ML18003A825
| ML18003A825 | |
| Person / Time | |
|---|---|
| Site: | Clinch River |
| Issue date: | 12/15/2017 |
| From: | James Shea Tennessee Valley Authority |
| To: | Office of New Reactors |
| Fetter A | |
| References | |
| TVACLINCHRIVERESP, TVACLINCHRIVERESP.SUBMISSION.4, CRN.P.PART08, CRN.P.PART08.1 | |
| Download: ML18003A825 (12) | |
Text
AMEC Environmental & Infrastructure, Inc.
Clinch River SMR Project MP-213 AMEC Project 6468-13-1072
-N151 28 Primary-structure Planar Bedding
-N153 26 Primary-structure Planar Bedding
-N154 25 Primary-structure Planar Bedding 39.448 to 32.080f1 AMEC Clinch River SMR Project Borehole MP-213 Acoustic Televiewer Features rev 2 Sheet 4 of23 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-988 of 1849 January 11, 2014 Page 986 of 1847 RCN: CRP-111 0.0 4
AMEC Environmental & Infrastructure, Inc.
Clinch River SMR Project MP-213 46.816 to 39.448f1 AMEC Project 6468-13-1072
-N140 28 Primary-structure Planar Bedding
-N335 52 Fracture Planar Hairline-fracture
-N155 24 Primary-structure Planar Bedding
-N151 18 Primary-structure Planar Bedding
-N143 25 Primary-structure Planar Bedding
-N336 67 Fracture Discontinuous Hairline-fractun 5
AMEC Clinch River SMR Project Borehole MP-213 Acoustic Televiewer Features rev 2 Sheet 5 of23 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-989 of 1849 January 11, 2014 Page 987 of 1847 RCN: CRP-111 0.0
AMEC Environmental & Infrastructure, Inc.
Clinch River SMR Project
- 47.
- 48.
- 49.
- 50.
- 51.
- 52.
- 53.
- 54.
MP-213 54.184 to 46.816f1 AMEC Project 6468-13-1072
-N148 25 Primary-structure Planar Bedding
-N142 24 Primary-structure Planar Bedding
-N145 34 Primary-structure Planar Bedding
,N324 57 Fracture Discontinuous Hairline-fractun
-N156 23 Primary-structure Planar Bedding
-N153 23 Primary-structure Planar Bedding
-N147 24 Primary-structure Planar Bedding
-N156 20 Primary-structure Planar Bedding 6
AMEC Clinch River SMR Project Borehole MP-213 Acoustic Televiewer Features rev 2 Sheet 6 of23 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-990 of 1849 January 11, 2014 Page 988 of 1847 RCN: CRP-111 0.0
AMEC Environmental & Infrastructure, Inc.
Clinch River SMR Project
- 55.
- 56.
- 57.
- 58.
- 59.
- 60.
- 61.
MP-213 61.552 to 54.184f1 AMEC Project 6468-13-1072
-N148 25 Primary-structure Planar Bedding
-N151 26 Primary-structure Planar Bedding
-N150 25 Primary-structure Planar Bedding
-N146 22 Primary-structure Planar Bedding
-N334 71 Fracture Discontinuous Hairline-fractun
-N152 19 Primary-structure Planar Bedding
-N144 27 Primary-structure Planar Bedding
-N139 28 Primary-structure Planar Beddinq 7
AMEC Clinch River SMR Project Borehole MP-213 Acoustic Televiewer Features rev 2 Sheet 7 of23 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-991 of 1849 January 11, 2014 Page 989 of 1847 RCN: CRP-111 0.0
AMEC Environmental & Infrastructure, Inc.
Clinch River SMR Project MP-213 68.920 to 61.552f1 AMEC Project 6468-13-1072
-N145 29 Primary-structure Planar Bedding
-N152 27 Primary-structure Planar Bedding
-N096 29 Fracture Planar Hairline-fracture
-N158 24 Primary-structure Planar Bedding AMEC Clinch River SMR Project Borehole MP-213 Acoustic Televiewer Features rev 2 Sheet 8 of23 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-992 of 1849 January 11, 2014 Page 990 of 1847 RCN: CRP-111 0.0 8
AMEC Environmental & Infrastructure, Inc.
Clinch River SMR Project MP-213 76.288 to 68.920f1 AMEC Project 6468-13-1072
-N144 25 Primary-structure Planar Bedding
-N335 66 Fracture Discontinuous Hairline-fractun
-N149 24 Primary-structure Planar Bedding
-N141 22 Primary-structure Planar Bedding
-N145 26 Primary-structure Planar Bedding
-N152 24 Primary-structure Planar Bedding
-Change in ATV gain
-N156 21 Primary-structure Planar Bedding
-N334 59 Fracture Discontinuous Hairline-fractun
-N148 21 Primary-structure Planar Bedding
-N149 22 Primary-structure Planar Bedding 9
AMEC Clinch River SMR Project Borehole MP-213 Acoustic Televiewer Features rev 2 Sheet 9 of23 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-993 of 1849 January 11, 2014 Page 991 of 1847 RCN: CRP-111 0.0
AMEC Environmental & Infrastructure, Inc.
Clinch River SMR Project MP-213 83.656 to 76.288f1 AMEC Project 6468-13-1072
-N145 27 Primary-structure Planar Bedding
-N160 24 Primary-structure Planar Bedding
-N143 28 Primary-structure Planar Bedding
-N144 26 Primary-structure Planar Bedding
-N136 23 Primary-structure Planar Bedding
-N151 26 Primary-structure Planar Bedding
-N152 22 Primary-structure Planar Bedding
-N151 24 Primary-structure Planar Bedding
-N333 55 Fracture Discontinuous Hairline-fractun tN140 26 Prim~rv-structure Pl~n~r Beddina 10 AMEC Clinch River SMR Project Borehole MP-213 Acoustic Televiewer Features rev 2 Sheet 10 of 23 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-994 of 1849 January 11, 2014 Page 992 of 1847 RCN: CRP-111 0.0
AMEC Environmental & Infrastructure, Inc.
Clinch River SMR Project
- ~ 1 "'\\l AMEC Project 6468-13-1072
1 ~
-N140 26 Primary-structure Planar Bedding
~
~ ~
\\J.
1-*--+-
-c-'
+ --- -- **H --*+- + + +- +--1--1-+l-- ---------
-N156 24 Primary-structure Planar Bedding
\\---------
. -N147 27 Primary-structure Planar Bedding I\\
\\
t-fl
'I I
~
I
-N148 28 Primary-structure Planar Bedding t--f-H*-- :-f!iH:t-+***-*----+ t--*+--+-.JI-\\-+1-"-+,*++++-:::::::::.;*=
~
~r
~... \\
-N311 55 Fracture Discontinuous Hairline-fractun
~
-N340 58 Fracture Discontinuous Hairline-fractun
-
~
~
~
~
1*/
1.--"
..... iiL...:.L.
-N146 23 Primary-structure Planar Bedding liO,.---~+--+---+~--f--+--+-++++ J-
\\ i..=-~
~.. --.;
IV
.* t
~ ~
~
t, ~-lj
- r.~ !
~-
- \\
~
-N152 23 Primary-structure Planar Bedding r-------------- ~
-N160 21 Primary-structure Planar Bedding
\\**-**-**-**-**-**-
- N341 80 Fracture Planar Hairline-fracture
-N149 23 Primary-structure Planar Bedding
-N332 58 Fracture Discontinuous Hairline-fractun
~-
~ -- -
I-
-N155 24 Primary-structure Planar Bedding
... p-11 MP-213 91.024 to 83.656f1 AMEC Clinch River SMR Project Borehole MP-213 Acoustic Televiewer Features rev 2 Sheet 11 of 23 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-995 of 1849 January 11, 2014 Page 993 of 1847 RCN: CRP-111 0.0 11
AMEC Environmental & Infrastructure, Inc.
Clinch River SMR Project MP-213 98.392 to 91.024f1 AMEC Project 6468-13-1072
-N156 23 Primary-structure Planar Bedding
-N339 51 Fracture Discontinuous Hairline-fractun
-N161 43 Primary-structure Planar Bedding
-N331 52 Fracture Discontinuous Hairline-fractun
-N159 31 Primary-structure Planar Bedding
- N332 57 Fracture Discontinuous Hairline-fractun
-N164 15 Primary-structure Planar Bedding 12 AMEC Clinch River SMR Project Borehole MP-213 Acoustic Televiewer Features rev 2 Sheet 12 of 23 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-996 of 1849 January 11, 2014 Page 994 of 1847 RCN: CRP-111 0.0
AMEC Environmental & Infrastructure, Inc.
Clinch River SMR Project 99.0 100.0 101.0 102.0 103.0 104.0 105.0 AMEC Project 6468-13-1072
-N156 23 Primary-structure Planar Bedding
-N145 21 Primary-structure Planar Bedding
-N147 22 Primary-structure Planar Bedding
-N145 20 Primary-structure Planar Bedding
-N150 22 Primary-structure Planar Bedding
-N151 27 Primary-structure Planar Bedding
-N156 22 Primary-structure Planar Bedding
-N161 25 Primary-structure Planar Bedding MP-213 105.760 to 98.392f1 AMEC Clinch River SMR Project Borehole MP-213 Acoustic Televiewer Features rev 2 Sheet 13 of 23 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page 995 of 1847 RCN: CRP-111 0.0 Page C1-997 of 1849 13
AMEC Environmental & Infrastructure, Inc.
Clinch River SMR Project 106.
107.
108.
109.
110.
111.
112.
113.
AMEC Project 6468-13-1072
-N151 23 Primary-structure Planar Bedding
-N146 21 Primary-structure Planar Bedding
-N149 26 Primary-structure Planar Bedding
-N149 22 Primary-structure Planar Bedding
-N139 25 Primary-structure Planar Bedding
-N162 24 Primary-structure Planar Bedding
-N146 25 Primary-structure Planar Bedding
-N153 24 Primary-structure Planar Bedding MP-213 113.128to 105.760ft AMEC Clinch River SMR Project Borehole MP-213 Acoustic Televiewer Features rev 2 Sheet 14 of 23 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page 996 of 1847 RCN: CRP-111 0.0 Page C1-998 of 1849 14
AMEC Environmental & Infrastructure, Inc.
Clinch River SMR Project 114.0 115.0 116.0 117.0 118.0 119.0 120.0 AMEC Project 6468-13-1072
-N333 72 Fracture Discontinuous Hairline-fractun
-N152 27 Primary-structure Planar Bedding
-N154 24 Primary-structure Planar Bedding
-N149 20 Primary-structure Planar Bedding
-N328 75 Fracture Discontinuous Hairline-fractun MP-213 120.496 to 113.128ft 15 AMEC Clinch River SMR Project Borehole MP-213 Acoustic Televiewer Features rev 2 Sheet 15 of 23 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page 997 of 1847 RCN: CRP-111 0.0 Page C1-999 of 1849