Tennessee 466.5 L
Centre South Riverport Chattanooga, TN X
X Tennessee 600.2 R
Fort Loudon Terminal Lenoir City, TN X
X Tennessee 652.2 R
Burkhart Enterprises, Inc Knoxville, TN X
X Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page 60
Kinder Morgan Bulk Terminals on Presidents Island in the Port of Memphis is located at RM 725.0 on the Lower Mississippi River.
The terminal includes two docks, has 168,000 sq. ft. of warehouse capacity and handles dry bulk, break-bulk, liquids and special cargo.
The terminal offers access to interstate highways within one mile proximity and an on-site rail connection to the Union Pacific (UP), Canadian National (CN), Burlington Northern (BN), CSX Transportation (CSX) and Norfolk Sourthern (NS).
Lash Intermodal Terminal Company is located at RM 725.0 on the Lower Mississippi River, also on the Presidents Island portion of the Port of Memphis. The terminal includes one dock, has 287,000 sq. ft. of warehouse space and handles general cargo.
The terminal offers access to highways within one mile proximity and an on-site rail connection to the UP, CN, BN, CSX and NS. The interesting feature that Lash Intermodal provides is handling LASH (acronym for lighter aboard ship) barges which are landed on pedestals inside a warehouse for loading and unloading. LASH barges have dimensions of 61.5 x 31.0.
Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page 61
Fullen Dock and Warehouse is located at RM 740.3 on the Lower Mississippi River.
This privately-owned terminal includes six docks, over 500,000 sq. ft. of covered storage, 750,000 sq. ft.
of paved storage, and handles containers, steel, aggregates and general cargo. It also has highway access (Hwy 78) to Interstates 40 and 55 as well as rail access to the CSX, BN, UP and NS.
West Tennessee Terminals is located at RM 818.5 on the Lower Mississippi River.
The terminal includes a floating dock and handles dry-bulk, fertilizer, aluminum, steel, scrap and grain.
The terminal is in close proximity to Hwy 88 and does not have a rail connection.
Winn Materials is located at RM 123.9 on the Cumberland River. The terminal includes a sheet pile dock structure and handles primarily limestone products and sand. I-24 is within 7 miles of the facility. There is no rail connection.
Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page 62
Hunter Marine Transport is located at RM 175.5 on the Cumberland River. This private, general purpose terminal includes two docks, 100,000 sq. ft.
of covered storage and handles steel, dry bulk, coke, sand, salt, stone coal, fertilizer and general cargo.
I-40 is less than three miles south; Hwy. 155 is less than 2 miles east of the terminal and the terminal offers a connection to the CSX.
Haileys Harbor is located at RM 180.1 on the Cumberland River. The terminal includes one dock, a small slack water harbor and handles steel, scrap, coal, salt, dry bulk and general commodities.
Hwy. 155, or Briley Parkway, is less than one mile away and provides connection to interstates within 10 miles. Nashville and Western provides rail service.
Cherokee Marine Terminals is located at RM 189.9 on the Cumberland River. The terminal includes three docks, 160,000 sq. ft. of warehouse space and handles steel, heavy lift cargo and general cargo. I-24 is adjacent to the facility and CSX is on-site.
Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page 63
Herbert Sangravl Co., New Johnsonville Docks is located at RM 100.4 of the Tennessee River. The terminal includes a sheet pile dock structure and offers paved storage and primarily handles aggregates, steel, coke, livilite, coal, ore, sand and aluminum. I-40 access is less than 10 miles away; US-70 is 5 miles away and CSX is on-site.
The Port of Nickajack is located at RM 423.7 of the Tennessee River. The terminal includes one dock, ground storage and handles pig iron, forest products, aggregates and coal. State Highway 156 is adjacent and rail service is not available on-site.
Mid-South Terminals is located at RM 456.2 on the Tennessee River. The terminal operates using mooring dolphins and cells. Typical commodities handled are iron, steel, coal, coke, grain and aggregates.
Rail is on-site and US-27 provides access to I-24.
Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page 64
JIT Terminals is located at RM 463.8 on the Tennessee River.
The terminal operates via mooring structures along the waterway and utilizes a 155,000 sq. ft. building. Steel, chemicals and propane are the primary commodities handled. Rail is on-site and Highway 27 connects with I-24 in the near vicinity.
Centre South Riverport is located at RM 466.5 on the Tennessee River. Part of a 300 acre multi-modal industrial park, the terminal operates using a sheet pile dock, mooring structures and open storage. Typical commodities handled are steel, dry bulk and break-bulk. Hwy 58 and I-24 are nearby.
NS rail service is on-site.
Fort Loudon Terminal is located at RM 600.2 on the Tennessee River. The terminal handles general cargo and operates two storage buildings totaling 75,000 sq. ft. Rail service is on-site and both I-40 and I-75 are within three miles of the site.
Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page 65
Burkhart Enterprises is located at RM 652.2 on the Tennessee River. The terminal has two docks and over 24,000 sq. ft. of warehouse storage. Highway 168 connects the port to I-40 and I-70 and rail is on-site.
Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page 66
5.0 PUBLIC AND STAKEHOLDER OUTREACH In order to provide the State of Tennessee with short and long-range plans of action so that the rivers of Tennessee maintain their recognition as part of the national transportation system, it is useful to have an understanding of the roles of stakeholders and what other neighboring states are doing to increase the use of water transportation and improve regional and national economic conditions.
5.1 Identification of Stakeholder Groups Three general stakeholder groups that have an inherent interest in the promotion of waterborne commerce were identified. Interaction with these groups will be recommended for Phase II of this study.
General Purpose Terminals - General purpose terminals generate significant local and regional economic growth, including job creation. They serve existing business users, may provide services to attract new industry and create and expand opportunities for port services.
Shippers and Carriers - This stakeholder group includes major shippers with potential to use waterborne transportation. These shippers own and move the cargo. For example, shippers may include owners of steel, cement and chemical companies. Carriers include the barge lines. They play an integral role in providing valuable input on future transportation needs.
Government - This group includes local, state, and federal government agencies as well as development districts, economic development entities, and metropolitan planning organizations (MPOs) located along Tennessees waterways. This group has an intrinsic stake in the impact of waterborne commerce on bringing jobs and additional tax base into their area.
Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page 67
5.2 Programs in Neighboring States A survey of state-level programs was conducted to determine what programs and assistance is provided by those states to support ports and waterways. The following is a description of several state programs that have been proactive in formulating action plans and legislative initiatives to provide such support as well as a description of Tennessees current program. Each state surveyed was unique in their approach to support ports and waterways. A summary of this information is provided on page 72.
Alabama The Alabama State Legislature created a state-owned deepwater port in Mobile as early as 1923.
A subsequent law passed in 1953 led to as many as 14 inland ports that were authorized and built by the state. Four of these facilities were later transferred to local port authorities. For the others, the state leases the ports facilities to a company or companies for actual operation. Some of the inland ports have not been that successful because their locations were dictated more by political influence at that time than by market needs or economic justification.
In 2000, an Alabama State Port Authority was created replacing the existing Alabama State Docks Department that had jurisdiction over the deepwater port facilities in Mobile and the State-owned inland docks. The Authority is governed by a board of directors, consisting of eight appointed members by the Governor to staggered terms. The executive director serves at the pleasure of the Authority and not to the sitting governor. The port authority is also independent of the States Transportation Department (ALDOT).
ALDOT currently has no vested authorities or functions for water transportation. However, legislation has been introduced during the 2007 session of the Legislature to authorize water transportation as a modal function of ALDOT; establish a grant program to assist public ports with its capital needs; and, to create a ports and waterways advisory board, comprised of waterway interests, to advise policy makers within DOT and state government on matters of Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page 68
importance to this mode. These legislative initiatives have broad political support and are expected to be enacted.
Kentucky The General Assembly passed legislation in 1964 to permit local governments to establish riverport authorities. Currently, there are eleven public riverport authorities of which seven have port operations while the other four are in the developmental stages. The seven older ports benefited from a grant and loan program that was enacted in 1966 and administered by the Kentucky Port and River Development Commission that was part of the Cabinet for Economic Development. The Commission was abolished in 1992 by the General Assembly and the state funding was discontinued. In 1998, state oversight for riverports was transferred to the Transportation Cabinet and is currently assigned to its Planning Division.
The Transportation Cabinet has commissioned a study of the states riverports and to formulate recommendations for a statewide riverport improvement program; a marketing strategy or plan for the ports; and development of a state program that will address the governance, marketing and funding needs of the Kentucky ports. This study is a form of technical assistance by the state and is scheduled for completion in the summer of 2007 in time to draft bills for consideration by the 2008 session of the General Assembly.
Louisiana Louisiana has more miles of navigable waterways than any of the other continental states. It is served by 6 deepwater ports, 8 coastal ports, 13 inland riverports, and 11 developing ports for a total of 38 public port authorities.
The state provides $20 million annually to its ports for funding and financing needed improvements. The grant program, called the Ports Priority Program, was started in 1989 and requires a 10 percent local match. Funding for the program comes from fees and taxes paid by the maritime related transportation industry but with the majority ($15 million) coming from the Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page 69
Transportation Trust Fund (gas tax revenues). The state had to pass a constitutional amendment to permit such use of road tax revenues. Many state constitutions only allow gas taxes to be spent on highway and bridge projects.
To establish the relative priorities of the grant applications, a benefit-to-cost analysis is conducted that compares the projects total investment costs to the economic benefits accruing to the state from that investment, such as the reduction in cargo handling and shipping costs, jobs created, increases in personal income, and other direct and indirect economic impacts. Priorities are also influenced by technical feasibility of the proposed improvement, its environmental impacts and the quality of the ports management. The applications are reviewed, evaluated, and prioritized within the Department of Transportation and Development.
The state has authorized a Waterways Infrastructure Bank that would provide financing and capital for port development activities needed to retain and increase commerce on Louisianas waterway. The bank has yet to be funded. A program to help ports market their facilities is also authorized but not yet funded.
The state port association has commissioned a study that has identified a need for 104 projects to be constructed during the next five years with a combined cost of nearly $850 million. The ports group advocates an increase in state funding to $40 million annually to help meet these needs.
Minnesota Minnesota is served by two waterway systems, the Mississippi River and the Great Lakes/St.
Lawrence Seaway. It has five ports on the Mississippi River that shipped nearly 12 million tons in 2005. The four ports on Lake Superior recorded a total of nearly 66 million tons of commerce that year, over one-half of which were associated with Minnesotas taconite industry.
The Ports and Waterways Section of the Minnesota Department of Transportation administers a Port Development Assistance Program. This revolving loan program began in 1996 and has Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page 70
received a total of $14.5 million in appropriations along with the revenues generated from repayment of loans. The maximum state match is 80 percent and is intended to modernize the physical infrastructure of its nine ports. Most of the funding is allocated to facility repair.
The MNDOT has gained a national reputation during the past 25 years for its research and studies concerning water transportation. Two such studies conducted were (1) Monetary Cost of a Modal Shift - 1997, which compares the fuel cost efficiency of the water mode to land modes and the air emission results of burning additional fuel to move the same product tonnage; and (2)
Environmental Impacts of a Modal Shift - 1991, which examined the type and extent of environmental impacts associated with the shift of the cargo from the water to either the rail or highway modes. This work has not only helped develop and maintain a comprehensive water transportation plan for the state, but some conclusions of its studies and research, such as that concerning user fees, environmental impacts and cost of modal shifts, have been of much importance to the waterway industry and to transportation policy makers.
Mississippi Mississippi has 16 public ports, two of which are state-owned and operated. Its Ports and Waterways Division is part of the Office of Intermodal Planning within the states transportation department. In 2000, MDOT completed a comprehensive study of the states ports, including an assessment of each ports infrastructure needs to accommodate current as well as anticipated commerce. This study provided timely information that led to enactment of a grant program by the Legislature to help finance these needs.
The Multi-Modal Transportation Improvement Fund apportions a set percentage of the annual appropriations to each of five modes. The percentage designated for ports is 38 percent. The legislature appropriated $10 million to the fund in 2007 from state fuel taxes resulting in $3.8 million for port improvements. A Port Multi-Modal Fund Committee reviews applications and makes recommendations to the MDOT for approval. Seven of the ten members of the committee are port directors. The grant is most unique since it does not require any matching funds from the Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page 71
port. Higher priority is given to those applications that plan to use the state grant funds to help leverage other financing for the ports proposed improvement. The grant funds cannot be spent for administrative or operational expenses.
The states economic development agency also administers a marketing assistance program available to the public ports. The state will contribute 50 percent of the costs for advertising, preparation of brochures, websites, and other marketing projects. Since enactment of the program, new investment near ports includes steel, automotive, ethanol, chemicals and other industries which use waterborne transportation.
Missouri Unlike most states, Missouri funds two grant programs for its 14 public port authorities. These ports handle about 2.4 million tons of commerce annually at an estimated worth of $4.1 billion.
One of the grant programs provides about $450,000 annually to assist the ports with administrative expenses, such as marketing and strategic planning. The grant was initially funded from general revenues, but more recently from sales taxes collected on vehicles. The program does not require a match.
Its other grant program is called the Port Capital Improvement Program. It assists ports with capital improvements and requires a 20 percent match from the local port authority. The program is funded at about $1 million annually that is appropriated from the State Transportation Fund. In addition, the state provides two public ferryboat operations on the Mississippi River and a grant of $75,000 to each ferry service every year to support those operations. The Multimodal Operations Division of the Missouri Department of Transportation administers the three grant programs.
Tennessee In 1987, the Waterways and Rail Division was established within TDOT. Tennessee currently has no grant or loan programs to assist ports. TDOT uses less than $100,000 of fuel taxes to Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page 72
fund port feasibility studies, waterway-related investigations and annual contributions to the Tenn-Tom Waterway Development Authority.
West Virginia The West Virginia Public Port Authority is part of the states Department of Transportation. It is governed by an 11-member board and has many responsibilities resembling an economic development agency. The Authoritys Board of Directors is comprised of the Transportation Secretary and 10 individuals divided between congressional districts who are appointed by the governor. The Authoritys role is multi-modal. Its charter defines a port or public port to include river ports, airports, rail, wayports, terminals, and other similar facilities for rail, water, highway, or air transportation. The Board hires and retains an Executive Director to run its day-to-day business.
While it has the power to acquire, lease, construct, own, and maintain ports, the Authority does not presently control or operate any such facilities. Its empowerments are far reaching, including the right of eminent domain and the issuance of public port revenue bonds to finance port projects. It has also cooperated with federal agencies, universities, and others to conduct studies and research to help promote water transportation in its state. Local port districts are chartered under the control of the Authority.
A notable achievement by the Authority was establishing a statistical port that encompasses 199 miles of the Ohio, Kanawha, and Big Sandy Rivers and comprised of river terminals within three states. The so-called Port of Huntington-Tristate Port ships nearly 80 million tons of commerce each year, making it the 7th largest water port in the United States.
Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page 73
Summary of State-Level Programs State Governance State Assistance to Ports Alabama Independent state port authority with pending DOT connection 2007 legislation pending to establish grant program to assist public ports with capital needs and create ports and waterway advisory board Kentucky KYDOT planning division Study of states riverports in progress with outcome anticipated to generate state-level program to assist ports Louisiana Intermodal Division of Dept.
of Transportation and Development
$20m annually from gas tax revenues in state funding and financing for needed improvements Minnesota MNDOT Revolving loan program established which has received $14.5m in appropriations along with revenues generated from loan repayments since 1996.
Maximum state match of 80% intended to modernize physical port infrastructure.
Mississippi MDOT Intermodal planning office &
marketing under economic development State appropriations of $3.8m for ports from fuel taxes.
States economic development agency administers marketing assistance whereby state contributes 50% of costs for advertising, brochures, websites, and other marketing projects.
Missouri MODOT 2 grant programs: (1) $450,000 annually from vehicles sales tax to assist ports with administration expenses such as marketing and strategic planning; (2) $1m annually from State Transportation Fund to assist ports with capital improvements Tennessee TDOT Less than $100k from fuel tax to fund port feasibility studies, waterway-related investigations and annual dues to the Tenn-Tom Waterway Development Authority.
West Virginia Public Port Authority under WVDOT Issuance of public port revenue bonds to finance port projects.
Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page 74
6.0
SUMMARY
AND CONCLUSIONS Tennessees growing population and economy has placed heavy demands on the states transportation system. Intensifying roadway congestion and increasing transportation-related pollution are by-products of a growing economy. Transportation planning with emphasis on freight mobility will be critical to addressing these issues. Many states have already recognized the importance of the inland waterway system and have programs to champion the development of ports and waterways. Other states are conducting extensive studies in order to implement their own state level programs. Whether currently in place or in the development process, what these states have in common is the recognition that port and waterway development will benefit their economy through attraction of new industries, high paying jobs, and enhancement of the tax base resulting from these new industries, strengthening their current economic position.
With its central location and extensive navigable river system, Tennessee is in a position to take a leadership role in facilitating waterborne commerce. DOT agencies have the role of facilitating a more efficient transportation system that enables economic growth and development.
Waterborne commerce can alleviate some of the ever increasing congestion issues the transportation infrastructure is facing, as well as enhance the economic development potential of the state.
Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page 75
Appendix Inventory of General Purpose River Terminals in Tennessee
General Purpose River Terminals in Tennessee
- River Mile L/R Name of Terminal General Location Page #
Mississippi 725.0 L
Kinder Morgan Terminals Memphis, TN A-2 Mississippi 725.0 L
Lash Intermodal Terminal Company (LITCO)
Memphis, TN A-4 Mississippi 740.3 L
Fullen Dock and Warehouse, Memphis Wharves Memphis, TN A-6 Mississippi 818.5 L
West Tennessee Terminals, LLC Halls, TN A-8 Cumberland 123.9 R
Winn Materials Clarksville, TN A-10 Cumberland 175.5 L
Hunter Marine Transport, Inc.
Nashville, TN A-12 Cumberland 180.1 R
Haileys Harbor River Transportation Terminal Nashville, TN A-14 Cumberland 189.9 R
Cherokee Marine Terminals Nashville, TN A-16 Tennessee 100.4 R
Herbert Sangravl Co., New Johnsonville Docks New Johnsonville, TN A-18 Tennessee 423.7 L
Port of Nickajack, Inc.
South Pittsburg, TN A-20 Tennessee 456.2 R
Mid South Terminals, Div. of Serodino, Inc.
Chattanooga, TN A-22 Tennessee 463.8 R
JIT Terminals Chattanooga, TN A-24 Tennessee 466.5 L
Centre South Riverport Chattanooga, TN A-26 Tennessee 600.2 R
Fort Loudon Terminal Lenoir City, TN A-28 Tennessee 652.2 R
Burkhart Enterprises, Inc.
Knoxville, TN A-30
- This appendix includes only those General Purpose River Terminals that are located within the State of Tennessee.
Appendix to Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page A-1
Port Name Kinder Morgan Terminals Location City Memphis County State Tennessee River Mississippi River River Mile 725.0 Dist. To Hwy.
I-55 < 1 mile Dist. To Rail Onsite, CN, UP, BN, CSX, NS Site Acres Developed 35 Acres Owned 35 Topography Flat Facilities Docks 2 docks, 5 barge capacity Buildings 168,000 sq. ft. capacity Equipment (6) Flat Railcars; (1) Truck Scale; (2) Locomotives; (4) Boom Cranes; (5) Overhead Cranes; Front End Loaders; Bobcat Services Offered Truck/Barge/Rail Business Wire rod, tin plates, steel, caustic soda, zinc, various grains and fertilizers, ferro alloys and furaldehyde Contact Terminal Owner The Memphis and Shelby County Port Commission Terminal Operator Kinder Morgan Appendix to Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page A-2
KINDER MORGAN BULK TERMINALS Illinois Missouri Arkansas Alabama Mississippi Georgia North Carolina Kentucky Tennessee Colbert De Kalb Jackson Lauderdale Lawrence Limestone Madison Marshall Morgan Franklin Ballard Catoosa Dade Dawson Fannin Pickens Whitfield Alcorn Benton Marshall Tate Tishomingo Lee Adair Pulaski Simpson Allen Monroe Barren Cumberland Russell Wa y n e Butler Caldwell Calloway Carlisle Marshall Todd Casey Wayne Paducah Christian Clinton Crittenden Taylor Edmonson Fulton Graves Green Hart Hickman Hopkins Livingston Logan Lyon McCracken McCreary Metcalfe Muhlenberg Trigg Wa rre n Whitley Chattooga Lumpkin Wa lke r Gilmer Gordon Murray Union Cherokee Graham De Soto Prentiss Tippah Tunica Union Clay Pemiscot 3
u C
4 Craighead Mississippi Crittenden Cross Greene Poinsett St. Francis Bollinger Butler Cape Girardeau Dunklin Madison Mississippi New Madrid Scott Stoddard Alexander Hardin Johnson Massac Pope Pulaski Union Tenn-Tom Waterway Tennessee River Ohio River Tennessee River mberland River ee Te n n ess R vi er ss Missi ippi River Nashville 1
Knoxville Memphis Chattanooga Florence Poplar Bluff Jonesboro Decatur Huntsville 1
2 1-2 3
4 7
2 3
4-5 6
7 8
6 Appendix to Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page A-3
Port Name Lash Intermodal Terminal Company (LITCO)
Location City Memphis County Shelby State Tennessee River Mississippi River River Mile 725.0 Dist. to Hwy.
I-55 < 1 mile Dist. to Rail On site, CN, BN Site Acres Developed 12 Acres Owned 12 Topography Flat Facilities Docks 1 dock Buildings 287,000 sq. ft.
Equipment 25 ton crane Services Offered Truck/Barge/Rail Business General cargo on lash barges Contact Terminal Owner The Memphis and Shelby County Port Commission Terminal Operator Cooper T Smith Appendix to Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page A-4
LASH INTERMODAL TERMINAL COMPANY (LITCO)
Illinois Missouri Arkansas Alabama Mississippi Georgia North Carolina Kentucky Tennessee Colbert De Kalb Jackson Lauderdale Lawrence Limestone Madison Marshall Morgan Franklin Ballard Muhlenberg Catoosa Dade Dawson Fannin Pickens Whitfield Alcorn Benton Marshall Tate Tishomingo Lee Adair Pulaski Simpson Allen Monroe Barren Russell Bollinger Alexander Massac Butler Caldwell Calloway Carlisle Marshall Todd Casey Wayne Christian Clinton Crittenden Taylor Cumberland Edmonson Fulton Hart Graves Green Hickman Hopkins Livingston Logan Lyon McCracken McCreary Metcalfe Trigg Wa rre n Wa y n e Whitley Chattooga Lumpkin Wa lke r Gilmer Gordon Murray Union Cherokee Graham De Soto Prentiss Tippah Tunica Union Clay Pemiscot 3
u C
4 Craighead Mississippi Crittenden Cross Greene Poinsett St. Francis Butler Cape Girardeau Dunklin Madison Mississippi New Madrid Scott Stoddard Hardin Johnson Pope Pulaski Union Tenn-Tom Waterway Tennessee River Ohio River Tennessee River mberland River ee R Te n n ess i e v r Mississippi River Nashville 1
Knoxville Memphis Chattanooga Paducah Florence Poplar Bluff Jonesboro Decatur Huntsville 1
2 1-2 3
4 7
2 3
4-5 6
7 8
6 Appendix to Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page A-5
Port Name Fullen Dock and Warehouse, Memphis Wharves Location City Memphis County Shelby State Tennessee River Mississippi River River Mile 740.3 Dist. To Hwy.
Near I-40 and I-55 < 20 miles Dist. To Rail CSX, BN, UP, NS Site Acres Developed Acres Owned 640 Topography Flat Facilities Docks 6 docks Buildings
+500,000 sq. ft. of covered; 750,000 sq. ft. paved Equipment Cranes to 100 tons, buckets to 7 yards Services Offered Truck/Rail/Barge Business Containers on barge, steel, aggregates, general cargo Contact Terminal Owner/Operator Fullen Dock & Warehouse, Inc.
Appendix to Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page A-6
FULLEN DOCK AND WAREHOUSE, MEMPHIS WHARVES Illinois Missouri Arkansas Alabama Mississippi Georgia North Carolina Kentucky Tennessee Colbert De Kalb Jackson Lauderdale Lawrence Limestone Madison Marshall Morgan Franklin Ballard Catoosa Dade Dawson Fannin Gordon Lumpkin Pickens Whitfield Alcorn Marshall Tate Tishomingo Tunica Adair Pulaski Poplar Bluff Allen Monroe Barren Russell Bollinger Alexander Massac Butler Caldwell Calloway Carlisle Trigg Casey Wayne Christian Wa rre n Clinton Crittenden Cumberland Wa y n e Edmonson Hart Taylor New Madrid 7 Fulton Graves Green Hickman Hopkins Livingston Logan Lyon McCracken McCreary Marshall Metcalfe Muhlenberg Simpson Todd Whitley Chattooga Wa lke r Gilmer Murray Union Cherokee Graham Lee Benton De Soto Tippah Clay Pemiscot 3
u C
4 2
Prentiss Union Craighead Mississippi Crittenden Cross Greene Poinsett St. Francis Butler Cape Girardeau Dunklin Madison Mississippi Scott Stoddard Hardin Johnson Pope Pulaski Union Tenn-Tom Waterway Tennessee River Ohio River Tennessee River mberland River ee Te n n ess R vi er ss Missi ippi River Nashville 1
Knoxville Memphis Chattanooga Paducah Florence Jonesboro Decatur Huntsville 1
2 1-2 3
4 3
4-5 6
7 8
6 Appendix to Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page A-7
Port Name West Tennessee Terminals, LLC Location City Halls County Lauderdale State TN River Mississippi River River Mile 818.5 Dist. To Hwy.
Hwy. 88 < 1 mile Dist. To Rail None Site Acres Developed 25 Acres Owned 25 Topography flat Facilities Docks 300 ft.
Buildings Equipment Hydraulic excavator and material handler Services Offered Truck/Barge Business Dry bulk, fertilizer, aluminum, steel, scrap, grain Contact Terminal Owner Cargill Terminal Operator West Tennessee Terminals, LLC Appendix to Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page A-8
WEST TENNESSEE TERMINALS, LLC Illinois Missouri Arkansas Alabama Mississippi Georgia North Carolina Kentucky Tennessee Colbert De Kalb Jackson Lauderdale Lawrence Limestone Madison Marshall Morgan Franklin Ballard Muhlenberg Catoosa Dade Dawson Fannin Pickens Whitfield Marshall Tate Tishomingo Adair Pulaski Poplar Bluff Allen Monroe Barren Russell Bollinger Alexander Massac Butler Caldwell Calloway Carlisle Marshall Trigg Casey Wayne Christian Wa rre n Clinton Crittenden Cumberland Edmonson Fulton Graves Green Hart Hickman Hopkins Livingston Logan Lyon McCracken McCreary Metcalfe Simpson Taylor Todd Wa y n e Whitley Chattooga Gordon Lumpkin Wa lke r Gilmer Murray Union Cherokee Graham Lee Alcorn Benton De Soto Prentiss Tippah Tunica Union Clay Pemiscot 3
u C
4 Craighead Mississippi Crittenden Cross Greene Poinsett St. Francis Butler Cape Girardeau Dunklin Madison Mississippi New Madrid Scott Stoddard Hardin Johnson Pope Pulaski Union Tenn-Tom Waterway Tennessee River Ohio River Tennessee River mberland River T n e e n ssee Riv r e
Mississippi River Nashville 1
Knoxville Memphis Chattanooga Paducah Florence Jonesboro Decatur Huntsville 1
2 1-2 3
4 7
2 3
4-5 6
7 8
6 Appendix to Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page A-9
Port Name Winn Materials Location City Clarksville County Montgomery State Tennessee River Cumberland River River Mile 123.9 Dist. To Hwy.
I-24 < 7 miles Dist. To Rail none Site Acres Developed Acres Owned Topography Flat Facilities Docks Mooring structures Buildings Equipment Services Offered Truck/barge Business Limestone products, sand, general cargo Contact Terminal Owner/Operator Winn Materials Appendix to Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page A-10
WINN MATERIALS Illinois Missouri Arkansas Alabama Mississippi Georgia North Carolina Kentucky Tennessee Colbert De Kalb Jackson Lauderdale Lawrence Limestone Madison Marshall Morgan Franklin Ballard Catoosa Dade Dawson Fannin Gordon Pickens Whitfield Alcorn Marshall Tate Tishomingo Adair Pulaski Poplar Bluff Allen Monroe Barren Russell Bollinger Alexander Butler Caldwell Calloway Carlisle Trigg Casey Wayne Christian Clinton Crittenden Cumberland Edmonson Fulton Graves Green Hart Hickman Hopkins Livingston Logan Lyon McCracken McCreary Marshall Metcalfe Muhlenberg Simpson Taylor Todd Wa rre n Wa y n e Whitley Chattooga Lumpkin Tippah Gilmer Murray Union Wa lke r Cherokee Graham Lee Benton Huntsville 2
De Soto Prentiss Tunica Union Clay Pemiscot 3
u C
4 Craighead Mississippi Crittenden Cross Greene Poinsett St. Francis Butler Cape Girardeau Dunklin Madison Mississippi New Madrid Scott Stoddard Hardin Johnson Massac Pope Pulaski Union Tenn-Tom Waterway Tennessee River Ohio River Tennessee River mberland River ee Te n n ess R vi er ss Missi ippi River Nashville 1
Knoxville Memphis Chattanooga Paducah Florence Jonesboro Decatur 1
2 1-2 3
4 7
3 4-5 6
7 8
6 Appendix to Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page A-11
Port Name Hunter Marine Transport, Inc.
Location City Nashville County Davidson State Tennessee River Cumberland River River Mile 175.5 Dist. To Hwy.
I-40 < 3 miles; Hwy. 155 < 2 miles Dist. To Rail CSX connection Site Acres Developed 22 Acres Owned 32 Topography Flat Facilities Docks 2 docks Buildings 100,000 sq. ft.
Equipment Cranes, conveyors Services Offered Barge, Truck, Rail Business Steel, dry bulk, coke, sand, salt, stone, equipment, coal, fertilizer Contact Terminal Owner/Operator Hunter Marine Transport, Inc Appendix to Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page A-12
HUNTER MARINE TRANSPORT, INC.
Illinois Missouri Arkansas Alabama Mississippi Georgia North Carolina Kentucky Tennessee Colbert De Kalb Jackson Lauderdale Lawrence Limestone Madison Marshall Morgan Franklin Ballard Catoosa Dade Dawson Fannin Lumpkin Pickens Whitfield Benton Marshall Tate Tishomingo Tunica Lee Adair Pulaski Simpson Allen Monroe Barren Russell Bollinger Alexander Massac Butler Caldwell Calloway Carlisle Marshall Todd Casey Wayne Paducah Christian Clinton Crittenden Taylor Cumberland Wa y n e Edmonson Fulton Graves Green Hart Hickman Hopkins Livingston Logan Lyon McCracken McCreary Metcalfe Muhlenberg Trigg Wa rre n Whitley Chattooga Gordon Wa lke r Gilmer Murray Union Cherokee Graham Alcorn De Soto Prentiss Tippah Union Clay Pemiscot 3
u C
4 Craighead Mississippi Crittenden Cross Greene Poinsett St. Francis Butler Cape Girardeau Dunklin Madison Mississippi New Madrid Scott Stoddard Hardin Johnson Pope Pulaski Union Tenn-Tom Waterway Tennessee River Ohio River Tennessee River mberland River T n e nessee Ri e v r ss Missi ippi River Nashville 1
Knoxville Memphis Chattanooga Florence Poplar Bluff Jonesboro Decatur Huntsville 1
2 1-2 3
4 7
2 3
4-5 6
7 8
6 Appendix to Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page A-13
Port Name Haileys Harbor River Transportation Terminal Location City Nashville County Davidson State Tennessee River Cumberland River River Mile 180.1 Dist. To Hwy.
Hwy. 155 < 1 mile; I-40 < 8 miles; I-24 < 10 miles Dist. To Rail Nashville and Western on-site Site Acres Developed 34 Acres Owned 34 Topography flat Facilities Docks 1
Buildings Open Equipment Cranes, conveyors, material handlers Services Offered Truck, Rail, Barge Business Steel, scrap, coal, salt, dry bulk, general commodities Contact Terminal Owner/Operator Haileys Harbor Intermodal River Terminal Appendix to Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page A-14
HAILEYS HARBOR RIVER TRANSPORTION TERMINAL Illinois Missouri Arkansas Alabama Mississippi Georgia North Carolina Kentucky Tennessee Colbert De Kalb Jackson Lauderdale Lawrence Limestone Madison Marshall Morgan Franklin Ballard Catoosa Dade Dawson Fannin Gordon Pickens Whitfield Alcorn Marshall Tate Tishomingo Adair Pulaski Poplar Bluff Allen Monroe Barren Cumberland Russell Wa y n e Butler Caldwell Calloway Carlisle Marshall Todd Casey Wayne Christian Clinton Crittenden Taylor Edmonson Hart New Madrid 7 Fulton Graves Green Hickman Hopkins Livingston Logan Lyon McCracken McCreary Metcalfe Muhlenberg Simpson Trigg Wa rre n Whitley Chattooga Lumpkin Wa lke r Gilmer Murray Union Cherokee Graham Lee Benton Huntsville 2
De Soto Prentiss Tippah Tunica Union Clay Pemiscot 3
u C
4 Craighead Mississippi Crittenden Cross Greene Poinsett St. Francis Bollinger Butler Cape Girardeau Dunklin Madison Mississippi Scott Stoddard Alexander Hardin Johnson Massac Pope Pulaski Union Tenn-Tom Waterway Tennessee River Ohio River Tennessee River mberland River ee Te n n ess R vi er ss Missi ippi River Nashville 1
Knoxville Memphis Chattanooga Paducah Florence Jonesboro Decatur 1
2 1-2 3
4 3
4-5 6
7 8
6 Appendix to Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page A-15
Port Name Cherokee Marine Terminals Location City Nashville County Davidson State Tennessee River Cumberland River River Mile 189.9 Dist. To Hwy.
I-24 adjacent Dist. To Rail CSX Site Acres Developed 29 Acres Owned 29 Topography flat Facilities Docks 3
Buildings 160,000 sq. ft.
Equipment Cranes Services Offered Barge, Truck, Rail Business Steel, heavy lifts, general cargo Contact Terminal Owner/Operator Cherokee Marine Terminal Appendix to Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page A-16
CHEROKEE MARINE TERMINALS Illinois Missouri Arkansas Alabama Mississippi Georgia North Carolina Kentucky Tennessee Colbert De Kalb Jackson Lauderdale Lawrence Limestone Madison Marshall Morgan Franklin Ballard Catoosa Dade Dawson Fannin Pickens Whitfield Alcorn Benton Marshall Tate Tishomingo Lee Adair Pulaski Poplar Bluff Allen Monroe Barren Russell Bollinger Alexander Massac Butler Caldwell Calloway Carlisle Marshall Todd Casey Wayne Paducah Christian Clinton Crittenden Cumberland Edmonson Hart Taylor New Madrid 7 Fulton Hickman Graves Green Hopkins Livingston Logan Lyon McCracken McCreary Metcalfe Muhlenberg Simpson Trigg Wa rre n Wa y n e Whitley Tunica Union Chattooga Gordon Lumpkin Tippah Gilmer Murray Union Wa lke r Cherokee Graham De Soto Prentiss Clay Pemiscot 3
u C
4 Craighead Mississippi Crittenden Cross Greene Poinsett St. Francis Butler Cape Girardeau Dunklin Madison Mississippi Scott Stoddard Hardin Johnson Pope Pulaski Union Tenn-Tom Waterway Tennessee River Ohio River Tennessee River mberland River T n e e n ssee Riv r e
Mississippi River Nashville 1
Knoxville Memphis Chattanooga Florence Jonesboro Decatur Huntsville 1
2 1-2 3
4 2
3 4-5 6
7 8
6 Appendix to Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page A-17
Port Name Herbert Sangravl Co., New Johnsonville Docks Location City New Johnsonville County Humphreys State Tennessee River Tennessee River River Mile 100.4 Dist. to Hwy.
I 10 mi.; US 5 mi.
Dist. to Rail Rail on site Site Acres Developed 15 Acres Owned 15 Topography Flat Facilities Docks Mooring cells Buildings None Equipment (1) 150 ton crane; (1) floating crane; 4-yard clam bucket; 200 tph conveyor Services Offered Truck/ground/rail/barge service Business Aggregates, steel, coke, livilite, coal, ore, sand, aluminum Contact Terminal Owner Ingram Materials Terminal Operator Sangravl Company Appendix to Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page A-18
HERBERT SANGRAVL CO., NEW JOHNSONVILLE DOCKS Illinois Missouri Arkansas Alabama Mississippi Georgia North Carolina Kentucky Tennessee Colbert De Kalb Jackson Lauderdale Lawrence Limestone Madison Marshall Morgan Franklin Ballard Catoosa Dade Dawson Fannin Pickens Whitfield Alcorn Benton Marshall Tate Tishomingo Lee Adair Pulaski Simpson Allen Monroe Barren Cumberland Russell Wa y n e Butler Caldwell Calloway Carlisle Marshall Todd Casey Wayne Paducah Christian Clinton Crittenden Taylor Edmonson Fulton Graves Green Hart Hickman Hopkins Livingston Logan Lyon McCracken McCreary Metcalfe Muhlenberg Trigg Wa rre n Whitley Chattooga Gordon Lumpkin Wa lke r Gilmer Murray Union Cherokee Graham De Soto Prentiss Tippah Tunica Union Clay Pemiscot 3
u C
4 Craighead Mississippi Crittenden Cross Greene Poinsett St. Francis Bollinger Butler Cape Girardeau Dunklin Madison Mississippi New Madrid Scott Stoddard Alexander Hardin Johnson Massac Pope Pulaski Union Tenn-Tom Waterway Tennessee River Ohio River Tennessee River mberland River T n e e n ssee Riv r e
Mississippi River Nashville 1
Knoxville Memphis Chattanooga Florence Poplar Bluff Jonesboro Decatur Huntsville 1
2 1-2 3
4 7
2 3
4-5 6
7 8
6 Appendix to Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page A-19
Port Name Port of Nickajack, Inc.
Location City South Pittsburg County Marion State Tennessee River Tennessee River River Mile 423.7 Dist. to Hwy.
ST-156 adjacent Dist. to Rail No rail on site Site Acres Developed 3
Acres Owned 8
Topography Flat Facilities Docks 800 ft. river frontage with 40 ft. crane cell and (3) 20 ft.
mooring cells; capacity is one working with 4 fleeted Buildings No storage buildings Equipment Crane with 40,000 lb. capacity at 40 ft.; 5 cy. clam bucket; 82 magnet Services Offered Transload from barge to truck and to ground storage Business Pig iron, steel, forest products, aggregates, coal Contact Terminal Owner Nickajack Port Authority Terminal Operator Parker Towing Company Appendix to Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page A-20
PORT OF NICKAJACK, INC.
Illinois Missouri Arkansas Alabama Mississippi Georgia North Carolina Kentucky Tennessee Colbert De Kalb Jackson Lauderdale Lawrence Limestone Madison Marshall Morgan Franklin Catoosa Dade Dawson Fannin Pickens Whitfield Alcorn Marshall Tate Tishomingo Memphis Chattanooga 6
Adair Pulaski Simpson Allen Ballard Barren Butler Caldwell Hopkins Muhlenberg Calloway Carlisle Marshall Todd Casey Wayne Paducah Christian Clinton Crittenden Taylor Cumberland Wa y n e Edmonson Fulton Graves Green Hart Hickman Livingston Logan Lyon McCracken McCreary Metcalfe Monroe Russell Trigg Wa rre n Whitley Chattooga Gordon Lumpkin Wa lke r Gilmer Murray Union Cherokee Graham Lee Benton De Soto Tippah Clay Pemiscot 3
u C
4 2
Prentiss Tunica Union Craighead Mississippi Crittenden Cross Greene Poinsett St. Francis Bollinger Butler Cape Girardeau Dunklin Madison Mississippi New Madrid Scott Stoddard Alexander Hardin Johnson Massac Pope Pulaski Union Tenn-Tom Waterway Tennessee River Ohio River Tennessee River mberland River ee T
ss enne Ri e v r ss Missi ippi River Nashville 1
Knoxville Florence Poplar Bluff Jonesboro Decatur Huntsville 1
2 1-2 3
4 7
3 4-5 7
8 6
Appendix to Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page A-21
Port Name Mid South Terminals, Division of Serodino, Inc.
Location City Chattanooga County Hamilton State Tennessee River Tennessee River River Mile 456.2 Dist. To Hwy.
I-24 via US 27 Dist. To Rail Rail on site Site Acres Developed Three sites - (2) 1.5 acre and (1) 15 acre site at 456.5 that is inactive at this time Acres Owned 18 Topography Flat Facilities Docks 1,600 ft. river frontage with many dolphins and cells along the main channel of the river as well as the barge slip area Buildings None Equipment (2) 70 ton cranes on 25 ft. cells; (2) 100 ton cranes -
American 999C crawler; Manitowoc 4000 crawler Services Offered Barge to truck/ground/rail/liquid storage Truck/ground/rail/liquid to barge Business Iron, steel, coal, coke, grain and aggregates Contact Terminal Owner/Operator Serodino, Inc.
Appendix to Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page A-22
MID-SOUTH TERMINALS, DIVISION OF SERODINO, INC.
Illinois Missouri Arkansas Alabama Mississippi Georgia North Carolina Kentucky Tennessee Colbert De Kalb Jackson Lauderdale Lawrence Limestone Madison Marshall Morgan Franklin Ballard Muhlenberg Catoosa Dade Fannin Gilmer Gordon Pickens Wa lke r Whitfield Marshall Tate Tippah Tishomingo Adair Pulaski Poplar Bluff Allen Monroe Barren Russell Bollinger Alexander Massac Butler Caldwell Calloway Carlisle Marshall Todd Casey Wayne Christian Clinton Crittenden Cumberland Edmonson Fulton Graves Green Hart Hickman Hopkins Livingston Logan Lyon McCracken McCreary Metcalfe Simpson Taylor Trigg Wa rre n Wa y n e Whitley Tunica Union Chattooga Lumpkin Dawson Murray Union Cherokee Graham Alcorn Lee Benton De Soto Prentiss Decatur Clay Pemiscot 3
u C
4 Craighead Mississippi Crittenden Cross Greene Poinsett St. Francis Butler Cape Girardeau Dunklin Madison Mississippi New Madrid Scott Stoddard Hardin Johnson Pope Pulaski Union Tenn-Tom Waterway Tennessee River Ohio River Tennessee River mberland River ee Te n n ess Ri e v r Mississippi River Nashville 1
Knoxville Memphis Chattanooga Paducah Florence Jonesboro Huntsville 1
2 1-2 3
4 7
2 3
4-5 6
7 8
6 Appendix to Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page A-23
Port Name JIT Terminals Location City Chattanooga County State Tennessee River Tennessee River River Mile 463.8 Dist. To Hwy.
Hwy. 27 adjacent, I-24 < 3miles Dist. To Rail Connection to NS Site Acres Developed 30 Acres Owned 30 Topography Flat Facilities Docks Mooring structures Buildings 155,000 sq. ft.
Equipment 70 ton crane Services Offered Truck/Barge/Rail Business Steel, liquids & general cargo Contact Terminal Owner/Operator JIT Terminals, Inc Appendix to Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page A-24
JIT TERMINALS Illinois Missouri Arkansas Alabama Mississippi Georgia North Carolina Kentucky Tennessee Colbert De Kalb Jackson Lauderdale Lawrence Limestone Madison Marshall Morgan Franklin Ballard Catoosa Dade Dawson Fannin Gordon Pickens Whitfield Marshall Tate Tishomingo Tunica Adair Pulaski Poplar Bluff Allen Monroe Barren Russell Bollinger Alexander Massac Butler Caldwell Calloway Carlisle Marshall Todd Casey Wayne Paducah Christian Clinton Crittenden Cumberland Edmonson Fulton Graves Green Hart Hickman Hopkins Livingston Logan Lyon McCracken McCreary Metcalfe Muhlenberg Simpson Taylor Trigg Wa rre n Wa y n e Whitley Union Chattooga Lumpkin Wa lke r Gilmer Murray Union Cherokee Graham Lee Alcorn Benton De Soto Prentiss Tippah Clay Pemiscot 3
u C
4 Craighead Mississippi Crittenden Cross Greene Poinsett St. Francis Butler Cape Girardeau Dunklin Madison Mississippi New Madrid Scott Stoddard Hardin Johnson Pope Pulaski Union Tenn-Tom Waterway Tennessee River Ohio River Tennessee River mberland River ee Te n n ess R vi er ss Missi ippi River Nashville 1
Knoxville Memphis Chattanooga Florence Jonesboro Decatur Huntsville 1
2 1-2 3
4 7
2 3
4-5 6
7 8
6 Appendix to Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page A-25
Port Name Centre South Riverport Location City Chattanooga County State Tennessee River Tennessee River River Mile 466.5 Dist. To Hwy.
Hwy. 58 adjacent, I-24 < 10miles Dist. To Rail Connection to NS Site Acres Developed 15 Acres Owned 15 Topography Flat Facilities Docks Mooring Structures Buildings Open Equipment 150 ton crane Services Offered Truck/Barge/Rail Business Steel, bulk and break-bulk Contact Terminal Owner Hamilton County Terminal Operator Parker Towing Appendix to Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page A-26
CENTRE SOUTH RIVERPORT Illinois Missouri Arkansas Alabama Mississippi Georgia North Carolina Kentucky Tennessee Colbert De Kalb Jackson Lauderdale Lawrence Limestone Madison Marshall Morgan Franklin Ballard Catoosa Dade Dawson Fannin Lumpkin Pickens Whitfield Alcorn Marshall Tate Tishomingo Tunica Adair Pulaski Simpson Allen Monroe Barren Cumberland Russell Wa y n e Butler Caldwell Calloway Carlisle Casey Christian Clinton Crittenden Edmonson Fulton Graves Green Hart Hickman Hopkins Livingston Logan Lyon McCracken McCreary Marshall Metcalfe Muhlenberg Taylor Todd Trigg Wa rre n Whitley Chattooga Gilmer Gordon Murray Union Wa lke r Cherokee Graham Benton De Soto Prentiss Tippah Union Clay Craighead Crittenden Cross Greene Lee Mississippi Poinsett St. Francis Bollinger Butler Cape Girardeau Dunklin Madison Mississippi New Madrid Pemiscot Scott Stoddard Wayne Alexander Hardin Johnson Massac Pope Pulaski Union Tenn-Tom Waterway Tennessee River Ohio River Tennessee River Cumberland River ee T
ss enne Ri e v r ss Missi ippi River Nashville 1
Knoxville Memphis Chattanooga Paducah Florence Poplar Bluff Jonesboro Decatur Huntsville 1
2 3 4 1-2 3
4 7
2 3
4-5 6
7 8
6 Appendix to Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page A-27
Port Name Fort Loudon Terminal Location City Lenoir City County Loudon State Tennessee River Tennessee River River Mile 600.2 Dist. To Hwy.
I-40 and I-75 are within 3 miles Dist. To Rail Rail on site Site Acres Developed 11 Acres Owned 22 Topography 80% flat; 20% slightly sloped Facilities Docks Extensive river frontage Buildings (2) storage buildings - 25,000 sq. ft. and 50,000 sq. ft.;
1 acre storage pad Equipment (1) 30 ton crane; (4) other cranes; (2) truck scales Services Offered Truck/ground/rail service Business Iron, salt, forest products, alloys, fertilizers, sand, chemicals, steel, coal, coke, grain and aggregates Contact Terminal Owner/Operator Tennessee Farmers Cooperative Appendix to Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page A-28
FORT LOUDON TERMINAL Illinois Missouri Arkansas Alabama Mississippi Georgia North Carolina Kentucky Tennessee Colbert De Kalb Jackson Lauderdale Lawrence Limestone Madison Marshall Morgan Franklin Ballard Catoosa Dade Dawson Lumpkin Pickens Whitfield Alcorn Benton Marshall Tate Tishomingo Tunica Lee Adair Pulaski Simpson Allen Monroe Barren Russell Bollinger Alexander Massac Butler Caldwell Calloway Carlisle Marshall Todd Casey Wayne Christian Clinton Crittenden Taylor Cumberland Wa y n e Edmonson Hart New Madrid 7 Fulton Poplar Bluff Graves Green Hickman Hopkins Livingston Logan Lyon McCracken McCreary Metcalfe Muhlenberg Trigg Wa rre n Whitley Chattooga Gordon Fannin Wa lke r Gilmer Murray Union Cherokee Graham De Soto Prentiss Tippah Union Clay Pemiscot 3
u C
4 Craighead Mississippi Crittenden Cross Greene Poinsett St. Francis Butler Cape Girardeau Dunklin Madison Mississippi Scott Stoddard Hardin Johnson Pope Pulaski Union Tenn-Tom Waterway Tennessee River Ohio River Tennessee River mberland River T n e nessee Riv r e
Mississippi River Nashville 1
Knoxville Memphis Chattanooga Paducah Florence Jonesboro Decatur Huntsville 1
2 1-2 3
4 2
3 4-5 6
7 8
6 Appendix to Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page A-29
Port Name Burkhart Enterprises, Inc.
Location City Knoxville County Knox State Tennessee River Tennessee River River Mile 652.2 Dist. To Hwy.
I-40 and I-75 are accessible via ST-168 Dist. To Rail Rail on site Site Acres Developed 60 Acres Owned 100 Topography Flat Facilities Docks Nearly one mile of riverfront, 2 docks - 60 ft. concrete, 40 ft. gravel Buildings 24,000 sq. ft. warehouse; 5,000 sq. ft. bulk storage Equipment (1) 100 ton crane; (1) 85 ton crane; (2) truck scales Services Offered Truck/ground/rail/barge service Business Iron, salt, sand, steel, coal, coke and gravel Contact Terminal Owner/Operator Burkhart Enterprises Appendix to Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page A-30
BURKHART ENTERPRISES Mississippi Missouri Alabama Georgia North Carolina Kentucky Illinois Tennessee Colbert De Kalb Jackson Lauderdale Lawrence Limestone Madison Marshall Morgan Franklin Adair Allen Ballard Barren Butler Caldwell Calloway Carlisle Casey Christian Clinton Crittenden Cumberland Edmonson Fulton Graves Green Hart Hickman Hopkins Livingston Logan Lyon McCracken McCreary Marshall Metcalfe Monroe Muhlenberg Pulaski Russell Simpson Taylor Todd Trigg Wa rre n Wa y n e Whitley Catoosa Chattooga Dade Dawson Fannin Gilmer Gordon Lumpkin Murray Pickens Union Wa lke r Whitfield Cherokee Graham Alcorn Benton De Soto Marshall Prentiss Tate Tippah Tishomingo Tunica Union Clay Craighead Crittenden Cross Greene Lee Mississippi Poinsett St. Francis Bollinger Butler Cape Girardeau Dunklin Madison Mississippi New Madrid Pemiscot Scott Stoddard Wayne Alexander Hardin Johnson Massac Pope Pulaski Union Tenn-Tom Waterway Tennessee River Tennessee River Cumberland River Tennessee River Mississippi River Ohio River Nashville Knoxville Memphis Chattanooga Paducah Florence Poplar Bluff Jonesboro Decatur Huntsville 1
2 3 4 1-2 3
4 7
1 2
3 4-5 6
7 8
6 Arkansas Appendix to Tennessee Waterway Assessment Study Hanson Professional Services Inc.
Page A-31