ML18003A674
| ML18003A674 | |
| Person / Time | |
|---|---|
| Site: | Clinch River |
| Issue date: | 12/15/2017 |
| From: | James Shea Tennessee Valley Authority |
| To: | Office of New Reactors |
| Fetter A | |
| References | |
| TVACLINCHRIVERESP, TVACLINCHRIVERESP.SUBMISSION.4, CRN.P.PART08, CRN.P.PART08.1 | |
| Download: ML18003A674 (9) | |
Text
GEOTECHNICAL CORING LOG a me SHEET 5 OF 6 BECHTEL PROJECT NO.: 25847 AMEC PROJECT NO.: 6468-13-1072 COUNTY: Roane, TN I GEOLOGIST: E. Shrum SITE DESCRIPTION: Clinch River SMR Project, Roane County, Tennessee DRILLER: B. Akins/J. Criss Boring Orientation BORING NO.:
MP-219A DRILL METHOD: Mud Rotary/Core DRILL MACHINE: D-120 (MW-1)
Inclination: Vertical GROUND ELEV.:
808.6 ft (NAVD88) NORTHING:
571,254 US ft (NAD83) EASTING: 2,448,185 US ft (NAD83) Azimuth:
NA TOTAL DEPTH: 269.1 ft SAMPLE METHODS: ASTM D 1586-11; 2488-09a; 2113-08; 6032-08 I HAMMER (I D): 140-lb Auto (027)
DATE STARTED:
7/20/13 COMPLETED: 7/25/13 I CASING DEPTH: 24.5 ft CORE BARREL TYPE: HQ3/Diamond Impregnated core bits DRILL RUN L
ELEV. DEPTH RUN RATE REC.
ROD SAMP.
0 ROCK DESCRIPTION AND REMARKS (ft)
(ft)
(ft)
(Min/ft)
(It)
(It)
NO.
G Continued from previous page 2:56 CALCAREOUS SILTSTONE, very dark gray (10YR 3/1, N 3/) and bluish black (5PB 2.5/1) 3:27 to very dusky red (5R 2.5/3, 10R 2.5/2), with trace dark greenish gray (5GY 4/1) to very 594.5 214.1 5.0 3:43 (5.0)
(5.0)
Run 44 dark greenish gray (5G 3/1 ), strong, laminated to moderately bedded, locally thickly 100% 100%
- bedded, fresh, interbedded with little to some, laminated to moderately bedded 2:45 LIMESTONE (MICRITE/WACKESTONE), gray (N 5/, 10YR 6/1-5/1), trace fossils, and few to little, very thin to moderate chert beds, lenses, and nodules (multicolored-gray, 2:59
- green, reddish brown, to black, with calcite filled tensional fractures orthogonal to bedding); locally 2:58 moderate to strong bioturbation, strong HCI reaction (Upper Blackford Formation-Unit A)
(continued) 1:56 589.5 219.1 218.1ft: BJ, 30°, PS, PO, B, II 5.0 2:55 (5.0)
(4.6)
Run 45 L3-54 219.8ft: BJ, 30°, PS, T, B, II 100% 92%
3:05 2:38 2:25
-*- -~5,§_---------------------------------- __ 2~.0 584.5 224.1 3:00
~
LIMESTONE (MICRITE), gray (10YR 6/1), strong, laminated to moderately bedded, locally 1.1 3:30 (1.1)
(0.8)
Run 46
~
nodular, fresh, interbedded with some, laminated to moderately bedded Calcareous 583.4 225.2 100% 73%
SILTSTONE, very dark gray (10YR 3/1) and very dusky red (10R 2.5/2), and few to little, very 3.9 2:27/0.1 Run 47 thin to thin chert beds, lenses, and nodules (multicolored-greenish gray, gray to dark gray, 3:08 (3.9)
(3.9) reddish brown, dusky red, and black, with calcite filled tensional fractures orthogonal to 3:11 100% 100%
bedding); locally moderate to strong bioturbation, trace calcite filled pits, strong HCI reaction 3:42 223.7ft: BJ, 30°, PR, PO, C, II 579.5 229.1 2:29/0.9 224.3,224.0ft: BJ, 30°, PS, T, B, II 5.0 3:41 (5.0)
(5.0)
Run 48 :
230.6,231.4,232.0,232.3ft: BJ, 30°, PS, T, B, II 3:26 100% 100%
3:31 3:26 574.5 234.1 3:54 5.0 4:49 (5.0)
(5.0)
Run 49
~
234.8,238.4ft: BJ, 30°, PS, T, B, II 4:08 100% 100%
2:21 2:38 569.5 239.1 3:32 5.0 2:47 (5.0)
(5.0)
Run 50
~
239.8,240.9,242.1,242.4ft: BJ, 30°, PS, T, B, II 2:28 100% 100%
3:09 2:25 564.5 244.1 3:03 5.0 3:12 (5.0)
(5.0)
Run 51
~
246.7ft: BJ, 30°, PS, T, B, II 2:31 100% 100%
3:35 3:19
- -~11._---------------------------------- __ 2+/-7.4 CALCAREOUS SILTSTONE, very dusky red (10R 3/3) to very dark gray (10YR 3/1), strong, 4:19 laminated to moderately bedded, locally thickly bedded, fresh, interbedded with trace to little, 559.5 249.1 5.0 2:43 (5.0)
(5.0)
Run 52 laminated to moderately bedded LIMESTONE (MICRITE), gray (10YR 6/1), and few to little, very thin to moderate chert beds, lenses, and nodules (multicolored-reddish brown, dusky red, 100% 100%
2:33 brownish gray, and gray, trace bright red jasperoid specks, with calcite filled tensional fractures orthogonal to bedding); locally moderate to strong bioturbation, trace calcite filled 2:26 pits, strong HCI reaction 2:41 247.4,248.0ft: BJ, 30°, PS, T, B, II 252.9,253.4ft: BJ, 30°, PS, T-PO, C, II 3:20 554.5 254.1 5.0 2:54 (5.0)
(5.0)
Run 53 255.1ft: BJ, 30°, PS, T, B, II 100% 100%
257.6,258.0ft: BJ, 30°, PS-US, T, B, II 3:53 3:03 3:41 4:11 549.5 259.1 5.0 3:45 (5.0)
(5.0)
Run 54 260.0ft: BJ, 25°, US, PO, B, II 100% 100%
3:50 Clinch River Data Report Rev. 4 CRP-1112.16 Page B.1-362 of 706
GEOTECHNICAL CORING LOG a me SHEET 6 OF 6 BECHTEL PROJECT NO.: 25847 AMEC PROJECT NO.: 6468-13-1072 COUNTY: Roane, TN I GEOLOGIST: E. Shrum SITE DESCRIPTION: Clinch River SMR Project, Roane County, Tennessee DRILLER: B. Akins/J. Criss Boring Orientation BORING NO.:
MP-219A DRILL METHOD: Mud Rotary/Core DRILL MACHINE: D-120 (MW-1)
Inclination: Vertical GROUND ELEV.:
808.6 ft (NAVD88) NORTHING:
571,254 US ft (NAD83) EASTING: 2,448,185 US ft (NAD83) Azimuth:
NA TOTAL DEPTH: 269.1 ft SAMPLE METHODS: ASTM D 1586-11; 2488-09a; 2113-08; 6032-08 I HAMMER (I D): 140-lb Auto (027)
DATE STARTED:
7/20/13 COMPLETED: 7/25/13 I CASING DEPTH: 24.5 ft CORE BARREL TYPE: HQ3/Diamond Impregnated core bits DRILL RUN L
ELEV. DEPTH RUN RATE REC.
ROD SAMP.
0 ROCK DESCRIPTION AND REMARKS (ft)
(ft)
(ft)
(Min/ft)
(It)
(It)
NO.
G Continued from previous page 3:30 CALCAREOUS SILTSTONE, very dusky red (10R 3/3) to very dark gray (10YR 3/1), strong, laminated to moderately bedded, locally thickly bedded, fresh, interbedded with trace to little, 3:12 laminated to moderately bedded LIMESTONE (MICRITE), gray (10YR 6/1), and few to little, 3:50 very thin to moderate chert beds, lenses, and nodules (multicolored-reddish brown, dusky red, 544.5 264.1
-c-...c.-
5.0 3:11 (5.0)
(4.6)
Run 55 brownish gray, and gray, trace bright red jasperoid specks, with calcite filled tensional fractures orthogonal to bedding); locally moderate to strong bioturbation, trace calcite filled 100% 92%
4:08 pits, strong HCI reaction (continued) 265.3,265.6,265.7ft: BJ, 30°, PS, T-PO, B, II 3:46 3:29 3:47
-539.5 539.5 269.1 Boring and coring terminated at 269.1 feet.
Clinch River Data Report Rev. 4 CRP-1112.16 Page B.1-363 of 706 269.1
BORING r't P-1.'" A BOX---"'----
4.'tQ__(ft)
P.AI...,q, t4.q' St.\\\\, s.o f!QGI'I BORING
'1F* h.9 ~
~
~ 10: _.... 1-
$"Go;
~0{~1.').l.."!, ( l.IG:.t.\\
OEPTH__..!!,!o_(lt)TO ~~~~~
~------~------------------------~,~
Clinch River Data Report Rev. 4 CRP-1112.16 Page 8.1-364 of 706 R"" 11.,
""' ll '
r..~.!- 7Y.I I
MP-219A-Boxes 5 and 6 UNCr r.l fR SMR PIWJECT
- M((. J,(JJ.._Lf &<IJI Hl7.i
~....
IJ()~tN(4 MV* 1'!J(.~-,01 J'. -
- 111 iJfl' UD
...,.t}Tjl
~
~* ;Tf Clinch River Data Report Rev. 4 CRP-1112.16 Page 8.1-365 of 706 P,.," 18, q,. \\* 0.~ \\, 'i.O '""*
> "e ('H>t) rt.,,.. !q"1
\\- 10< \\,
S.O (lOUt)
- StHIOO<')
IH-rii\\ G ~-
rl~.X
'\\
IJ'lO 1:111 ;)
'f" o _l :11 fi
--~
~ -~ --
- -*--:-y **.
~-
w---
- ~
110RING --~.ll!"'p~-z'-'rq~A"'---BOX_..10.___
DEPTH I "I o
.. -- -*+
- -~~- **--..
.~.. ll, *--.=--=
- . ~--
.~.
' ~ *.
~* ~
' ~*
~ " -,., * =;¢ L'
~--..'-'-'-'11
~'".
IIOtfiHG - ~li:!L- + ij()X _IZ. _
IJli'T~
IB'i.l l't1Ti) _ru..Q_ lfl)
Clinch River Data Report Rev. 4 CRP-1112.16 Page 8.1-366 of 706
I){)~ lNG IJCIRING :-t'l!?=.l.'l'l
!lOX !L-
?£1'1H~
fti)Hl -~ill )
I;!) X --~.14:t,__
/J!.IlTH ~-fi!)Td i12."*
c.' 7'Vf**)
f\\.,~.. ')
~ LW, ~
~l'll-'t't"1 1 S'OtlcXll.,',~bL~~.)
0 Jl,.n ~~\\:l,:L2l." ~~ (!QO'I.~Q,_S-'J J..:&l _
R....4,.,
1.1..~1..-,_..,.,,*,~'\\t'OO I-l
- , ~Wn*'l ~p; l\\~07-
' I
,,,, ' I; ' ".L ~
..... '\\ -~
-*41t --~
4
\\:; *....,..- - --
Clinch River Data Report Rev. 4 CRP-1112.16 Page 8.1-367 of 706
MP-219A-Box 17 AMEC PIWJECT (itl(i/1 13 11J72
!30/liNG I>IP* u~e 130X __JL__
DEI'TH
..S"-'
(fl} TO
- t.&q 1 (II) ("'l't:>)
Clinch River Data Report Rev. 4 CRP-1112.16 Page 8.1-368 of 706
a me BECHTEL NO.: 25847 AMEC PROJECT NO.: 6468-13-1072 GEOTECHNICAL BORING LOG Prepared By: MBL Date: 3/5/14 Checked By: JCM Date: 3/5/14 SHEET 1 OF 1 COUNTY: Roane, TN I GEOLOGIST: J. Howard SITE DESCRIPTION: Clinch River SMR Project, Roane County, Tennessee DRILLER: A. Martin/D. Rhodes Boring Orientation BORING NO.:
MP-220 DRILL METHOD: Mud Rotary/Core DRILL MACHINE: CME-55 (C)
Inclination: Vertical GROUND ELEV.:
813.2 ft (NAVD88) NORTHING:
571,147 US ft (NAD83) EASTING: 2,448,232 US ft (NAD83)
Azimuth:
NA TOTAL DEPTH:
101.3 ft I SAMPLE METHODS: ASTM D 1586-11; 2488-09a; 2113-08; 6032-08 I ROD TYPE: AWJ I HAMMER (I D): 140-lb Auto (163745)
DATE STARTED: 7/19/13 I coMPLETED: 7/22/131HoLE DIA.: 4" I CASING DEPTH: 23.7ft I coRE SIZE:HQ3 I BITS USED: 4" Roller Cone ELEV. DEPTH BLOW COUNT (ft)
(ft) 0.5ft 0.5ft 0.5ft 0
20 813.2 ts"I6.L u.u 8
14 8
BLOWS PER FOOT 40 60 80 Ground Surface 22*
SAMP.
L 0
100 NO.
G SS-1 813.2 SOIL DESCRIPTION AND REMARKS FILL: SILTY SAND (SM), light reddish brown (2.5Y 6/3),
medium dense, dry, fine to coarse sand, some low plasticity fine, trace fine gravel, strong HCI reaction 0.0
~
~~
1 QLRESIDUAL soil: GraveilyLEAN c'LA Y (CL), reddiSh brown_
3 Q
ss-2 ~
(5YR 5/3) to brown (7.5YR 5/3), medium stiff to soft, moist, 809.6 3.6 3
2 3
5 807.3 5.9 2
1 3
804.6 8.6 50/0.5 802.3 10.9 50/0.2 799.6 13.6 50/0.1 797.4 15.8 50/0.3 794.7 18.5 50/0.3 "5
. 50/0:2 5QI0,1
. 50/0:3
. 50/0,3
~
low to moderate plasticity fines, little fine angular gravel, little
~
fine to coarse sand, strong HCI reaction 8&3~
-ill 805.2 8.0 f---o=-c---l~
.;;'_Lc:::l~--wEATHERED-ROCK -CALCAREOUS-siLTSTONE-, -*=
SS-4
--=:
sampled as CLAYEY GRAVEL (GC), light greenish gray
~Jl0:31, (5GY 6/2), very dense, moist, fine angular gravel, little ~OQ
~ 'moderate plasticity fines, little fine to coarse sand, strong' t-;s""scr-5-----t-~
~
\\tt~ ~a~~ ________________ _ I
~
WEATHERED ROCK:
CALCAREOUS SILTSTONE,
~
sampled as Sandy SILT (ML), reddish brown (2.5YR 5/4)
~---c~--+-=
-c."'-dl-and weak red (2.5YR 5/3-10R 4/3), hard, dry, non-plastic to ss-6 ~
moderately plastic fines, little fine to coarse sand, few to little
~
fine angular gravel sized rock fragments, strong HCI reaction f---o~---j::~
~
~
796.2 17.0
~ c---WEATHERED-ROCK-CALCAREOUS-siLTSTONE-, -
=
~ 1-sampled as SILTY GRAVEL (GM), greenish gray (10Y 5/1)
.......-os=s-~s __,___~
to weak red (2.5YR 4/2), very dense, dry to moist, fine gravel sized angular rock fragments, little low to moderate plasticity
~
fines, little fine to coarse angular sand, strong HCI reaction
~
~
0
~
~ 789.6 23.6 2;r-
..J 50/0.2
. 50/0,2 SS-9
~
~
~
~
~
~
0
~
~~7~84~.6~~2~8-~6~~~+----+----+-------------------------~~~~.,~~~~~~--5~~~~~~~----~------~~~--~~~2~8.7~
o 50/0.1
~
Soil drilling halted. Log continues on geotechnical coring log
~
~
u
~
d C/o 0
0
""' g
"" 0
~
u
""' g
~
~
~
~
0
~
1-1-
1-Observed water levels:
25.9 ft bgs, AM 7/21113 37.7 ft bgs, AM 7/22/13 dL-----L---~~--~----~--~~------------------------------~--~--~~---------------------------------------------~
Clinch River Data Report Rev. 4 CRP-1112.16 Page B.1-369 of 706
a me GEOTECHNICAL CORING LOG Prepared By: MBL Date: 3/5/14 Checked By: JCM Date: 3/5/14 SHEET 1 OF 2 BECHTEL PROJECT NO.: 25847 AMEC PROJECT NO.: 6468-13-1072 COUNTY: Roane, TN I GEOLOGIST: J. Howard SITE DESCRIPTION: Clinch River SMR Project, Roane County, Tennessee DRILLER: A. Martin/D. Rhodes Boring Orientation BORING NO.:
MP-220 DRILL METHOD: Mud Rotary/Core DRILL MACHINE: CME-55 (C)
Inclination: Vertical GROUND ELEV.:
813.2 ft (NAVD88) NORTHING:
571,147 US ft (NAD83) EASTING: 2,448,232 US ft (NAD83) Azimuth:
NA TOTAL DEPTH:
101.3 ft SAMPLE METHODS: ASTM D 1586-11; 2488-09a; 2113-08; 6032-08 I HAMMER (ID): 140-lb Auto (163745)
DATE STARTED:
7/19/13 COMPLETED: 7/22113 I CASING DEPTH: 23.7 ft CORE BARREL TYPE: HQ3/Diamond Impregnated core bits DRILL RUN L
ELEV. DEPTH RUN RATE REC.
ROD SAMP.
0 ROCK DESCRIPTION AND REMARKS (ft)
(ft)
(ft)
(Min/ft)
(It)
(It)
NO.
G Begin Coring@ 28.7 ft 784.5 28.7 2.6 6:00 (2.6)
(1.3)
Run 1 104.0 CALCAREOUS SILTSTONE, dusky red (2.5YR 3/2), medium strong to strong, laminated to 100% 50%
thinly bedded, locally with moderately bedded appearance, slightly weathered to fresh, 5:00 interbedded with few to little, mostly laminated to thin, locally to moderately bedded, 781.9 31.3 3:00/0.6 LIMESTONE (WACKESTONE/MICRITE), bluish gray (5PB 6/1) to greenish gray (10Y 5/1);
5.0 6:15 (5.0)
(3.6)
Run 2 mod. to strongly bioturbated, strong HCI reaction (Lincolnshire Formation-Fieanor 100% 72%
4:30 Member-Unit B) 28.9,30.2,30.5ft: BJ, 30°, PS-PR, PO, B-K, 111-V 5:00 29.7ft: J, 80°, SR, PO, B, Ill 4:45 30.5ft: J, 50°, PR, PO, C, Ill 31.1-31.2ft: FZ, 30°, PS, P0-0, K, V 6:45 776.9 36.3 31.4-31.5ft: FZ, 30°, PS, P0-0, K, V 5.0 5:00 (5.0)
(4.8)
Run 3 31.7,31.9,34.7,35.0,35.8,36.0,36.2ft: BJ, 30°, PS/US, T-0, B-C/K, II-III 6:30 100% 96%
33.2,34.7ft: J, 60°, PR, PO, B/K,11-111 38.4,41.2ft: J, 60°, SR-PR, PO, C-B, Ill 8:00 40.6ft: BJ, 30°, PR, PO, C, IV 8:30 6:00 771.9 41.3 5.0 6:15 (5.0)
(4.7)
Run 4 42.7,43.2,43.5,45.8ft: BJ, 30°, PR, PO-T, B, II-III 100% 94%
45.8ft: J, 60°, PR, T, B, II 7:30 6:00 7:15 7:00 766.9 46.3 5.0 8:15 (5.0)
(4.8)
Run 5 48.6ft: J, 60°, PR, PO, B, II 100% 96%
49.5,49.8ft: BJ, 30°, PR, P0-0, C-F, 111-V 4:15 6:15 8:15 8:00 761.9 51.3 5.0 8:00 (5.0)
(4.8)
Run 6 51.7,51.9,54.2ft: BJ, 30-40°, PS-PR, PO, B-D, II-IV 100% 96%
53.5ft: J, 50°, PR, PO, B, Ill 5:00 5:30 6:15 5:15 756.9 56.3 5.0 5:30 (5.0)
(4.2)
Run 7 57.7,59.9,60.8,61.0,61.1ft: BJ, 30°, URIPR-PS, PO, B-C, II-III 100% 84%
57.9,59.9ft: J, 60°, PR, PO, B,11-111, with calcite min.
7:30 L2-34 9:15 8:15 9:15 751.9 61.3 5.0 5:30 (5.0)
(5.0)
Run 8 64.9ft: J, 60°, PR, PO, B, Ill 100% 100%
4:45 5:45 5:45 6:00 746.9 66.3 5.0 6:30 (5.0)
(5.0)
Run 9 68.8,70.9ft: J, 60°, PR, PO, B-C, Ill 100% 100%
70.3,71.0ft: BJ, 30°, PR-SL, PO, B, II 4:45 4:30 4:45 8:00 741.9 71.3 5.0 7:00 (5.0)
(4.7)
Run 10 72.0,72.8,73.6,75.8ft: BJ, 30°, SRIPRIPS, PO, B, II-III 100% 94%
75.9,76.0ft: J, 70°, PR, PO, B, II 7:00 5:15 L2-35 7:15 7:00 736.9 76.3 5.0 5:45 (5.0)
(5.0)
Run 11 78.7,79.8ft: BJ, 30°, PR, PO, B-C, II Clinch River Data Report Rev. 4 CRP-1112.16 Page B.1-370 of 706 LO.