ML18003A821
| ML18003A821 | |
| Person / Time | |
|---|---|
| Site: | Clinch River |
| Issue date: | 12/15/2017 |
| From: | James Shea Tennessee Valley Authority |
| To: | Office of New Reactors |
| Fetter A | |
| References | |
| TVACLINCHRIVERESP, TVACLINCHRIVERESP.SUBMISSION.4, CRN.P.PART08, CRN.P.PART08.1 | |
| Download: ML18003A821 (11) | |
Text
AMEC Environmental & Infrastructure, Inc.
Clinch River SMR Project G~Ms,!on BHTV DATA PROCESSING RGLDIP vsn 6.2 geophysical services INTERPRETED BHTV DIPS LOG AMEC Borehole: MP-212 CLINCH RIVER top of borehole.....
East: -
North:_
Elev: -
Zone from 176.548 to 43.0001!
Format: BHTV-NESWN Stratigraphic dips ARROW PLOT AMEC Project 6468-13-1072 North ref. is true Depth units are feet Vertical scale: 1/10 Horiz scale = 1.00x Vert scale Borehole diam: 3.900inch Vertical = borehole-axis Image: Amplitude Identified units COMMENTS N315o N45o N
E s
w 20° 60° 90°------7 ------7
-bottom of steel casing
-N142 32 Primary-structure Planar Bedding
-N325 60 Fracture Discontinuous Hairline-fractun MP-212 46.844 to 43.000f1 AMEC Clinch River SMR Project Borehole MP-212 Acoustic Televiewer Features rev 2 Sheet 1 of 19 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-966 of 1849 January 11, 2014 Page 964 of 1847 RCN: CRP-111 0.0
AMEC Environmental & Infrastructure, Inc.
Clinch River SMR Project MP-212 54.212 to 46.844f1 AMEC Project 6468-13-1072
-N303 53 Fracture Planar Hairline-fracture
-N147 33 Primary-structure Planar Bedding
-N159 35 Primary-structure Planar Bedding
-N145 33 Primary-structure Planar Bedding
-N200 36 Fracture Planar Hairline-fracture
-N144 33 Primary-structure Planar Bedding
-N311 62 Fracture Discontinuous Hairline-fractun
-N146 33 Primary-structure Planar Bedding
-N145 33 Primary-structure Planar Bedding
-N147 32 Primary-structure Planar Bedding
-N143 32 Primary-structure Planar Bedding
-N144 32 Primary-structure Planar Bedding
-N143 33 Primary-structure Planar Bedding 2
AMEC Clinch River SMR Project Borehole MP-212 Acoustic Televiewer Features rev 2 Sheet 2 of 19 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-967 of 1849 January 11, 2014 Page 965 of 1847 RCN: CRP-111 0.0
AMEC Environmental & Infrastructure, Inc.
Clinch River SMR Project 55.0 56.0 57.0 58.0 59.0 60.0 61.0 MP-212 61.580 to 54.212f1 AMEC Project 6468-13-1072
-N154 29 Primary-structure Planar Bedding
-N336 64 Fracture Planar Hairline-fracture
-N321 61 Fracture Planar Hairline-fracture
-N142 32 Primary-structure Planar Bedding
-N341 41 Fracture Planar Hairline-fracture
-N151 29 Primary-structure Planar Bedding
- N147 31 Primary-structure Planar Bedding
-N328 56 Fracture Discontinuous Hairline-fractun
-N151 32 Primary-structure Planar Bedding
-N141 33 Primary-structure Planar Bedding
-N139 29 Primary-structure Planar Bedding 3
AMEC Clinch River SMR Project Borehole MP-212 Acoustic Televiewer Features rev 2 Sheet 3 of 19 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-968 of 1849 January 11, 2014 Page 966 of 1847 RCN: CRP-111 0.0
AMEC Environmental & Infrastructure, Inc.
Clinch River SMR Project MP-212 68.948 to 61.580f1 AMEC Project 6468-13-1072
-N331 56 Fracture Planar Hairline-fracture
-N149 34 Primary-structure Planar Bedding
-N147 30 Primary-structure Planar Bedding
-N140 31 Primary-structure Planar Bedding
-N324 68 Fracture Planar Hairline-fracture
-N146 33 Primary-structure Planar Bedding
-N336 57 Fracture Planar Hairline-fracture
-N156 27 Primary-structure Planar Bedding
-N335 44 Fracture Planar Hairline-fracture
-N136 39 Primary-structure Planar Bedding
-N142 31 Primary-structure Planar Bedding
-N145 30 Primary-structure Planar Bedding AMEC Clinch River SMR Project Borehole MP-212 Acoustic Televiewer Features rev 2 Sheet 4 of 19 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-969 of 1849 January 11, 2014 Page 967 of 1847 RCN: CRP-111 0.0 4
AMEC Environmental & Infrastructure, Inc.
Clinch River SMR Project 72.0 73.0 74.0 75.0 76.0 MP-212 AMEC Project 6468-13-1072
-N147 29 Primary-structure Planar Bedding
-N144 30 Primary-structure Planar Bedding
-N144 30 Primary-structure Planar Bedding
-N148 30 Primary-structure Planar Bedding
-N149 31 Primary-structure Planar Bedding
-N141 32 Primary-structure Planar Bedding
-N148 32 Primary-structure Planar Bedding
-N155 36 Primary-structure Planar Bedding
-N346 55 Fracture Planar Hairline-fracture 76.316 to 68.948f1 AMEC Clinch River SMR Project Borehole MP-212 Acoustic Televiewer Features rev 2 Sheet 5 of 19 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-970 of 1849 January 11, 2014 Page 968 of 1847 RCN: CRP-111 0.0 5
AMEC Environmental & Infrastructure, Inc.
Clinch River SMR Project 77.0 78.0 79.0 80.0 81.0 83.0 MP-212 83.684 to 76.316f1 AMEC Project 6468-13-1072
- N141 32 Primary-structure Planar Bedding
-N332 34 Fracture Planar Hairline-fracture
-N145 30 Primary-structure Planar Bedding
-N145 31 Primary-structure Planar Bedding
-N327 46 Fracture Planar Hairline-fracture
-N139 33 Primary-structure Planar Bedding
-N143 32 Primary-structure Planar Bedding
-N143 31 Primary-structure Planar Bedding AMEC Clinch River SMR Project Borehole MP-212 Acoustic Televiewer Features rev 2 Sheet 6 of 19 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-971 of 1849 January 11, 2014 Page 969 of 1847 RCN: CRP-111 0.0 6
AMEC Environmental & Infrastructure, Inc.
Clinch River SMR Project 84.0 85.0 86.0 87.0 88.0 89.0
\\
90.0 91.0 MP-212 AMEC Project 6468-13-1072
-N134 29 Primary-structure Planar Bedding
-N145 30 Primary-structure Planar Bedding
-N274 77 Fracture Planar Hairline-fracture
-N142 33 Primary-structure Planar Bedding
-N206 74 Fracture Discontinuous Hairline-fractun
-N331 45 Fracture Discontinuous Hairline-fractun
-N130 33 Primary-structure Planar Bedding
-N146 29 Primary-structure Planar Bedding
-N151 31 Primary-structure Planar Bedding
-N153 29 Primary-structure Planar Bedding
-N333 67 Fracture Discontinuous Hairline-fractun
-N141 37 Primary-structure Planar Bedding 91.052 to 83.684f1 7
AMEC Clinch River SMR Project Borehole MP-212 Acoustic Televiewer Features rev 2 Sheet 7 of 19 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-972 of 1849 January 11, 2014 Page 970 of 1847 RCN: CRP-111 0.0
AMEC Environmental & Infrastructure, Inc.
Clinch River SMR Project MP-212 98.420 to 91.052f1 AMEC Project 6468-13-1072
-N137 38 Primary-structure Planar Bedding
-N150 31 Primary-structure Planar Bedding
-N324 66 Fracture Discontinuous Hairline-fractun
.--N152 28 Primary-structure Planar Bedding
-N342 78 Fracture Discontinuous Hairline-fractun
-N148 29 Primary-structure Planar Bedding
-N321 71 Fracture Planar Hairline-fracture
-N139 30 Primary-structure Planar Bedding
-N144 33 Primary-structure Planar Bedding
-N329 51 Fracture Planar Hairline-fracture
-N158 36 Primary-structure Planar Bedding 8
AMEC Clinch River SMR Project Borehole MP-212 Acoustic Televiewer Features rev 2 Sheet 8 of 19 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-973 of 1849 January 11, 2014 Page 971 of 1847 RCN: CRP-111 0.0
AMEC Environmental & Infrastructure, Inc.
Clinch River SMR Project AMEC Project 6468-13-1072
-N145 38 Primary-structure Planar Bedding
-N150 28 Primary-structure Planar Bedding
-N149 32 Primary-structure Planar Bedding
-N338 44 Fracture Planar Hairline-fracture
-N146 39 Primary-structure Planar Bedding
-N143 31 Primary-structure Planar Bedding
-N140 30 Primary-structure Planar Bedding
-N142 29 Primary-structure Planar Bedding
-N147 33 Primary-structure Planar Bedding MP-212 105.788 to 98.420f1 AMEC Clinch River SMR Project Borehole MP-212 Acoustic Televiewer Features rev 2 Sheet 9 of 19 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page 972 of 1847 RCN: CRP-111 0.0 Page C1-974 of 1849 9
AMEC Environmental & Infrastructure, Inc.
Clinch River SMR Project 106.
107.
AMEC Project 6468-13-1072
-N145 23 Primary-structure Planar Bedding
-N323 62 Fracture Planar Hairline-fracture
-N136 23 Primary-structure Planar Bedding
-N320 82 Fracture Discontinuous Hairline-fractun
-N144 33 Primary-structure Planar Bedding 108.
-N138 29 Primary-structure Planar Bedding
-N323 72 Fracture Planar Hairline-fracture
-N141 33 Primary-structure Planar Bedding
-N330 52 Fracture Planar Hairline-fracture 109.
110.
-N139 31 Primary-structure Planar Bedding 111.
-N127 34 Primary-structure Planar Bedding 112.
-N149 28 Primary-structure Planar Bedding 113.
MP-212 113.156to 105.788ft AMEC Clinch River SMR Project Borehole MP-212 Acoustic Televiewer Features rev 2 Sheet 10 of 19 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page 973 of 1847 RCN: CRP-111 0.0 Page C1-975 of 1849 10
AMEC Environmental & Infrastructure, Inc.
Clinch River SMR Project AMEC Project 6468-13-1072
-N31 9 77 Fracture Planar Hairline-fracture
-N149 31 Primary-structure Planar Bedding
-N142 32 Primary-structure Planar Bedding
-N131 27 Primary-structure Planar Bedding
-N147 31 Primary-structure Planar Bedding
-N143 28 Primary-structure Planar Bedding
-N337 66 Fracture Planar Hairline-fracture
-N124 37 Primary-structure Planar Bedding
-N138 34 Primary-structure Planar Bedding MP-212 120.524 to 113.156ft AMEC Clinch River SMR Project Borehole MP-212 Acoustic Televiewer Features rev 2 Sheet 11 of 19 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page 97 4 of 1847 RCN: CRP-111 0.0 Page C1-976 of 1849 11