AIIEC PROJECT 6468131072
/10RfiiG CQP-215 sox_! _
!10/?I.VG __[({1
/Jt l'l/'1 5Dr.,
5
.3()X l/
11111v
'-S"Io_
i* I
~. 0:.1o~*
(\\'l ' (~s*t.
t;" c) ~~ <?
5:d IS ~* zoi).:::,....,._. ( lfX)I.)
K... ~
l~ ~ -s!>*
11..N,:, u~ -;or.;
I CO (C ~*
H '(9t'l.)
~-
~!1 '!' !:>!1
~ -~
-~--- -- -- --
~
Clinch River Data Report Rev. 4 CRP-1112.16 Page 8.1-336 of 706
1\\.
~ ~~--
- ~
CLINCH RIVER SMR PROJECT AM~CPROJECT~46813 1072 BORING MP. 2Js-Clinch River Data Report Rev. 4 CRP-1112.16 Page 8.1-337 of 706
~
d C/o 0
0
""' g
"' 0
~
u
""' g
~
~
~
~
0
~
a me BECHTEL NO.: 25847 AMEC PROJECT NO.: 6468-13-1072 SITE DESCRIPTION: Clinch River SMR Project, Roane County, Tennessee GEOTECHNICAL BORING LOG Prepared By: MBL Date: 3/5/14 Checked By: JCM Date: 3/5/14 SHEET 1 OF 1 COUNTY: Roane, TN I GEOLOGIST: J. Howard DRILLER: A. Martin/D. Rhodes Boring Orientation BORING NO.: MP-216 DRILL METHOD: Mud Rotary/Core DRILL MACHINE: CME-55 (C)
Inclination: Vertical GROUND ELEV.:
813.4 ft (NAVD88) NORTHING:
571,031 US ft (NAD83) EASTING: 2,448,209 US ft (NAD83)
Azimuth:
NA TOTAL DEPTH: 101.5 ft I SAMPLE METHODS: ASTM D 1586-11; 2488-09a; 2113-08; 6032-08 I ROD TYPE: AWJ I HAMMER (ID):140-Ib Auto (163745)
DATE STARTED: 7/30/13 I COMPLETED: 8/1/13 I HOLE DIA.: 4" I CASING DEPTH: 3.5 ft I CORE SIZE:HQ3 I BITS USED: 4" Roller Cone ELEV. DEPTH BLOW COUNT BLOWS PER FOOT (ft)
(ft) 0.5ft 0.5ft 0.5ft 0
20 40 60 813.4 Ground Surface ts"l6.4 u.u 16 50/0.3 810.0 3.4 50/0.4 807.6 5.8 50/0.1 80 SAMP. L 0
100 NO.
G SOIL DESCRIPTION AND REMARKS
. 50/0,3
. 50/0.4 813.4 SS-1
~
WEATHERED ROCK:
CALCAREOUS SILTSTONE,
~
sampled as Sandy SILT with Gravel (ML), pale red (10R 7/2)
~
to weak red (2.5YR 4/2), hard, dry to moist, non-plastic to S'
low plasticity fines, some fine to coarse sand, few to little fine f----o~---t::~ l-angular gravel sized rock fragments, strong HCI reaction SS-2
~
~
~~07.5
~
Soil drilling halted. Log continues on geotechnical coring log Observed water levels:
1-6.1 ftbgs,AM7/31/13 16.2 ft bgs, AM 8/1/13 1-1-
1-1-
1-1-
0.0 5.9 u~--~~--~----~--~----~----------------------------~----~~~----------------------------------------~
Clinch River Data Report Rev. 4 CRP-1112.16 Page B.1-338 of 706
a me GEOTECHNICAL CORING LOG Prepared By: MBL Date: 3/5/14 Checked By: JCM Date: 3/5/14 SHEET 1 OF 2 BECHTEL PROJECT NO.: 25847 AMEC PROJECT NO.: 6468-13-1072 COUNTY: Roane, TN I GEOLOGIST: J. Howard SITE DESCRIPTION: Clinch River SMR Project, Roane County, Tennessee DRILLER: A. Martin/D. Rhodes Boring Orientation BORING NO.:
MP-216 DRILL METHOD: Mud Rotary/Core DRILL MACHINE: CME-55 (C)
Inclination: Vertical GROUND ELEV.:
813.4 ft (NAVD88) NORTHING:
571,031 US ft (NAD83) EASTING: 2,448,209 US ft (NAD83) Azimuth:
NA TOTAL DEPTH:
101.5 ft SAMPLE METHODS: ASTM D 1586-11; 2488-09a; 2113-08; 6032-08 I HAMMER (ID): 140-lb Auto (163745)
DATE STARTED:
7/30/13 COMPLETED: 8/1/13 I CASING DEPTH: 3.5 ft CORE BARREL TYPE: HQ3/Diamond Impregnated core bits DRILL RUN L
ELEV. DEPTH RUN RATE REC.
ROD SAMP.
0 ROCK DESCRIPTION AND REMARKS (ft)
(ft)
(ft)
(Min/ft)
(It)
(It)
NO.
G Begin Coring @ 5.9 ft 807.5 5.9 0.6 5:30/0.6 (0.6)
(0.0)
Run 1 ou,.0 CALCAREOUS SILTSTONE, dusky red (2.5YR 3/2) to dark reddish gray (2.5YR 3/1) with 806.9, 6.5 5.0 5:30 100%
0%
Run 2 dark grayish green (5GY 4/2), medium strong to strong, laminated to very thinly bedded, (5.0) 1(2.6) 5:30 locally with moderately bedded appearance, slightly weathered to fresh, interbedded with trace to few laminated to very thinly bedded LIMESTONE (WACKESTONE/MICRITE),
100% 52%
gray 5:30 (5Y 6/1), locally fossiliferous; strongly bioturbated, strong HCI reaction (Lincolnshire Formation-Fieanor Member-Unit B) 4:30 6.1ft: BJ, 30°, PS, T, B, II 6:00 801.9 11.5 801.9 6.8,9.9ft: J, 30-40°, UR-PR, VT-PO, B, Ill 5.0 5:00 (5.0)
(3.6)
Run 3 17.2-7.3,8.4-8.7,9.2-9.5,10.3-10.6ft: FZ, 30-50°, PR, P0-0, F, III-IV I
100% 72%
18.3ft: BJ, 30°, PR, PO, B, Ill I
4:45
\\1_().~t:_.J,.Z_OO., ~,_9,_8,_11 ________________________ J 4:30 CALCAREOUS SILTSTONE, dusky red (2.5YR 3/2) to dark reddish gray (2.5YR 3/1) with 5:15 dark grayish green (5GY 4/2), medium strong to strong, laminated to very thinly bedded, locally with moderately bedded appearance, fresh, interbedded with few to little laminated to 5:00 796.9 16.5 very thinly bedded LIMESTONE (WACKESTONE/MICRITE), gray (5Y 6/1) to bluish gray (58 5.0 3:15 (5.0)
(4.2)
Run 4 6/1 ), locally fossiliferous; strongly bioturbated, strong HCI reaction 100% 84%
13.7,14.1,14.3,15.3,15.5,15.7,16.0ft: BJ, 30°, PS, PO, B-C, II-IV 2:45 16.1-16.2ft: FZ, 30°, PS, 0, F, IV 2:45 16.8,17.1,17.3,19.3,19.6,20.2ft: BJ, 30°, PS-PR, P0-0, B-F, II-IV 3:15 17.4ft: J, 70°, PR, PO, C, Ill 3:30 791.9 21.5 5.0 7:00 (5.0)
(4.5)
Run 5 23.0,23.8,23.9,24.1,24.9ft: BJ, 30°, PS-PR, T-PO, B, II-III 100% 90%
5:45 4:30 7:30 6:00 786.9 26.5 5.0 4:30 (5.0)
(3.7)
Run 6 26.8,27.0,27.5,28.0,28.2,28.4,28.8,29.4,29.6ft: BJ, 30°, PS, T-PO, B, II 100% 74%
27.7ft: J, 40°,SR, PO, B, II 5:00 30.7ft: J, 70°, SR, PO, B, Ill 4:45 5:00 6:00 781.9 31.5 5.0 4:45 (5.0)
(5.0)
Run 7 33.0,34.2ft: BJ, 30°, PS, T, B, II 100% 100%
34.3,35.3ft: J, 70-80°, SR, VT-PO, A-B, I-III 4:30 5:30 4:45 5:15 776.9 36.5 5.0 9:15 (5.0)
(5.0)
Run 8 37.5,39.2,40.7ft: BJ, 30°, PS-US, T-PO, B-C, II 100% 100%
40.3,41.5ft: J, 70°, PS/SR, T-PO, B-C,11-111, with calcite min.
7:15 7:00 5:45 6:00 771.9 41.5 5.0 4:15 (5.0)
(4.3)
Run 9 42.4,45.4ft: BJ, 30°, PS, T-PO, B, II 100% 86%
45.6ft: J, 60°, PR, PO, C, Ill 4:45 4:45 5:45 5:30 766.9 46.5 5.0 4:45 (5.0)
(4.5)
Run 10 46.8,47.0,48.0ft: BJ, 30°, PS/SL, PO, B, II 100% 90%
4:30 6:00 4:00 4:30 761.9 51.5 5.0 4:15 (5.0)
(4.8)
Run 11 51.7-51.9ft: FZ, 40°, PR, P0-0, C, IV 100% 96%
54.5ft: BJ, 30°, PS, PO, B, II 4:30 5:15 Clinch River Data Report Rev. 4 CRP-1112.16 Page B.1-339 of 706
- 0.
11.5
GEOTECHNICAL CORING LOG a me SHEET 2 OF 2 BECHTEL PROJECT NO.: 25847 AMEC PROJECT NO.: 6468-13-1072 COUNTY: Roane, TN I GEOLOGIST: J. Howard SITE DESCRIPTION: Clinch River SMR Project, Roane County, Tennessee DRILLER: A. Martin/D. Rhodes Boring Orientation BORING NO.:
MP-216 DRILL METHOD: Mud Rotary/Core DRILL MACHINE: CME-55 (C)
Inclination: Vertical GROUND ELEV.:
813.4 ft (NAVD88) NORTHING:
571,031 US ft (NAD83) EASTING: 2,448,209 US ft (NAD83) Azimuth:
NA TOTAL DEPTH:
101.5 ft SAMPLE METHODS: ASTM D 1586-11; 2488-09a; 2113-08; 6032-08 I HAMMER (ID): 140-lb Auto (163745)
DATE STARTED:
7/30/13 COMPLETED: 8/1/13 I CASING DEPTH: 3.5 ft CORE BARREL TYPE: HQ3/Diamond Impregnated core bits DRILL RUN L
ELEV. DEPTH RUN RATE REC.
ROD SAMP.
0 ROCK DESCRIPTION AND REMARKS (ft)
(ft)
(ft)
(Min/ft)
(It)
(It)
NO.
G Continued from previous page 4:45 CALCAREOUS SILTSTONE, dusky red (2.5YR 3/2) to dark reddish gray (2.5YR 3/1) with dark grayish green (5GY 4/2), medium strong to strong, laminated to very thinly bedded, 6:00 756.9 56.5 locally with moderately bedded appearance, fresh, interbedded with few to little laminated to 5.0 4:15 (5.0)
(4.6)
Run 12 very thinly bedded LIMESTONE (WACKESTONE/MICRITE), gray (5Y 6/1) to bluish gray (58 100% 92%
6/1 ), locally fossiliferous; strongly bioturbated, strong HCI reaction (continued) 4:00 58.9,60.4,60.5ft: BJ, 30°, PR, T-PO, B-C, II 4:30 60.3,60.9ft: J, 60-70°, SR, T-PO, B, II 4:00 4:00 751.9 61.5 5.0 3:45 (5.0)
(5.0)
Run 13 62.6,65.5ft: BJ, 30°, UR-PR, T-PO, B, II 100% 100%
62.7ft: J, 80°, SR, PO, B, II 4:00 4:00 4:00 4:15 746.9 66.5 5.0 4:15 (5.0)
(4.6)
Run 14 67.2ft: BJ, 30°, PS, T, B, II 100% 92%
4:00
-*- =7+/-_4,+/-_---------------------------------- -- ~.0 4:15
~
CALCAREOUS SILTSTONE, dusky red (2.5YR 3/2) to dark reddish gray (2.5YR 3/1) with 4:45 dark grayish green (5GY 4/2), medium strong to strong, laminated to very thinly bedded, locally with moderately bedded appearance, fresh, interbedded with little to some laminated to 5:15 741.9 71.5 very thinly bedded LIMESTONE (WACKESTONE/MICRITE), gray (5Y 6/1) to bluish gray (58 5.0 4:30 (5.0)
(5.0)
Run 15 6/1 ), locally fossiliferous; strongly bioturbated, strong HCI reaction 100% 100%
4:30 69.1,69.3,69.7,70.4,70.6,70.9ft: BJ, 30°, PS-PR, T, B, II 74.4,75.0ft: BJ, 30°, PR, T, B, II 4:00 3:45 4:15 736.9 76.5 5.0 5:45 (5.0)
(4.7)
Run 16 78.7,78.8ft: BJ, 30°, PR, PO, B, Ill 100% 94%
7:30
--* =7}_4,+/-_ ____________________________________ TIJ.O 4:30
~
CALCAREOUS SILTSTONE, dusky red (2.5YR 3/2) to dark reddish gray (2.5YR 3/1) with 4:00 dark grayish green (5GY 4/2), medium strong to strong, laminated to very thinly bedded, locally with moderately bedded appearance, fresh, interbedded with few to little laminated to 6:00 731.9 81.5 very thinly bedded LIMESTONE (WACKESTONE/MICRITE), gray (5Y 6/1) to bluish gray (58 5.0 7:15 (5.0)
(4.8)
Run 17 6/1 ), locally fossiliferous; strongly bioturbated, strong HCI reaction 100% 96%
5:45 79.0,79.9,80.7ft: BJ, 30°, PR-PS, T-PO, B-C, II-IV 82.0-82.2ft: FZ, 30-50°, PR, P0-0, F, IV 5:15 82.6ft: BJ, 30°, PS, T, B, II 5:00 83.5ft: J, 70°, SR, T-PO, C, II 5:00 726.9 86.5 5.0 4:15 (5.0)
(5.0)
Run 18 88.0,89.3ft: BJ, 30°, PS, T, B, II 100% 100%
3:30 3:30 4:00 4:30 721.9 91.5 5.0 3:45 (5.0)
(5.0)
Run 19 93.1ft: SH, 30°, PL, T, C, II, with calcite 100% 100%
94.0ft: J, 70°, SR, T, B, II 4:00 95.7ft: BJ, 30°, PS, PO, B, II 3:45 4:30 4:45 716.9 96.5 5.0 4:30 (4.8)
(4.6)
Run 20 96.5ft: SH, 30°, PL, T-PO, C, II, with calcite 96%
92%
96.7,97.8,99.4ft: BJ, 30°, PS, T, B, II-III 4:00 96.8,99.9ft: J, 70°, SR-PR, T, B-C,11-111 4:15 4:15 4:15 711.9 101.5 711.9 101.5 Boring and coring terminated at 101.5 feet.
Clinch River Data Report Rev. 4 CRP-1112.16 Page B.1-340 of 706
CLINCH I<IVE I~ SMH PI\\CJJECT
.4fv1EC PHOJECl fi,lr JJ()Il ' G MP-21(. r;n f
IJ~ I'TH 5 "\\_fit) TO ~(il) f3(JRJHG IV' p. 'Z( & 130X _ '2_
!)fPIH I eoS ffl) TO
'JI 5 (It) fJOil/NG /\\AP"'Z.IC IJfiX_> __
DCPTH )£. 5
{ft}TO ~(Hl Clinch River Data Report Rev. 4 CRP-1112.16 Page 8.1-341 of 706
")S 0
(/f.S I
_/ __
-t(...,;) S o(lo <>/) ( 5"( 7v )
RUN-INTERVAL 1ft) REC lftl 1%1 RQD (ft)- (%)
'1-) s. o f'_;;.s1/
s.o (tou/.) 1 <t2 $'f.-'
t;) S. 0 (.... ~[5/ 5.o (toc:<)/-'f ')(<;or.)
(,) S'.o r:'j[5)/.S.o (roo;;) I J 7 C 7'/<:.J RUN INTERVAL (ft) HEC lftl
('Y..l RQO !It\\- 1"1\\)
J!iJ 5.or~~~~1 (b-o lfo.,.::-J / :
~.:r.s'.("\\t.'>)
\\1 ) 5.o ~S)"'f.. '5) h-. o ( fooD ( ~("r'cnj * ('\\(.)
1 '2.) t;.0 ( '>~"f.'S' f~. 0 (t ocv.Y q r. ~ c. r.)
MP-216-Boxes 5 and 6 BOI?ING 1"\\? '2l G ilOll..£.__
DEPTH c,r.)
(II)TO ~(ftl
- ~Ill!
~
....1!~- ---..
.... ~-.-....-.=~
\\.. -*
~~
MP-216-Box 7 Clinch River Data Report Rev. 4 CRP-1112.16 Page 8.1-342 of 706 RUN INTERVAL lftl REC if\\\\ 1%\\ RQI) tft) - 1%\\
- t(,J 5" o (~;?.n/S.oGo a l,) ( '-1.7 ~ 'i/.)
17 s. o ( ~~{,.s)) 5.o (loo~:J I '1* r~:r4:.f3: ('\\~a"~
t 6)---;:;?e_,_.,f1 \\JS* D{1oD 7)/~
~ S.o' '(JOOl
a me BECHTEL NO.: 25847 AMEC PROJECT NO.: 6468-13-1072 SITE DESCRIPTION: Clinch River SMR Project, Roane County, Tennessee BORING NO.:
MP-217 DRILL METHOD: Mud Rotary/Core COUNTY:
GEOTECHNICAL BORING LOG Prepared By: MBL Date: 3/5/14 Roane, TN Checked By: JCM Date: 3/5/14 SHEET 1 OF 1 I GEOLOGIST: J. Terry DRILLER: G. Akins/K. Amburn Boring Orientation DRILL MACHINE: D-120 (MW-2)
Inclination: Vertical GROUND ELEV.:
811.6 ft (NAVD88) NORTHING:
571,125 US ft (NAD83) EASTING: 2,448,169 US ft (NAD83)
Azimuth:
NA TOTAL DEPTH: 99.3 ft I SAMPLE METHODS: ASTM D 1586-11; 2488-09a; 2113-08; 6032-08 I ROD TYPE: AWJ I HAMMER (I D): 140-lb Auto (R308)
DATE STARTED: 7/23/13 I COMPLETED: 7/25/131 HOLE DIA.: 4" ELEV.
(ft) 811.6 ts"l"l.t) 809.2 806.7 804.3 801.8 798.3 796.6 791.6 786.6 781.6 776.9 775.6 772.7 DEPTH BLOW COUNT BLOWS PER FOOT (ft) 0.5ft 0.5ft 0.5ft 0
20 40 60 Ground Surface u.u 3
7 5
,12*
2.4 3
4 6
10 4.9 2
2 1
.* 3.
7.3 5-1--2- ~4 9.8 2
1 2
- 3.
13.3 2-1--1-15.0 3
1 1
2 3*
20.0 1
3 4
~7 25.0 3-1--3-6 30.0 1
2 3
.* 5*
34.7 5
10 13 36.0
- '3 6
6 8
38.9 50/0.1 Clinch River Data Report Rev. 4 CRP-1112.16 Page B.1-343 of 706 I CASING DEPTH: 39.3 ft I CORE SIZE:HQ3 I BITS USED: 3" Roller Cone SAMP.
L 80 100 0
SOIL DESCRIPTION AND REMARKS NO.
G 811.6 0.0 SS-1
~
FILL: LEAN CLAY with Gravel (CL), yellowish brown (10YR 5/6) to brown (7.5YR 5/4), stiff, dry to moist, low to moderate
{0 I-plasticity fines, little fine to coarse angular to subangular
ss:2 gravel, trace to few fine to coarse sand, strong HCI reaction
~
807.1 4.5
ss:3 ~
"'""-FiLL:c"LA YEY GRA VELwiih Sand (GC)~rown (7.5YR"474)-. -* ~
very loose, moist, fine to coarse angular gravel, little to some t-low to moderate plasticity fines, few fine sand, strong to
~
weak HCI reaction SS-4 7.3ft: As above, brown (7.5YR 4/3), little to some fine to medium sand SS-5 ~
~
~~----------------------12Q FILL: Gravelly LEAN CLAY with Sand (CL), brown (7.5YR
~
4/2), soft, moist, low to moderate plasticity fines, little fine to J0 coarse angular gravel, little fine to medium sand, weak HCI frg6_6 reaction 15_0
~
SS-7
~
FILL: LEAN CLAY (CL), dark grayish brown (10YR 4/2), soft, moist, low to moderate plasticity fines, few fine to coarse
~
I-subangular gravel, trace to few fine to coarse sand, weak
~9:3&..._H~ ~a_::ti~ __________________
18Q FILL: CLAYEY GRAVEL (GC), brown (10YR 4/3), loose, moist, fine angular gravel, little low plasticity fines, weak HCI reaction SS-8 I 1-
~~~---------------------23Q RESIDUAL SOIL: LEAN CLAY with Gravel (CL), brown (10YR 4/3) to reddish brown (2.5YR 4/4), medium stiff,
ss:g {0 moist, low to moderate plasticity fines, little fine angular
~
gravel, few coarse sand, strong HCI reaction
~~---------------------_llQ RESIDUAL SOIL: Gravelly LEAN CLAY (CL), yellowish
{0 brown (10YR 5/4), medium stiff, moist, low to moderate
{0 plasticity fines, some fine to coarse angular to subangular gravel, few coarse sand, weak HCI reaction ss::i() {0
~
I-
~!l£RESIDUAL sOIL: cLAYEY-GRAvEL -with-sand (GcC~
3 Q
reddish brown (2.5YR 4/3), very stiff, moist, some fine to SS-11 coarse subangular to angular gravel, little to some fine coarse sand, little low plasticity fines, strong HCI reaction SS-12 ~
1-
~
~3.6 38.0
-WEATHERED-ROCK -CALCAREOUS-siLTSTONE-, --"'
. 5*
SS-13 772.3 sampled as WELL GRADED GRAVEL with Sand (GP), dar~r reddish brown (2.5YR 3/3), very dense, wet, fine to coarse angular gravel, some coarse sand, trace to few non-plastic to 1-low plasticity fines, strong HCI reaction Soil drilling halted. Log continues on geotechnical coring log Observed water levels: