1 NuScaleDCRaisPEm Resource From:

Cranston, Gregory Sent:

Monday, January 08, 2018 8:55 AM To:

RAI@nuscalepower.com Cc:

NuScaleDCRaisPEm Resource; Lee, Samuel; Chowdhury, Prosanta; Burkhart, Lawrence; Williams, Stephen; Markley, Anthony

Subject:

Request for Additional Information No. 322 RAI No. 9239 (11.2)

Attachments:

Request for Additional Information No. 322 (eRAI No. 9239).pdf Attached please find NRC staffs request for additional information concerning review of the NuScale Design Certification Application.

Please submit your technically correct and complete response within 60 days of the date of this RAI to the NRC Document Control Desk.

If you have any questions, please contact me.

Thank you.

Gregory Cranston, Senior Project Manager Licensing Branch 1 (NuScale)

Division of New Reactor Licensing Office of New Reactors U.S. Nuclear Regulatory Commission 301-415-0546

Hearing Identifier:

NuScale_SMR_DC_RAI_Public Email Number:

349 Mail Envelope Properties (CY4PR09MB1287C6F476D2FE197888517190130)

Subject:

Request for Additional Information No. 322 RAI No. 9239 (11.2)

Sent Date:

1/8/2018 8:54:48 AM Received Date:

1/8/2018 8:54:52 AM From:

Cranston, Gregory Created By:

Gregory.Cranston@nrc.gov Recipients:

"NuScaleDCRaisPEm Resource" <NuScaleDCRaisPEm.Resource@nrc.gov>

Tracking Status: None "Lee, Samuel" <Samuel.Lee@nrc.gov>

Tracking Status: None "Chowdhury, Prosanta" <Prosanta.Chowdhury@nrc.gov>

Tracking Status: None "Burkhart, Lawrence" <Lawrence.Burkhart@nrc.gov>

Tracking Status: None "Williams, Stephen" <Stephen.Williams@nrc.gov>

Tracking Status: None "Markley, Anthony" <Anthony.Markley@nrc.gov>

Tracking Status: None "RAI@nuscalepower.com" <RAI@nuscalepower.com>

Tracking Status: None Post Office:

CY4PR09MB1287.namprd09.prod.outlook.com Files Size Date & Time MESSAGE 556 1/8/2018 8:54:52 AM Request for Additional Information No. 322 (eRAI No. 9239).pdf 28136 Options Priority:

Standard Return Notification:

No Reply Requested:

No Sensitivity:

Normal Expiration Date:

Recipients Received:

Request for Additional Information No. 322 (eRAI No. 9239)

Issue Date: 01/08/2018 Application

Title:

NuScale Standard Design Certification 048 Operating Company: NuScale Power, LLC Docket No.52-048 Review Section: 11.02 - Liquid Waste Management System Application Section: 11.2 QUESTIONS 11.02-2 11.2 RAI - Determining the basis for the dilution flow rates.

Regulatory Basis: 10 CFR Part 20, Appendix B; 10 CFR Part 50, Appendix I 10 CFR Part 20, Appendix B, Table 2 provides concentration limits for airborne and liquid effluents released to the general environment. 10 CFR Part 50, Appendix I provides the numerical guidance for design objectives and limiting conditions for operation.

Key Issue:

There is not sufficient information in the DCD regarding the dilution flows that are needed to determine effluent concentrations released are within regulatory limits Questions

1. In review of DCD section 11.2.3.3, the staff requests additional information for the stated dilution flows referenced by the applicant in DCD Section 11.2.3.3, and DCD Table 11.2-4. The dilution flows are needed to determine the effluent concentrations released by the applicant for compliance with 10 CFR Part 20, Appendix B; and 10 CFR Part 50, Appendix I.

As discussed during the audit, the applicant references 5.56 cfs for the UWS dilution flow, and 740 cfs for the offsite dilution factor. DCD section 11.2.3.3 provides a pointer to DCD section 9.2.9, but the staff is unable to find any stated flow rates that feed into the 5.56 cfs dilution flow value. The staff requests explanation for the basis of the flow rates used for both 10 CFR Part 20 Appendix B Table 2, and 10 CFR Part 50 Appendix I compliance. In the audit it was discussed that the 740 cfs values was based on an assumed river dilution. The staff would need such assumptions to be stated in the DCD for the staff to understand the basis for the developed dilution flows.

2. The staff requests the applicant to provide and list the flow rate inputs used in DCD Section 11.2 to determine the 5.56 cfs flow rate value from the UWS. In addition, the staff requests the applicant to clearly state the assumption for the 740 cfs flow rate value as was discussed during the audit. The staff request the applicant clearly state assumptions in the DCD and provide a markup of the DCD in response to this RAI.