ML18003A997
| ML18003A997 | |
| Person / Time | |
|---|---|
| Site: | Clinch River |
| Issue date: | 12/15/2017 |
| From: | James Shea Tennessee Valley Authority |
| To: | Office of New Reactors |
| Fetter A | |
| References | |
| TVACLINCHRIVERESP, TVACLINCHRIVERESP.SUBMISSION.4, CRN.P.PART08, CRN.P.PART08.1 | |
| Download: ML18003A997 (47) | |
Text
APPENDIX E-Observation Wells and Field Permeability Testing No Change for Rev. 4 E.1 - Observation Well Installation Logs E.2 -Well Development Data E.3-Packer Test Data E.4-Slug Test Data Clinch River Data Report Rev. 4 CRP-1112.16 Page E1 of 1 a me
APPENDIX E.1 -Observation Well Installation Logs Clinch River Data Report Rev. 4 CRP-1112.16 Page E.1-1 of 46 No Change for Rev. 4 a me
MEMORANDUM DATE:
April 29, 2014 FROM:
William B. Deobald
SUBJECT:
Review of Well Logs, Data Report Rev 1 for AMEC Project 6468-13-1072, Clinch River SMR Project TO:
Project Record Control File COPY TO:
Steve Criscenzo This memo serves as confirmation that I have reviewed the well logs contained in AppendixE of the Clinch River SMR DATA Report Rev 1 dated Apri129, 2014. I give my approval for my typed initials (WBD) to be affixed to the logs to indicate my review and approval of these logs.
Site Manager AMEC Environment & Infrastructure, Inc.
4021 Stirrup Creek Drive, Suite 100 Durham, North Carolina 27703 Tel (919) 381-9900 Fax (919) 381-9901 www.amec.com Clinch River Data Report Rev. 4 CRP-1112.16 Page E.1-2 of 46
Observation Well Data Sheet Prepared by/Date: MBL 4/29/14 Checked by/Date: WBD 4/29/14 Project Name:
CLINCH RIVER SMR PROJECT (AMEC 6468-13-1072)
County:
ROANE, TN Observation Weill.D.:
OW-101 U Date of Observation Well Installation:
7/31/13 Date of Well Development:
8/20/13 Observation Well Northing:
570235.5 US ft Easting:
2448339.3 US ft Observation Well Driller Observation Well Location:
Clinch River SMR Site Name:
B. Woods (M&W)
NOTES:
License No.:
TN #658 Observation well installed in accordance with ASTM D 5092-04(201 O)e1.
Northing and Easting =Tennessee State Plane Coordinates, NAD83, US Survey Feet.
Elevations = North American Vertical Datum of 1988 (NAVD88), Feet.
Depths/elevations referenced to surveyed ground surface.
Static water elevation referenced to mark on top of well casing.
Observation well drilled using air rotary techniques.
Steel centralizers installed approximately 5.0 and 25.0 feet below ground surface.
PVC well screen machine-slotted by manufacturer.
Well development activities conducted between 8/7/13 through 8/20/13.
Seep holes drilled into protective steel stick up cover upon completion of well installation.
AMEC Inspector Supervising Well Installation: _M_._L_e_a_r ____________________ _
Static Water Level Elevation (NAVD88) collected December 9, 2013: _7_9_8_.4_2 ____________ _
Type of Locking Device:
Masterlock-Key A953 Type of Casing Protection: ___
S_t_e_e_l S_t_ic_k_U~p __ _
Concrete Surface Pad Dimensions:
2'x2'x0.5' DIAGRAM NOT TO SCALE ctive Steel Cover
- ~
4(
Top of Casing Elevation:
803.72 Prote Top of Concre te Elevation: 800.73 ~
Ground Surface ~
c---
c---~
~-- Ground Surface Elevation: 800.58
\\
v ng Seal I Grout Sea Casi M aterial: Cement-Bentonite Grout 4(
Bottom of Grout Seal I Top of Bentonite Seal Bent onite Seal r Pack Filte M aterial:
DSI NO. 2 Well Sand Well s
s T
s Screen creen Top Depth:
creen Top Elevation:
ype of Well Screen:
creen Opening Size:
26.0 774.6 PVC 0.020" Screen Bottom Depth:
46.0 Screen Bottom Elevation:
754.6 Clinch River Data Report Rev. 4 CRP-1112.16 Page E.1-3 of 46 Depth:
15.0 Elevation:
785.6 4(
Filter Pack Top Depth:
21.4 Elevation:
779.2 Well Casing Type:
PVC Size (diameter):
2" Schedule or Thickness:
SCH 40 46.5 J
Bottom Sump/Cap Depth:
50.0 Drilled Depth of Borehole:
14-(f--------l*~ Bore Hole Diameter:----'------
I I
6-8" AMEC Environment & Infrastructure, Inc.
Observation Well Data Sheet Prepared by/Date: MBL 4/29/14 Checked by/Date: WBD 4/29/14 Project Name:
CLINCH RIVER SMR PROJECT (AMEC 6468-13-1072)
County:
ROANE, TN Observation Weiii.D.:
OW-101L Date of Observation Well Installation:
7/31/13 Date of Well Development:
8/7/13 Observation Well Northing:
570262.0 US ft Easting:
2448370.8 US ft Observation Well Driller Observation Well Location:
Clinch River SMR Site Name:
B. Woods (M&W)
NOTES:
License No.:
TN #658 Observation well installed in accordance with ASTM D 5092-04(201 O)e1.
Northing and Easting =Tennessee State Plane Coordinates, NAD83, US Survey Feet.
Elevations = North American Vertical Datum of 1988 (NAVD88), Feet.
Depths/elevations referenced to surveyed ground surface.
Static water elevation referenced to mark on top of well casing.
Observation well drilled using air rotary techniques.
Steel centralizers installed above well screen and at approximately 50-ft intervals to ground surface.
PVC well screen machine-slotted by manufacturer.
Well development activities conducted between 8/6/2013 through 8/7/2013.
Seep holes drilled into protective steel stick up cover upon completion of well installation.
AMEC Inspector Supervising Well Installation: _M_._L_e_a_r ____________________ _
Static Water Level Elevation (NAVD88) collected December 9, 2013: _7_7_3_.4_7 ____________ _
Type of Locking Device:
Masterlock-Key A953 Type of Casing Protection: ___
S_t_e_e_l S_t_ic_k_U~p __ _
Concrete Surface Pad Dimensions:
2'x2'x0.5' DIAGRAM NOT TO SCALE ctive Steel Cover
- ~
4(
Top of Casing Elevation:
803.48 Prote Top of Concre te Elevation: 800.81 ~
Ground Surface ~
c---
c---~
~-- Ground Surface Elevation: 800.66
\\
v ng Seal I Grout Sea Casi M aterial: Cement-Bentonite Grout 4(
Bottom of Grout Seal I Top of Bentonite Seal Bent onite Seal r Pack Filte M aterial:
DSI NO. 2 Well Sand Well s
s T
s Screen creen Top Depth:
creen Top Elevation:
ype of Well Screen:
creen Opening Size:
138.0 662.7 PVC 0.020" Screen Bottom Depth:
158.0 Screen Bottom Elevation:
642.7 Clinch River Data Report Rev. 4 CRP-1112.16 Page E.1-4 of 46 Depth:
126.6 Elevation:
674.1 4(
Filter Pack Top Depth:
133.6 Elevation:
667.1 Well Casing Type:
PVC Size (diameter):
2" Schedule or Thickness:
SCH 80 158.5 J
Bottom Sump/Cap Depth:
161.0 Drilled Depth of Borehole:
14-(f--------l*~ Bore Hole Diameter:----'------
I I
6-8" AMEC Environment & Infrastructure, Inc.
Observation Well Data Sheet Prepared by/Date: MBL 4/29/14 Checked by/Date: WBD 4/29/14 Project Name:
CLINCH RIVER SMR PROJECT (AMEC 6468-13-1072)
County:
ROANE, TN Observation Weill.D.:
OW-101 D Date of Observation Well Installation:
7/30/13 Date of Well Development:
9/4/13 Observation Well Northing:
570274.9 US ft Easting:
2448386.4 US ft Observation Well Driller Observation Well Location:
Clinch River SMR Site Name:
B. Woods (M&W)
NOTES:
License No.:
TN #658 Observation well installed in accordance with ASTM D 5092-04(201 O)e1.
Northing and Easting =Tennessee State Plane Coordinates, NAD83, US Survey Feet.
Elevations = North American Vertical Datum of 1988 (NAVD88), Feet.
Depths/elevations referenced to surveyed ground surface.
Static water elevation referenced to mark on top of well casing.
Observation well drilled using air rotary techniques.
Steel centralizers installed above well screen and at approximately 50-ft intervals to ground surface.
PVC well screen machine-slotted by manufacturer.
Well development activities conducted between 9/2/2013 through 9/4/13.
Seep holes drilled into protective steel stick up cover upon completion of well installation.
Well borehole over-drilled per SDDR CRP-19.
Over-drilled portion of borehole filled with DSI No. 2 Well Sand prior to well installation per SDDR CRP-19.
AMEC Inspector Supervising Well Installation: _M_._L_e_a_r ____________________ _
Static Water Level Elevation (NAVD88) collected December 9, 2013: _7_4_9_.3_9 ____________ _
Type of Locking Device:
Masterlock-Key A953 Type of Casing Protection:
Steel Stick Up Concrete Surface Pad Dimensions:
2'x2'x0.5' DIAGRAM NOT TO SCALE ctive Steel Cover
- ~
4(
Top of Casing Elevation:
803.57 Prote Top of Concre te Elevation: 800.82 ~
Ground Surface ~
c---
c---~
~-- Ground Surface Elevation: 800.65
\\
v ng Seal I Grout Sea Casi M aterial: Cement-Bentonite Grout 4(
Bottom of Grout Seal I Top of Bentonite Seal Bent onite Seal r Pack Filte M aterial:
DSI NO. 2 Well Sand Well s
s T
s Screen creen Top Depth:
creen Top Elevation:
ype of Well Screen:
creen Opening Size:
230.5 570.2 PVC 0.020" Screen Bottom Depth:
250.5 Screen Bottom Elevation:
550.2 Clinch River Data Report Rev. 4 CRP-1112.16 Page E.1-5 of 46 Depth:
219.2 Elevation:
581.5 4(
Filter Pack Top Depth:
225.8 Elevation:
574.9 Well Casing Type:
PVC Size (diameter):
2" Schedule or Thickness:
SCH 80 251.0 J
Bottom Sump/Cap Depth:
261.5 Drilled Depth of Borehole:
14-(f--------l*~ Bore Hole Diameter:----'------
I I
6-8" AMEC Environment & Infrastructure, Inc.
Observation Well Data Sheet Prepared by/Date: MBL 4/29/14 Checked by/Date: WBD 4/29/14 Project Name:
CLINCH RIVER SMR PROJECT (AMEC 6468-13-1072)
County:
ROANE, TN Observation Weiii.D.:
OW-202U Date of Observation Well Installation:
8/21/13 Date of Well Development:
9/16/13 Observation Well Northing:
570946.0 US ft Easting:
2448081.1 US ft Observation Well Driller Observation Well Location:
Clinch River SMR Site Name:
B. Woods (M&W)
NOTES:
License No.:
TN #658 Observation well installed in accordance with ASTM D 5092-04(201 O)e1.
Northing and Easting =Tennessee State Plane Coordinates, NAD83, US Survey Feet.
Elevations = North American Vertical Datum of 1988 (NAVD88), Feet.
Depths/elevations referenced to surveyed ground surface.
Static water elevation referenced to mark on top of well casing.
Observation well drilled using air rotary techniques.
Steel centralizer installed approximately 15.0 feet below ground surface.
PVC well screen machine-slotted by manufacturer.
Well development activities conducted between 9/12/2013 through 9/16/2013. Well very slow to recharge.
Seep holes drilled into protective steel stick up cover upon completion of well installation.
AMEC Inspector Supervising Well Installation: _J_. _G_o_d_d_a_rd ___________________ _
Static Water Level Elevation (NAVD88) collected December 9, 2013: _8_0_0_.1_5 ____________ _
Type of Locking Device:
Masterlock-Key A953 Type of Casing Protection: ___
S_t_e_e_l S_t_ic_k_U~p __ _
Concrete Surface Pad Dimensions:
2'x2'x0.5' DIAGRAM NOT TO SCALE ctive Steel Cover
- ~
4(
Top of Casing Elevation:
815.38 Prote Top of Concre te Elevation: 812.11 ~
Ground Surface ~
c---
c---~
~-- Ground Surface Elevation: 811.83
\\
v ng Seal I Grout Sea Casi M aterial: Cement-Bentonite Grout 4(
Bottom of Grout Seal I Top of Bentonite Seal Bent onite Seal r Pack Filte M aterial:
DSI NO. 2 Well Sand Well s
s T
s Screen creen Top Depth:
creen Top Elevation:
ype of Well Screen:
creen Opening Size:
15.7 796.1 PVC 0.020" Screen Bottom Depth:
35.7 Screen Bottom Elevation:
776.1 Clinch River Data Report Rev. 4 CRP-1112.16 Page E.1-6 of 46 Depth:
4.3 Elevation
807.5 4(
Filter Pack Top Depth:
11.1 Elevation:
800.7 Well Casing Type:
PVC Size (diameter):
2" Schedule or Thickness:
SCH 40 36.2 J
Bottom Sump/Cap Depth:
39.0 Drilled Depth of Borehole:
14-(f--------l*~ Bore Hole Diameter:----'------
I I
6-8" AMEC Environment & Infrastructure, Inc.
Observation Well Data Sheet Prepared by/Date: MBL 4/29/14 Checked by/Date: WBD 4/29/14 Project Name:
CLINCH RIVER SMR PROJECT (AMEC 6468-13-1072)
County:
ROANE, TN Observation Weiii.D.:
OW-202L Date of Observation Well Installation:
8/20/13 Date of Well Development:
9/15/13 Observation Well Northing:
570934.2 US ft Easting:
2448064.9 US ft Observation Well Driller Observation Well Location:
Clinch River SMR Site Name:
B. Woods (M&W)
NOTES:
License No.:
TN #658 Observation well installed in accordance with ASTM D 5092-04(201 O)e1.
Northing and Easting =Tennessee State Plane Coordinates, NAD83, US Survey Feet.
Elevations = North American Vertical Datum of 1988 (NAVD88), Feet.
Depths/elevations referenced to surveyed ground surface.
Static water elevation referenced to mark on top of well casing.
Observation well drilled using air rotary techniques.
Steel centralizers installed above well screen and at approximately 50-ft intervals to ground surface.
PVC well screen machine-slotted by manufacturer.
Well development activities conducted between 9/14/2013 through 9/15/2013.
Seep holes drilled into protective steel stick up cover upon completion of well installation.
AMEC Inspector Supervising Well Installation: _J_. _G_o_d_d_a_rd ___________________ _
Static Water Level Elevation (NAVD88) collected December 9, 2013: _7_7_8_.2_7 ____________ _
Type of Locking Device:
Masterlock-Key A953 Type of Casing Protection: ___
S_t_e_e_l S_t_ic_k_U~p __ _
Concrete Surface Pad Dimensions:
2'x2'x0.5' DIAGRAM NOT TO SCALE ctive Steel Cover
- ~
4(
Top of Casing Elevation:
815.05 Prote Top of Concre te Elevation: 812.23 ~
Ground Surface ~
c---
c---~
~-- Ground Surface Elevation: 811.97
\\
v ng Seal I Grout Sea Casi M aterial: Cement-Bentonite Grout 4(
Bottom of Grout Seal I Top of Bentonite Seal Bent onite Seal r Pack Filte M aterial:
DSI NO. 2 Well Sand Well s
s T
s Screen creen Top Depth:
creen Top Elevation:
ype of Well Screen:
creen Opening Size:
150.5 661.5 PVC 0.020" Screen Bottom Depth:
170.5 Screen Bottom Elevation:
641.5 Clinch River Data Report Rev. 4 CRP-1112.16 Page E.1-7 of 46 Depth:
141.1 Elevation:
670.9 4(
Filter Pack Top Depth:
147.0 Elevation:
665.0 Well Casing Type:
PVC Size (diameter):
2" Schedule or Thickness:
SCH 80 171.0 J
Bottom Sump/Cap Depth:
173.0 Drilled Depth of Borehole:
14-(f--------l*~ Bore Hole Diameter:----'------
I I
6-8" AMEC Environment & Infrastructure, Inc.
Observation Well Data Sheet Prepared by/Date: MBL 4/29/14 Checked by/Date: WBD 4/29/14 Project Name:
CLINCH RIVER SMR PROJECT (AMEC 6468-13-1072)
County:
ROANE, TN Observation Weiii.D.:
OW-202D Date of Observation Well Installation:
8/19/13 Date of Well Development:
9/16/13 Observation Well Northing:
570909.7 US ft Easting:
2448033.7 US ft Observation Well Driller Observation Well Location:
Clinch River SMR Site Name:
B. Woods (M&W)
NOTES:
License No.:
TN #658 Observation well installed in accordance with ASTM D 5092-04(201 O)e1.
Northing and Easting =Tennessee State Plane Coordinates, NAD83, US Survey Feet.
Elevations = North American Vertical Datum of 1988 (NAVD88), Feet.
Depths/elevations referenced to surveyed ground surface.
Static water elevation referenced to mark on top of well casing.
Observation well drilled using air rotary techniques.
Steel centralizers installed above well screen and at approximately 50-ft intervals to ground surface.
PVC well screen machine-slotted by manufacturer.
Well development activities conducted between 9/14/2013 through 9/16/2013.
Seep holes drilled into protective steel stick up cover upon completion of well installation.
AMEC Inspector Supervising Well Installation: _J_. _G_o_d_d_a_rd ___________________ _
Static Water Level Elevation (NAVD88) collected December 9, 2013: _7_6_3_.6_4 ____________ _
Type of Locking Device:
Masterlock-Key A953 Type of Casing Protection: ___
S_t_e_e_l S_t_ic_k_U~p __ _
Concrete Surface Pad Dimensions:
2'x2'x0.5' DIAGRAM NOT TO SCALE ctive Steel Cover
- ~
4(
Top of Casing Elevation:
815.00 Prote Top of Concre te Elevation: 812.21 ~
Ground Surface ~
c---
c---~
~-- Ground Surface Elevation: 812.10
\\
v ng Seal I Grout Sea Casi M aterial: Cement-Bentonite Grout 4(
Bottom of Grout Seal I Top of Bentonite Seal Bent onite Seal r Pack Filte M aterial:
DSI NO. 2 Well Sand Well s
s T
s Screen creen Top Depth:
creen Top Elevation:
ype of Well Screen:
creen Opening Size:
276.4 535.7 PVC 0.020" Screen Bottom Depth:
296.4 Screen Bottom Elevation:
515.7 Clinch River Data Report Rev. 4 CRP-1112.16 Page E.1-8 of 46 Depth:
260.0 Elevation:
552.1 4(
Filter Pack Top Depth:
273.0 Elevation:
539.1 Well Casing Type:
PVC Size (diameter):
2" Schedule or Thickness:
SCH 80 296.9 J
Bottom Sump/Cap Depth:
303.0 Drilled Depth of Borehole:
14-(f--------l*~ Bore Hole Diameter:----'------
I I
6-8" AMEC Environment & Infrastructure, Inc.
Observation Well Data Sheet Prepared by/Date: MBL 4/29/14 Checked by/Date: WBD 4/29/14 Project Name:
CLINCH RIVER SMR PROJECT (AMEC 6468-13-1072)
County:
ROANE, TN Observation Weill.D.:
OW-401 U Date of Observation Well Installation:
8/4/13 Date of Well Development:
9/18/13 Observation Well Northing:
571967.9 US ft Easting:
2447619.9 US ft Observation Well Driller Observation Well Location:
Clinch River SMR Site Name:
N. Dempsey (TSD)
NOTES:
License No.:
TN #936 Observation well installed in accordance with ASTM D 5092-04(201 O)e1.
Northing and Easting =Tennessee State Plane Coordinates, NAD83, US Survey Feet.
Elevations = North American Vertical Datum of 1988 (NAVD88), Feet.
Depths/elevations referenced to surveyed ground surface.
Static water elevation referenced to mark on top of well casing.
Observation well drilled using air rotary techniques.
Steel centralizer installed approximately 12.0 feet below ground surface.
PVC well screen machine-slotted by manufacturer.
Well development activities conducted between 9/12/2013 through 9/18/2013.
Seep holes drilled into protective steel stick up cover upon completion of well installation.
AMEC Inspector Supervising Well Installation: _J_. _H_e_n_s_be_r_r~y __________________ _
Static Water Level Elevation (NAVD88) collected December 9, 2013: _8_1_3_.1_4 ____________ _
Type of Locking Device:
Masterlock-Key A953 Type of Casing Protection: ___
S_t_e_e_l S_t_ic_k_U~p __ _
Concrete Surface Pad Dimensions:
2'x2'x0.5' DIAGRAM NOT TO SCALE ctive Steel Cover
- ~
4(
Top of Casing Elevation:
820.48 Prote Top of Concre te Elevation: 817.55 ~
Ground Surface ~
c---
c---~
~-- Ground Surface Elevation: 817.39
\\
v ng Seal I Grout Sea Casi M aterial: Cement-Bentonite Grout 4(
Bottom of Grout Seal I Top of Bentonite Seal Bent onite Seal r Pack Filte M aterial:
DSI NO. 2 Well Sand Well s
s T
s Screen creen Top Depth:
creen Top Elevation:
ype of Well Screen:
creen Opening Size:
15.2 802.2 PVC 0.020" Screen Bottom Depth:
35.2 Screen Bottom Elevation:
782.2 Clinch River Data Report Rev. 4 CRP-1112.16 Page E.1-9 of 46 Depth:
5.2 Elevation
812.2 4(
Filter Pack Top Depth:
10.5 Elevation:
806.9 Well Casing Type:
PVC Size (diameter):
2" Schedule or Thickness:
SCH 40 35.7 J
Bottom Sump/Cap Depth:
37.5 Drilled Depth of Borehole:
14-(f--------l*~ Bore Hole Diameter:----'------
I I
6-8" AMEC Environment & Infrastructure, Inc.
Observation Well Data Sheet Prepared by/Date: MBL 4/29/14 Checked by/Date: WBD 4/29/14 Project Name:
CLINCH RIVER SMR PROJECT (AMEC 6468-13-1072)
County:
ROANE, TN Observation Weiii.D.:
OW-401L Date of Observation Well Installation:
8/3/13 Date of Well Development:
8/13/13 Observation Well Northing:
571973.8 US ft Easting:
2447628.0 US ft Observation Well Driller Observation Well Location:
Clinch River SMR Site Name:
N. Dempsey (TSD)
NOTES:
License No.:
TN #936 Observation well installed in accordance with ASTM D 5092-04(201 O)e1.
Northing and Easting =Tennessee State Plane Coordinates, NAD83, US Survey Feet.
Elevations = North American Vertical Datum of 1988 (NAVD88), Feet.
Depths/elevations referenced to surveyed ground surface.
Static water elevation referenced to mark on top of well casing.
Observation well drilled using air rotary techniques.
Steel centralizers installed above well screen and at approximately 50-ft intervals to ground surface.
PVC well screen machine-slotted by manufacturer.
Well development activities conducted between 8/7/2013 through 8/13/2013.
Seep holes drilled into protective steel stick up cover upon completion of well installation.
AMEC Inspector Supervising Well Installation: _J_. _H_e_n_s_be_r_r~y __________________ _
Static Water Level Elevation (NAVD88) collected December 9, 2013: _7_9_1_.7_5 ____________ _
Type of Locking Device:
Masterlock-Key A953 Type of Casing Protection: ___
S_t_e_e_l S_t_ic_k_U~p __ _
Concrete Surface Pad Dimensions:
2'x2'x0.5' DIAGRAM NOT TO SCALE ctive Steel Cover
- ~
4(
Top of Casing Elevation:
820.57 Prote Top of Concre te Elevation: 817.4 7 ~
Ground Surface ~
c---
c---~
~-- Ground Surface Elevation: 817.22
\\
v ng Seal I Grout Sea Casi M aterial: Cement-Bentonite Grout 4(
Bottom of Grout Seal I Top of Bentonite Seal Bent onite Seal r Pack Filte M aterial:
DSI NO. 2 Well Sand Well s
s T
s Screen creen Top Depth:
creen Top Elevation:
ype of Well Screen:
creen Opening Size:
135.2 682.0 PVC 0.020" Screen Bottom Depth:
155.2 Screen Bottom Elevation:
662.0 Clinch River Data Report Rev. 4 CRP-1112.16 Page E.1-10 of46 Depth:
126.7 Elevation:
690.5 4(
Filter Pack Top Depth:
130.8 Elevation:
686.4 Well Casing Type:
PVC Size (diameter):
2" Schedule or Thickness:
SCH 80 155.7 J
Bottom Sump/Cap Depth:
159.3 Drilled Depth of Borehole:
14-(f--------l*~ Bore Hole Diameter:----'------
I I
6-8" AMEC Environment & Infrastructure, Inc.
Observation Well Data Sheet Prepared by/Date: MBL 4/29/14 Checked by/Date: WBD 4/29/14 Project Name:
CLINCH RIVER SMR PROJECT (AMEC 6468-13-1072)
County:
ROANE, TN Observation Weill.D.:
OW-401 D Date of Observation Well Installation:
8/2/13 Date of Well Development:
8/15/13 Observation Well Northing:
571941.2 US ft Easting:
2447589.7 US ft Observation Well Driller Observation Well Location:
Clinch River SMR Site Name:
N. Dempsey (TSD)
NOTES:
License No.:
TN #936 Observation well installed in accordance with ASTM D 5092-04(201 O)e1.
Northing and Easting =Tennessee State Plane Coordinates, NAD83, US Survey Feet.
Elevations = North American Vertical Datum of 1988 (NAVD88), Feet.
Depths/elevations referenced to surveyed ground surface.
Static water elevation referenced to mark on top of well casing.
Observation well drilled using air rotary techniques.
Steel centralizers installed above well screen and at approximately 50-ft intervals to ground surface.
PVC well screen machine-slotted by manufacturer.
Well development activities conducted between 8/14/2013 through 8/15/2013.
Seep holes drilled into protective steel stick up cover upon completion of well installation.
AMEC Inspector Supervising Well Installation: _J_. _H_e_n_s_be_r_r~y __________________ _
Static Water Level Elevation (NAVD88) collected December 9, 2013: _7_8_6_.8_7 ____________ _
Type of Locking Device:
Masterlock-Key A953 Type of Casing Protection: ___
S_t_e_e_l S_t_ic_k_U~p __ _
Concrete Surface Pad Dimensions:
2'x2'x0.5' DIAGRAM NOT TO SCALE ctive Steel Cover
- ~
4(
Top of Casing Elevation:
821.28 Prote Top of Concre te Elevation: 818.41 ~
Ground Surface ~
c---
c---~
~-- Ground Surface Elevation: 818.17
\\
v ng Seal I Grout Sea Casi M aterial: Cement-Bentonite Grout 4(
Bottom of Grout Seal I Top of Bentonite Seal Bent onite Seal r Pack Filte M aterial:
DSI NO. 2 Well Sand Well s
s T
s Screen creen Top Depth:
creen Top Elevation:
ype of Well Screen:
creen Opening Size:
226.6 591.6 PVC 0.020" Screen Bottom Depth:
246.6 Screen Bottom Elevation:
571.6 Clinch River Data Report Rev. 4 CRP-1112.16 Page E.1-11 of46 Depth:
215.6 Elevation:
602.6 4(
Filter Pack Top Depth:
221.9 Elevation:
596.3 Well Casing Type:
PVC Size (diameter):
2" Schedule or Thickness:
SCH 80 247.1 J
Bottom Sump/Cap Depth:
251.7 Drilled Depth of Borehole:
14-(f--------l*~ Bore Hole Diameter:----'------
I I
6-8" AMEC Environment & Infrastructure, Inc.
Observation Well Data Sheet Prepared by/Date: MBL 4/29/14 Checked by/Date: WBD 4/29/14 Project Name:
CLINCH RIVER SMR PROJECT (AMEC 6468-13-1072)
County:
ROANE, TN Observation Weiii.D.:
OW-409U Date of Observation Well Installation:
8/31/13 Date of Well Development:
9/18/13 Observation Well Northing:
570557.1 US ft Easting:
2448130.3 US ft Observation Well Driller Observation Well Location:
Clinch River SMR Site Name:
B. Woods (M&W)
NOTES:
License No.:
TN #658 Observation well installed in accordance with ASTM D 5092-04(201 O)e1.
Northing and Easting =Tennessee State Plane Coordinates, NAD83, US Survey Feet.
Elevations = North American Vertical Datum of 1988 (NAVD88), Feet.
Depths/elevations referenced to surveyed ground surface.
Static water elevation referenced to mark on top of well casing.
Observation well drilled using air rotary techniques.
Steel centralizers installed approximately 14.0 and 54.0 feet below ground surface.
PVC well screen machine-slotted by manufacturer.
Well development activities conducted between 9/12/2013 through 9/18/2013.
Seep holes drilled into protective steel stick up cover upon completion of well installation.
AMEC Inspector Supervising Well Installation: _K_._L_Io~d ____________________ _
Static Water Level Elevation (NAVD88) collected December 9, 2013: _7_62_.5_6 ____________ _
Type of Locking Device:
Masterlock-Key A953 Type of Casing Protection: ___
S_t_e_e_l S_t_ic_k_U~p __ _
Concrete Surface Pad Dimensions:
2'x2'x0.5' DIAGRAM NOT TO SCALE ctive Steel Cover
- ~
4(
Top of Casing Elevation:
809.70 Prote Top of Concre te Elevation: 807.12 ~
Ground Surface ~
c---
c---~
~-- Ground Surface Elevation: 806.91
\\
v ng Seal I Grout Sea Casi M aterial: Cement-Bentonite Grout 4(
Bottom of Grout Seal I Top of Bentonite Seal Bent onite Seal r Pack Filte M aterial:
DSI NO. 2 Well Sand Well s
s T
s Screen creen Top Depth:
creen Top Elevation:
ype of Well Screen:
creen Opening Size:
54.9 752.0 PVC 0.020" Screen Bottom Depth:
74.9 Screen Bottom Elevation:
732.0 Clinch River Data Report Rev. 4 CRP-1112.16 Page E.1-12 of46 Depth:
44.4 Elevation:
762.5 4(
Filter Pack Top Depth:
52.4 Elevation:
754.5 Well Casing Type:
PVC Size (diameter):
2" Schedule or Thickness:
SCH 40 75.4 J
Bottom Sump/Cap Depth:
78.0 Drilled Depth of Borehole:
14-(f--------l*~ Bore Hole Diameter:----'------
I I
6-8" AMEC Environment & Infrastructure, Inc.
Observation Well Data Sheet Prepared by/Date: MBL 4/29/14 Checked by/Date: WBD 4/29/14 Project Name:
CLINCH RIVER SMR PROJECT (AMEC 6468-13-1072)
County:
ROANE, TN Observation Weiii.D.:
OW-409L Date of Observation Well Installation:
8/30/13 Date of Well Development:
9/15/13 Observation Well Northing:
570570.8 US ft Easting:
2448143.3 US ft Observation Well Driller Observation Well Location:
Clinch River SMR Site Name:
B. Woods (M&W)
NOTES:
License No.:
TN #658 Observation well installed in accordance with ASTM D 5092-04(201 O)e1.
Northing and Easting =Tennessee State Plane Coordinates, NAD83, US Survey Feet.
Elevations = North American Vertical Datum of 1988 (NAVD88), Feet.
Depths/elevations referenced to surveyed ground surface.
Static water elevation referenced to mark on top of well casing.
Observation well drilled using air rotary techniques.
Steel centralizers installed approximately 4 7.0 and 87.0 feet below ground surface.
PVC well screen machine-slotted by manufacturer.
Well development activities conducted between 9/12/2103 through 9/15/2013.
Seep holes drilled into protective steel stick up cover upon completion of well installation.
AMEC Inspector Supervising Well Installation: _K_._L_Io~d ____________________ _
Static Water Level Elevation (NAVD88) collected December 9, 2013: _7_7_9_.2_2 ____________ _
Type of Locking Device:
Masterlock-Key A953 Type of Casing Protection: ___
S_t_e_e_l S_t_ic_k_U~p __ _
Concrete Surface Pad Dimensions:
2'x2'x0.5' DIAGRAM NOT TO SCALE ctive Steel Cover
- ~
4(
Top of Casing Elevation:
809.51 Prote Top of Concre te Elevation: 806.82 ~
Ground Surface ~
c---
c---~
~-- Ground Surface Elevation: 806.67
\\
v ng Seal I Grout Sea Casi M aterial: Cement-Bentonite Grout 4(
Bottom of Grout Seal I Top of Bentonite Seal Bent onite Seal r Pack Filte M aterial:
DSI NO. 2 Well Sand Well s
s T
s Screen creen Top Depth:
creen Top Elevation:
ype of Well Screen:
creen Opening Size:
89.1 717.6 PVC 0.020" Screen Bottom Depth:
109.1 Screen Bottom Elevation:
697.6 Clinch River Data Report Rev. 4 CRP-1112.16 Page E.1-13 of46 Depth:
82.7 Elevation:
724.0 4(
Filter Pack Top Depth:
86.6 Elevation:
720.1 Well Casing Type:
PVC Size (diameter):
2" Schedule or Thickness:
SCH 40 109.6 J
Bottom Sump/Cap Depth:
112.0 Drilled Depth of Borehole:
14-(f--------l*~ Bore Hole Diameter:----'------
I I
6-8" AMEC Environment & Infrastructure, Inc.
Observation Well Data Sheet Prepared by/Date: MBL 4/29/14 Checked by/Date: WBD 4/29/14 Project Name:
CLINCH RIVER SMR PROJECT (AMEC 6468-13-1072)
County:
ROANE, TN Observation Weiii.D.:
OW-415U Date of Observation Well Installation:
7/31/13 Date of Well Development:
8/16/13 Observation Well Northing:
569590.2 US ft Easting:
2448180.2 US ft Observation Well Driller Observation Well Location:
Clinch River SMR Site Name:
N. Dempsey (TSD)
NOTES:
License No.:
TN #936 Observation well installed in accordance with ASTM D 5092-04(201 O)e1.
Northing and Easting =Tennessee State Plane Coordinates, NAD83, US Survey Feet.
Elevations = North American Vertical Datum of 1988 (NAVD88), Feet.
Depths/elevations referenced to surveyed ground surface.
Static water elevation referenced to mark on top of well casing.
Observation well drilled using air rotary techniques.
Steel centralizer installed at approximately 25.0 feet below ground surface.
PVC well screen machine-slotted by manufacturer.
Well development activities conducted between 8/15/2013 through 8/16/2013.
Seep holes drilled into protective steel stick up cover upon completion of well installation.
AMEC Inspector Supervising Well Installation: _J_. _H_e_n_s_be_r_r~y __________________ _
Static Water Level Elevation (NAVD88) collected December 9, 2013: _7_72_.0_2 ____________ _
Type of Locking Device:
Masterlock-Key A953 Type of Casing Protection: ___
S_t_e_e_l S_t_ic_k_U~p __ _
Concrete Surface Pad Dimensions:
2'x2'x0.5' DIAGRAM NOT TO SCALE ctive Steel Cover
- ~
4(
Top of Casing Elevation:
787.22 Prote Top of Concre te Elevation: 784.41 ~
Ground Surface ~
c---
c---~
~-- Ground Surface Elevation: 784.13
\\
v ng Seal I Grout Sea Casi M aterial: Cement-Bentonite Grout 4(
Bottom of Grout Seal I Top of Bentonite Seal Bent onite Seal r Pack Filte M aterial:
DSI NO. 2 Well Sand Well s
s T
s Screen creen Top Depth:
creen Top Elevation:
ype of Well Screen:
creen Opening Size:
28.1 756.0 PVC 0.020" Screen Bottom Depth:
48.1 Screen Bottom Elevation:
736.0 Clinch River Data Report Rev. 4 CRP-1112.16 Page E.1-14 of 46 Depth:
19.5 Elevation:
764.6 4(
Filter Pack Top Depth:
24.1 Elevation:
760.0 Well Casing Type:
PVC Size (diameter):
2" Schedule or Thickness:
SCH 40 48.6 J
Bottom Sump/Cap Depth:
51.1 Drilled Depth of Borehole:
14-(f--------l*~ Bore Hole Diameter:----'------
I I
6-8" AMEC Environment & Infrastructure, Inc.
Observation Well Data Sheet Prepared by/Date: MBL 4/29/14 Checked by/Date: WBD 4/29/14 Project Name: ___
Cc_L_I_N__c_C_H_R_IV_E_R_S_M_R_PR_O~JE_Cc_T----'--(A_M_E_C~64_6c_8_-_13'-----1 0_7_2_L_) __
County:
ROANE, TN Observation Weiii.D.: __
O_W_-4_1_5_L __
Date of Observation Well Installation:
7/25/13 Date of Well Development:
9/11/13 Observation Well Northing:
569564.4 US ft Easting:
2448148.1 US ft Observation Well Driller Observation Well Location:
Clinch River SMR Site Name:
N. Dempsey (TSD)
NOTES:
License No.:
TN #936 Observation well installed in accordance with ASTM D 5092-04(201 O)e1.
Northing and Easting =Tennessee State Plane Coordinates, NAD83, US Survey Feet.
Elevations = North American Vertical Datum of 1988 (NAVD88), Feet.
Depths/elevations referenced to surveyed ground surface.
Static water elevation referenced to mark on top of well casing.
Observation well drilled using air rotary techniques.
Steel centralizers installed above well screen and at approximately 50-ft intervals to ground surface.
PVC well screen machine-slotted by manufacturer.
Well development activities conducted between 9/4/2013 through 9/11/2013.
Seep holes drilled into protective steel stick up cover upon completion of well installation.
AMEC Inspector Supervising Well Installation: _J_. _H_e_n_s_be_r_r~y __________________ _
Static Water Level Elevation (NAVD88) collected December 9, 2013: _7_7_1_.9_1 ____________ _
Type of Locking Device:
Masterlock-Key A953 Type of Casing Protection: ___
S_t_e_e_l S_t_ic_k_U~p __ _
Concrete Surface Pad Dimensions:
2'x2'x0.5' DIAGRAM NOT TO SCALE ctive Steel Cover
- ~
4(
Top of Casing Elevation:
786.75 Prote Top of Concre te Elevation: 783.93 ~
Ground Surface ~
c---
c---~
~-- Ground Surface Elevation: 783.65
\\
v ng Seal I Grout Sea Casi M aterial: Cement-Bentonite Grout 4(
Bottom of Grout Seal I Top of Bentonite Seal Bent onite Seal r Pack Filte M aterial:
DSI NO. 2 Well Sand Well s
s T
s Screen creen Top Depth:
creen Top Elevation:
ype of Well Screen:
creen Opening Size:
154.9 628.8 PVC 0.020" Screen Bottom Depth:
17 4.9 Screen Bottom Elevation:
608.8 Clinch River Data Report Rev. 4 CRP-1112.16 Page E.1-15 of46 Depth:
146.9 Elevation:
636.8 4(
Filter Pack Top Depth:
151.9 Elevation:
631.8 Well Casing Type:
PVC Size (diameter):
2" Schedule or Thickness:
SCH 80 175.4 J
Bottom Sump/Cap Depth:
177.4 Drilled Depth of Borehole:
14-(f--------l*~ Bore Hole Diameter:----'------
I I
6-8" AMEC Environment & Infrastructure, Inc.
Observation Well Data Sheet Prepared by/Date: MBL 4/29/14 Checked by/Date: WBD 4/29/14 Project Name: ___
Cc_L_I_N__c_C_H_R_IV_E_R_S_M_R_PR_O~JE_Cc_T----'--(A_M_E_C~64_6c_8_-_13'-----1 0_7_2_L_) __
County:
ROANE, TN Observation Weiii.D.: __
O_W_-_4_1--'--6--'--U __
Date of Observation Well Installation:
8/17/13 Date of Well Development:
9/11/13 Observation Well Northing:
569990.0 US ft Easting:
2447535.9 US ft Observation Well Driller Observation Well Location:
Clinch River SMR Site Name:
N. Dempsey (TSD)
NOTES:
License No.:
TN #936 Observation well installed in accordance with ASTM D 5092-04(201 O)e1.
Northing and Easting =Tennessee State Plane Coordinates, NAD83, US Survey Feet.
Elevations = North American Vertical Datum of 1988 (NAVD88), Feet.
Depths/elevations referenced to surveyed ground surface.
Static water elevation referenced to mark on top of well casing.
Observation well drilled using air rotary techniques.
Steel centralizers installed above well screen and at approximately 50-ft intervals to ground surface.
PVC well screen machine-slotted by manufacturer.
Well development activities conducted between 9/10/2013 through 9/11/2013.
Seep holes drilled into protective steel stick up cover upon completion of well installation.
AMEC Inspector Supervising Well Installation: _J_. _H_e_n_s_be_r_r~y __________________ _
Static Water Level Elevation (NAVD88) collected December 9, 2013: _7_4_5_.9_3 ____________ _
Type of Locking Device:
Masterlock-Key A953 Type of Casing Protection: ___
S_t_e_e_l S_t_ic_k_U~p __ _
Concrete Surface Pad Dimensions:
2'x2'x0.5' DIAGRAM NOT TO SCALE ctive Steel Cover
- ~
4(
Top of Casing Elevation:
812.82 Prote Top of Concre te Elevation: 809.82 ~
Ground Surface ~
c---
c---~
~-- Ground Surface Elevation: 809.54
\\
v ng Seal I Grout Sea Casi M aterial: Cement-Bentonite Grout 4(
Bottom of Grout Seal I Top of Bentonite Seal Bent onite Seal r Pack Filte M aterial:
DSI NO. 2 Well Sand Well s
s T
s Screen creen Top Depth:
creen Top Elevation:
ype of Well Screen:
creen Opening Size:
75.4 734.1 PVC 0.020" Screen Bottom Depth:
95.4 Screen Bottom Elevation:
714.1 Clinch River Data Report Rev. 4 CRP-1112.16 Page E.1-16 of46 Depth:
67.6 Elevation:
741.9 4(
Filter Pack Top Depth:
71.8 Elevation:
737.7 Well Casing Type:
PVC Size (diameter):
2" Schedule or Thickness:
SCH 40 95.9 J
Bottom Sump/Cap Depth:
97.5 Drilled Depth of Borehole:
14-(f--------l*~ Bore Hole Diameter:----'------
I I
6-8" AMEC Environment & Infrastructure, Inc.
Observation Well Data Sheet Prepared by/Date: MBL 4/29/14 Checked by/Date: WBD 4/29/14 Project Name: ___
Cc_L_I_N__c_C_H_R_IV_E_R_S_M_R_PR_O~JE_Cc_T----'--(A_M_E_C~64_6c_8_-_13'-----1 0_7_2_L_) __
County:
ROANE, TN Observation Weiii.D.: __
O_W_-4_1__c_6_L __
Date of Observation Well Installation:
8/16/13 Date of Well Development:
9/12/13 Observation Well Northing:
569965.2 US ft Easting:
2447504.9 US ft Observation Well Driller Observation Well Location:
Clinch River SMR Site Name:
N. Dempsey (TSD)
NOTES:
License No.:
TN #936 Observation well installed in accordance with ASTM D 5092-04(201 O)e1.
Northing and Easting =Tennessee State Plane Coordinates, NAD83, US Survey Feet.
Elevations = North American Vertical Datum of 1988 (NAVD88), Feet.
Depths/elevations referenced to surveyed ground surface.
Static water elevation referenced to mark on top of well casing.
Observation well drilled using air rotary techniques.
Steel centralizers installed above well screen and at approximately 50-ft intervals to ground surface.
PVC well screen machine-slotted by manufacturer.
Well development activities conducted between 9/11/2013 through 9/12/2013.
Seep holes drilled into protective steel stick up cover upon completion of well installation.
AMEC Inspector Supervising Well Installation: _J_. _H_e_n_s_be_r_r~y __________________ _
Static Water Level Elevation (NAVD88) collected December 9, 2013: _7_4_5_.5_6 ____________ _
Type of Locking Device:
Masterlock-Key A953 Type of Casing Protection: ___
S_t_e_e_l S_t_ic_k_U~p __ _
Concrete Surface Pad Dimensions:
2'x2'x0.5' DIAGRAM NOT TO SCALE ctive Steel Cover
- ~
4(
Top of Casing Elevation:
812.73 Prote Top of Concre te Elevation: 809.72 ~
Ground Surface ~
c---
c---~
~-- Ground Surface Elevation: 809.43
\\
v ng Seal I Grout Sea Casi M aterial: Cement-Bentonite Grout 4(
Bottom of Grout Seal I Top of Bentonite Seal Bent onite Seal r Pack Filte M aterial:
DSI NO. 2 Well Sand Well s
s T
s Screen creen Top Depth:
creen Top Elevation:
ype of Well Screen:
creen Opening Size:
110.6 698.8 PVC 0.020" Screen Bottom Depth:
130.6 Screen Bottom Elevation:
678.8 Clinch River Data Report Rev. 4 CRP-1112.16 Page E.1-17 of 46 Depth:
98.4 Elevation:
711.0 4(
Filter Pack Top Depth:
107.6 Elevation:
701.8 Well Casing Type:
PVC Size (diameter):
2" Schedule or Thickness:
SCH 40 131.1 J
Bottom Sump/Cap Depth:
133.0 Drilled Depth of Borehole:
14-(f--------l*~ Bore Hole Diameter:----'------
I I
6-8" AMEC Environment & Infrastructure, Inc.
Observation Well Data Sheet Prepared by/Date: MBL 4/29/14 Checked by/Date: WBD 4/29/14 Project Name: ___
Cc_L_I_N__c_C_H_R_IV_E_R_S_M_R_PR_O~JE_Cc_T----'--(A_M_E_C~64_6c_8_-_13'-----1 0_7_2_L_) __
County:
ROANE, TN Observation Weiii.D.: __
O_W_-_4_1_7__c_U __
Date of Observation Well Installation:
8/8/13 Date of Well Development:
8/17/13 Observation Well Northing:
569927.1 US ft Easting:
2446646.9 US ft Observation Well Driller Observation Well Location:
Clinch River SMR Site Name:
B. Woods (M&W)
NOTES:
License No.:
TN #658 Observation well installed in accordance with ASTM D 5092-04(201 O)e1.
Northing and Easting =Tennessee State Plane Coordinates, NAD83, US Survey Feet.
Elevations = North American Vertical Datum of 1988 (NAVD88), Feet.
Depths/elevations referenced to surveyed ground surface.
Static water elevation referenced to mark on top of well casing.
Observation well drilled using air rotary techniques.
Steel centralizers installed above well screen and at approximately 50-ft intervals to ground surface.
PVC well screen machine-slotted by manufacturer.
Well development activities conducted on 8/17/2013.
Seep holes drilled into protective steel stick up cover upon completion of well installation.
AMEC Inspector Supervising Well Installation: _J_. _G_o_d_d_a_rd ___________________ _
Static Water Level Elevation (NAVD88) collected December 9, 2013: _7_4_8_.1_5 ____________ _
Type of Locking Device:
Masterlock-Key A953 Type of Casing Protection: ___
S_t_e_e_l S_t_ic_k_U~p __ _
Concrete Surface Pad Dimensions:
2'x2'x0.5' DIAGRAM NOT TO SCALE ctive Steel Cover
- ~
4(
Top of Casing Elevation:
775.03 Prote Top of Concre te Elevation: 772.36 ~
Ground Surface ~
c---
c---~
~-- Ground Surface Elevation: 772.20
\\
v ng Seal I Grout Sea Casi M aterial: Cement-Bentonite Grout 4(
Bottom of Grout Seal I Top of Bentonite Seal Bent onite Seal r Pack Filte M aterial:
DSI NO. 2 Well Sand Well s
s T
s Screen creen Top Depth:
creen Top Elevation:
ype of Well Screen:
creen Opening Size:
50.0 722.2 PVC 0.020" Screen Bottom Depth:
70.0 Screen Bottom Elevation:
702.2 Clinch River Data Report Rev. 4 CRP-1112.16 Page E.1-18 of46 Depth:
40.4 Elevation:
731.8 4(
Filter Pack Top Depth:
46.7 Elevation:
725.5 Well Casing Type:
PVC Size (diameter):
2" Schedule or Thickness:
SCH 40 70.5 J
Bottom Sump/Cap Depth:
73.1 Drilled Depth of Borehole:
14-(f--------l*~ Bore Hole Diameter:----'------
I I
6-8" AMEC Environment & Infrastructure, Inc.
Observation Well Data Sheet Prepared by/Date: MBL 4/29/14 Checked by/Date: WBD 4/29/14 Project Name: ___
Cc_L_I_N__c_C_H_R_IV_E_R_S_M_R_PR_O~JE_Cc_T----'--(A_M_E_C~64_6c_8_-_13'-----1 0_7_2_L_) __
County:
ROANE, TN Observation Weiii.D.: __
O_W_-4_1_7_L __
Date of Observation Well Installation:
8/7/13 Date of Well Development:
8/27/13 Observation Well Northing:
569903.0 US ft Easting:
2446614.6 US ft Observation Well Driller Observation Well Location:
Clinch River SMR Site Name:
B. Woods (M&W)
NOTES:
License No.:
TN #658 Observation well installed in accordance with ASTM D 5092-04(201 O)e1.
Northing and Easting =Tennessee State Plane Coordinates, NAD83, US Survey Feet.
Elevations = North American Vertical Datum of 1988 (NAVD88), Feet.
Depths/elevations referenced to surveyed ground surface.
Static water elevation referenced to mark on top of well casing.
Observation well drilled using air rotary techniques.
Steel centralizers installed above well screen and at approximately 50-ft intervals to ground surface.
PVC well screen machine-slotted by manufacturer.
Well development activities conducted between 8/16/2013 through 8/27/2013.
Seep holes drilled into protective steel stick up cover upon completion of well installation.
AMEC Inspector Supervising Well Installation: _J_. _G_o_d_d_a_rd ___________________ _
Static Water Level Elevation (NAVD88) collected December 9, 2013: _7_4_8_.6_1 ____________ _
Type of Locking Device:
Masterlock-Key A953 Type of Casing Protection: ___
S_t_e_e_l S_t_ic_k_U~p __ _
Concrete Surface Pad Dimensions:
2'x2'x0.5' DIAGRAM NOT TO SCALE ctive Steel Cover
- ~
4(
Top of Casing Elevation:
775.71 Prote Top of Concre te Elevation: 772.78 ~
Ground Surface ~
c---
c---~
~-- Ground Surface Elevation: 772.65
\\
v ng Seal I Grout Sea Casi M aterial: Cement-Bentonite Grout 4(
Bottom of Grout Seal I Top of Bentonite Seal Bent onite Seal r Pack Filte M aterial:
DSI NO. 2 Well Sand Well s
s T
s Screen creen Top Depth:
creen Top Elevation:
ype of Well Screen:
creen Opening Size:
95.0 677.7 PVC 0.020" Screen Bottom Depth:
115.0 Screen Bottom Elevation:
657.7 Clinch River Data Report Rev. 4 CRP-1112.16 Page E.1-19 of46 Depth:
81.8 Elevation:
690.9 4(
Filter Pack Top Depth:
91.5 Elevation:
681.2 Well Casing Type:
PVC Size (diameter):
2" Schedule or Thickness:
SCH 40 115.5 J
Bottom Sump/Cap Depth:
118.0 Drilled Depth of Borehole:
14-(f--------l*~ Bore Hole Diameter:----'------
I I
6-8" AMEC Environment & Infrastructure, Inc.
Observation Well Data Sheet Prepared by/Date: MBL 4/29/14 Checked by/Date: WBD 4/29/14 Project Name: ___
Cc_L_I_N__c_C_H_R_IV_E_R_S_M_R_PR_O~JE_Cc_T----'--(A_M_E_C~64_6c_8_-_13'-----1 0_7_2_L_) __
County:
ROANE, TN Observation Weiii.D.: __
O_W_-_4_1_8__c_U __
Date of Observation Well Installation:
8/29/13 Date of Well Development:
9/14/13 Observation Well Northing:
570526.8 US ft Easting:
2447065.0 US ft Observation Well Driller Observation Well Location:
Clinch River SMR Site Name:
B. Woods (M&W)
NOTES:
License No.:
TN #658 Observation well installed in accordance with ASTM D 5092-04(201 O)e1.
Northing and Easting =Tennessee State Plane Coordinates, NAD83, US Survey Feet.
Elevations = North American Vertical Datum of 1988 (NAVD88), Feet.
Depths/elevations referenced to surveyed ground surface.
Static water elevation referenced to mark on top of well casing.
Observation well drilled using air rotary techniques.
Steel centralizers installed above well screen and at approximately 50-ft intervals to ground surface.
PVC well screen machine-slotted by manufacturer.
Well development activities conducted between 9/13/2013 through 9/14/2013.
Seep holes drilled into protective steel stick up cover upon completion of well installation.
AMEC Inspector Supervising Well Installation: _K_._L_Io~d ____________________ _
Static Water Level Elevation (NAVD88) collected December 9, 2013: _7_6_1_.4_0 ____________ _
Type of Locking Device:
Masterlock-Key A953 Type of Casing Protection: ___
S_t_e_e_l S_t_ic_k_U~p __ _
Concrete Surface Pad Dimensions:
2'x2'x0.5' DIAGRAM NOT TO SCALE ctive Steel Cover
- ~
4(
Top of Casing Elevation:
812.94 Prote Top of Concre te Elevation: 810.30 ~
Ground Surface ~
c---
c---~
~-- Ground Surface Elevation: 810.01
\\
v ng Seal I Grout Sea Casi M aterial: Cement-Bentonite Grout 4(
Bottom of Grout Seal I Top of Bentonite Seal Bent onite Seal r Pack Filte M aterial:
DSI NO. 2 Well Sand Well s
s T
s Screen creen Top Depth:
creen Top Elevation:
ype of Well Screen:
creen Opening Size:
95.0 715.0 PVC 0.020" Screen Bottom Depth:
105.0 Screen Bottom Elevation:
705.0 Clinch River Data Report Rev. 4 CRP-1112.16 Page E.1-20 of 46 Depth:
78.0 Elevation:
732.0 4(
Filter Pack Top Depth:
90.1 Elevation:
719.9 Well Casing Type:
PVC Size (diameter):
2" Schedule or Thickness:
SCH 40 105.5 J
Bottom Sump/Cap Depth:
108.0 Drilled Depth of Borehole:
14-(f--------l*~ Bore Hole Diameter:----'------
I I
6-8" AMEC Environment & Infrastructure, Inc.
Observation Well Data Sheet Prepared by/Date: MBL 4/29/14 Checked by/Date: WBD 4/29/14 Project Name: ___
Cc_L_I_N__c_C_H_R_IV_E_R_S_M_R_PR_O~JE_Cc_T----'--(A_M_E_C~64_6c_8_-_13'-----1 0_7_2_L_) __
County:
ROANE, TN Observation Weiii.D.: __
O_W_-4_1_8_L __
Date of Observation Well Installation:
8/28/13 Date of Well Development:
9/14/13 Observation Well Northing:
570506.0 US ft Easting:
2447038.8 US ft Observation Well Driller Observation Well Location:
Clinch River SMR Site Name:
B. Woods (M&W)
NOTES:
License No.:
TN #658 Observation well installed in accordance with ASTM D 5092-04(201 O)e1.
Northing and Easting =Tennessee State Plane Coordinates, NAD83, US Survey Feet.
Elevations = North American Vertical Datum of 1988 (NAVD88), Feet.
Depths/elevations referenced to surveyed ground surface.
Static water elevation referenced to mark on top of well casing.
Observation well drilled using air rotary techniques.
Steel centralizers installed above well screen and at approximately 50-ft intervals to ground surface.
PVC well screen machine-slotted by manufacturer.
Well development activities conducted between 9/13/2013 through 9/14/2013.
Seep holes drilled into protective steel stick up cover upon completion of well installation.
AMEC Inspector Supervising Well Installation: _K_._L_Io~d ____________________ _
Static Water Level Elevation (NAVD88) collected December 9, 2013: _7_5_0_.5_6 ____________ _
Type of Locking Device:
Masterlock-Key A953 Type of Casing Protection: ___
S_t_e_e_l S_t_ic_k_U~p __ _
Concrete Surface Pad Dimensions:
2'x2'x0.5' DIAGRAM NOT TO SCALE ctive Steel Cover
- ~
4(
Top of Casing Elevation:
814.41 Prote Top of Concre te Elevation: 811.80 ~
Ground Surface ~
c---
c---~
~-- Ground Surface Elevation: 811.44
\\
v ng Seal I Grout Sea Casi M aterial: Cement-Bentonite Grout 4(
Bottom of Grout Seal I Top of Bentonite Seal Bent onite Seal r Pack Filte M aterial:
DSI NO. 2 Well Sand Well s
s T
s Screen creen Top Depth:
creen Top Elevation:
ype of Well Screen:
creen Opening Size:
136.8 674.6 PVC 0.020" Screen Bottom Depth:
156.8 Screen Bottom Elevation:
654.6 Clinch River Data Report Rev. 4 CRP-1112.16 Page E.1-21 of46 Depth:
124.9 Elevation:
686.5 4(
Filter Pack Top Depth:
133.6 Elevation:
677.8 Well Casing Type:
PVC Size (diameter):
2" Schedule or Thickness:
SCH 80 157.3 J
Bottom Sump/Cap Depth:
160.0 Drilled Depth of Borehole:
14-(f--------l*~ Bore Hole Diameter:----'------
I I
6-8" AMEC Environment & Infrastructure, Inc.
Observation Well Data Sheet Prepared by/Date: MBL 4/29/14 Checked by/Date: WBD 4/29/14 Project Name: ___
Cc_L_I_N__c_C_H_R_IV_E_R_S_M_R_PR_O~JE_Cc_T----'--(A_M_E_C~64_6c_8_-_13'-----1 0_7_2_L_) __
County:
ROANE, TN Observation Weiii.D.: __
O_W_-_4_1_9__c_U __
Date of Observation Well Installation:
8/15/13 Date of Well Development:
8/27/13 Observation Well Northing:
571283.4 US ft Easting:
2446716.1 US ft Observation Well Driller Observation Well Location:
Clinch River SMR Site Name:
N. Dempsey (TSD)
NOTES:
License No.:
TN #936 Observation well installed in accordance with ASTM D 5092-04(201 O)e1.
Northing and Easting =Tennessee State Plane Coordinates, NAD83, US Survey Feet.
Elevations = North American Vertical Datum of 1988 (NAVD88), Feet.
Depths/elevations referenced to surveyed ground surface.
Static water elevation referenced to mark on top of well casing.
Observation well drilled using air rotary techniques.
Steel centralizers installed above well screen and at approximately 50-ft intervals to ground surface.
PVC well screen machine-slotted by manufacturer.
Well development activities conducted between 8/19/2013 through 8/27/2013.
Seep holes drilled into protective steel stick up cover upon completion of well installation.
AMEC Inspector Supervising Well Installation: _J_. _H_e_n_s_be_r_r~y __________________ _
Static Water Level Elevation (NAVD88) collected December 9, 2013: _7_6_7_.7_0 ____________ _
Type of Locking Device:
Masterlock-Key A953 Type of Casing Protection: ___
S_t_e_e_l S_t_ic_k_U~p __ _
Concrete Surface Pad Dimensions:
2'x2'x0.5' DIAGRAM NOT TO SCALE ctive Steel Cover
- ~
4(
Top of Casing Elevation:
803.13 Prote Top of Concre te Elevation: 800.21 ~
Ground Surface ~
c---
c---~
~-- Ground Surface Elevation: 799.98
\\
v ng Seal I Grout Sea Casi M aterial: Cement-Bentonite Grout 4(
Bottom of Grout Seal I Top of Bentonite Seal Bent onite Seal r Pack Filte M aterial:
DSI NO. 2 Well Sand Well s
s T
s Screen creen Top Depth:
creen Top Elevation:
ype of Well Screen:
creen Opening Size:
57.2 742.8 PVC 0.020" Screen Bottom Depth:
77.2 Screen Bottom Elevation:
722.8 Clinch River Data Report Rev. 4 CRP-1112.16 Page E.1-22 of 46 Depth:
48.8 Elevation:
751.2 4(
Filter Pack Top Depth:
54.4 Elevation:
745.6 Well Casing Type:
PVC Size (diameter):
2" Schedule or Thickness:
SCH 40 77.7 J
Bottom Sump/Cap Depth:
79.6 Drilled Depth of Borehole:
14-(f--------l*~ Bore Hole Diameter:----'------
I I
6-8" AMEC Environment & Infrastructure, Inc.
Observation Well Data Sheet Prepared by/Date: MBL 4/29/14 Checked by/Date: WBD 4/29/14 Project Name: ___
Cc_L_I_N__c_C_H_R_IV_E_R_S_M_R_PR_O~JE_Cc_T----'--(A_M_E_C~64_6c_8_-_13'-----1 0_7_2_L_) __
County:
ROANE, TN Observation Weiii.D.: __
O_W_-4_1_9_L __
Date of Observation Well Installation:
8/6/13 Date of Well Development:
8/21/13 Observation Well Northing:
571257.7 US ft Easting:
2446683.4 US ft Observation Well Driller Observation Well Location:
Clinch River SMR Site Name:
N. Dempsey (TSD)
NOTES:
License No.:
TN #936 Observation well installed in accordance with ASTM D 5092-04(201 O)e1.
Northing and Easting =Tennessee State Plane Coordinates, NAD83, US Survey Feet.
Elevations = North American Vertical Datum of 1988 (NAVD88), Feet.
Depths/elevations referenced to surveyed ground surface.
Static water elevation referenced to mark on top of well casing.
Observation well drilled using air rotary techniques.
Steel centralizers installed above well screen and at approximately 50-ft intervals to ground surface.
PVC well screen machine-slotted by manufacturer.
Well development activities conducted between 8/20/2013 through 8/21/2013.
Seep holes drilled into protective steel stick up cover upon completion of well installation.
AMEC Inspector Supervising Well Installation: _J_. _H_e_n_s_be_r_r~y __________________ _
Static Water Level Elevation (NAVD88) collected December 9, 2013: _7_6_3_.5_7 ____________ _
Type of Locking Device:
Masterlock-Key A953 Type of Casing Protection: ___
S_t_e_e_l S_t_ic_k_U~p __ _
Concrete Surface Pad Dimensions:
2'x2'x0.5' DIAGRAM NOT TO SCALE ctive Steel Cover
- ~
4(
Top of Casing Elevation:
802.72 Prote Top of Concre te Elevation: 799.89 ~
Ground Surface ~
c---
c---~
~-- Ground Surface Elevation: 799.75
\\
v ng Seal I Grout Sea Casi M aterial: Cement-Bentonite Grout 4(
Bottom of Grout Seal I Top of Bentonite Seal Bent onite Seal r Pack Filte M aterial:
DSI NO. 2 Well Sand Well s
s T
s Screen creen Top Depth:
creen Top Elevation:
ype of Well Screen:
creen Opening Size:
104.5 695.3 PVC 0.020" Screen Bottom Depth:
124.5 Screen Bottom Elevation:
675.3 Clinch River Data Report Rev. 4 CRP-1112.16 Page E.1-23 of 46 Depth:
90.5 Elevation:
709.3 4(
Filter Pack Top Depth:
101.0 Elevation:
698.8 Well Casing Type:
PVC Size (diameter):
2" Schedule or Thickness:
SCH 40 125.0 J
Bottom Sump/Cap Depth:
126.5 Drilled Depth of Borehole:
14-(f--------l*~ Bore Hole Diameter:----'------
I I
6-8" AMEC Environment & Infrastructure, Inc.
Observation Well Data Sheet Prepared by/Date: MBL 4/29/14 Checked by/Date: WBD 4/29/14 Project Name:
CLINCH RIVER SMR PROJECT (AMEC 6468-13-1072)
County:
ROANE, TN Observation Weiii.D.:
OW-420U Date of Observation Well Installation:
8/21/13 Date of Well Development:
8/28/13 Observation Well Northing:
572009.6 US ft Easting:
2446886.0 US ft Observation Well Driller Observation Well Location:
Clinch River SMR Site Name:
N. Dempsey (TSD)
NOTES:
License No.:
TN #936 Observation well installed in accordance with ASTM D 5092-04(201 O)e1.
Northing and Easting =Tennessee State Plane Coordinates, NAD83, US Survey Feet.
Elevations = North American Vertical Datum of 1988 (NAVD88), Feet.
Depths/elevations referenced to surveyed ground surface.
Static water elevation referenced to mark on top of well casing.
Observation well drilled using air rotary techniques.
Steel centralizer installed approximately 24.0 feet below ground surface.
PVC well screen machine-slotted by manufacturer.
Unable to develop well-well taking water.
Seep holes drilled into protective steel stick up cover upon completion of well installation.
AMEC Inspector Supervising Well Installation: _J_. _H_e_n_s_be_r_r~y __________________ _
Static Water Level Elevation (NAVD88) collected December 9, 2013: _7_6_0_.5_8 ____________ _
Type of Locking Device:
Masterlock-Key A953 Type of Casing Protection: ___
S_t_e_e_l S_t_ic_k_U~p __ _
Concrete Surface Pad Dimensions:
2'x2'x0.5' DIAGRAM NOT TO SCALE ctive Steel Cover
- ~
4(
Top of Casing Elevation:
805.70 Prote Top of Concre te Elevation: 803.1 0 ~
Ground Surface ~
c---
c---~
~-- Ground Surface Elevation: 802.85
\\
v ng Seal I Grout Sea Casi M aterial: Cement-Bentonite Grout 4(
Bottom of Grout Seal I Top of Bentonite Seal Bent onite Seal r Pack Filte M aterial:
DSI NO. 2 Well Sand Well s
s T
s Screen creen Top Depth:
creen Top Elevation:
ype of Well Screen:
creen Opening Size:
26.0 776.9 PVC 0.020" Screen Bottom Depth:
46.0 Screen Bottom Elevation:
756.9 Clinch River Data Report Rev. 4 CRP-1112.16 Page E.1-24 of 46 Depth:
15.0 Elevation:
787.9 4(
Filter Pack Top Depth:
21.2 Elevation:
781.7 Well Casing Type:
PVC Size (diameter):
2" Schedule or Thickness:
SCH 40 46.5 J
Bottom Sump/Cap Depth:
48.5 Drilled Depth of Borehole:
14-(f--------l*~ Bore Hole Diameter:----'------
I I
6-8" AMEC Environment & Infrastructure, Inc.
Observation Well Data Sheet Prepared by/Date: MBL 4/29/14 Checked by/Date: WBD 4/29/14 Project Name:
CLINCH RIVER SMR PROJECT (AMEC 6468-13-1072)
County:
ROANE, TN Observation Weiii.D.:
OW-420L Date of Observation Well Installation:
8/20/13 Date of Well Development:
9/3/13 Observation Well Northing:
572021.1 US ft Easting:
2446902.0 US ft Observation Well Driller Observation Well Location:
Clinch River SMR Site Name:
N. Dempsey (TSD)
NOTES:
License No.:
TN #936 Observation well installed in accordance with ASTM D 5092-04(201 O)e1.
Northing and Easting =Tennessee State Plane Coordinates, NAD83, US Survey Feet.
Elevations = North American Vertical Datum of 1988 (NAVD88), Feet.
Depths/elevations referenced to surveyed ground surface.
Static water elevation referenced to mark on top of well casing.
Observation well drilled using air rotary techniques.
Steel centralizers installed above well screen and at approximately 50-ft intervals to ground surface.
PVC well screen machine-slotted by manufacturer.
Well development activities conducted between 8/28/2013 through 9/3/2013.
Seep holes drilled into protective steel stick up cover upon completion of well installation.
AMEC Inspector Supervising Well Installation: _J_. _H_e_n_s_be_r_r~y __________________ _
Static Water Level Elevation (NAVD88) collected December 9, 2013: _7_44_.9_7 ____________ _
Type of Locking Device:
Masterlock-Key A953 Type of Casing Protection: ___
S_t_e_e_l S_t_ic_k_U~p __ _
Concrete Surface Pad Dimensions:
2'x2'x0.5' DIAGRAM NOT TO SCALE ctive Steel Cover
- ~
4(
Top of Casing Elevation:
806.15 Prote Top of Concre te Elevation: 803.31 ~
Ground Surface ~
c---
c---~
~-- Ground Surface Elevation: 803.07
\\
v ng Seal I Grout Sea Casi M aterial: Cement-Bentonite Grout 4(
Bottom of Grout Seal I Top of Bentonite Seal Bent onite Seal r Pack Filte M aterial:
DSI NO. 2 Well Sand Well s
s T
s Screen creen Top Depth:
creen Top Elevation:
ype of Well Screen:
creen Opening Size:
130.9 672.2 PVC 0.020" Screen Bottom Depth:
150.9 Screen Bottom Elevation:
652.2 Clinch River Data Report Rev. 4 CRP-1112.16 Page E.1-25 of 46 Depth:
120.0 Elevation:
683.1 4(
Filter Pack Top Depth:
127.4 Elevation:
675.7 Well Casing Type:
PVC Size (diameter):
2" Schedule or Thickness:
SCH 40 151.4 J
Bottom Sump/Cap Depth:
152.4 Drilled Depth of Borehole:
14-(f--------l*~ Bore Hole Diameter:----'------
I I
6-8" AMEC Environment & Infrastructure, Inc.
Observation Well Data Sheet Prepared by/Date: MBL 4/29/14 Checked by/Date: WBD 4/29/14 Project Name:
CLINCH RIVER SMR PROJECT (AMEC 6468-13-1072)
County:
ROANE, TN Observation Weill.D.:
OW-421 U Date of Observation Well Installation:
8/15/13 Date of Well Development:
9/19/13 Observation Well Northing:
570557.7 US ft Easting:
2446471.7 US ft Observation Well Driller Observation Well Location:
Clinch River SMR Site Name:
B. Woods (M&W)
NOTES:
License No.:
TN #658 Observation well installed in accordance with ASTM D 5092-04(201 O)e1.
Northing and Easting =Tennessee State Plane Coordinates, NAD83, US Survey Feet.
Elevations = North American Vertical Datum of 1988 (NAVD88), Feet.
Depths/elevations referenced to surveyed ground surface.
Static water elevation referenced to mark on top of well casing.
Observation well drilled using air rotary techniques.
Steel centralizers installed above well screen and at approximately 50-ft intervals to ground surface.
PVC well screen machine-slotted by manufacturer.
Well development activities conducted between 8/18/2013 through 9/19/2013.
Seep holes drilled into protective steel stick up cover upon completion of well installation.
AMEC Inspector Supervising Well Installation: _J_. _G_o_d_d_a_rd ___________________ _
Static Water Level Elevation (NAVD88) collected December 9, 2013: _7_54_.2_3 ____________ _
Type of Locking Device:
Masterlock-Key A953 Type of Casing Protection: ___
S_t_e_e_l S_t_ic_k_U~p __ _
Concrete Surface Pad Dimensions:
2'x2'x0.5' DIAGRAM NOT TO SCALE ctive Steel Cover
- ~
4(
Top of Casing Elevation:
808.27 Prote Top of Concre te Elevation: 805.55 ~
Ground Surface ~
c---
c---~
~-- Ground Surface Elevation: 805.36
\\
v ng Seal I Grout Sea Casi M aterial: Cement-Bentonite Grout 4(
Bottom of Grout Seal I Top of Bentonite Seal Bent onite Seal r Pack Filte M aterial:
DSI NO. 2 Well Sand Well s
s T
s Screen creen Top Depth:
creen Top Elevation:
ype of Well Screen:
creen Opening Size:
55.0 750.4 PVC 0.020" Screen Bottom Depth:
75.0 Screen Bottom Elevation:
730.4 Clinch River Data Report Rev. 4 CRP-1112.16 Page E.1-26 of 46 Depth:
41.2 Elevation:
764.2 4(
Filter Pack Top Depth:
51.4 Elevation:
754.0 Well Casing Type:
PVC Size (diameter):
2" Schedule or Thickness:
SCH 40 75.5 J
Bottom Sump/Cap Depth:
78.0 Drilled Depth of Borehole:
14-(f--------l*~ Bore Hole Diameter:----'------
I I
6-8" AMEC Environment & Infrastructure, Inc.
Observation Well Data Sheet Prepared by/Date: MBL 4/29/14 Checked by/Date: WBD 4/29/14 Project Name:
CLINCH RIVER SMR PROJECT (AMEC 6468-13-1072)
County:
ROANE, TN Observation Weiii.D.:
OW-421L Date of Observation Well Installation:
8/14/13 Date of Well Development:
9/19/13 Observation Well Northing:
570544.2 US ft Easting:
2446455.6 US ft Observation Well Driller Observation Well Location:
Clinch River SMR Site Name:
B. Woods (M&W)
NOTES:
License No.:
TN #658 Observation well installed in accordance with ASTM D 5092-04(201 O)e1.
Northing and Easting =Tennessee State Plane Coordinates, NAD83, US Survey Feet.
Elevations = North American Vertical Datum of 1988 (NAVD88), Feet.
Depths/elevations referenced to surveyed ground surface.
Static water elevation referenced to mark on top of well casing.
Observation well drilled using air rotary techniques.
Steel centralizers installed above well screen and at approximately 50-ft intervals to ground surface.
PVC well screen machine-slotted by manufacturer.
Well development activities conducted between 8/18/2013 through 9/19/2013.
Seep holes drilled into protective steel stick up cover upon completion of well installation.
AMEC Inspector Supervising Well Installation: _J_. _G_o_d_d_a_rd ___________________ _
Static Water Level Elevation (NAVD88) collected December 9, 2013: _7_44_.6_8 ____________ _
Type of Locking Device:
Masterlock-Key A953 Type of Casing Protection: ___
S_t_e_e_l S_t_ic_k_U~p __ _
Concrete Surface Pad Dimensions:
2'x2'x0.5' DIAGRAM NOT TO SCALE ctive Steel Cover
- ~
4(
Top of Casing Elevation:
807.81 Prote Top of Concre te Elevation: 805.05 ~
Ground Surface ~
c---
c---~
~-- Ground Surface Elevation: 804.78
\\
v ng Seal I Grout Sea Casi M aterial: Cement-Bentonite Grout 4(
Bottom of Grout Seal I Top of Bentonite Seal Bent onite Seal r Pack Filte M aterial:
DSI NO. 2 Well Sand Well s
s T
s Screen creen Top Depth:
creen Top Elevation:
ype of Well Screen:
creen Opening Size:
104.8 700.0 PVC 0.020" Screen Bottom Depth:
124.8 Screen Bottom Elevation:
680.0 Clinch River Data Report Rev. 4 CRP-1112.16 Page E.1-27 of 46 Depth:
92.4 Elevation:
712.4 4(
Filter Pack Top Depth:
101.0 Elevation:
703.8 Well Casing Type:
PVC Size (diameter):
2" Schedule or Thickness:
SCH 40 125.3 J
Bottom Sump/Cap Depth:
128.0 Drilled Depth of Borehole:
14-(f--------l*~ Bore Hole Diameter:----'------
I I
6-8" AMEC Environment & Infrastructure, Inc.
Observation Well Data Sheet Prepared by/Date: MBL 4/29/14 Checked by/Date: WBD 4/29/14 Project Name:
CLINCH RIVER SMR PROJECT (AMEC 6468-13-1072)
County:
ROANE, TN Observation Weill.D.:
OW-421 D Date of Observation Well Installation:
8/13/13 Date of Well Development:
9/19/13 Observation Well Northing:
570520.1 US ft Easting:
2446424.4 US ft Observation Well Driller Observation Well Location:
Clinch River SMR Site Name:
B. Woods (M&W)
NOTES:
License No.:
TN #658 Observation well installed in accordance with ASTM D 5092-04(201 O)e1.
Northing and Easting =Tennessee State Plane Coordinates, NAD83, US Survey Feet.
Elevations = North American Vertical Datum of 1988 (NAVD88), Feet.
Depths/elevations referenced to surveyed ground surface.
Static water elevation referenced to mark on top of well casing.
Observation well drilled using air rotary techniques.
Steel centralizers installed above well screen and at approximately 50-ft intervals to ground surface.
PVC well screen machine-slotted by manufacturer.
Well development activities conducted between 8/19/2013 through 9/19/2013.
Seep holes drilled into protective steel stick up cover upon completion of well installation.
AMEC Inspector Supervising Well Installation: _J_. _G_o_d_d_a_rd ___________________ _
Static Water Level Elevation (NAVD88) collected December 9, 2013: _7_44_.0_2 ____________ _
Type of Locking Device:
Masterlock-Key A953 Type of Casing Protection: ___
S_t_e_e_l S_t_ic_k_U~p __ _
Concrete Surface Pad Dimensions:
2'x2'x0.5' DIAGRAM NOT TO SCALE ctive Steel Cover
- ~
4(
Top of Casing Elevation:
805.20 Prote Top of Concre te Elevation: 802.63 ~
Ground Surface ~
c---
c---~
~-- Ground Surface Elevation: 802.49
\\
v ng Seal I Grout Sea Casi M aterial: Cement-Bentonite Grout 4(
Bottom of Grout Seal I Top of Bentonite Seal Bent onite Seal r Pack Filte M aterial:
DSI NO. 2 Well Sand Well s
s T
s Screen creen Top Depth:
creen Top Elevation:
ype of Well Screen:
creen Opening Size:
175.7 626.8 PVC 0.020" Screen Bottom Depth:
195.7 Screen Bottom Elevation:
606.8 Clinch River Data Report Rev. 4 CRP-1112.16 Page E.1-28 of 46 Depth:
165.2 Elevation:
637.3 4(
Filter Pack Top Depth:
172.8 Elevation:
629.7 Well Casing Type:
PVC Size (diameter):
2" Schedule or Thickness:
SCH 80 196.2 J
Bottom Sump/Cap Depth:
198.0 Drilled Depth of Borehole:
14-(f--------l*~ Bore Hole Diameter:----'------
I I
6-8" AMEC Environment & Infrastructure, Inc.
Observation Well Data Sheet Prepared by/Date: MBL 4/29/14 Checked by/Date: WBD 4/29/14 Project Name: ___
Cc_L_I_N__c_C_H_R_IV_E_R_S_M_R_PR_O~JE_Cc_T----'--(A_M_E_C~64_6c_8_-_13'-----1 0_7_2_L_) __
County:
ROANE, TN Observation Weiii.D.: __
O_W_-_4_2_2__c_U __
Date of Observation Well Installation:
8/3/13 Date of Well Development:
See Note 9 Observation Well Northing:
570450.2 US ft Easting:
2448763.8 US ft Observation Well Driller Observation Well Location:
Clinch River SMR Site Name:
B. Woods (M&W)
NOTES:
License No.:
TN #658
- 1. Observation well installed in accordance with ASTM D 5092-04(2010)e1.
- 2. Northing and Easting = Tennessee State Plane Coordinates, NAD83, US Survey Feet.
- 3. Elevations = North American Vertical Datum of 1988 (NAVD88), Feet.
- 4. Depths/elevations referenced to ground surface. Ground Surface Elevation = 802.4 ft.
- 5. Concrete Pad not constructed at time of survey.
- 6. Observation well drilled using air rotary techniques.
- 7. Steel centralizer installed approximately 20.0 feet below ground surface.
- 8. PVC well screen machine-slotted by manufacturer.
- 9. Well development was not completed by AMEC-no static water levels obtained.
- 10. Seep holes drilled into protective steel stick up cover upon completion of well installation.
- 11. Well installation dimensions are approximate due to access limitations for AMEC survey personnel.
- 12. Control of well relinquished to TVA due to contamination identified in OW-422L.
AMEC Inspector Supervising Well Installation: _J_. _G_o_d_d_a_rd ___________________ _
Static Water Level Elevation (NAVD88) collected December 9, 2013: _S_e_e_N_o_t_e_9 __________ _
Type of Locking Device:
Wells controlled by TVA Type of Casing Protection:
Steel Stick Up Concrete Surface Pad Dimensions:
2'x2'x0.5' DIAGRAM NOT TO SCALE ctive Steel Cover
- ~
4(
Top of Casing Elevation:
804.90 Prote Top of Concre te Elevation:NA-Note ~
Ground Surface ~
c---
c---~
~-- Ground Surface Elevation:
802.40
\\
v ng Seal I Grout Sea Casi M aterial: Cement-Bentonite Grout 4(
Bottom of Grout Seal I Top of Bentonite Seal Bent onite Seal r Pack Filte M aterial:
DSI NO. 2 Well Sand Well s
s T
s Screen creen Top Depth:
creen Top Elevation:
ype of Well Screen:
creen Opening Size:
21.0 781.4 PVC 0.020" Screen Bottom Depth:
41.0 Screen Bottom Elevation:
761.4 Clinch River Data Report Rev. 4 CRP-1112.16 Page E.1-29 of 46 Depth:
9.7 Elevation
792.7 4(
Filter Pack Top Depth:
17.9 Elevation:
784.5 Well Casing Type:
PVC Size (diameter):
2" Schedule or Thickness:
SCH 40 41.5 J
Bottom Sump/Cap Depth:
44.0 Drilled Depth of Borehole:
14-(f--------l*~ Bore Hole Diameter:----'------
I I
6-8" AMEC Environment & Infrastructure, Inc.
Observation Well Data Sheet Prepared by/Date: MBL 4/29/14 Checked by/Date: WBD 4/29/14 Project Name: ___
Cc_L_I_N__c_C_H_R_IV_E_R_S_M_R_PR_O~JE_Cc_T----'--(A_M_E_C~64_6c_8_-_13'-----1 0_7_2_L_) __
County:
ROANE, TN Observation Weiii.D.: __
O_W_-4_2_2_L __
Date of Observation Well Installation:
8/3/13 Date of Well Development:
See Note 9 Observation Well Northing:
570438.1 US ft Easting:
24487 48.1 US ft Observation Well Driller Observation Well Location:
Clinch River SMR Site Name:
B. Woods (M&W)
NOTES:
License No.:
TN #658
- 1. Observation well installed in accordance with ASTM D 5092-04(2010)e1.
- 2. Northing and Easting = Tennessee State Plane Coordinates, NAD83, US Survey Feet.
- 3. Elevations = North American Vertical Datum of 1988 (NAVD88), Feet.
- 4. Depths/elevations referenced to ground surface. Ground Surface Elevation = 801.7 ft.
- 5. Concrete Pad not constructed at time of survey.
- 6. Observation well drilled using air rotary techniques.
- 7. Steel centralizers installed above well screen and at approximately 50-ft intervals to ground surface.
- 8. PVC well screen machine-slotted by manufacturer.
- 9. Well development was not completed by AMEC-no static water levels obtained.
- 10. Seep holes drilled into protective steel stick up cover upon completion of well installation.
- 11. Well installation dimensions are approximate due to access limitations for AMEC survey personnel.
- 12. Control of well relinquished to TVA due to contamination identified in OW-422L.
AMEC Inspector Supervising Well Installation: _J_. _G_o_d_d_a_rd ___________________ _
Static Water Level Elevation (NAVD88) collected December 9, 2013: _S_e_e_N_o_t_e_9 __________ _
Type of Locking Device:
Wells controlled by TVA Type of Casing Protection:
Steel Stick Up Concrete Surface Pad Dimensions:
2'x2'x0.5' DIAGRAM NOT TO SCALE ctive Steel Cover
- ~
4(
Top of Casing Elevation:
803.70 Prote Top of Concre te Elevation:NA-Note ~
Ground Surface ~
c---
c---~
~-- Ground Surface Elevation:
801.70
\\
v ng Seal I Grout Sea Casi M aterial: Cement-Bentonite Grout 4(
Bottom of Grout Seal I Top of Bentonite Seal Bent onite Seal r Pack Filte M aterial:
DSI NO. 2 Well Sand Well s
s T
s Screen creen Top Depth:
creen Top Elevation:
ype of Well Screen:
creen Opening Size:
158.0 643.7 PVC 0.020" Screen Bottom Depth:
178.0 Screen Bottom Elevation:
623.7 Clinch River Data Report Rev. 4 CRP-1112.16 Page E.1-30 of 46 Depth:
147.3 Elevation:
654.4 4(
Filter Pack Top Depth:
155.2 Elevation:
646.5 Well Casing Type:
PVC Size (diameter):
2" Schedule or Thickness:
SCH 80 178.5 J
Bottom Sump/Cap Depth:
181.0 Drilled Depth of Borehole:
14-(f--------l*~ Bore Hole Diameter:----'------
I I
6-8" AMEC Environment & Infrastructure, Inc.
Observation Well Data Sheet Prepared by/Date: MBL 4/29/14 Checked by/Date: WBD 4/29/14 Project Name: ___
Cc_L_I_N__c_C_H_R_IV_E_R_S_M_R_PR_O~JE_Cc_T----'--(A_M_E_C~64_6c_8_-_13'-----1 0_7_2_L_) __
County:
ROANE, TN Observation Weiii.D.: __
O_W_-_4_2_2_D __
Date of Observation Well Installation:
8/2/13 Date of Well Development:
See Note 9 Observation Well Northing:
570444.3 US ft Easting:
2448756.2 US ft Observation Well Driller Observation Well Location:
Clinch River SMR Site Name:
B. Woods (M&W)
NOTES:
License No.:
TN #658
- 1. Observation well installed in accordance with ASTM D 5092-04(2010)e1.
- 2. Northing and Easting = Tennessee State Plane Coordinates, NAD83, US Survey Feet.
- 3. Elevations = North American Vertical Datum of 1988 (NAVD88), Feet.
- 4. Depths/elevations referenced to ground surface. Ground Surface Elevation = 802.1 ft.
- 5. Concrete Pad not constructed at time of survey.
- 6. Observation well drilled using air rotary techniques.
- 7. Steel centralizers installed above well screen and at approximately 50-ft intervals to ground surface.
- 8. PVC well screen machine-slotted by manufacturer.
- 9. Well development was not completed by AMEC-no static water levels obtained.
- 10. Seep holes drilled into protective steel stick up cover upon completion of well installation.
- 11. Well installation dimensions are approximate due to access limitations for AMEC survey personnel.
- 12. Control of well relinquished to TVA due to contamination identified in OW-422L.
AMEC Inspector Supervising Well Installation: _J_. _G_o_d_d_a_rd ___________________ _
Static Water Level Elevation (NAVD88) collected December 9, 2013: _S_e_e_N_o_t_e_9 __________ _
Type of Locking Device:
Wells controlled by TVA Type of Casing Protection:
Steel Stick Up Concrete Surface Pad Dimensions:
2'x2'x0.5' DIAGRAM NOT TO SCALE ctive Steel Cover
- ~
4(
Top of Casing Elevation:
805.40 Prote Top of Concre te Elevation:NA-Note ~
Ground Surface ~
c---
c---~
~-- Ground Surface Elevation:
802.10
\\
v ng Seal I Grout Sea Casi M aterial: Cement-Bentonite Grout 4(
Bottom of Grout Seal I Top of Bentonite Seal Bent onite Seal r Pack Filte M aterial:
DSI NO. 2 Well Sand Well s
s T
s Screen creen Top Depth:
creen Top Elevation:
ype of Well Screen:
creen Opening Size:
290.0 512.1 PVC 0.020" Screen Bottom Depth:
310.0 Screen Bottom Elevation:
492.1 Clinch River Data Report Rev. 4 CRP-1112.16 Page E.1-31 of46 Depth:
281.2 Elevation:
520.9 4(
Filter Pack Top Depth:
286.2 Elevation:
515.9 Well Casing Type:
PVC Size (diameter):
2" Schedule or Thickness:
SCH 80 310.5 J
Bottom Sump/Cap Depth:
313.0 Drilled Depth of Borehole:
14-(f--------l*~ Bore Hole Diameter:----'------
I I
6-8" AMEC Environment & Infrastructure, Inc.
Observation Well Data Sheet Prepared by/Date: MBL 4/29/14 Checked by/Date: WBD 4/29/14 Project Name:
CLINCH RIVER SMR PROJECT (AMEC 6468-13-1072)
County:
ROANE, TN Observation Weiii.D.:
OW-423U Date of Observation Well Installation:
8/18/13 Date of Well Development:
9/1/13 Observation Well Northing:
571494.1 US ft Easting:
2448309.5 US ft Observation Well Driller Observation Well Location:
Clinch River SMR Site Name:
B. Woods (M&W)
NOTES:
License No.:
TN #658 Observation well installed in accordance with ASTM D 5092-04(201 O)e1.
Northing and Easting =Tennessee State Plane Coordinates, NAD83, US Survey Feet.
Elevations = North American Vertical Datum of 1988 (NAVD88), Feet.
Depths/elevations referenced to surveyed ground surface.
Static water elevation referenced to mark on top of well casing.
Observation well drilled using air rotary techniques.
Steel centralizers installed approximately 21.0 and 41.0 feet below ground surface.
PVC well screen machine-slotted by manufacturer.
Well development activities conducted between 8/31/2013 through 9/1/2013.
Seep holes drilled into protective steel stick up cover upon completion of well installation.
AMEC Inspector Supervising Well Installation: _J_. _G_o_d_d_a_rd ___________________ _
Static Water Level Elevation (NAVD88) collected December 9, 2013: _7_6_5_.6_0 ____________ _
Type of Locking Device:
Masterlock-Key A953 Type of Casing Protection: ___
S_t_e_e_l S_t_ic_k_U~p __ _
Concrete Surface Pad Dimensions:
2'x2'x0.5' DIAGRAM NOT TO SCALE ctive Steel Cover
- ~
4(
Top of Casing Elevation:
800.21 Prote Top of Concre te Elevation: 797.53 ~
Ground Surface ~
c---
c---~
~-- Ground Surface Elevation: 797.41
\\
v ng Seal I Grout Sea Casi M aterial: Cement-Bentonite Grout 4(
Bottom of Grout Seal I Top of Bentonite Seal Bent onite Seal r Pack Filte M aterial:
DSI NO. 2 Well Sand Well s
s T
s Screen creen Top Depth:
creen Top Elevation:
ype of Well Screen:
creen Opening Size:
42.2 755.2 PVC 0.020" Screen Bottom Depth:
62.2 Screen Bottom Elevation:
735.2 Clinch River Data Report Rev. 4 CRP-1112.16 Page E.1-32 of 46 Depth:
31.5 Elevation:
765.9 4(
Filter Pack Top Depth:
39.1 Elevation:
758.3 Well Casing Type:
PVC Size (diameter):
2" Schedule or Thickness:
SCH 40 62.7 J
Bottom Sump/Cap Depth:
65.0 Drilled Depth of Borehole:
14-(f--------l*~ Bore Hole Diameter:----'------
I I
6-8" AMEC Environment & Infrastructure, Inc.
Observation Well Data Sheet Prepared by/Date: MBL 4/29/14 Checked by/Date: WBD 4/29/14 Project Name:
CLINCH RIVER SMR PROJECT (AMEC 6468-13-1072)
County:
ROANE, TN Observation Weiii.D.:
OW-423L Date of Observation Well Installation:
8/17/13 Date of Well Development:
9/2/13 Observation Well Northing:
571481.6 US ft Easting:
2448293.2 US ft Observation Well Driller Observation Well Location:
Clinch River SMR Site Name:
B. Woods (M&W)
NOTES:
License No.:
TN #658 Observation well installed in accordance with ASTM D 5092-04(201 O)e1.
Northing and Easting =Tennessee State Plane Coordinates, NAD83, US Survey Feet.
Elevations = North American Vertical Datum of 1988 (NAVD88), Feet.
Depths/elevations referenced to surveyed ground surface.
Static water elevation referenced to mark on top of well casing.
Observation well drilled using air rotary techniques.
Steel centralizers installed above well screen and at approximately 50-ft intervals to ground surface.
PVC well screen machine-slotted by manufacturer.
Well development activities conducted between 9/1/2013 through 9/2/2013.
Seep holes drilled into protective steel stick up cover upon completion of well installation.
AMEC Inspector Supervising Well Installation: _J_. _G_o_d_d_a_rd ___________________ _
Static Water Level Elevation (NAVD88) collected December 9, 2013: _7_8_0_.2_9 ____________ _
Type of Locking Device:
Masterlock-Key A953 Type of Casing Protection: ___
S_t_e_e_l S_t_ic_k_U~p __ _
Concrete Surface Pad Dimensions:
2'x2'x0.5' DIAGRAM NOT TO SCALE ctive Steel Cover
- ~
4(
Top of Casing Elevation:
801.13 Prote Top of Concre te Elevation: 798.33 ~
Ground Surface ~
c---
c---~
~-- Ground Surface Elevation: 798.02
\\
v ng Seal I Grout Sea Casi M aterial: Cement-Bentonite Grout 4(
Bottom of Grout Seal I Top of Bentonite Seal Bent onite Seal r Pack Filte M aterial:
DSI NO. 2 Well Sand Well s
s T
s Screen creen Top Depth:
creen Top Elevation:
ype of Well Screen:
creen Opening Size:
139.6 658.4 PVC 0.020" Screen Bottom Depth:
159.6 Screen Bottom Elevation:
638.4 Clinch River Data Report Rev. 4 CRP-1112.16 Page E.1-33 of 46 Depth:
127.9 Elevation:
670.1 4(
Filter Pack Top Depth:
136.6 Elevation:
661.4 Well Casing Type:
PVC Size (diameter):
2" Schedule or Thickness:
SCH 80 160.1 J
Bottom Sump/Cap Depth:
163.0 Drilled Depth of Borehole:
14-(f--------l*~ Bore Hole Diameter:----'------
I I
6-8" AMEC Environment & Infrastructure, Inc.
Observation Well Data Sheet Prepared by/Date: MBL 4/29/14 Checked by/Date: WBD 4/29/14 Project Name:
CLINCH RIVER SMR PROJECT (AMEC 6468-13-1072)
County:
ROANE, TN Observation Weiii.D.:
OW-423D Date of Observation Well Installation:
8/16/13 Date of Well Development:
9/13/13 Observation Well Northing:
571457.9 US ft Easting:
2448262.0 US ft Observation Well Driller Observation Well Location:
Clinch River SMR Site Name:
B. Woods (M&W)
NOTES:
License No.:
TN #658 Observation well installed in accordance with ASTM D 5092-04(201 O)e1.
Northing and Easting =Tennessee State Plane Coordinates, NAD83, US Survey Feet.
Elevations = North American Vertical Datum of 1988 (NAVD88), Feet.
Depths/elevations referenced to surveyed ground surface.
Static water elevation referenced to mark on top of well casing.
Observation well drilled using air rotary techniques.
Steel centralizers installed above well screen and at approximately 50-ft intervals to ground surface.
PVC well screen machine-slotted by manufacturer.
Well development activities conducted between 9/4/2013 through 9/13/2013.
Seep holes drilled into protective steel stick up cover upon completion of well installation.
AMEC Inspector Supervising Well Installation: _J_. _G_o_d_d_a_rd ___________________ _
Static Water Level Elevation (NAVD88) collected December 9, 2013: _7_82_.2_8 ____________ _
Type of Locking Device:
Masterlock-Key A953 Type of Casing Protection: ___
S_t_e_e_l S_t_ic_k_U~p __ _
Concrete Surface Pad Dimensions:
2'x2'x0.5' DIAGRAM NOT TO SCALE ctive Steel Cover
- ~
4(
Top of Casing Elevation:
802.86 Prote Top of Concre te Elevation: 800.13 ~
Ground Surface ~
c---
c---~
~-- Ground Surface Elevation: 799.89
\\
v ng Seal I Grout Sea Casi M aterial: Cement-Bentonite Grout 4(
Bottom of Grout Seal I Top of Bentonite Seal Bent onite Seal r Pack Filte M aterial:
DSI NO. 2 Well Sand Well s
s T
s Screen creen Top Depth:
creen Top Elevation:
ype of Well Screen:
creen Opening Size:
248.1 551.8 PVC 0.020" Screen Bottom Depth:
268.1 Screen Bottom Elevation:
531.8 Clinch River Data Report Rev. 4 CRP-1112.16 Page E.1-34 of 46 Depth:
236.9 Elevation:
563.0 4(
Filter Pack Top Depth:
244.2 Elevation:
555.7 Well Casing Type:
PVC Size (diameter):
2" Schedule or Thickness:
SCH 80 268.6 J
Bottom Sump/Cap Depth:
273.0 Drilled Depth of Borehole:
14-(f--------l*~ Bore Hole Diameter:----'------
I I
6-8" AMEC Environment & Infrastructure, Inc.
Observation Well Data Sheet Prepared by/Date: MBL 4/29/14 Checked by/Date: WBD 4/29/14 Project Name: ___
Cc_L_I_N__c_C_H_R_IV_E_R_S_M_R_PR_O~JE_Cc_T----'--(A_M_E_C~64_6c_8_-_13'-----1 0_7_2_L_) __
County:
ROANE, TN Observation Weiii.D.: __
O_W_-_4_2_8__c_U __
Date of Observation Well Installation:
10/16/13 Date of Well Development:
10/31/13 Observation Well Northing:
570781.4 US ft Easting:
2448710.6 US ft Observation Well Driller Observation Well Location:
Clinch River SMR Site Name:
B. Woods (M&W)
NOTES:
License No.:
TN #658 Observation well installed in accordance with ASTM D 5092-04(201 O)e1.
Northing and Easting =Tennessee State Plane Coordinates, NAD83, US Survey Feet.
Elevations = North American Vertical Datum of 1988 (NAVD88), Feet.
Depths/elevations referenced to surveyed ground surface.
Static water elevation referenced to mark on top of well casing.
Observation well drilled using air rotary techniques.
Steel centralizers installed above well screen and at approximately 50-ft intervals to ground surface.
PVC well screen machine-slotted by manufacturer.
Well development activities conducted between 10/30/2013 through 10/31/2013.
Seep holes drilled into protective steel stick up cover upon completion of well installation.
AMEC Inspector Supervising Well Installation: _N_._S_m_ith ____________________ _
Static Water Level Elevation (NAVD88) collected December 9, 2013: _7_9_0_.2_7 ____________ _
Type of Locking Device:
Masterlock-Key A953 Type of Casing Protection: ___
S_t_e_e_l S_t_ic_k_U~p __ _
Concrete Surface Pad Dimensions:
2'x2'x0.5' DIAGRAM NOT TO SCALE ctive Steel Cover
- ~
4(
Top of Casing Elevation:
807.78 Prote Top of Concre te Elevation: 804.57 ~
Ground Surface ~
c---
c---~
~-- Ground Surface Elevation:
804.33
\\
v ng Seal I Grout Sea Casi M aterial: Cement-Bentonite Grout 4(
Bottom of Grout Seal I Top of Bentonite Seal Bent onite Seal r Pack Filte M aterial:
DSI NO. 2 Well Sand Well s
s T
s Screen creen Top Depth:
creen Top Elevation:
ype of Well Screen:
creen Opening Size:
40.4 763.9 PVC 0.020" Screen Bottom Depth:
60.4 Screen Bottom Elevation:
7 43.9 Clinch River Data Report Rev. 4 CRP-1112.16 Page E.1-35 of 46 Depth:
24.4 Elevation:
779.9 4(
Filter Pack Top Depth:
34.4 Elevation:
769.9 Well Casing Type:
PVC Size (diameter):
2" Schedule or Thickness:
SCH 40 60.9 J
Bottom Sump/Cap Depth:
63.0 Drilled Depth of Borehole:
14-(f--------l*~ Bore Hole Diameter: _
____c __
I I
6" AMEC Environment & Infrastructure, Inc.
Observation Well Data Sheet Prepared by/Date: MBL 4/29/14 Checked by/Date: WBD 4/29/14 Project Name: ___
Cc_L_I_N__c_C_H_R_IV_E_R_S_M_R_PR_O~JE_Cc_T----'--(A_M_E_C~64_6c_8_-_13'-----1 0_7_2_L_) __
County:
ROANE, TN Observation Weiii.D.: __
O_W_-4_2_8_L __
Date of Observation Well Installation:
10/11/13 Date of Well Development:
11/5/13 Observation Well Northing:
570767.9 US ft Easting:
2448696.6 US ft Observation Well Driller Observation Well Location:
Clinch River SMR Site Name:
B. Woods (M&W)
NOTES:
License No.:
TN #658 Observation well installed in accordance with ASTM D 5092-04(201 O)e1.
Northing and Easting =Tennessee State Plane Coordinates, NAD83, US Survey Feet.
Elevations = North American Vertical Datum of 1988 (NAVD88), Feet.
Depths/elevations referenced to surveyed ground surface.
Static water elevation referenced to mark on top of well casing.
Observation well drilled using air rotary techniques.
Steel centralizers installed above well screen and at approximately 50-ft intervals to ground surface.
PVC well screen machine-slotted by manufacturer.
Well development activities conducted between 10/30/2013 through 11/5/2013.
Seep holes drilled into protective steel stick up cover upon completion of well installation.
AMEC Inspector Supervising Well Installation: _N_._S_m_ith ____________________ _
Static Water Level Elevation (NAVD88) collected December 9, 2013: _7_8_7_.2_1 ____________ _
Type of Locking Device:
Masterlock-Key A953 Type of Casing Protection: ___
S_t_e_e_l S_t_ic_k_U~p __ _
Concrete Surface Pad Dimensions:
2'x2'x0.5' DIAGRAM NOT TO SCALE ctive Steel Cover
- ~
4(
Top of Casing Elevation:
807.06 Prote Top of Concre te Elevation: 804.18 ~
Ground Surface ~
c---
c---~
~-- Ground Surface Elevation:
803.86
\\
v ng Seal I Grout Sea Casi M aterial: Cement-Bentonite Grout 4(
Bottom of Grout Seal I Top of Bentonite Seal Bent onite Seal r Pack Filte M aterial:
DSI NO. 2 Well Sand Well s
s T
s Screen creen Top Depth:
creen Top Elevation:
ype of Well Screen:
creen Opening Size:
115.2 688.7 PVC 0.020" Screen Bottom Depth:
135.2 Screen Bottom Elevation:
668.7 Clinch River Data Report Rev. 4 CRP-1112.16 Page E.1-36 of 46 Depth:
100.5 Elevation:
703.4 4(
Filter Pack Top Depth:
110.2 Elevation:
693.7 Well Casing Type:
PVC Size (diameter):
2" Schedule or Thickness:
SCH 40 135.7 J
Bottom Sump/Cap Depth:
138.0 Drilled Depth of Borehole:
14-(f--------l*~ Bore Hole Diameter: _
____c __
I I
6" AMEC Environment & Infrastructure, Inc.
Observation Well Data Sheet Prepared by/Date: MBL 4/29/14 Checked by/Date: WBD 4/29/14 Project Name: ___
Cc_L_I_N__c_C_H_R_IV_E_R_S_M_R_PR_O~JE_Cc_T----'--(A_M_E_C~64_6c_8_-_13'-----1 0_7_2_L_) __
County:
ROANE, TN Observation Weiii.D.: __
O_W_-_4_2_8_D __
Date of Observation Well Installation:
10/10/13 Date of Well Development:
11/7/13 Observation Well Northing:
570741.9 US ft Easting:
2448666.5 US ft Observation Well Driller Observation Well Location:
Clinch River SMR Site Name:
B. Woods (M&W)
NOTES:
License No.:
TN #658 Observation well installed in accordance with ASTM D 5092-04(201 O)e1.
Northing and Easting =Tennessee State Plane Coordinates, NAD83, US Survey Feet.
Elevations = North American Vertical Datum of 1988 (NAVD88), Feet.
Depths/elevations referenced to surveyed ground surface.
Static water elevation referenced to mark on top of well casing.
Observation well drilled using air rotary techniques.
Steel centralizers installed above well screen and at approximately 50-ft intervals to ground surface.
PVC well screen machine-slotted by manufacturer.
Well development activities conducted between 11/5/2013 through 11/7/2013.
Seep holes drilled into protective steel stick up cover upon completion of well installation.
AMEC Inspector Supervising Well Installation: _N_._S_m_ith ____________________ _
Static Water Level Elevation (NAVD88) collected December 9, 2013: _7_9_5_.9_8 ____________ _
Type of Locking Device:
Masterlock-Key A953 Type of Casing Protection: ___
S_t_e_e_l S_t_ic_k_U~p __ _
Concrete Surface Pad Dimensions:
2'x2'x0.5' DIAGRAM NOT TO SCALE ctive Steel Cover
- ~
4(
Top of Casing Elevation:
807.03 Prote Top of Concre te Elevation: 804.02 ~
Ground Surface ~
c---
c---~
~-- Ground Surface Elevation:
803.73
\\
v ng Seal I Grout Sea Casi M aterial: Cement-Bentonite Grout 4(
Bottom of Grout Seal I Top of Bentonite Seal Bent onite Seal r Pack Filte M aterial:
DSI NO. 2 Well Sand Well s
s T
s Screen creen Top Depth:
creen Top Elevation:
ype of Well Screen:
creen Opening Size:
190.2 613.5 PVC 0.020" Screen Bottom Depth:
210.2 Screen Bottom Elevation:
593.5 Clinch River Data Report Rev. 4 CRP-1112.16 Page E.1-37 of 46 Depth:
172.2 Elevation:
631.5 4(
Filter Pack Top Depth:
185.2 Elevation:
618.5 Well Casing Type:
PVC Size (diameter):
2" Schedule or Thickness:
SCH 80 210.7 J
Bottom Sump/Cap Depth:
213.0 Drilled Depth of Borehole:
14-(f--------l*~ Bore Hole Diameter: _
____c __
I I
6" AMEC Environment & Infrastructure, Inc.
Observation Well Data Sheet Prepared by/Date: MBL 4/29/14 Checked by/Date: WBD 4/29/14 Project Name: ___
Cc_L_I_N__c_C_H_R_IV_E_R_S_M_R_PR_O~JE_Cc_T----'--(A_M_E_C~64_6c_8_-_13'-----1 0_7_2_L_) __
County:
ROANE, TN Observation Weiii.D.: __
O_W_-_4_2_9__c_U __
Date of Observation Well Installation:
10/11/13 Date of Well Development:
11/10/13 Observation Well Northing:
569989.1 US ft Easting:
2448606.2 US ft Observation Well Driller Observation Well Location:
Clinch River SMR Site Name:
G. Akins (M&W)
NOTES:
License No.:
TN #658 Observation well installed in accordance with ASTM D 5092-04(201 O)e1.
Northing and Easting =Tennessee State Plane Coordinates, NAD83, US Survey Feet.
Elevations = North American Vertical Datum of 1988 (NAVD88), Feet.
Depths/elevations referenced to surveyed ground surface.
Static water elevation referenced to mark on top of well casing.
Observation well drilled using air rotary techniques.
Steel centralizers installed above well screen and at approximately 50-ft intervals to ground surface.
PVC well screen machine-slotted by manufacturer.
Well development activities conducted between 11/8/2013 through 11/10/2013.
Seep holes drilled into protective steel stick up cover upon completion of well installation.
AMEC Inspector Supervising Well Installation: _K_._L_Io~d ____________________ _
Static Water Level Elevation (NAVD88) collected December 9, 2013: _7_6_6_.8_9 ____________ _
Type of Locking Device:
Masterlock-Key A953 Type of Casing Protection: ___
S_t_e_e_l S_t_ic_k_U~p __ _
Concrete Surface Pad Dimensions:
2'x2'x0.5' DIAGRAM NOT TO SCALE ctive Steel Cover
- ~
4(
Top of Casing Elevation:
799.17 Prote Top of Concre te Elevation: 796.41 ~
Ground Surface ~
c---
c---~
~-- Ground Surface Elevation: 796.21
\\
v ng Seal I Grout Sea Casi M aterial: Cement-Bentonite Grout 4(
Bottom of Grout Seal I Top of Bentonite Seal Bent onite Seal r Pack Filte M aterial:
DSI NO. 2 Well Sand Well s
s T
s Screen creen Top Depth:
creen Top Elevation:
ype of Well Screen:
creen Opening Size:
36.8 759.4 PVC 0.020" Screen Bottom Depth:
56.8 Screen Bottom Elevation:
739.4 Clinch River Data Report Rev. 4 CRP-1112.16 Page E.1-38 of 46 Depth:
27.8 Elevation:
768.4 4(
Filter Pack Top Depth:
31.8 Elevation:
764.4 Well Casing Type:
PVC Size (diameter):
2" Schedule or Thickness:
SCH 40 57.3 J
Bottom Sump/Cap Depth:
60.0 Drilled Depth of Borehole:
14-(f--------l*~ Bore Hole Diameter:----'------
I I
6-8" AMEC Environment & Infrastructure, Inc.
Observation Well Data Sheet Prepared by/Date: MBL 4/29/14 Checked by/Date: WBD 4/29/14 Project Name: ___
Cc_L_I_N__c_C_H_R_IV_E_R_S_M_R_PR_O~JE_Cc_T----'--(A_M_E_C~64_6c_8_-_13'-----1 0_7_2_L_) __
County:
ROANE, TN Observation Weiii.D.: __
O_W_-4_2_9_L __
Date of Observation Well Installation:
10/10/13 Date of Well Development:
11/10/13 Observation Well Northing:
569965.3 US ft Easting:
2448576.5 US ft Observation Well Driller Observation Well Location:
Clinch River SMR Site Name:
G. Akins (M&W)
NOTES:
License No.:
TN #658 Observation well installed in accordance with ASTM D 5092-04(201 O)e1.
Northing and Easting =Tennessee State Plane Coordinates, NAD83, US Survey Feet.
Elevations = North American Vertical Datum of 1988 (NAVD88), Feet.
Depths/elevations referenced to surveyed ground surface.
Static water elevation referenced to mark on top of well casing.
Observation well drilled using air rotary techniques.
Steel centralizers installed above well screen and at approximately 50-ft intervals to ground surface.
PVC well screen machine-slotted by manufacturer.
Well development activities conducted between 11/8/2013 through 11/10/2013.
Seep holes drilled into protective steel stick up cover upon completion of well installation.
AMEC Inspector Supervising Well Installation: _K_._L_Io~d ____________________ _
Static Water Level Elevation (NAVD88) collected December 9, 2013: _6_4_0_.1_9 ____________ _
Type of Locking Device:
Masterlock-Key A953 Type of Casing Protection: ___
S_t_e_e_l S_t_ic_k_U~p __ _
Concrete Surface Pad Dimensions:
2'x2'x0.5' DIAGRAM NOT TO SCALE ctive Steel Cover
- ~
4(
Top of Casing Elevation:
799.49 Prote Top of Concre te Elevation: 796.52 ~
Ground Surface ~
c---
c---~
~-- Ground Surface Elevation: 796.26
\\
v ng Seal I Grout Sea Casi M aterial: Cement-Bentonite Grout 4(
Bottom of Grout Seal I Top of Bentonite Seal Bent onite Seal r Pack Filte M aterial:
DSI NO. 2 Well Sand Well s
s T
s Screen creen Top Depth:
creen Top Elevation:
ype of Well Screen:
creen Opening Size:
145.1 651.2 PVC 0.020" Screen Bottom Depth:
165.1 Screen Bottom Elevation:
631.2 Clinch River Data Report Rev. 4 CRP-1112.16 Page E.1-39 of 46 Depth:
136.1 Elevation:
660.2 4(
Filter Pack Top Depth:
140.1 Elevation:
656.2 Well Casing Type:
PVC Size (diameter):
2" Schedule or Thickness:
SCH 80 165.6 J
Bottom Sump/Cap Depth:
168.0 Drilled Depth of Borehole:
14-(f--------l*~ Bore Hole Diameter:----'------
I I
6-8" AMEC Environment & Infrastructure, Inc.
Observation Well Data Sheet Prepared by/Date: MBL 4/29/14 Checked by/Date: WBD 4/29/14 Project Name: ___
Cc_L_I_N__c_C_H_R_IV_E_R_S_M_R_PR_O~JE_Cc_T----'--(A_M_E_C~64_6c_8_-_13'-----1 0_7_2_L_) __
County:
ROANE, TN Observation Weiii.D.: __
P_T_-_O_W_-Uc_1 __
Date of Observation Well Installation:
10/9/13 Date of Well Development:
10/29/13 Observation Well Northing:
571512.5 US ft Easting:
2448235.3 US ft Observation Well Driller Observation Well Location:
Clinch River SMR Site Name:
G. Akins (M&W)
NOTES:
License No.:
TN #658 Observation well installed in accordance with ASTM D 5092-04(201 O)e1.
Northing and Easting =Tennessee State Plane Coordinates, NAD83, US Survey Feet.
Elevations = North American Vertical Datum of 1988 (NAVD88), Feet.
Depths/elevations referenced to surveyed ground surface.
Static water elevation referenced to mark on top of well casing.
Observation well drilled using air rotary techniques.
Steel centralizers installed above well screen and at approximately 50-ft intervals to ground surface.
PVC well screen machine-slotted by manufacturer.
Well development activities conducted between 10/28/2013 through 10/29/2013.
Seep holes drilled into protective steel stick up cover upon completion of well installation.
AMEC Inspector Supervising Well Installation: _K_._L_Io~d ____________________ _
Static Water Level Elevation (NAVD88) collected December 9, 2013: _7_5_0_.7_4 ____________ _
Type of Locking Device:
Masterlock-Key A953 Type of Casing Protection: ___
S_t_e_e_l S_t_ic_k_U~p __ _
Concrete Surface Pad Dimensions:
2'x2'x0.5' DIAGRAM NOT TO SCALE ctive Steel Cover
- ~
4(
Top of Casing Elevation:
801.52 Prote Top of Concre te Elevation: 798.71 ~
Ground Surface ~
c---
c---~
~-- Ground Surface Elevation: 798.55
\\
v ng Seal I Grout Sea Casi M aterial: Cement-Bentonite Grout 4(
Bottom of Grout Seal I Top of Bentonite Seal Bent onite Seal r Pack Filte M aterial:
DSI NO. 2 Well Sand Well s
s T
s Screen creen Top Depth:
creen Top Elevation:
ype of Well Screen:
creen Opening Size:
41.8 756.8 PVC 0.020" Screen Bottom Depth:
61.8 Screen Bottom Elevation:
736.8 Clinch River Data Report Rev. 4 CRP-1112.16 Page E.1-40 of 46 Depth:
19.8 Elevation:
778.8 4(
Filter Pack Top Depth:
36.8 Elevation:
761.8 Well Casing Type:
PVC Size (diameter):
2" Schedule or Thickness:
SCH 40 62.3 J
Bottom Sump/Cap Depth:
65.0 Drilled Depth of Borehole:
14-(f--------l*~ Bore Hole Diameter:----'------
I I
6-8" AMEC Environment & Infrastructure, Inc.
Observation Well Data Sheet Prepared by/Date: MBL 4/29/14 Checked by/Date: WBD 4/29/14 Project Name: ___
Cc_L_I_N__c_C_H_R_IV_E_R_S_M_R_PR_O~JE_Cc_T----'--(A_M_E_C~64_6c_8_-_13'-----1 0_7_2_L_) __
County:
ROANE, TN Observation Weiii.D.: __
PT_-_O_W_-L_1 __
Date of Observation Well Installation:
10/8/13 Date of Well Development:
10/28/13 Observation Well Northing:
571493.2 US ft Easting:
2448235.2 US ft Observation Well Driller Observation Well Location:
Clinch River SMR Site Name:
G. Akins (M&W)
NOTES:
License No.:
TN #658 Observation well installed in accordance with ASTM D 5092-04(201 O)e1.
Northing and Easting =Tennessee State Plane Coordinates, NAD83, US Survey Feet.
Elevations = North American Vertical Datum of 1988 (NAVD88), Feet.
Depths/elevations referenced to surveyed ground surface.
Static water elevation referenced to mark on top of well casing.
Observation well drilled using air rotary techniques.
Steel centralizers installed above well screen and at approximately 50-ft intervals to ground surface.
PVC well screen machine-slotted by manufacturer.
Well development activities conducted between 10/27/2013 through 10/28/2013.
Seep holes drilled into protective steel stick up cover upon completion of well installation.
AMEC Inspector Supervising Well Installation: _K_._L_Io~d ____________________ _
Static Water Level Elevation (NAVD88) collected December 9, 2013: _7_8_5_.6_7 ____________ _
Type of Locking Device:
Masterlock-Key A953 Type of Casing Protection: ___
S_t_e_e_l S_t_ic_k_U~p __ _
Concrete Surface Pad Dimensions:
2'x2'x0.5' DIAGRAM NOT TO SCALE ctive Steel Cover
- ~
4(
Top of Casing Elevation:
803.13 Prote Top of Concre te Elevation: 800.09 ~
Ground Surface ~
c---
c---~
~-- Ground Surface Elevation: 799.77
\\
v ng Seal I Grout Sea Casi M aterial: Cement-Bentonite Grout 4(
Bottom of Grout Seal I Top of Bentonite Seal Bent onite Seal r Pack Filte M aterial:
DSI NO. 2 Well Sand Well s
s T
s Screen creen Top Depth:
creen Top Elevation:
ype of Well Screen:
creen Opening Size:
139.7 660.1 PVC 0.020" Screen Bottom Depth:
159.7 Screen Bottom Elevation:
640.1 Clinch River Data Report Rev. 4 CRP-1112.16 Page E.1-41 of46 Depth:
129.7 Elevation:
670.1 4(
Filter Pack Top Depth:
134.9 Elevation:
664.9 Well Casing Type:
PVC Size (diameter):
2" Schedule or Thickness:
SCH 40 160.2 J
Bottom Sump/Cap Depth:
163.0 Drilled Depth of Borehole:
14-(f--------l*~ Bore Hole Diameter:----'------
I I
6-8" AMEC Environment & Infrastructure, Inc.
Observation Well Data Sheet Prepared by/Date: MBL 4/29/14 Checked by/Date: WBD 4/29/14 Project Name: ___
Cc_L_I_N__c_C_H_R_IV_E_R_S_M_R_PR_O~JE_Cc_T----'--(A_M_E_C~64_6c_8_-_13'-----1 0_7_2_L_) __
County:
ROANE, TN Observation Weiii.D.: __
P_T_-_O_W_-Uc_2 __
Date of Observation Well Installation:
10/9/13 Date of Well Development:
10/29/13 Observation Well Northing:
571489.5 US ft Easting:
2448182.4 US ft Observation Well Driller Observation Well Location:
Clinch River SMR Site Name:
B. Woods (M&W)
NOTES:
License No.:
TN #658 Observation well installed in accordance with ASTM D 5092-04(201 O)e1.
Northing and Easting =Tennessee State Plane Coordinates, NAD83, US Survey Feet.
Elevations = North American Vertical Datum of 1988 (NAVD88), Feet.
Depths/elevations referenced to surveyed ground surface.
Static water elevation referenced to mark on top of well casing.
Observation well drilled using air rotary techniques.
Steel centralizers installed above well screen and at approximately 50-ft intervals to ground surface.
PVC well screen machine-slotted by manufacturer.
Well development activities conducted between 10/27/2013 through 10/29/2013.
Seep holes drilled into protective steel stick up cover upon completion of well installation.
AMEC Inspector Supervising Well Installation: _N_._S_m_ith ____________________ _
Static Water Level Elevation (NAVD88) collected December 9, 2013: _7_5_0_.4_0 ____________ _
Type of Locking Device:
Masterlock-Key A953 Type of Casing Protection: ___
S_t_e_e_l S_t_ic_k_U~p __ _
Concrete Surface Pad Dimensions:
2'x2'x0.5' DIAGRAM NOT TO SCALE ctive Steel Cover
- ~
4(
Top of Casing Elevation:
805.31 Prote Top of Concre te Elevation: 802.60 ~
Ground Surface ~
c---
c---~
~-- Ground Surface Elevation: 802.19
\\
v ng Seal I Grout Sea Casi M aterial: Cement-Bentonite Grout 4(
Bottom of Grout Seal I Top of Bentonite Seal Bent onite Seal r Pack Filte M aterial:
DSI NO. 2 Well Sand Well s
s T
s Screen creen Top Depth:
creen Top Elevation:
ype of Well Screen:
creen Opening Size:
42.0 760.2 PVC 0.020" Screen Bottom Depth:
62.0 Screen Bottom Elevation:
7 40.2 Clinch River Data Report Rev. 4 CRP-1112.16 Page E.1-42 of 46 Depth:
32.9 Elevation:
769.3 4(
Filter Pack Top Depth:
37.0 Elevation:
765.2 Well Casing Type:
PVC Size (diameter):
2" Schedule or Thickness:
SCH 40 62.5 J
Bottom Sump/Cap Depth:
65.0 Drilled Depth of Borehole:
14-(f--------l*~ Bore Hole Diameter:----'------
I I
6-8" AMEC Environment & Infrastructure, Inc.
Observation Well Data Sheet Prepared by/Date: MBL 4/29/14 Checked by/Date: WBD 4/29/14 Project Name: ___
Cc_L_I_N__c_C_H_R_IV_E_R_S_M_R_PR_O~JE_Cc_T----'--(A_M_E_C~64_6c_8_-_13'-----1 0_7_2_L_) __
County:
ROANE, TN Observation Weiii.D.: __
PT_-_O_W_-L_2 __
Date of Observation Well Installation:
10/3/13 Date of Well Development:
10/10/13 Observation Well Northing:
571478.7 US ft Easting:
2448192.1 US ft Observation Well Driller Observation Well Location:
Clinch River SMR Site Name:
B. Woods (M&W)
NOTES:
License No.:
TN #658 Observation well installed in accordance with ASTM D 5092-04(201 O)e1.
Northing and Easting =Tennessee State Plane Coordinates, NAD83, US Survey Feet.
Elevations = North American Vertical Datum of 1988 (NAVD88), Feet.
Depths/elevations referenced to surveyed ground surface.
Static water elevation referenced to mark on top of well casing.
Observation well drilled using air rotary techniques.
Steel centralizers installed above well screen and at approximately 50-ft intervals to ground surface.
PVC well screen machine-slotted by manufacturer.
Well development activities conducted between 10/9/2013 through 10/10/2013.
Seep holes drilled into protective steel stick up cover upon completion of well installation.
AMEC Inspector Supervising Well Installation: _N_._S_m_ith ____________________ _
Static Water Level Elevation (NAVD88) collected December 9, 2013: _7_9_1_.4_9 ____________ _
Type of Locking Device:
Masterlock-Key A953 Type of Casing Protection: ___
S_t_e_e_l S_t_ic_k_U~p __ _
Concrete Surface Pad Dimensions:
2'x2'x0.5' DIAGRAM NOT TO SCALE ctive Steel Cover
- ~
4(
Top of Casing Elevation:
804.32 Prote Top of Concre te Elevation: 801.22 ~
Ground Surface ~
c---
c---~
~-- Ground Surface Elevation: 800.89
\\
v ng Seal I Grout Sea Casi M aterial: Cement-Bentonite Grout 4(
Bottom of Grout Seal I Top of Bentonite Seal Bent onite Seal r Pack Filte M aterial:
DSI NO. 2 Well Sand Well s
s T
s Screen creen Top Depth:
creen Top Elevation:
ype of Well Screen:
creen Opening Size:
139.8 661.1 PVC 0.020" Screen Bottom Depth:
159.8 Screen Bottom Elevation:
641.1 Clinch River Data Report Rev. 4 CRP-1112.16 Page E.1-43 of 46 Depth:
124.8 Elevation:
676.1 4(
Filter Pack Top Depth:
135.0 Elevation:
665.9 Well Casing Type:
PVC Size (diameter):
2" Schedule or Thickness:
SCH 40 160.3 J
Bottom Sump/Cap Depth:
163.0 Drilled Depth of Borehole:
14-(f--------l*~ Bore Hole Diameter:---'------
I I
6-10" AMEC Environment & Infrastructure, Inc.
Observation Well Data Sheet Prepared by/Date: MBL 4/29/14 Checked by/Date: WBD 4/29/14 Project Name: ___
Cc_L_I_N__c_C_H_R_IV_E_R_S_M_R_PR_O~JE_Cc_T----'--(A_M_E_C~64_6c_8_-_13'-----1 0_7_2_L_) __
County:
ROANE, TN Observation Weiii.D.: __ P_T_-_O_W_-U'---3'------
Date of Observation Well Installation:
10/9/13 Date of Well Development:
10/27/13 Observation Well Northing:
571418.4 US ft Easting:
2448310.6 US ft Observation Well Driller Observation Well Location:
Clinch River SMR Site Name:
B. Woods (M&W)
NOTES:
License No.:
TN #658 Observation well installed in accordance with ASTM D 5092-04(201 O)e1.
Northing and Easting =Tennessee State Plane Coordinates, NAD83, US Survey Feet.
Elevations = North American Vertical Datum of 1988 (NAVD88), Feet.
Depths/elevations referenced to surveyed ground surface.
Static water elevation referenced to mark on top of well casing.
Observation well drilled using air rotary techniques.
Steel centralizers installed above well screen and at approximately 50-ft intervals to ground surface.
PVC well screen machine-slotted by manufacturer.
Well development activities conducted between 10/26/2013 through 10/27/2013.
Seep holes drilled into protective steel stick up cover upon completion of well installation.
AMEC Inspector Supervising Well Installation: _N_._S_m_ith ____________________ _
Static Water Level Elevation (NAVD88) collected December 9, 2013: _7_7_5_.7_5 ____________ _
Type of Locking Device:
Masterlock-Key A953 Type of Casing Protection: ___
S_t_e_e_l S_t_ic_k_U~p __ _
Concrete Surface Pad Dimensions:
2'x2'x0.5' DIAGRAM NOT TO SCALE ctive Steel Cover
- ~
4(
Top of Casing Elevation:
801.65 Prote Top of Concre te Elevation: 799.31 ~
Ground Surface ~
c---
c---~
~-- Ground Surface Elevation:
799.17
\\
v ng Seal I Grout Sea Casi M aterial: Cement-Bentonite Grout 4(
Bottom of Grout Seal I Top of Bentonite Seal Bent onite Seal r Pack Filte M aterial:
DSI NO. 2 Well Sand Well s
s T
s Screen creen Top Depth:
creen Top Elevation:
ype of Well Screen:
creen Opening Size:
42.6 756.6 PVC 0.020" Screen Bottom Depth:
62.6 Screen Bottom Elevation:
736.6 Clinch River Data Report Rev. 4 CRP-1112.16 Page E.1-44 of 46 Depth:
24.6 Elevation:
774.6 4(
Filter Pack Top Depth:
34.1 Elevation:
765.1 Well Casing Type:
PVC Size (diameter):
2" Schedule or Thickness:
SCH 40 63.1 J
Bottom Sump/Cap Depth:
65.0 Drilled Depth of Borehole:
14-(f--------l*~ Bore Hole Diameter: _
____c __
I I
6" AMEC Environment & Infrastructure, Inc.
Observation Well Data Sheet Prepared by/Date: MBL 4/29/14 Checked by/Date: WBD 4/29/14 Project Name: ___
Cc_L_I_N__c_C_H_R_IV_E_R_S_M_R_PR_O~JE_Cc_T----'--(A_M_E_C~64_6c_8_-_13'-----1 0_7_2_L_) __
County:
ROANE, TN Observation Weiii.D.: __
PT_-_O_W_-L___c3 __
Date of Observation Well Installation:
10/8/13 Date of Well Development:
10/27/13 Observation Well Northing:
571420.6 US ft Easting:
2448290.2 US ft Observation Well Driller Observation Well Location:
Clinch River SMR Site Name:
B. Woods (M&W)
NOTES:
License No.:
TN #658 Observation well installed in accordance with ASTM D 5092-04(201 O)e1.
Northing and Easting =Tennessee State Plane Coordinates, NAD83, US Survey Feet.
Elevations = North American Vertical Datum of 1988 (NAVD88), Feet.
Depths/elevations referenced to surveyed ground surface.
Static water elevation referenced to mark on top of well casing.
Observation well drilled using air rotary techniques.
Steel centralizers installed above well screen and at approximately 50-ft intervals to ground surface.
PVC well screen machine-slotted by manufacturer.
Well development activities conducted between 10/11/2013 through 10/27/2013.
Seep holes drilled into protective steel stick up cover upon completion of well installation.
AMEC Inspector Supervising Well Installation: _N_._S_m_ith ____________________ _
Static Water Level Elevation (NAVD88) collected December 9, 2013: _7_4_5_.0_8 ____________ _
Type of Locking Device:
Masterlock-Key A953 Type of Casing Protection: ___
S_t_e_e_l S_t_ic_k_U~p __ _
Concrete Surface Pad Dimensions:
2'x2'x0.5' DIAGRAM NOT TO SCALE ctive Steel Cover
- ~
4(
Top of Casing Elevation:
803.12 Prote Top of Concre te Elevation: 800.41 ~
Ground Surface ~
c---
c---~
~-- Ground Surface Elevation:
800.07
\\
v ng Seal I Grout Sea Casi M aterial: Cement-Bentonite Grout 4(
Bottom of Grout Seal I Top of Bentonite Seal Bent onite Seal r Pack Filte M aterial:
DSI NO. 2 Well Sand Well s
s T
s Screen creen Top Depth:
creen Top Elevation:
ype of Well Screen:
creen Opening Size:
140.5 659.6 PVC 0.020" Screen Bottom Depth:
160.5 Screen Bottom Elevation:
639.6 Clinch River Data Report Rev. 4 CRP-1112.16 Page E.1-45 of 46 Depth:
127.5 Elevation:
672.6 4(
Filter Pack Top Depth:
135.5 Elevation:
664.6 Well Casing Type:
PVC Size (diameter):
2" Schedule or Thickness:
SCH 40 161.0 J
Bottom Sump/Cap Depth:
163.0 Drilled Depth of Borehole:
14-(f--------l*~ Bore Hole Diameter: _
____c __
I I
6" AMEC Environment & Infrastructure, Inc.
Observation Well Data Sheet Prepared by/Date: MBL 4/29/14 Checked by/Date: WBD 4/29/14 Project Name: ___
Cc_L_I_N__c_C_H_R_IV_E_R_S_M_R_PR_O~JE_Cc_T----'--(A_M_E_C~64_6c_8_-_13'-----1 0_7_2_L_) __
County:
ROANE, TN Observation Weiii.D.: ___
P_T_-P_W __ _
Date of Observation Well Installation:
10/1/13 Date of Well Development:
10/11/13 Observation Well Northing:
571432.2 US ft Easting:
2448229.1 US ft Observation Well Driller Observation Well Location:
Clinch River SMR Site Name:
B. Woods (M&W)
NOTES:
License No.:
TN #658 Observation well installed in accordance with ASTM D 5092-04(201 O)e1.
Northing and Easting =Tennessee State Plane Coordinates, NAD83, US Survey Feet.
Elevations = North American Vertical Datum of 1988 (NAVD88), Feet.
Depths/elevations referenced to surveyed ground surface.
Static water elevation referenced to mark on top of well casing.
Observation well drilled using air rotary techniques.
Steel centralizers installed above well screen and at approximately 50-ft intervals to ground surface.
PVC well screen machine-slotted by manufacturer.
Well development conducted between 10/1/2013-10/2/2013 during installation; redeveloped 10/3/2013-10/11/2013.
Seep holes drilled into protective steel stick up cover upon completion of well installation.
- 1. Filter Pack Material: DSI NO.2 Well Sand (34.6-74.7 feet) and DSI NO.3 Well Sand (74.7-173.0 feet).
AMEC Inspector Supervising Well Installation: _N_._S_m_ith ____________________ _
Static Water Level Elevation (NAVD88) collected December 9, 2013: _7_4_1_.3_6 ____________ _
Type of Locking Device:
Masterlock-Key A953 Type of Casing Protection: ___
S_t_e_e_l S_t_ic_k_U~p __ _
Concrete Surface Pad Dimensions:
2'x2'x0.5' DIAGRAM NOT TO SCALE Prote ctive Steel Cover
- ~
Top of Concre te Elevation: 802.41 ~
Ground Surface ~
c---
Casi ng Seal I Grout Sea M aterial: Cement-Bentonite Grout Bent onite Seal r Pack Filte M aterial:
See Note 1.
Well s
s T
s Screen creen Top Depth:
creen Top Elevation:
ype of Well Screen:
creen Opening Size:
39.3 762.8 PVC 0.020"
\\
4(
c---~
v 4(
4(
J.......,
Top of Casing Elevation:
804.03
~-- Ground Surface Elevation: 802.06 Bottom of Grout Seal I Top of Bentonite Seal Depth:
29.4 Elevation:
772.7 Filter Pack Top Depth:
34.6 Elevation:
767.5 Well Casing Type:
PVC Size (diameter):
6" Schedule or Thickness:
SCH 40 Bottom Sump/Cap Depth:
171.8 Drilled Depth of Borehole:
173.0 Screen Bottom Depth:
169.3 Screen Bottom Elevation:
632.8 141-(f--------l*~~ Bore Hole Diameter:
10"-12" Clinch River Data Report Rev. 4 CRP-1112.16 Page E.1-46 of 46 AMEC Environment & Infrastructure, Inc.