AMEC Environmental & Infrastructure, Inc.
Clinch River SMR Project 162.
163.
164.
165.
166.
167.
168.
AMEC Project 6468-13-1072
-N154 26 Fracture Planar Open-fracture MP-113 168.768to 161.400ft AMEC Clinch River SMR Project Borehole MP-113 Acoustic Televiewer Features rev 2 Sheet 20 of 22 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-801 of 1849 January 11, 2014 Page 799 of 1847 RCN: CRP-111 0.0 20
AMEC Environmental & Infrastructure, Inc.
Clinch River SMR Project 169.
170.
171.
172.
173.
174.
175.
176.
AMEC Project 6468-13-1072
-N149 25 Primary-structure Planar Bedding MP-113 176.136to 168.768ft AMEC Clinch River SMR Project Borehole MP-113 Acoustic Televiewer Features rev 2 Sheet 21 of 22 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-802 of 1849 January 11, 2014 Page 800 of 1847 RCN: CRP-111 0.0 21
AMEC Environmental & Infrastructure, Inc.
Clinch River SMR Project 177.
AMEC Project 6468-13-1072 MP-113 177.204to 176.136ft AMEC Clinch River SMR Project Borehole MP-113 Acoustic Televiewer Features rev 2 Sheet 22 of 22 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-803 of 1849 January 11, 2014 Page 801 of 1847 RCN: CRP-111 0.0 22
AMEC Environmental & Infrastructure, Inc.
Clinch River SMR Project AMEC Project 6468-13-1072 G~Ms,!on BHTV DATA PROCESSING RGLDIP vsn 6.2 geophysical services INTERPRETED BHTV DIPS LOG AMEC Borehole: MP-120 CLINCH RIVER top of borehole.....
North ref. is true East: -
Depth units are feet North:_
Vertical scale: 1/10 Elev:
Horiz scale = 1.00x Vert scale Zone from 348.236 to 21.9681!
Borehole diam: 3.900inch Format: BHTV-NESWN Vertical = borehole-axis Image: Amplitude Stratigraphic dips Identified units ARROW PLOT COMMENTS N315o N45o N
E s
w 20° 60° 90°------7 ------7 MP-120 25.812 to 21.968ft AMEC Clinch River SMR Project Borehole MP-120 Acoustic Televiewer Features rev 2 Sheet 1 of 45 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page 802 of 1847 RCN: CRP-111 0.0 Page C1-804 of 1849
AMEC Environmental & Infrastructure, Inc.
Clinch River SMR Project MP-120 33.180 to 25.812ft AMEC Project 6468-13-1072
-bottom of steel casing
-N355 61 Fracture Planar Hairline-fracture
-N145 42 Primary-structure Planar Bedding
-N167 37 Primary-structure Planar Bedding
-N162 31 Primary-structure Planar Bedding
-N175 37 Primary-structure Planar Bedding
-N174 36 Primary-structure Planar Bedding
-N153 33 Primary-structure Planar Bedding
-N345 54 Fracture Planar Hairline-fracture AMEC Clinch River SMR Project Borehole MP-120 Acoustic Televiewer Features rev 2 Sheet 2 of 45 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-805 of 1849 January 11, 2014 Page 803 of 1847 RCN: CRP-111 0.0 2
AMEC Environmental & Infrastructure, Inc.
Clinch River SMR Project MP-120 40.548 to 33.180ft AMEC Project 6468-13-1072
-N167 32 Primary-structure Planar Bedding
-N168 28 Primary-structure Planar Bedding
-N334 47 Fracture Planar Hairline-fracture
-N168 32 Primary-structure Planar Bedding
-N160 32 Primary-structure Planar Bedding
-N356 57 Fracture Planar Hairline-fracture
-N181 35 Primary-structure Planar Bedding
-N345 69 Fracture Planar Hairline-fracture
-N320 58 Fracture Discontinuous Hairline-fractun
-N149 31 Primary-structure Planar Bedding
-N325 68 Fracture Discontinuous Hairline-fractun
- _N323 55 Fracture Discontinuous Hairline-fractun N165 28 Primary-structure Planar Bedding
-N148 38 Primary-structure Planar Bedding
-N156 29 Primary-structure Planar Bedding
- N335 55 Fracture Discontinuous Hairline-fractun
-N156 31 Primary-structure Planar Bedding 3
AMEC Clinch River SMR Project Borehole MP-120 Acoustic Televiewer Features rev 2 Sheet 3 of 45 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-806 of 1849 January 11, 2014 Page 804 of 1847 RCN: CRP-111 0.0
AMEC Environmental & Infrastructure, Inc.
Clinch River SMR Project
~ =-* ~
r:.',~r~
~ -
~
~-. !'
~
~
.J I
~~
- ~*
. ~.....
~..:.,.
~
f\\".......
I";~
r**--~~
..;-~
~-
~.. ~~:
~\\,
~~-....
- .£ I'~**,
./
fc.
lr-"
~
~~--* "" "" ~
"'<I r**
0
~....
~0 0
~ ~-
~0 -
1-0 t-
~~.
it*.II I'";
~-,,
~ 1
- ~*
~ *
~ -
I
',;' =
r:::*
~~-_. :-,
,:~~
~~~~ *-*
r.~~-~~l ~-.!:~
!""*~
-~~
~~
"',.. (~
~
~
AMEC Project 6468-13-1072
~
/// ~
-N146 31 Primary-structure Planar Bedding
"\\
.~
f=---= -N143 32 Primary-structure Planar Bedding
\\ *
~
-N326 66 Fracture Discontinuous Hairline-fractun
~
-N160 30 Primary-structure Planar Bedding I\\
........ f********
~L. f==-= -N157 28 Primary-structure Planar Bedding
[I
~
/
~
-N151 31 Primary-structure Planar Bedding
\\
-~
!===== -N333 41 Fracture Discontinuous Hairline-fractun I~.
// ~
-N143 34 Primary-structure Planar Bedding I'
/
~
-N153 33 Primary-structure Planar Bedding
/
~
-N150 34 Primary-structure Planar Bedding
~
./
~
-N155 32 Primary-structure Planar Bedding
\\
MP-120 47.916 to 40.548ft 4
AMEC Clinch River SMR Project Borehole MP-120 Acoustic Televiewer Features rev 2 Sheet 4 of 45 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page 805 of 1847 RCN: CRP-111 0.0 Page C1-807 of 1849
AMEC Environmental & Infrastructure, Inc.
Clinch River SMR Project
.... ~~
AMEC Project 6468-13-1072
\\ * )
!==== -N321 65 Fracture Discontinuous Hairline-fractun I
t===
-N156 29 Fracture Planar Open-fracture
~
-N154 31 Primary-structure Planar Bedding
~ ~
.. 'l. :--~
~
/
~
-N150 36 Primary-structure Planar Bedding
~-l~
'- "....... ~
T f--------
~
.* *<.'?
~ :~
~:~
- ~
/
f.......-------
~-.
I\\
-N146 29 Primary-structure Planar Bedding f--------
~<
- ~
~
/
~
-N159 36 Primary-structure Planar Bedding f--------
- ~*
f--------
I I
~ ~
/
~
-N152 35 Primary-structure Planar Bedding f--------
f--------
.~~ ~
-N147 31 Primary-structure Planar Bedding j
MP-120 55.284 to 47.916ft AMEC Clinch River SMR Project Borehole MP-120 Acoustic Televiewer Features rev 2 Sheet 5 of 45 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page 806 of 1847 RCN: CRP-111 0.0 Page C1-808 of 1849 5
AMEC Environmental & Infrastructure, Inc.
Clinch River SMR Project AMEC Project 6468-13-1072 o -----+------r---*-+------*~--+---1--+*-+-+-+-+-t-r--------
r--------
~
~
[\\
/
~
-N156 30 Primary-structure Planar Bedding o -----+------r---*-t------, ~--+---1--+*-+-+-+-+-t-r--------
r--------
I 1---=-.
~
-~
~-
-bit marking
- ~
I\\
/
~
-N151 30 Primary-structure Planar Bedding
~ ------+*-*--*--+-*-**-*-*+-*----l -+---t----1--t--+--+-+-+-t-~--------*
r*=**-**-**-****-~*-**-**-**-**-**-+*-*****-***-*-+*-**-*-*----**-H***-**-***+--+ ~- -+-+-++-t+ ~
~-
-N153 29 Primary-structure Planar Bedding I\\
60.0 e ------+---------+-------*+-**----*-' -+---t----t--+--+--+-+-+-t-~--------*
/
v----
-N155 33 Primary-structure Planar Bedding 61
~ ----*-+*---*--+-*c**-*-+-*----- ~ -+---t----t--+--+--+-+-+-t-~--------*
/
~
-N146 31 Primary-structure Planar Bedding ti\\
/
~
-N145 28 Primary-structure Planar Bedding
~ ------+-*--*--+----*-*-+-**----l -+---t----t--+- '+--+-+-+-t-~--------*
/
~
-N152 32 Primary-structure Planar Bedding MP-120 62.652 to 55.284ft AMEC Clinch River SMR Project Borehole MP-120 Acoustic Televiewer Features rev 2 Sheet 6 of 45 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page 807 of 1847 RCN: CRP-111 0.0 Page C1-809 of 1849 6
AMEC Environmental & Infrastructure, Inc.
Clinch River SMR Project
_.... ~ *., "
I
- I
~
AMEC Project 6468-13-1072
\\
/
[--------
/
~
~
-N149 31 Primary-structure Planar Bedding
[--------
I'
/
~
-N158 34 Primary-structure Planar Bedding I
[--------
~
/
~
-N155 31 Primary-structure Planar Bedding
[--------
~ ~
~
~
-N152 26 Primary-structure Planar Bedding I'
/
~
-N157 35 Primary-structure Planar Bedding
[--------
7
[--------
~
-N152 28 Primary-structure Planar Bedding i\\
I'
/
~
-N157 33 Primary-structure Planar Bedding
~
/
t::===== -N152 36 Primary-structure Planar Bedding I~
// ~
-N146 34 Primary-structure Planar Bedding f--------
MP-120 70.020 to 62.652ft AMEC Clinch River SMR Project Borehole MP-120 Acoustic Televiewer Features rev 2 Sheet 7 of 45 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page 808 of 1847 RCN: CRP-111 0.0 Page C1-810 of 1849 7
AMEC Environmental & Infrastructure, Inc.
Clinch River SMR Project 71.0 r<
72.0 lo I
73.0 74.0
~
~
_____ /
75.0 v
v
~
~
76.0
~ \\
v 77.0
- r.-:
. *~
~ -
~
~
AMEC Project 6468-13-1072 I'
/
~
-N155 35 Primary-structure Planar Bedding
[--------
~
./"/_/ ~
-N152 31 Primary-structure Planar Bedding
/
~
-N150 37 Primary-structure Planar Bedding
[\\
[--------
I ~
/
~
-N150 35 Primary-structure Planar Bedding L ~
-N159 36 Primary-structure Planar Bedding I\\ ;x ~
-N333 49 Fracture Discontinuous Hairline-fractun
~
-N149 31 Primary-structure Planar Bedding
~
r-f----
-N316 34 Fracture Irregular Hairline-fracture
\\ :X
~
-N333 51 Fracture Discontinuous Hairline-fractun
~\\
-N147 32 Primary-structure Planar Bedding MP-120 77.388 to 70.020ft 8
AMEC Clinch River SMR Project Borehole MP-120 Acoustic Televiewer Features rev 2 Sheet 8 of 45 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page 809 of 1847 RCN: CRP-111 0.0 Page C1-811 of 1849