AMEC Environmental & Infrastructure, Inc.
Clinch River SMR Project 121.
122.
123.
124.
125.
126.
127.
MP-212 127.892 to 120.524ft AMEC Project 6468-13-1072
-N142 35 Primary-structure Planar Bedding
-N135 73 Fracture Discontinuous Hairline-fractun
-N143 32 Primary-structure Planar Bedding
-N321 73 Fracture Discontinuous Hairline-fractun
-N148 31 Fracture Planar Hairline-fracture
-N140 34 Primary-structure Planar Bedding 12 AMEC Clinch River SMR Project Borehole MP-212 Acoustic Televiewer Features rev 2 Sheet 12 of 19 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-977 of 1849 January 11, 2014 Page 975 of 1847 RCN: CRP-111 0.0
AMEC Environmental & Infrastructure, Inc.
Clinch River SMR Project 134.0 135.0 AMEC Project 6468-13-1072
-N146 30 Primary-structure Planar Bedding
-N146 26 Primary-structure Planar Bedding
-N131 33 Primary-structure Planar Bedding
-N149 31 Primary-structure Planar Bedding
-N154 33 Primary-structure Planar Bedding
-N338 60 Fracture Planar Hairline-fracture
-N135 33 Primary-structure Planar Bedding
-N151 33 Primary-structure Planar Bedding
-N322 76 Fracture Planar Hairline-fracture
-N147 30 Primary-structure Planar Bedding
-N141 31 Primary-structure Planar Bedding
.---N349 60 Fr~cture Pl~n~r H~irline-fr~cture MP-212 135.260to 127.892ft AMEC Clinch River SMR Project Borehole MP-212 Acoustic Televiewer Features rev 2 Sheet 13 of 19 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page 976 of 1847 RCN: CRP-111 0.0 Page C1-978 of 1849 13
AMEC Environmental & Infrastructure, Inc.
Clinch River SMR Project 136.
137.
138.
139.
140.
141.
142.
AMEC Project 6468-13-1072
-N153 31 Primary-structure Planar Bedding
-N330 54 Fracture Planar Hairline-fracture
-N141 29 Primary-structure Planar Bedding
-N325 46 Fracture Planar Hairline-fracture
~~ -N126 39 Primary-structure Planar Bedding
-N138 32 Primary-structure Planar Bedding
-N321 50 Fracture Planar Hairline-fracture
-N151 34 Primary-structure Planar Bedding
-N328 71 Fracture Discontinuous Hairline-fractun
-N138 30 Primary-structure Planar Bedding
-N316 66 Fracture Discontinuous Hairline-fractun
-N149 32 Primary-structure Planar Bedding
-N335 54 Fracture Planar Hairline-fracture
-N149 31 Primary-structure Planar Bedding MP-212 142.628to 135.260ft 14 AMEC Clinch River SMR Project Borehole MP-212 Acoustic Televiewer Features rev 2 Sheet 14 of 19 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page 977 of 1847 RCN: CRP-111 0.0 Page C1-979 of 1849
AMEC Environmental & Infrastructure, Inc.
Clinch River SMR Project 143.
144.
145.
146.
147.
148.
149.
AMEC Project 6468-13-1072
-N140 27 Primary-structure Planar Bedding
-N146 33 Primary-structure Planar Bedding
-N145 30 Primary-structure Planar Bedding
-N332 49 Fracture Planar Hairline-fracture
-N149 33 Primary-structure Planar Bedding
-N138 30 Primary-structure Planar Bedding
-N143 31 Primary-structure Planar Bedding
-N155 26 Primary-structure Planar Bedding
-N143 49 Fracture Planar Hairline-fracture
-N159 37 Primary-structure Planar Bedding
-N140 39 Primary-structure Planar Bedding MP-212 149.996 to 142.628ft AMEC Clinch River SMR Project Borehole MP-212 Acoustic Televiewer Features rev 2 Sheet 15 of 19 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page 978 of 1847 RCN: CRP-111 0.0 Page C1-980 of 1849 15
AMEC Environmental & Infrastructure, Inc.
Clinch River SMR Project AMEC Project 6468-13-1072
-N145 28 Primary-structure Planar Bedding
-N130 33 Primary-structure Planar Bedding
-N135 33 Primary-structure Planar Bedding
-N141 29 Primary-structure Planar Bedding
-N139 34 Primary-structure Planar Bedding
-N142 30 Primary-structure Planar Bedding
-N139 31 Primary-structure Planar Bedding
-N134 31 Prim~rv-structure Pl~n~r Beddina MP-212 157.364to 149.996ft AMEC Clinch River SMR Project Borehole MP-212 Acoustic Televiewer Features rev 2 Sheet 16 of 19 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page 979 of 1847 RCN: CRP-111 0.0 Page C1-981 of 1849 16
AMEC Environmental & Infrastructure, Inc.
Clinch River SMR Project AMEC Project 6468-13-1072
-N155 32 Primary-structure Planar Bedding
-N325 64 Fracture Planar Hairline-fracture
-N142 33 Primary-structure Planar Bedding
-N157 37 Primary-structure Planar Bedding
-N006 57 Fracture Discontinuous Hairline-fractun
-N140 25 Primary-structure Planar Bedding
-N147 31 Primary-structure Planar Bedding
-N150 30 Primary-structure Planar Bedding
-N147 29 Primary-structure Planar Bedding
-N148 27 Primary-structure Planar Bedding
-N152 30 Primary-structure Planar Bedding MP-212 164.732 to 157.364ft AMEC Clinch River SMR Project Borehole MP-212 Acoustic Televiewer Features rev 2 Sheet 17 of 19 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page 980 of 1847 RCN: CRP-111 0.0 Page C1-982 of 1849 17
AMEC Environmental & Infrastructure, Inc.
Clinch River SMR Project AMEC Project 6468-13-1072
-N151 27 Primary-structure Planar Bedding
-N142 30 Primary-structure Planar Bedding
-N146 25 Primary-structure Planar Bedding
-N129 28 Primary-structure Planar Bedding
-N152 26 Primary-structure Planar Bedding
-N143 25 Primary-structure Planar Bedding
-N149 27 Primary-structure Planar Bedding
-N149 25 Primary-structure Planar Bedding
-N141 26 Primary-structure Planar Bedding
-N140 29 Primary-structure Planar Bedding
-N153 30 Primary-structure Planar Beddinq MP-212 172.100to 164.732ft AMEC Clinch River SMR Project Borehole MP-212 Acoustic Televiewer Features rev 2 Sheet 18 of 19 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page 981 of 1847 RCN: CRP-111 0.0 Page C1-983 of 1849 18
AMEC Environmental & Infrastructure, Inc.
Clinch River SMR Project 173.0 174.0 175.0 176.0 AMEC Project 6468-13-1072
-N136 31 Primary-structure Planar Bedding
-N148 27 Primary-structure Planar Bedding
-N144 27 Primary-structure Planar Bedding
-N141 27 Primary-structure Planar Bedding
-N142 28 Primary-structure Planar Bedding MP-212 176.548 to 172.1 OOft AMEC Clinch River SMR Project Borehole MP-212 Acoustic Televiewer Features rev 2 Sheet 19 of 19 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page 982 of 1847 RCN: CRP-111 0.0 Page C1-984 of 1849 19
AMEC Environmental & Infrastructure, Inc.
Clinch River SMR Project G~Ms,!on BHTV DATA PROCESSING RGLDIP vsn 6.2 geophysical services INTERPRETED BHTV DIPS LOG AMEC Borehole: MP-213 CLINCH RIVER top of borehole.....
East: -
North:_
Elev: -
Zone from 175.616 to 13.5001!
Format: BHTV-NESWN Stratigraphic dips ARROW PLOT AMEC Project 6468-13-1072 North ref. is true Depth units are feet Vertical scale: 1/10 Horiz scale = 1.00x Vert scale Borehole diam: 3.900inch Vertical = borehole-axis Image: Amplitude Identified units COMMENTS N315o N45o 20° 60° 90°------7 ------7
-Image degradation due to air bubbles
-caused by water flow into borehole
-bottom of steel casing MP-213 17.344 to 13.500f1 AMEC Clinch River SMR Project Borehole MP-213 Acoustic Televiewer Features rev 2 Sheet 1 of 23 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-985 of 1849 January 11, 2014 Page 983 of 1847 RCN: CRP-111 0.0
AMEC Environmental & Infrastructure, Inc.
Clinch River SMR Project MP-213 24.712 to 17.344f1 AMEC Project 6468-13-1072
-N326 39 Fracture Planar Open-fracture
-N333 53 Fracture Planar Open-fracture
-N150 22 Primary-structure Planar Bedding
-N329 70 Fracture Discontinuous Hairline-fractun
-N306 48 Fracture Discontinuous Hairline-fractun
-N333 69 Fracture Discontinuous Hairline-fractun
-N146 24 Primary-structure Planar Bedding
-N142 23 Primary-structure Planar Bedding
-N331 66 Fracture Discontinuous Hairline-fractun
-N328 42 Fracture Planar Hairline-fracture
-N327 71 Fracture Discontinuous Hairline-fractun 2
AMEC Clinch River SMR Project Borehole MP-213 Acoustic Televiewer Features rev 2 Sheet 2 of23 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-986 of 1849 January 11, 2014 Page 984 of 1847 RCN: CRP-111 0.0
AMEC Environmental & Infrastructure, Inc.
Clinch River SMR Project MP-213 32.080 to 24.712f1 AMEC Project 6468-13-1072
-N329 69 Fracture Discontinuous Hairline-fractun
-N149 27 Primary-structure Planar Bedding
-N149 23 Primary-structure Planar Bedding
- N331 43 Fracture Discontinuous Hairline-fractun
-N149 29 Primary-structure Planar Bedding
-N148 27 Primary-structure Planar Bedding
-N151 30 Primary-structure Planar Bedding
-N347 75 Fracture Discontinuous Hairline-fractun
-N151 29 Primary-structure Planar Bedding
-N341 48 Fracture Planar Hairline-fracture
-N128 28 Primary-structure Planar Bedding 3
AMEC Clinch River SMR Project Borehole MP-213 Acoustic Televiewer Features rev 2 Sheet 3 of23 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-987 of 1849 January 11, 2014 Page 985 of 1847 RCN: CRP-111 0.0