ML18004A008

From kanterella
Jump to navigation Jump to search
La -
ML18004A008
Person / Time
Site: Seabrook 
Issue date: 01/02/2018
From:
NRC
To:
Division of Operating Reactor Licensing
References
17-953-02-LA-BD01
Download: ML18004A008 (13)


Text

1 SeabrookLANPEm Resource From:

SeabrookLAHearingFile Resource Sent:

Tuesday, January 02, 2018 2:42 PM To:

SeabrookLANPEm Resource Attachments:

170444-SVR-01-R0.pdf

Hearing Identifier:

Seabrook_LA_NonPublic Email Number:

1342 Mail Envelope Properties (fb0d17365c9f4e0495c6932dfdf3ebd4)

Subject:

Sent Date:

1/2/2018 2:42:00 PM Received Date:

1/2/2018 2:42:06 PM From:

SeabrookLAHearingFile Resource Created By:

SeabrookLAHearingFile.Resource@nrc.gov Recipients:

"SeabrookLANPEm Resource" <SeabrookLANPEm.Resource@nrc.gov>

Tracking Status: None Post Office:

HQPWMSMRS01.nrc.gov Files Size Date & Time MESSAGE 3

1/2/2018 2:42:06 PM 170444-SVR-01-R0.pdf 6252914 Options Priority:

Standard Return Notification:

No Reply Requested:

No Sensitivity:

Normal Expiration Date:

Recipients Received:

RI

5(3257$33529$/6+((7



















&OLHQW

1H[W(UD(QHUJ\\6HDEURRN



3URMHFW1R



3URMHFW

6XSSRUWIRU3URPSW2SHUDELOLW\\'HWHUPLQDWLRQV 32'V 1H[W(UD(QHUJ\\6HDEURRN

6WDWLRQ1+





5HSRUW1R

6955



5HSRUW7\\SH

6LWH9LVLW5HSRUW



7LWOH

6HSWHPEHU  7KUHVKROG,QVSHFWLRQV IRU WKH 1RUWK :DOO RI WKH

&RQWDLQPHQW (QFORVXUH 9HQWLODWLRQ $UHD &(9$  1H[W(UD (QHUJ\\

6HDEURRN)DFLOLW\\6HDEURRN1+



1XPEHURISDJHVLQFOXGLQJWKLVSDJH





$UHWKHUHXQYHULILHGDVVXPSWLRQV <1 



1

,VWKLVUHSRUWVDIHW\\UHODWHGSHUFRQWUDFW <1 

<



2EMHFWLYH



7RUHSRUW6HSWHPEHUWKUHVKROGPHDVXUHPHQWUHVXOWVRIWKHORZHUSRUWLRQRIWKH1RUWK

DOO RI WKH &RQWDLQPHQW (QFORVXUH 9HQWLODWLRQ $UHD &(9$  DQG WR GHWHUPLQH ZKHWKHU WKH

WKUHVKROGOLPLWVIRUWKH&(9$1RUWK:DOOKDYHEHHQH[FHHGHG



5HYLVLRQ



'HVFULSWLRQV





,QLWLDO'RFXPHQW



     



     



5HYLVLRQ



3UHSDUHU'DWH

,QGHS9HULILHU'DWH

$SSURYHU'DWH















/L\\LQJ-LDQJ

0LFKDHO0XGORFN

0DWWKHZ56KHUPDQ

     



2FWREHU

2FWREHU

2FWREHU







RI

6,7(9,6,75(325712

'RFXPHQW,'1R6955

5HSRUW%\\/L\\LQJ-LDQJ



'DWHRI6LWH9LVLW

6HSWHPEHU

'DWH5HSRUW,VVXHG

2FWREHU



3URMHFW



.H\\ZRUG

32'6



&RQWUDFW1R

5HOHDVH

([HFXWHG

0DUFK



3URMHFW1DPH6XEMHFW

6XSSRUWIRU3URPSW2SHUDELOLW\\

'HWHUPLQDWLRQV 32'V 1H[W(UD

(QHUJ\\6HDEURRN6WDWLRQ1+

3XUSRVH

3HUIRUPWKUHVKROGLQVSHFWLRQVIRU

WKHQRUWKZDOORI&(9$DV

UHTXLUHGSHUWKHVWUXFWXUDO

HYDOXDWLRQRIWKH&(9$VWUXFWXUH

0HHWLQJ:RUN/RFDWLRQ

6HDEURRN6WDWLRQ

7LPH+/-

IURP

DP



WR

SP

HDWKHU

,QGRRUV

$PELHQW7HPSHUDWXUH

)

5HYLHZHG%\\

0LFKDHO0XGORFN

2FWREHU

$SSURYHG%\\

0DWWKHZ56KHUPDQ

2FWREHU



7KLV6LWH9LVLW5HSRUWFRQVLVWVRIWKHIROORZLQJ





5HSRUW&RQWHQW

&RQWHQW

7LWOH

3DJH

&RYHU6KHHW

5HSRUW$SSURYDO6KHHW



0DLQ5HSRUW

6LWH9LVLW5HSRUW1R6955

+/-

3KRWRJUDSKV

3KRWRJUDSKDQG)LJXUH3DJHV

+/-







/LVWRI7DEOHV

&RQWHQW

7LWOH

3DJH

7DEOH

/LVWRI(TXLSPHQWDQG&DOLEUDWLRQ5HFRUG









/LVWRI)LJXUHV

&RQWHQW

7LWOH

3DJH

)LJXUH

3OXPEQHVVSURILOHRI1RUWK:DOORI&(9$IURP(/IWWR(/IW



6LWH9LVLW5HSRUW1R

RI

2FWREHU

'RFXPHQW,'1R6955



5HYLVLRQ







$EEUHYLDWLRQV

x

1((+/-1H[W(UD(QHUJ\\6HDEURRN//&

x

1((+/-6HDEURRN+/-1H[W(UD(QHUJ\\6HDEURRN)DFLOLW\\

x

6*++/-6LPSVRQ*XPSHUW] +HJHU,QF

x

$65+/-$ONDOL6LOLFD5HDFWLRQ

x

&(%+/-&RQWDLQPHQW(QFORVXUH%XLOGLQJ

x

&%+/-&RQWDLQPHQW%XLOGLQJ

x

$=+/-$]LPXWK

x

&(9$+/-&RQWDLQPHQW(QFORVXUH9HQWLODWLRQ$UHD

x

0HFK3HQ+/-0HFKDQLFDO3HQHWUDWLRQ

)LHOG,QVSHFWRUV

x

/L\\LQJ-LDQJ+/-3ULPDU\\)LHOG,QVSHFWRU6*+

x

3L\\XVK*DUJ+/-)LHOG,QVSHFWRU6*+

3HUVRQV&RQWDFWHG

x

-DFO\\Q+XOEHUW+/-1(1*,,/LFHQVH5HQHZDO1((

x

'DYH&DUOLQR,,,+/-1XFOHDU&RQVWUXFWLRQ/HDG1((



5(9,6,21+,6725<

5HYLVLRQ+/-,QLWLDO'RFXPHQW



,1752'8&7,21

1H[W(UD(QHUJ\\6HDEURRN//& 1(( FRQWUDFWHG6LPSVRQ*XPSHUW] +HJHU,QF 6*+ WR

SHUIRUP VWUXFWXUDO HYDOXDWLRQ RI VHOHFWHG VWUXFWXUHV DW WKH 1H[W(UD (QHUJ\\ 6HDEURRN )DFLOLW\\

1((6HDEURRN  LQ RUGHU WR GHWHUPLQH WKHLU VXVFHSWLELOLW\\ WR FRQFUHWH GHIRUPDWLRQ FDXVHG E\\

$65VZHOOLQJFUHHSDQGVKULQNDJH2Q0DUFK6*+LVVXHGDVWUXFWXUDOHYDOXDWLRQRI

WKH&(9$VWUXFWXUHFRQVLGHULQJVWUHVVHVLQWKHDVGHIRUPHGFRQGLWLRQLQDGGLWLRQWRHDFKRIWKH

ORDG FRPELQDWLRQV LGHQWLILHG LQ WKH 8)6$5 IRU WKH &(9$ VWUXFWXUDO HYDOXDWLRQ 'HWDLOHG

LQIRUPDWLRQLVSURYLGHGLQ6*+'RFXPHQW&$5HYLVLRQ >@LQZKLFK6HFWLRQ

³7KUHVKROG 0RQLWRULQJ 0HDVXUHPHQWV DQG /LPLW' UHFRPPHQGV WKDW DOWKRXJK WKH &(9$

VWUXFWXUHLVHYDOXDWHGDVD6WDJH2QHVWUXFWXUHWKHWKUHVKROGLQVSHFWLRQRIWKHORZHUSRUWLRQRI

WKHQRUWKZDOOEHFRQGXFWHGHYHU\\VL[PRQWKVZLWKWKHIROORZLQJVFRSHRIZRUNDQGDVVRFLDWHG

WKUHVKROGOLPLWV



6LWH9LVLW5HSRUW1R

RI

2FWREHU

'RFXPHQW,'1R6955



5HYLVLRQ







x

0HDVXUHWKHRXWRISOXPEQHVVRIWKHQRUWKZDOOIRUDQ\\LQFUHDVHLQGLVSODFHPHQW,IWKH

FXUUHQWO\\PHDVXUHGPD[LPXPERZLQJRILQUHDFKHVLQ FRUUHVSRQGLQJWRD

LQFUHDVHEH\\RQGWKHFXUUHQWPD[LPXPPHDVXUHGERZLQJ IXUWKHUHYDOXDWLRQRI

WKHZDOOVWDELOLW\\RURWKHUDSSURSULDWHDFWLRQLVUHTXLUHG

x

+DPPHUVRXQGWKHQRUWKIDFH YLVLEOHIDFH RIWKHZDOOEHWZHHQ(/IWDQG(/IW

WRFKHFNIRUDQ\\QHDUVXUIDFHGHODPLQDWLRQ,IDQ\\DUHDZLWKGHODPLQDWHGFRQFUHWHLV

GHWHFWHG FRQVLGHU UHPRYLQJ DQG UHSDLULQJ RU RWKHUZLVH UHVWUDLQLQJ WKH XQVRXQG

FRQFUHWHWRSUHYHQWDQ\\FRQFUHWHVSDOOLQJRIIWKHZDOORQWRWKHHTXLSPHQWDQGVWDLUV

EHORZ

,Q6HSWHPEHUVL[PRQWKVDIWHU6*+LVVXHGWKHVWUXFWXUDODQDO\\VLVHYDOXDWLRQRIWKH&(9$

VWUXFWXUH1((UHTXHVWHGWKDW6*+SHUIRUPWKHWKUHVKROGLQVSHFWLRQVRIWKH&(9$QRUWKZDOO

SHUWKHVFRSHRIZRUNGHVFULEHGDERYH



(48,30(17$1'&$/,%5$7,216

7DEOHSURYLGHVDOLVWRIHTXLSPHQWZLWKDVVRFLDWHGFDOLEUDWLRQGDWDXVHGIRUWKHWKUHVKROG

PHDVXUHPHQWVGXULQJWKLVWDVN



7DEOH+/-/LVWRI(TXLSPHQWDQG&DOLEUDWLRQ5HFRUG

(TXLSPHQW

$VVHW1R0RGHO,'

/DVW&DOLEUDWLRQ

'DWH

&DOLEUDWLRQ'XH

'DWH

IW7DSH0HDVXUH

3UD]3UHFLVLRQ&UDIWHG

+/-

+/-

IW7DSH0HDVXUH

6WDQOH\\3RZHU/RFN

+/-

+/-

9DLVDOD'LJLWDO+\\JURPHWHU

)/6

$XJXVW

)HEUXDU\\

1RW&DOLEUDWHG3HU1((FDOLEUDWLRQFRQWUROVDUHQRWUHTXLUHGIRUVWDQGDUGRIIWKHVKHOIPHDVXULQJHTXLSPHQW UXOHUV

WDSHPHDVXUHVOHYHOVHWF ZKLFKLVQRWOLNHO\\WRFKDQJHRUGULIWGXULQJXVH

1((6HDEURRNFDOLEUDWHGWKLVHTXLSPHQWLQDFFRUGDQFHZLWKWKHLU4$7RSLFDO5HSRUW



6&23(2):25.

2Q  6HSWHPEHU  6*+ SHUIRUPHG WKUHVKROG LQVSHFWLRQV RI WKH QRUWK ZDOO RI WKH &(9$

VWUXFWXUHXQGHU1((6HDEURRN:RUN2UGHUDQG30,'IXUWKHUGHVFULEHG

EHORZ



x

0HDVXUHWKHRXWRISOXPEQHVVRIWKHQRUWKZDOOIRUDQ\\LQFUHDVHLQGLVSODFHPHQW

x

9LVXDOO\\VXUYH\\DQGSHUIRUPDGHODPLQDWLRQVXUYH\\RIWKHQRUWKIDFH YLVLEOHIDFH RIWKH

QRUWKZDOOIURP(/IWWR(/IWZKHUHDFFHVVLEOHWRFKHFNIRUDQ\\QHDUVXUIDFH

GHODPLQDWLRQ

x

'RFXPHQW WKH YLVXDO REVHUYDWLRQV PHDVXUHPHQWV DQG ILQGLQJV LQ D VLWH YLVLW UHSRUW

695 WR1((





 $ GHODPLQDWLRQ LV DQ\\ SODQDU VHSDUDWLRQ LQ D PDWHULDO WKDW LV URXJKO\\ SDUDOOHO WR WKH VXUIDFH RI WKH

PDWHULDOWKDWLVHVVHQWLDOO\\IRUPHGE\\DFUDFNWKDWLVSDUDOOHOWRWKHVXUIDFHRIWKHZDOO>@

6LWH9LVLW5HSRUW1R

RI

2FWREHU

'RFXPHQW,'1R6955



5HYLVLRQ









216,7(7+5(6+2/',163(&7,216$1'5(68/76



DOO3OXPEQHVV0HDVXUHPHQWV

6*+ PHDVXUHG WKH RXWRISOXPEQHVV RI WKH QRUWK IDFH RI WKH QRUWK ZDOO IURP (/  IW WR

(/IWXVLQJDSOXPEEREDQGDWDSHPHDVXUH6*+VXVSHQGHGWKHSOXPEEREIURPDVWULQJ

UXQQLQJDORQJWKHZDOOVXUIDFHIURP(/IWWR(/IW WRSRIWKH0HFK3HQ DQGPHDVXUHG

WKHGLVWDQFHIURPWKHZDOOVXUIDFHWRWKHFHQWHURIWKHVWULQJVWDUWLQJDW(/IW IWIURPWKH

WRSRIWKH0HFK3HQ DQGFRQWLQXLQJWR(/IW IWDERYHWKHWRSRIWKHEDVHVODERIWKH

&(9$%XLOGLQJ  3KRWRVDQG 6*+SHUIRUPHGWKHPHDVXUHPHQWVIURPERWKVLGHVRIWKH

VWDLUVZKLFKDUHORFDWHGQHDUWKHFHQWHURIWKHZDOO

7KHSOXPEQHVVSURILOHRIWKHQRUWKIDFHRIWKHQRUWKZDOODVLOOXVWUDWHGLQ)LJXUHLQGLFDWHV

RXWZDUGEXOJLQJ UHODWLYHWRWKHIDFHRIWKHZDOODW(/IW ZLWKD]RQHRIUHODWLYHO\\XQLIRUP

EXOJLQJSUHVHQWIURP(/IWWR(/IWZLWKWKHPD[LPXPRXWZDUGEXOJLQJRILQ

RFFXUULQJDW(/IW



9LVXDODQG'HODPLQDWLRQ6XUYH\\

6*+YLVXDOO\\REVHUYHGWKHHQWLUHIDFHRIWKHQRUWKZDOOZKHUHDFFHVVLEOH 3KRWR 6*+QRWHG

IUHTXHQWSURPLQHQWKRUL]RQWDOFUDFNVIURP(/IWWR(/IWDFURVVWKHHQWLUHQRUWKZDOO

7KHFUDFNLQJFRQGLWLRQLVPRVWREYLRXVRQWKHHDVWVLGHRIWKHZDOODGMDFHQWWRWKH&(%ZKHUHLW

LVDERYHWKHHTXLSPHQWWKLVSRUWLRQRIWKHZDOOZDVLQDFFHVVLEOHIRUFORVHREVHUYDWLRQDWWKH

WLPHRILQVSHFWLRQ6*+GLGQRWQRWHDQ\\DSSDUHQWVLJQLILFDQWFKDQJHVLQWKHFUDFNLQJFRQGLWLRQ

DVFRPSDUHGWR6*+¶VSULRUVXUYH\\LQ1RYHPEHU>@



6*+SHUIRUPHGDGHODPLQDWLRQVXUYH\\RIWKHDFFHVVLEOHQRUWKIDFHRIWKHQRUWKZDOOIURPWKH

IORRUVODEDW(/IWDQGIURPWKHVWDLUVDWWKHPLGGOHDQGWRSODQGLQJV6*+SHUIRUPHGWKH

GHODPLQDWLRQVXUYH\\E\\VRXQGLQJWKHZDOOZLWKDPDVRQ¶VKDPPHUDQGQRWHGKROORZVRXQGLQJ

DUHDVDWWKHIROORZLQJORFDWLRQV



x

7ZRORFDOL]HGDUHDVDWWKHERWWRPFRUQHUVRIWKH&(9$GRRUDSSUR[LPDWHO\\VTIWDQG

 VT IW UHVSHFWLYHO\\ QH[W WR WKH VWDLU SODWIRUP JUDWLQJ DW (/ IW LQ 3KRWRV 

DQG 

x

0XOWLSOHORFDOL]HGDUHDVDORQJFUDFNVIURP(/ IWWRIWDWWKHZDOODERYHWKH

PLGGOH ODQGLQJ DUHD RI WKH VWDLUV  7KH FUDFNV DW WKH KROORZVRXQGLQJ DUHDV H[KLELW

ZLGWKVJUHDWHUWKDQLQ 3KRWRVWKURXJK 7KHSRUWLRQVRIWKHFRQFUHWHZDOO

DERYHWKHHTXLSPHQWFRXOGQRWEHVRXQGHGGXHWRDFFHVVUHVWULFWLRQV7KHFUDFNVDW

WKHLQDFFHVVLEOHORFDWLRQV SDUWLFXODUO\\RQWKHHDVWVLGHDGMDFHQWWRWKH&(% DSSHDUWR

EHZLGHUWKDQWKHFUDFNVDVVRFLDWHGZLWKWKHKROORZVRXQGLQJDUHDVDWWKHVWDLUV



6800$5<',6&866,216$1'5(&200(1'$7,216

6*+ SHUIRUPHG WKUHVKROG LQVSHFWLRQV RI WKH QRUWK ZDOO RI WKH &(9$ VWUXFWXUH LQ

6HSWHPEHUDQGIRXQGWKHIROORZLQJ



x

7KH FRQFUHWH VXUIDFH RI WKH QRUWK ZDOO EHWZHHQ (/  IW DQG (/  IW H[KLELWV

H[WHQVLYH KRUL]RQWDO FUDFNV 6*+ QRWHG QR VLJQV RI VLJQLILFDQW FKDQJHV LQ FUDFNLQJ

FRQGLWLRQDVFRPSDUHGWRWKHSULRULQVSHFWLRQLQ1RYHPEHU>@

6LWH9LVLW5HSRUW1R

RI

2FWREHU

'RFXPHQW,'1R6955

5HYLVLRQ

x 7KHUHVXOWVRIZDOOSOXPEQHVVPHDVXUHPHQWV EHWZHHQ(/IWWR(/IW LQGLFDWH DQRXWZDUGEXOJLQJRIWKHZDOOZLWKDPD[LPXPGLVSODFHPHQWRILQDW(/IW

UHODWLYHWRWKHQHDUEDVHRIWKHQRUWKZDOODW(/IW7KHPD[LPXPRXWZDUGEXOJLQJ DSSHDUVWRKDYHLQFUHDVHGIURPWKH1RYHPEHULQVSHFWLRQVZKHQLWZDVLQ

RFFXUULQJDW(/IWWRIW7KHPD[LPXPERZLQJUHPDLQVZLWKLQWKHWKUHVKROGOLPLW

LQ

x

%DVHGRQDGHODPLQDWLRQVXUYH\\XVLQJFRQYHQWLRQDOKDPPHUVRXQGLQJ ZKLFKLVOLPLWHG LQGHWHFWLRQUDQJHWRQHDUVXUIDFHVKDOORZ W\\SLFDOO\\WRLQGHHS GHODPLQDWLRQV>@ 

6*+QRWHGORFDOL]HGQHDUVXUIDFHFRQFUHWHGHODPLQDWLRQVDWWKHDFFHVVLEOHDUHDVIURP WKHVWDLUZHOOWKDWDUHSULPDULO\\DVVRFLDWHGZLWKYLVLEOHKRUL]RQWDOFUDFNV6*+FRXOGQRW SHUIRUPDGHODPLQDWLRQVXUYH\\DERYHWKHHTXLSPHQWKRZHYHUEDVHGRQWKHREVHUYHG FUDFNLQJFRQGLWLRQLWLVOLNHO\\WKDWDGGLWLRQDOQHDUVXUIDFHGHODPLQDWLRQVDUHSUHVHQWDW WKHSURPLQHQWKRUL]RQWDOFUDFNVDERYHWKHHTXLSPHQW7KHQHDUVXUIDFHGHODPLQDWLRQV PD\\IXUWKHUGHYHORSLQWRFRQFUHWHVSDOOVWKDWFRXOGEUHDNRIIIURPWKHZDOODQGIDOORQWR WKHVWDLUVDQGHTXLSPHQWEHORZ

x 6*+UHFRPPHQGVWKDWFRQFUHWHUHSDLUVRIWKHQRUWKZDOORI&(9$EHSODQQHGIRUWKH QHDUIXWXUHWRDGGUHVVQHDUVXUIDFHGHODPLQDWLRQVDQGSRWHQWLDOIXWXUHVSDOOLQJ,QWKH PHDQWLPH WHPSRUDU\\ SURWHFWLRQ RU FRQFUHWH UHVWUDLQWV FRXOG EH SURDFWLYHO\\ DQG FRQVHUYDWLYHO\\LQVWDOOHGWRSUHYHQWSRWHQWLDOFRQFUHWHVSDOOVIURPFRQWDFWLQJVHQVLWLYH SRUWLRQVRIWKHHTXLSPHQWDQGFDEOLQJ



5()(5(1&(6

>@

6LPSVRQ *XPSHUW]  +HJHU,QF Evaluation of Containment Enclosure Ventilation Area, &DOFXODWLRQ1R&$5HYLVLRQ0DUFK )3 

>@

$PHULFDQ&RQFUHWH,QVWLWXWH$&,5Guide for Conducting a Visual Inspection of Concrete In Service)DUPLQJWRQ+LOOV0,

>@

6LPSVRQ *XPSHUW]  +HJHU,QF ASR Inspections on Containment Enclosure Ventilation Area, NextEra Energy Seabrook Facility, Seabrook, NH, 6*+ 6LWH 9LVLW 5HSRUW1R6955HYLVLRQ0DUFK )3 

>@

<HKDL $EXGD\\\\HK $EGHO4DGHU DQG =DOW *35 &KDLQ 'UDJ DQG *URXQG 7UXWK

&RUUHODWLRQ RI %ULGJH 'HFN $VVHVVPHQW 'DWD 75%  $QQXDO 0HHWLQJ

7UDQVSRUWDWLRQ5HVHDUFK%RDUG:DVKLQJWRQ'&

6LWH9LVLW5HSRUW1R

RI

2FWREHU

'RFXPHQW,'1R6955



5HYLVLRQ

















3KRWR



6*+PHDVXULQJWKH

SOXPEQHVVRIWKH

ZDOOZLWKDSOXPE

EREDWWDFKHGWRD

VWULQJ



3KRWR



9LHZGRZQWKH

SOXPEEREVWULQJ

\\HOORZDUURZ 

H[WHQGLQJIURP

(/IWWRIW

6LWH9LVLW5HSRUW1R

RI

2FWREHU

'RFXPHQW,'1R6955



5HYLVLRQ

















3KRWR



2YHUDOOYLHZRIWKHQRUWKIDFH

RIWKHQRUWKZDOO



3KRWR



&RQFUHWHGHODPLQDWLRQDWWKH

VWDLUSODWIRUP (/IW WR

WKHOHIWRIWKHGRRUDVVKRZQ

E\\WKHEOXHKDWFKLQJ



6LWH9LVLW5HSRUW1R

RI

2FWREHU

'RFXPHQW,'1R6955



5HYLVLRQ















3KRWR



&RQFUHWHGHODPLQDWLRQDWWKH

VWDLUSODWIRUP (/IW WR

WKHULJKWVLGHRIWKHGRRUDV

LQGLFDWHGE\\WKH\\HOORZ

DUURZ



3KRWR



6*+VXUYH\\HGWKHSRUWLRQRI

WKHZDOOEHWZHHQ(/IW

DQGIWIURPWKHPLGGOH

VWDLUODQGLQJ



6LWH9LVLW5HSRUW1R

RI

2FWREHU

'RFXPHQW,'1R6955



5HYLVLRQ













3KRWR



&RQFUHWHGHODPLQDWLRQDORQJ

FUDFNVRQWKHZDOOVKRZQLQ

EOXHKDWFKHGDUHD



3KRWR



&RQFUHWHGHODPLQDWLRQDORQJ

FUDFNVRQWKHZDOOVKRZQLQ

EOXHKDWFKHGDUHD



6LWH9LVLW5HSRUW1R

RI

2FWREHU

'RFXPHQW,'1R6955



5HYLVLRQ















)LJXUH3OXPEQHVVSURILOHRIWKHQRUWKIDFHRIWKH1RUWK:DOORI&(9$IURP(/IWWR(/IW



1RUWK:DOO)DFH 7RSRI0HFK3HQ6ODE

&(9$)ORRU6ODE

0HDVXUHPHQW  +/-

DWHDVWVLGHRIWKH

VWDLUZHOO

0HDVXUHPHQW  +/-

DWZHVWVLGHRIWKH

VWDLUZHOO