ML18003A800

From kanterella
Jump to navigation Jump to search
Part 08 Enclosures (Rev. 1) - Part 8 - Enclosures - Geotechnical Exploration and Testing Data Report Appendix C Downhole Geophysical Log. Rpt Part 027 Pages C1-778 Thru C1-788
ML18003A800
Person / Time
Site: Clinch River
Issue date: 12/15/2017
From: James Shea
Tennessee Valley Authority
To:
Office of New Reactors
Fetter A
References
TVACLINCHRIVERESP, TVACLINCHRIVERESP.SUBMISSION.4, CRN.P.PART08, CRN.P.PART08.1
Download: ML18003A800 (11)


Text

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072

-N157 34 Primary-structure Planar Bedding

-N157 33 Primary-structure Planar Bedding

-N153 30 Primary-structure Planar Bedding

-N153 32 Primary-structure Planar Bedding

-N150 31 Primary-structure Planar Bedding

-N167 34 Primary-structure Planar Bedding MP-112 160.468 to 153.1 00f1 AMEC Clinch River SMR Project Borehole MP-112 Acoustic Televiewer Features rev 2 Sheet 19 of 22 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page 776 of 1847 RCN: CRP-111 0.0 Page C1-778 of 1849 19

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project AMEC Project 6468-13-1072

-N152 38 Primary-structure Planar Bedding

-N153 35 Primary-structure Planar Bedding

-N162 33 Primary-structure Planar Bedding MP-112 1 67.836 to 1 60.468f1 AMEC Clinch River SMR Project Borehole MP-112 Acoustic Televiewer Features rev 2 Sheet 20 of 22 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 January 11, 2014 Page 777 of 1847 RCN: CRP-111 0.0 Page C1-779 of 1849 20

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project 175.0 MP-112 1 75.204 to 167.836f1 AMEC Project 6468-13-1072

-N157 34 Primary-structure Planar Bedding

-N164 34 Primary-structure Planar Bedding

-N337 58 Fracture Planar Hairline-fracture

-N160 33 Fracture Planar Open-fracture

-N151 34 Primary-structure Planar Bedding

-N155 34 Primary-structure Planar Bedding AMEC Clinch River SMR Project Borehole MP-112 Acoustic Televiewer Features rev 2 Sheet 21 of 22 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-780 of 1849 January 11, 2014 Page 778 of 1847 RCN: CRP-111 0.0 21

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project

-sediment AMEC Project 6468-13-1072 MP-112 1 76.272 to 175.204f1 AMEC Clinch River SMR Project Borehole MP-112 Acoustic Televiewer Features rev 2 Sheet 22 of 22 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-781 of 1849 January 11, 2014 Page 779 of 1847 RCN: CRP-111 0.0 22

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project G~Ms,!on BHTV DATA PROCESSING RGLDIP vsn 6.2 geophysical services INTERPRETED BHTV DIPS LOG AMEC Borehole: MP-113 CLINCH RIVER top of borehole.....

East: -

North:_

Elev: -

Zone from 177.204 to 24.9321!

Format: BHTV-NESWN Stratigraphic dips Non-stratigraphic dips ~

ARROW PLOT AMEC Project 6468-13-1072 North ref. is true Depth units are feet Vertical scale: 1/10 Horiz scale = 1.00x Vert scale Borehole diam: 3.900inch Vertical = borehole-axis Image: Amplitude Identified units COMMENTS N315o N45o N

E s

w 20° 60° 90°------7 ------7

-bottom of casing

-N158 42 Fracture Planar Open-fracture

-N157 38 Fracture Planar Hairline-fracture

-N155 32 Fracture Planar Open-fracture MP-113 28.776 to 24.932f1 AMEC Clinch River SMR Project Borehole MP-113 Acoustic Televiewer Features rev 2 Sheet 1 of 22 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-782 of 1849 January 11, 2014 Page 780 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project MP-113 36.144 to 28.776f1 AMEC Project 6468-13-1072

-N160 36 Primary-structure Planar Bedding

-N166 36 Primary-structure Planar Bedding

-N156 33 Primary-structure Planar Bedding

-N345 52 Fracture Discontinuous Hairline-fractun

-N164 34 Primary-structure Planar Bedding

-N158 50 Fracture Planar Open-fracture

-N161 37 Primary-structure Planar Bedding

-N145 36 Primary-structure Planar Bedding

-N162 56 Fracture Planar Hairline-fracture

-N167 34 Primary-structure Planar Bedding 2

AMEC Clinch River SMR Project Borehole MP-113 Acoustic Televiewer Features rev 2 Sheet 2 of22 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-783 of 1849 January 11, 2014 Page 781 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project MP-113 AMEC Project 6468-13-1072

-N155 37 Primary-structure Planar Bedding

-N159 33 Primary-structure Planar Bedding

-N159 37 Primary-structure Planar Bedding

-N149 40 Primary-structure Planar Bedding

-N142 33 Primary-structure Planar Bedding 43.512 to 36.144f1 AMEC Clinch River SMR Project Borehole MP-113 Acoustic Televiewer Features rev 2 Sheet 3 of22 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-784 of 1849 January 11, 2014 Page 782 of 1847 RCN: CRP-111 0.0 3

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project MP-113 50.880 to 43.512f1 AMEC Project 6468-13-1072

-N153 89 Fracture Discontinuous Hairline-fractun

-N156 23 Fracture Planar Hairline-fracture

-N164 46 Primary-structure Planar Bedding

-N154 30 Primary-structure Planar Bedding

-N152 36 Primary-structure Planar Bedding

-N156 29 Primary-structure Planar Beddinq 4

AMEC Clinch River SMR Project Borehole MP-113 Acoustic Televiewer Features rev 2 Sheet 4 of22 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-785 of 1849 January 11, 2014 Page 783 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project MP-113 58.248 to 50.880f1 AMEC Project 6468-13-1072

-N153 26 Primary-structure Planar Bedding

-N159 31 Primary-structure Planar Bedding

-N326 73 Fracture Discontinuous Hairline-fractun

-N156 26 Primary-structure Planar Bedding 5

AMEC Clinch River SMR Project Borehole MP-113 Acoustic Televiewer Features rev 2 Sheet 5 of22 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-786 of 1849 January 11, 2014 Page 784 of 1847 RCN: CRP-111 0.0

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project MP-113 AMEC Project 6468-13-1072

-N160 22 Primary-structure Planar Bedding

-N141 25 Primary-structure Planar Bedding 65.616 to 58.248f1 AMEC Clinch River SMR Project Borehole MP-113 Acoustic Televiewer Features rev 2 Sheet 6 of 22 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-787 of 1849 January 11, 2014 Page 785 of 1847 RCN: CRP-111 0.0 6

AMEC Environmental & Infrastructure, Inc.

Clinch River SMR Project

66.
67.
68.
69.
70.
71.
72.

MP-113 AMEC Project 6468-13-1072

-N154 32 Primary-structure Planar Bedding 72.984 to 65.616f1 AMEC Clinch River SMR Project Borehole MP-113 Acoustic Televiewer Features rev 2 Sheet 7 of 22 GEOVision Report 13161-01 Clinch River SMR Project Boring Geophysics rev 0 Clinch River Data Report Rev. 4 CRP-1112.16 Page C1-788 of 1849 January 11, 2014 Page 786 of 1847 RCN: CRP-111 0.0 7