ML18003A351
| ML18003A351 | |
| Person / Time | |
|---|---|
| Site: | Clinch River |
| Issue date: | 12/15/2017 |
| From: | James Shea Tennessee Valley Authority |
| To: | Office of New Reactors |
| Fetter A | |
| References | |
| TVACLINCHRIVERESP, TVACLINCHRIVERESP.SUBMISSION.4, CRN.P.PART02, CRN.P.PART02.1 | |
| Download: ML18003A351 (40) | |
Text
2.5.1-259 Revision 1 Clinch River Nuclear Site Early Site Permit Application Part 2, Site Safety Analysis Report Source: Reference 2.5.1-282 Figure 2.5.1-64.
Geologic Map and Cross Section B-B'
2.5.1-260 Revision 1 Clinch River Nuclear Site Early Site Permit Application Part 2, Site Safety Analysis Report Notes:
See Table 2.5.1-17 for MP-Series boring data. B-series boring data from Reference 2.5.1-100.
Geometry of shear-fracture zones are shown on Figures 2.5.1-66 and 2.5.1-67.
Figure 2.5.1-65.
(Sheet 1 of 2) Structure Contour Map of Shear Fracture Zones and Associated Profile
2.5.1-261 Revision 1 Clinch River Nuclear Site Early Site Permit Application Part 2, Site Safety Analysis Report Figure 2.5.1-65.
(Sheet 2 of 2) Map of Cross-Section Locations and Boreholes that Encountered Shear Fracture Zones
2.5.1-262 Revision 1 Clinch River Nuclear Site Early Site Permit Application Part 2, Site Safety Analysis Report Figure 2.5.1-66.
Cross-Section through the Shear-Fracture Zone within the Eidson Member of the Lincolnshire Formation (Cross Section Line A in Figure 2.5.1-65)
2.5.1-263 Revision 1 Clinch River Nuclear Site Early Site Permit Application Part 2, Site Safety Analysis Report Figure 2.5.1-67.
Cross-Section Through All Shear-Fracture Zone Features (Cross Section Line B in Figure 2.5.1-65)
2.5.1-264 Revision 1 Clinch River Nuclear Site Early Site Permit Application Part 2, Site Safety Analysis Report Figure 2.5.1-68.
Schematic Diagram of the Crosscutting Relationships Between Bedding, Stylolites, and Shear-Fracture Zones
2.5.1-265 Revision 1 Clinch River Nuclear Site Early Site Permit Application Part 2, Site Safety Analysis Report From Reference 2.5.1-292.
Figure 2.5.1-69.
Karst Hydrogeologic Model for the Valley and Ridge Region, Tennessee
2.5.1-266 Revision 1 Clinch River Nuclear Site Early Site Permit Application Part 2, Site Safety Analysis Report Epigenic and hypogenic karst in the context of basinal groundwater flow. The figure shows mainly gravity-driven flow in an idealized homogenous basin. In reality, most sedimentary sequences are highly heterogeneous, and gravity-driven flow interacts with other flow mechanisms. From Reference 2.5.1-289.
Figure 2.5.1-70.
Epigenetic and Hypogenetic Karst in Basinal Groundwater Flow
2.5.1-267 Revision 1 Clinch River Nuclear Site Early Site Permit Application Part 2, Site Safety Analysis Report Schematic illustration of isolated phreatic maze cave development within a mixing zone localized near to a fault. Rising water along the fault intersects the shallow karst aquifer, and creates cavernous porosity in the mixing zone. If rising fluids were initially hydrothermal, alteration of the bedrock along fractures may result in slightly more resistance to weathering, and result in a cave located within a hill on the land surface. From Reference 2.5.1-296.
Figure 2.5.1-71.
Isolated Phreatic Maze Cave Development in an Anticline Near a Fault
2.5.1-268 Revision 1 Clinch River Nuclear Site Early Site Permit Application Part 2, Site Safety Analysis Report Schematic vertical relationships of flow zones of the ORR, estimated thicknesses, water flow, and water types. From Hatcher et al. (Reference 2.5.1-9), Chapter 7 Figure 2.5.1-72.
Schematic Vertical Relationships of Groundwater Flow Zones in the ORR
2.5.1-269 Revision 1 Clinch River Nuclear Site Early Site Permit Application Part 2, Site Safety Analysis Report Figure 2.5.1-73.
Karst Model of the CRN Site
2.5.1-270 Revision 1 Clinch River Nuclear Site Early Site Permit Application Part 2, Site Safety Analysis Report Note: See Figure 2.5.1-79 for explanation of geologic units 1972-1980 CRBRP borehole data from Reference 2.5.1-100 Figure 2.5.1-74.
Borehole Plan for CRBRP and CRN Investigations
2.5.1-271 Revision 1 Clinch River Nuclear Site Early Site Permit Application Part 2, Site Safety Analysis Report Note: Data from References 2.5.1-100 and 2.5.1-214
- Does not include the Eidson member.
Figure 2.5.1-75.
Cavity Size and Elevation: Kingsport, Mascot, and Blackford Formations
2.5.1-272 Revision 1 Clinch River Nuclear Site Early Site Permit Application Part 2, Site Safety Analysis Report Note: Data from References 2.5.1-100 and 2.5.1-214 Figure 2.5.1-76.
Cavity Size and Elevation: Benbolt Formation and Fleanor Member
2.5.1-273 Revision 1 Clinch River Nuclear Site Early Site Permit Application Part 2, Site Safety Analysis Report Note: Data from References 2.5.1-100 and 2.5.1-214 Figure 2.5.1-77.
Cavity Size and Elevation: Rockdell Formation and Eidson Member
2.5.1-274 Revision 1 Clinch River Nuclear Site Early Site Permit Application Part 2, Site Safety Analysis Report Note: From Reference 2.5.1-9 Figure 2.5.1-78.
Chickamauga Group Stratigraphic Column
2.5.1-275 Revision 1 Clinch River Nuclear Site Early Site Permit Application Part 2, Site Safety Analysis Report Figure 2.5.1-79.
Map Distribution of Cavities in Rock Core
2.5.1-276 Revision 1 Clinch River Nuclear Site Early Site Permit Application Part 2, Site Safety Analysis Report Reference 2.5.1-238 Figure 2.5.1-80.
CRBRP Site Geologic Map
2.5.1-277 Revision 1 Clinch River Nuclear Site Early Site Permit Application Part 2, Site Safety Analysis Report From Reference 2.5.1-238 Note:
(a) Description added to facilitate comparison with Figure 2.5.1-30 Figure 2.5.1-81.
CRBRP Site Geologic Cross Section
2.5.1-278 Revision 1 Clinch River Nuclear Site Early Site Permit Application Part 2, Site Safety Analysis Report Notes:
BRE - Blue Ridge escarpment; CFA - Cape Fear arch; GF - Grenville front; OS - Orangeburg scarp; RFR - Reelfoot rift; CVSZ - Central Virginia seismic zone; ETSZ - East Tennessee seismic zone; GCSZ - Giles County seismic zone; SCSZ - South Carolina seismic zone; NMSZ - New Madrid seismic zone; SNA - Stable North America.
F1, F2, F3, F4, cS1, eS1, and wS1 correspond to geophysical anomalies.
Source: Reference 2.5.1-313 Figure 2.5.1-82.
Conceptual Model of Upper Mantle Structure Beneath the Southeastern U.S.
2.5.1-279 Revision 1 Clinch River Nuclear Site Early Site Permit Application Part 2, Site Safety Analysis Report Note: Vertical axis is two-way travel time (seconds)
Figure 2.5.1-83.
(Sheet 1 of 2) Interpreted Seismic Reflection Profile from Tennessee Highway 95
2.5.1-280 Revision 1 Clinch River Nuclear Site Early Site Permit Application Part 2, Site Safety Analysis Report Source: Reference 2.5.1-9 Figure 2.5.1-83.
(Sheet 2 of 2) Geologic Cross Section Based on Seismic Reflection Profile from Tennessee Highway 95
2.5.1-281 Revision 1 Clinch River Nuclear Site Early Site Permit Application Part 2, Site Safety Analysis Report Source: Reference 2.5.1-318 Figure 2.5.1-84.
Seismic Reflection Profile from Biscayne Bay, Florida, Showing Large Scale Sag Features Attributed to Hypogene Dissolution
2.5.1-282 Revision 1 Clinch River Nuclear Site Early Site Permit Application Part 2, Site Safety Analysis Report Source: Reference 2.5.1-41 Figure 2.5.1-85.
Schematic Cross Section of Biscayne Bay Showing a Possible Model for Hypogene Dissolution
2.5.1-283 Revision 1 Clinch River Nuclear Site Early Site Permit Application Part 2, Site Safety Analysis Report Source: Reference 2.5.1-214 See explanation on Sheet 7.
Figure 2.5.1-86.
(Sheet 1 of 7) Seismic Tomography Model SRS-1
2.5.1-284 Revision 1 Clinch River Nuclear Site Early Site Permit Application Part 2, Site Safety Analysis Report Source: Reference 2.5.1-214 See explanation on Sheet 7.
Figure 2.5.1-86.
(Sheet 2 of 7) Seismic Tomography Model SRS-2
2.5.1-285 Revision 1 Clinch River Nuclear Site Early Site Permit Application Part 2, Site Safety Analysis Report Source: Reference 2.5.1-214 See explanation on Sheet 7.
Figure 2.5.1-86.
(Sheet 3 of 7) Seismic Tomography Model SRS-3
2.5.1-286 Revision 1 Clinch River Nuclear Site Early Site Permit Application Part 2, Site Safety Analysis Report Source: Reference 2.5.1-214 See explanation on Sheet 7.
Figure 2.5.1-86.
(Sheet 4 of 7) Seismic Tomography Model SRS-4
2.5.1-287 Revision 1 Clinch River Nuclear Site Early Site Permit Application Part 2, Site Safety Analysis Report Source: Reference 2.5.1-214 See explanation on Sheet 7.
Figure 2.5.1-86.
(Sheet 5 of 7) Seismic Tomography Model SRS-5
2.5.1-288 Revision 1 Clinch River Nuclear Site Early Site Permit Application Part 2, Site Safety Analysis Report Source: Reference 2.5.1-214 See explanation on Sheet 7.
Figure 2.5.1-86.
(Sheet 6 of 7) Seismic Tomography Model SRS-6
2.5.1-289 Revision 1 Clinch River Nuclear Site Early Site Permit Application Part 2, Site Safety Analysis Report Source: Reference 2.5.1-214 See Sheets 1-6.
Figure 2.5.1-86.
(Sheet 7 of 7) Explanation for Seismic Tomography Models
2.5.1-290 Revision 1 Clinch River Nuclear Site Early Site Permit Application Part 2, Site Safety Analysis Report Source: Reference 2.5.1-319 Figure 2.5.1-87.
Crystalline Calcite Deposits Indicating a Hypogene Origin in Caves of Shenandoah Valley, Virginia
2.5.1-291 Revision 1 Clinch River Nuclear Site Early Site Permit Application Part 2, Site Safety Analysis Report Source: Reference 2.5.1-303 Figure 2.5.1-88.
(Sheet 1 of 2) Geologic Map of the 1983 CRBRP Excavations
2.5.1-292 Revision 1 Clinch River Nuclear Site Early Site Permit Application Part 2, Site Safety Analysis Report Source: Reference 2.5.1-303.
Figure 2.5.1-88.
(Sheet 2 of 2) Geologic Column and Cross Section of the 1983 CRBRP Excavations
2.5.1-293 Revision 1 Clinch River Nuclear Site Early Site Permit Application Part 2, Site Safety Analysis Report Source: Reference 2.5.1-303 Figure 2.5.1-89.
Cavities in the Rockdell Formation Exposed in the 1983 CRBRP Excavations
2.5.1-294 Revision 1 Clinch River Nuclear Site Early Site Permit Application Part 2, Site Safety Analysis Report Note: Core photo from Reference 2.5.1-214 Figure 2.5.1-90.
Interpreted Core Photo of Borehole MP-101 Demonstrating Shear-Fracture Zone Attributes
2.5.1-295 Revision 1 Clinch River Nuclear Site Early Site Permit Application Part 2, Site Safety Analysis Report Note: Geologic unit symbols are defined in Figure 2.5.1-29 (Sheet 2 of 2). The shear zone identified in the CRBRP PSAR is referred to as shear-fracture zone in the current investigation.
Sources: References 2.5.1-303 (Plate 2, mapped shear zone) and Reference 2.5.1-238 (Illustration 7, surface projection of shear zone and outcrop location)
Figure 2.5.1-91.
(Sheet 1 of 3) Site Geologic Map Showing Mapped Shear Zones
2.5.1-296 Revision 1 Clinch River Nuclear Site Early Site Permit Application Part 2, Site Safety Analysis Report Note: The shear zone identified in the CRBRP PSAR is referred to as shear-fracture zone in the current investigation.
Source: Reference 2.5.1-238 (Illustration 7, surface projection of shear zone) and Reference 2.5.1-303 (Plate 2, excavation map, with mapped shear zones and section line A-A)
Figure 2.5.1-91.
(Sheet 2 of 3) Site Geologic Map Showing Excavation, Mapped Shear Zones, and Site Borings
2.5.1-297 Revision 1 Clinch River Nuclear Site Early Site Permit Application Part 2, Site Safety Analysis Report Note: Profile line location shown on Sheet 2 of 3 Source: Reference 2.5.1-303 Figure 2.5.1-91.
(Sheet 3 of 3) Cross Section of CRBRP Excavation Mapping
2.5.1-298 Revision 1 Clinch River Nuclear Site Early Site Permit Application Part 2, Site Safety Analysis Report Source: Reference 2.5.1-303 Figure 2.5.1-92.
Apparent Fault Propagation Fold Exposed in CRBRP Excavation