Text

I RIC)RITY ACCELERATED RIDS PROCESSING)

REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)

. ACCESSION NBR:9512180127 DOC.DATE: 95/12/11 NOTARIZED: NO FACIL:50-400 Shearon Harris Nuclear Power Plant, Unit 1, Carolina AUTH.NAME AUTHOR AFFILIATION ROBINSON,W.R.

Carolina Power

& Light Co.

RECIP.NAME RECIPIENT AFFILIATION Document Control Branch (Document Control Desk)

SUBJECT:

Forwards revised "Semi-Annual Effluent Release Rept for Period of Jul-Dec 1994." Attachment to ltr provides revised pages w/corrected values.

DXSTRIBUTION CODE:

IE48D COPIES RECEIVED:LTR ENCL SXZE:

TITLE: 50.36a(a)(2)

Semiannual Effluent Release Reports DOCKET 05000400 NOTES:Application for permit renewal filed.

o5ooo4oo RECIPIENT ID CODE/NAME PD2-1 LA LE,N INTERNAL: ACRS NRR/DRPM/PERB/B RGN2 FXLE EXTERNAL: BNL TICHLERiJ NRC PDR COPIES LTTR ENCL 2

2 1

1 1

1 1

1 1

1 1

1 1

1 RECIPIENT ID CODE/NAME PD2-1 PD FIL'ENT R 0

'GN2~H88PB LITCO AKERS I D COPIES LTTR ENCL 1

1 1

1 2

2 1

1 NOTE TO ALL"RIDS" RECIPIENTS:

PLEASE HELP US TO REDUCE KVKSTE!CONTACT'I'HE DOCL'CLIENTCONTROL DESK, ROOXI P 1-37 (EXT. "(8-~OS3 ) TO ELIX!INKTE YOI'R NAZIL I'ROTI DISTRI8 U'I'ION LISTS I'OR DOC!.'NIEN'I'SYOL'ON"I'l.'I;D!

TOTAL NUMBER OF COPIES REQUIRED:

LTTR 13 ENCL 13

Carolina Power &Light Company PO Box 165 New Hill NC 27562 William R. Robinson Vice President Harris Nuclear Plant DEC 11 1995 SERIAL: HNP-95-108 United States Nuclear Regulatory Commission ATTENTION: Document Control Desk Washington, DC 20555 SHEARON HARMS NUCLEARPOWER PLANT DOCKET NO. 50-400/LICENSE NO. NPF-63 SEMIANNUALRADIOLOGICALEFFLUENT RELEASE REPORT CORRECTION Gentlemen:

On February 26, 1995, Carolina Power & Light Company (CP&L) submitted the Harris Nuclear Plant (HNP) Semiannual Radiological Effluent Release Report for the period of July 1, 1994 through December 31, 1994.

As noted in NRC Inspection Report 50-400/95-09, dated June 16, 1995, some values in the 1994 report inappropriately repeated the values reported for 1993.

The attachment to this letter provides revised pages with corrected values.

In addition to correcting these values, CP&L has reviewed the entire report for accuracy.

The attached pages include the following additional changes to "Enclosure 4: Major Assumptions Used to Calculate Radiation Doses ":

~

reflects updated USGS figures for Cape Fear River average flow,

~

corrected reference to the Environmental Report versus the FSAR for Harris I Ne average flow,

~

deletion of Harris I eke as a source of drinking water, and

~

revised the description for the assumption regarding the Maximum Hypothetical Individual.

Inspection Report 95-09, Report Details - Section 5, lists the beta air dose to the Maximum Hypothetical Individual as 8.02 E-2 inrad.

This value should be 8.11 E-2 mrad as shown on the attached page 9/7.

CP&L has also reviewed the report for the first two quarters of 1994.

No discrepanceis were noted in that report.

LBOO" 3 9512180127 951211 PDR ADQCK 05000400 R;

',PDR

  • %4 Jk I

State Road1134 New Hill NC Tel 919362-2502 Fax 919362-2095 gg)P I

t

Questions regarding this matter may be referred to Mr. T. D. Walt at (919) 362-2711.

Sincerely, SDC/sdc Attachment c: