ML17363A279
| ML17363A279 | |
| Person / Time | |
|---|---|
| Site: | 07201004 |
| Issue date: | 12/14/2017 |
| From: | TN Americas LLC |
| To: | Office of Nuclear Material Safety and Safeguards |
| Shared Package | |
| ML17363A276 | List: |
| References | |
| E-50037 | |
| Download: ML17363A279 (51) | |
Text
Figures 55 50 40 S' 35 1-2 o 30 s
(9
'-' 25 0...
~
z 0:: 20
~
en 15 10 5
UNACCEPTABLE QUALIFIED With 2000 ppm minimum soluble boron (Equiv. Enr. < 1.45 wt. %)
QUALIFIED With 23~0 ppm minimum ~oluble boron (Equiv. Enr. > 1.45 wt. Yo) o
--'--L---'----'-----'------L__-_L_ _
_.__---'----_~
1.40 1.80 2.20 2.60 3.00 3.40 3.80 INITIAL ENRICHMENT (wt.% U-235)
Note: The maximum planar average initial enrichment is specified as "initial enrichment."
Figure 1-1 PWR Fuel Criticality Acceptance Curve for the 24P DSC Standardized NU HOMS System Technical Specifications F-1 Coe 1004 Amendment 15 Application, Revision 2
Figures Zone 2*
Zone 2*
Zone 2*
Zone 2*
Zone 2*
Zone 1*
Zone 1*
Zone 1*
Zone 1
- Zone 2*
Zone 2*
Zone 1
- Zone 1 Zone 1 Zone 1*
Zone 2*
Zone 2*
Zone 1
- Zone 1 Zone 1 Zone 1
- Zone 2*
Zone 2*
Zone 1
- Zone 1
- Zone 1*
Zone 1
- Zone 2*
Zone 2*
Zone 2*
Zone 2*
Zone 2*
Denotes locations where intact or damaged FAs may be stored.
Zone 1 Zone 2 Max. Decay Heat I FA 0.63 0.87 (kW)
Max. Decay Heat I Zone 10.08 13.92 (kW)
Max. Decay Heat / DSC 24.0 (kW)
Notes:
(!)
Up to 28 damaged FAs may be stored in Zone 1 and Zone 2 only.
Figure 1-2 Heat Load Zoning Configuration 1 for the NUHOMS-32PT DSC Standardized NU HOMS System Technical Specifications F-2 CoC 1004 Amendment 15 Application, Revision 2
Figures Zone 2**
Zone 1
- Zone 1*
Zone 2**
Zone 2**
Zone 1
- Zone 1
- Zone 1*
Zone 1
- Zone 2**
Zone 1
- Zone 1*
Zone 1 Zone 1 Zone 1
- Zone 1*
Zone 1*
Zone 1
- Zone 1 Zone 1 Zone 1
- Zone 1
- Zone 2**
Zone 1*
Zone 1
- Zone 1
- Zone 1
- Zone 2**
Zone 2**
Zone 1
- Zone 1*
Zone 2**
Denotes locations where intact or damaged FAs may be stored.
- Denotes locations where intact or damaged FAs or FFCs may be stored.
Notes:
(])
(2)
(3)
Zone 1 Zone 2 Max. Decay Heat I FA 0.6 1.2 (kW)
Max. Decay Heat I Zone 14.4 9.6 (kW)
Max. Decay Heat/ DSC 24.0 (kW)
The maximum allowable heat load per FFC is 0.8 kW.
Up to 28 damaged FAs may be stored in Zone I and Zone 2 only. When storing damaged FAs in Zone I, intact FAs or Failed Fuel Cans (FFCs) may be stored in the remaining Zone I and Zone 2 locations.
Up to 8 FFCs may be stored in Zone 2 only. When storing FFCs in Zone 2, intact or damaged FAs may be stored in the remaining Zone I and Zone 2 locations.
Figure 1-3 Heat Load Zoning Configuration 2 for the NUHOMS-32PT DSC Standardized NU HOMS System Technical Specifications F-3 CoC 1004 Amendment 15 Application, Revision 2
Figures Zone 1*
Zone 1*
Zone 1
- Zone 1
- Zone 1*
Zone 1
- Zone 1
- Zone 1*
Zone 1
- Zone 1
- Zone 1*
Zone 1
- Zone 1 Zone 1 Zone 1
- Zone 1
- Zone 1
- Zone 1
- Zone 1 Zone 1 Zone 1
- Zone 1
- Zone 1*
Zone 1
- Zone 1
- Zone 1*
Zone 1
- Zone 1*
Zone 1*
Zone 1
- Zone 1*
Zone 1
- Denotes locations where intact or damaged F As may be stored.
Zone 1 Max. Decay Heat/ FA 0.7 (kW)
Max. Decay Heat / Zone 22.4 (kW)
Max. Decay Heat/ DSC 22.4 (kW)
Notes:
(1)
Up to 28 damaged FAs may be stored in Zone I only.
Figure 1-4 Heat Load Zoning Configuration 3 for the NUHOMS-32PT DSC Standardized NU HOMS System Technical Specifications F-4 CoC 1004 Amendment 15 Application, Revision 2
Figures Zone3 Zone 5*
Zone 5*
Zone 3 Zone ~
Zone 2*
Zone 2*
Zone 2*
Zone 2*
Zone U Zone 5*
Zone 2*
Zone 1 Zone 1 Zone 2*
lZone 5*
Zone 5*
Zone 2*
Zone 1 Zone 1 Zone 2*
lZone 5*
Zone -0 Zone 2*
Zone 2*
Zone 2*
Zone 2*
Zone ~
Zone4 Zone 5*
Zone 5*
Zone4
- Denotes where damaged FAs may be stored.
Zone 1 Zone2 Zone3 Zone4 Zones Max. Decay Heat I FA 0.40 0.60 2.21]
1.100 o.Ef2J (kW)
Max. Decay Heat I DSC 24(1)
(kW)
Notes:
(1)
Adjust payload to maintain the total DSC heat load within the specified limit.
(2) ____!l.!!..amaged FAs are loaded in any Zone p or Zone 5jtocations, the maximum allowable decay heat per FA in ZonO is
~
- w.
(3)
Up to~
amaged FAs may be stored in Zones ~
only.
Figure 1-4a Heat Load Zoning Configuration 4 for the NUHOMS -32PT DSC Standardized NU HOMS System Technical Specifications F-5 Coe 1004 Amendment 15 Application, Revision 2
Noles:
(1)
(2)
(3)
Figures C
A A
C C
A B
B A
C A
B B
A A
B B
A C
A B
B A
C C
A A
C F7218E The "C" locations shall be employed when loading up lo 8 FFCs as specified in Table 1-1 g3 The "B " locations and "C" locations shall be employed when loading up lo 16 damaged fuel assemblies as specified in Table l -1g2 The "A " locations, "B" locations and "C" locations shall be employed when loading greater than 16 and up lo 28 damagedfael assemblies as specified in Table l -lg2 Figure 1-4b Location of Damaged and Failed Fuel Assemblies inside 32PT DSC Standardized NU HOMS System Technical Specifications F-6 CoC 1004 Amendment 15 Application, Revision 2
Figures PRA PRA PRA PRA I F5531 Figure 1-5 Required PRA Locations for the NUHOMS-32PT DSC Configuration with Four PRAs Standardized NU HOMS System Technical Specifications F-7 CoC 1004 Amendment 15 Application, Revision 2
Figures Or Figure 1-6 Required PRA Locations for the NUHOMS-32PT DSC Configuration with Eight PRAs Standardized NU HOMS System Technical Specifications F-8 CoC 1004 Amendment 15 Application, Revision 2
Figures PRA PRA PRA PRA PRA PRA PRA PRA PRA PRA PRA PRA I F5530 Figure 1-7 Required PRA Locations for the NUHOMS-32PT DSC Configuration with Sixteen PRAs Standardized NU HOMS System Technical Specifications F-9 CoC 1004 Amendment 15 Application, Revision 2
Figures F675 1
Zone 1 Zone 2 Zone 3 Maximum Decay Heat (kW/FA) 0.7 1
1.3 Maximum Decay Heat per Zone 2.8 10.8 10.4 (kW)
Figure 1-8 Heat Load Zoning Configuration for Fuel Assemblies (with or without Control Components) Stored in NUHOMS-24PHB DSC-Configuration 1 Standardized NU HOMS System Technical Specifications CoC 1004 Amendment 15 Application, Revision 2 F-10
Figures F6726
Zone 1 Zone2 Zone3 Maximum Decay Heat (kW/FA)
N/A N/A 1.3 Maximum Decay Heat per Zone (kW)
N/A N/A 24.0 Figure 1-9 Heat Load Zoning Configuration for Fuel Assemblies (with or without Control Components) Stored in NUHOMS-24PHB DSC-Configuration 2 Standardized NU HOMS System Technical Specifications CoC 1004 Amendment 15 Application, Revision 2 F-11
Figures 3000 2950 E 2900
_/
§: 2850 ci, 2800
- = 2750 "C
~ 2700
....J 2650 C:
0 2600 0
2550 ID Cl) 2500 j:j
- I 2450 0
2400 Cl) 2350
_/
,/
~~
~~
~
__.Ir
~
~
~
2300 4.00 4.05 4.10 4.15 4.20 4.25 4.30 4.35 4.40 4.45 Maximum Initial Enrichment (wt. % U-235)
Linear Interpolation allowed between points.
Initial Boron Loading, ppm Enrichment (when only intact assemblies are loaded)
$4.0 2350 4.1 2470 4.2 2580 4.3 2700 4.4 2790 4.5 2950 Note: The maximum planar average initial enrichment is specified as "initial enrichment."
Figure 1-10 Soluble Boron Concentration vs. Fuel Initial U-235 Enrichment (Intact Fuel) for the NUHOMS 24PHB System Standardized NU HOMS System Technical Specifications CoC 1004 Amendment 15 Application, Revision 2 4.50 F-12
-E C.
C.
3000 2900 2800 C:
"C (II 0
...J 2700 C:
0... s a, 2600
.c
- I 0
Cl) 2500 4
4.05 4.1 4.15 4.2 4.25 4.3 4.35 4.4 4.45 Maximum Initial Enrichment (wt. % U-235)
Linear interpolation allowed between points.
Boron Loading, ppm Initial Enrichment (whenever damaged assemblies are loaded)
- 54.0 2420 4.1 2520 4.2 2650 4.3 2770 4.4 2850 4.5 2985 Note: The maximum planar average initial enrichment is specified as "Initial Enrichment."
Figure 1-1 Oa Soluble Boron Concentration vs. Fuel Initial U-235 Enrichment (Damaged Fuel) for the NUHOMS-24PHB System Standardized NU HOMS System Technical Specifications CoC 1004 Amendment 15 Application, Revision 2 Figures 4.5 F-13
Figures EJE:J E]E]iEJE]
EJEJEJiEJEJE
+---------
EJBB!BBEJ E]E]IE]E]
EJIEJ F5844 Zone 1 Zone 2 Zone 3 Zone4 Maximum Decay Heat (kW/FA) 1 _7(1)
N/A N/A N/A Maximum Decay Heat per Zone (kW) 40.8 N/A N/A N/A (1l The maximum decay heat load allowed for failed fuel assemblies is 1.0 kW/FA.
Figure 1-11 Heat Load Zoning Configuration Number 1 for 24PTH-S and 24PTH-L DSCs Standardized NU HOMS System Technical Specifications F-14 CoC 1004 Amendment 15 Application, Revision 2
Figures 1
ZONE,
111 ZONE z 1
I ZONE, 11 ZONE, 111 ZONE 2 I I ZONE 2 I I zoN E, 11 ZONE, 11 EMPTY /ii EMPTY / I ZONE z/1, oNE 2 /
+---------
[ZONE, 11 ZONE, 1 I EMPTY 111 EMPTY I IZONE, 11 ZONE, 1 I
1 ZONE,
11 ZONE,
111 ZONE,
11 ZONE,
1 B!B F5845 Zone 1 Zone 2 Zone 3 Zone4 Maximum Decay Heat (kW/FA)
N/A 2<1)
N/A N/A Maximum Decay Heat per Zone N/A 40 N/A N/A (kW)
(1l The maximum decay heat load allowed for failed fuel assemblies is 1.0 kW/FA.
Figure 1-12 Heat Load Zoning Configuration Number 2 for 24PTH-S and 24PTH-L DSCs Standardized NU HOMS System Technical Specifications F-15 CoC 1004 Amendment 15 Application, Revision 2
Figures E]iE]
BBiE~B I ZONE, JJ ZONE 311 ZONE 3 Iii ZONE 311 ZONE 311 ZONE,1
+---------
[ZONE, (( ZONE 311ZONE 31!1 ZONE 311 ZONE 311 ZONE 21 BB!BB
[ZONE, J!IZONE, J F5846 Zone 1 Zone 2 Zone 3 Zone 4 Maximum Decay Heat (kW/FA)
N/A 2(fY 1.5 N/A Maximum Decay Heat per Zone N/A 16 24 N/A (kW)
(1> The maximum decay heat load allowed for failed fuel assemblies is 1.0 kW/FA.
Figure 1-13 Heat Load Zoning Configuration Number 3 for 24PTH-S and 24PTH-L DSCs Standardized NU HOMS System Technical Specifications F-16 CoC 1004 Amendment 15 Application, Revision 2
Figures E]EJ E]E]iE]E]
[ZONE 411ZONE 41 IZONE 41il ZONE 41 [ZONE +
ONE 41
-~~-~~-~~+~~-~~-~~-
IZONE 41[zoNE 41 [zoNE 4[1[zoNE 41 [zoNE 41[zoNE 41 BEJ!EJEJ I
ZONE 41!1 ZONE 41 F5890 Zone 1 Zone 2 Zone 3 Zone4 Maximum Decay Heat (kW/FA)
N/A N/A N/A 1.3'11 Maximum Decay Heat per Zone N/A N/A N/A 31.2 (kW)
' 1)The maximum decay heat load allowed for failed fuel assemblies is 0.6 kW/FA.
Figure 1-14 Heat Load Zoning Configuration Number 4 for 24PTH-S and 24PTH-L DSCs Standardized NU HOMS System Technical Specifications F-17 CoC 1004 Amendment 15 Application, Revision 2
E]iEJ BEJiEJB BBEJiEJBB BBEJ1EJBB BBIBB B!E Maximum Decay Heat (kW/FA)
Maximum Decay Heat per Zone kW F5851 Zone 1 N/A N/A Zone 2 Zone 3 N/A 1.5 N/A Note 1 Zone4 1.3 10.4
<1l Fuel assemblies with a maximum heat load of 1.5 kW are permitted in Zone 3 as long as the total of 24 kW/canister maximum heat load is maintained.
2> This configuration is applicable to Basket Types 2A, 2B, or 2C only.
3l The maximum decay heat load allowed for failed fuel assemblies is 0.6 kW/FA. If damaged fuel assemblies are loaded with the failed fuel assemblies in the same basket, the maximum decay heat load allowed for damaged fuel assemblies is also 0.6 kW/FA.
Figure 1-15 Heat Load Zoning Configuration Number 5 for 24PTH-S-LC(2l Standardized NU HOMS System Technical Specifications CoC 1004 Amendment 15 Application, Revision 2 Figures F-18
t:jiEJ l,....ZO_N_E_5_, ~i[ZONE 6 IZONE 5 BEJEJiFFB BEJ~!BEJB ZONE 51 ZONE 6 l!Fl Fl
- J!B F5890 Zone4 Zone5 Zone6 Maximum Decay Heat (kW/FA) 1.3 0.6 2.5 Maximum Decay Heat per Zone (kW) 10.4 4.8 20.0 (t!
Only intact fuel assemblies are allowed for this HLZC.
Figure 1-15a Figures Heat Load Zoning Configuration No. 6 for 24PTH-S and 24PTH-L DSCs with Type 1 Basket Standardized NU HOMS System Technical Specifications F-19 CoC 1004 Amendment 15 Application, Revision 2
Notes:
DiD DDiDD 0[J[Ji[J[J0 D[JD!DDD DD!DD D!D F5616
- 1. Locations identified as "A" are for placement of up to 8 damaged or failed fuel assemblies (balance intact).
- 2. Locations identified as "B" are for placement of up to 4 additional damaged fuel assemblies (Maximum of 12 damaged fuel assemblies allowed, Locations "A" and "B" combined, balance intact).
- 3.
Locations identified as "C" are for placement of up to 12 intact fuel assemblies, including 4 empty slots in the center as shown in Figure 1-12.
Figure 1-16 Location of Failed or Damaged Fuel Inside 24PTH DSC(1H2H3l Standardized NU HOMS System Technical Specifications CoC 1004 Amendment 15 Application, Revision 2 Figures F-20
Figures ZONE 3 ZONE 3 ZONE3 ZONE 3 ZONE3 ZONE 3 ZONE 3 ZONE 3 ZONE 3 ZONE 3 ZONE 3 ZONE 3 ZONE 3 ZONE 3 ZONE 3 ZONE 3 ZONE 3 ZONE 3 ZONE 3 ZONE3 ZONE 3 ZONE3 ZONE 3 ZONE 3 ZONE 3 ZONE3 ZONE 3 ZONE 3 ZONE 3 ZONE 3 ZONE 3 ZONE 3 ZONE 3 ZONE 3 ZONE 3 ZONE 3 ZONE 3 ZONE 3 ZONE 3 ZONE3 ZONE 3 ZONE 3 ZONE3 ZONE 3 ZONE 3 ZONE 3 ZONE3 I ZONE 31 ZONE 3 ZONE 3 ZONE 3 ZONE 3 ZONE 3 ZONE 3 ZONE 3 ZONE 3 ZONE 3 ZONE 3 ZONE 3 ZONE 3 ZONE 3 Zone 1 Zone 2 Zone 3 Zone4 Zone 5 Zone 6 Maximum Decav Heat (kW/FA)
NA NA 0.393 NA NA NA Maximum Decav Heat per Zone (kW)
NA NA 22.0 NA NA NA Maximum Decav Heat per DSC (kW) 22.0 Figure 1-17 Heat Load Zoning Configuration Number 1 for Type 1 or Type 2 61 BTH DSCs Standardized NU HOMS System Technical Specifications F-21 CoC 1004 Amendment 15 Application, Revision 2
Figures ZONES ZONES ZONES ZONE4 ZONE4 ZONE4 ZONE4 ZONE4 ZONE4 ZONE4 ZONE 4 ZONE2 ZONE 2 ZONE 2 ZONE 2 ZONE 2 ZONE4 ZONES ZONE4 ZONE2 ZONE 2 ZONE2 ZONE2 ZONE 2 ZONE4 ZONES ZONES ZONE 4 ZONE2 ZONE2 ZONE2 ZONE2 ZONE2 ZONE4 ZONES ZONES ZONE 4 ZONE2 ZONE2 ZONE 2 ZONE2 ZONE 2 ZONE4 ZONES ZONE4 ZONE2 ZONE2 ZONE 2 ZONE2 ZONE 2 ZONE4 ZONE 4 ZONE4 ZONE4 ZONE4 ZONE4 ZONE4 ZONE4 ZONE S ZONES ZONES Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 Maximum Deca NA 0.35 NA 0.48 0.54 NA Maximum Deca NA 8.75 NA 11.52 6.48 NA Maximum Deca 22.0 (1)
Adjust payload to maintain total DSC heat load within the specified limit Figure 1-18 Heat Load Zoning Configuration Number 2 for Type 1 or Type 2 618TH DSCs Standardized NU HOMS System Technical Specifications F-22 CoC 1004 Amendment 15 Application, Revision 2
Figures ZONE2 ZONE 2 ZONE2 ZONE2 ZONE2 ZONE2 ZONE2 ZONE 2 ZONE 2 ZONE 2 ZONE2 ZONE2 ZONE 2 ZONE 2 ZONE 2 ZONE2 ZONE2 ZONE 2 ZONE2 ZONE2 ZONE2 ZONE2 ZONE 2 ZONE2 ZONE2 ZONE2 ZONE2 ZONE2 ZONE2 ZONE2 ZONE2 ZONE2 ZONE2 ZONE2 ZONE2 ZONE 2 ZONE2 ZONE2 ZONE2 ZONE2 ZONE 2 ZONE2 ZONE 2 ZONE2 ZONE2 ZONE2 ZONE2 ZONE2 ZONE2 ZONE 2 ZONE2 ZONE2 ZONE2 ZONE2 ZONE2 ZONE2 ZONE 2 ZONE2 ZONE 2 ZONE2 ZONE2 Zone 1 Zone 2 Zone 3 Zone4 Zone 5 Zone6 Maximum Decay Heat (kW/FA)
NA 0.35 NA NA NA NA Maximum Decay Heat per Zone (kW)
NA 19.4 NA NA NA NA Maximum Decay Heat per DSC (kW) 19.4 Figure 1-19 Heat Load Zoning Configuration Number 3 for Type 1 or Type 2 618TH DSCs Standardized NU HOMS System Technical Specifications F-23 CoC 1004 Amendment 15 Application, Revision 2
Figures ZONE 5 ZONE 5 ZONE 5 ZONE4 ZONE4 ZONE4 ZONE4 ZONE4 ZONE4 ZONE4 ZONE4 ZONE2 ZONE2 ZONE2 ZONE2 ZONE 2 ZONE4 ZONE 5 ZONE4 ZONE2 ZONE 1 ZONE1 ZONE 1 ZONE 2 ZONE4 ZONE 5 ZONE 5 ZONE4 ZONE2 ZONE1 ZONE 1 ZONE 1 ZONE 2 ZONE4 ZONE5 ZONE 5 ZONE4 ZONE2 ZONE 1 ZONE 1 ZONE 1 ZONE2 ZONE4 ZONE 5 ZONE4 ZONE2 ZONE2 ZONE2 ZONE 2 ZONE 2 ZONE4 ZONE4 ZONE4 ZONE4 ZONE4 ZONE4 ZONE4 ZONE4 ZONE 5 ZONE 5 ZONE 5 Zone 1 Zone 2 Zone 3 Zone4 Zone 5 Zone 6 Maximum Decay Heat (kW/FA) 0.22 0.35 NA 0.48 0.54 NA Maximum Decav Heat per Zone (kW) 1.98 5.60 NA 11.52 6.48 NA Maximum Decav Heat per DSC (kW) 19.4\\'I (1> Adjust payload to maintain total DSC heat load within the specified limit.
Figure 1-20 Heat Load Zoning Configuration Number 4 for Type 1 or Type 2 618TH DSCs Standardized NU HOMS System Technical Specifications F-24 CoC 1004 Amendment 15 Application, Revision 2
Figures ZONE 5 ZONE 5 ZONE5 ZONE 5 ZONE5 ZONE 5 EJ ZONE 5 ZONE 5 ZONE 5 ZONE 5 ZONE 5 ZONE 5 ZONE 5 ZONE 5 ZONE 5 ZONE 5 ZONE 5 ZONE5 ZONE 5 ZONE 2 EJ ZONE2 ZONE 5 ZONE5 ZONE 5 ZONE 5 ZONE5 ZONE 5 ZONE2 ZONE2 ZONE 2 ZONE 5 ZONE 5 ZONE 5 ZONE 5 ZONE 5 ZONE5 ZONE2 ZONE2 ZONE2 ZONE 5 ZONE 5 ZONE5 ZONE 5 ZONE 5 ZONE5 ZONE 5 ZONE 5 ZONE 5 ZONE5 ZONE 5 ZONE5 ZONE 5 ZONE 5 ZONE 5 ZONE 5 ZONE 5 ZONE 5 ZONE 5 ZONE 5 Zone 1 Zone2 Zone 3 Zone4 Zone 5 Zones Maximum Decay Heat (kW/FA)
NA 0.35 NA NA 0.54 NA Maximum Decay Heat per Zone (kW)
NA 3.15 NA NA 28.08 NA Maximum Decay Heat per DSC (kW) 31.2\\ 'I (1l Adjust payload to maintain total DSC heat load within the specified limit.
Figure 1-21 Heat Load Zoning Configuration Number 5 for Type 2 61 BTH DSCs Standardized NU HOMS System Technical Specifications F-25 Coe 1004 Amendment 15 Application, Revision 2
Figures ZONE 5 ZONE 5 ZONE 5 ZONE4 ZONE4 ZONE4 ZONE4 ZONE4 ZONE4 ZONE4 ZONE4 ZONE6 ZONE6 ZONE6 ZONE6 ZONE 6 ZONE4 ZONE 5 ZONE4 ZONE6 ZONE 1 ZONE 1 ZONE 1 ZONE6 ZONE4 ZONE 5 ZONE 5 ZONE4 ZONE6 ZONE 1 ZONE 1 ZONE 1 ZONE6 ZONE4 ZONES ZONE 5 ZONE4 ZONE6 ZONE 1 ZONE 1 ZONE 1 ZONE6 ZONE4 ZONE 5 ZONE4 ZONE6 ZONE6 ZONE6 ZONE6 ZONE 6 ZONE4 ZONE4 ZONE4 ZONE4 ZONE4 ZONE4 ZONE4 ZONE4 ZONE 5 ZONE 5 ZONE 5 Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 Maximum Deca 0.22 NA NA 0.48 0.54 0.70 Maximum Deca 1.98 NA NA 11.52 6.48 11.20 Maximum Deca 31.2 (1) Adjust payload to maintain total DSC heat load within the specified limit.
Figure 1-22 Heat Load Zoning Configuration Number 6 for Type 2 618TH DSCs Standardized NU HOMS System Technical Specifications F-26 CoC 1004 Amendment 15 Application, Revision 2
Figures ZONES ZONES ZONES ZONES ZONES ZONES ZONES ZONES ZONES ZONES ZONES ZONE4 ZONE4 ZONE4 ZONE4 ZONE4 ZONES ZONES ZONES ZONE4 ZONE4 ZONE4 ZONE4 ZONE4 ZONES ZONES ZONES ZONES ZONE4 ZONE4 ZONE4 ZONE4 ZONE4 ZONES ZONE S ZONES ZONES ZONE 4 ZONE4 ZONE4 ZONE4 ZONE4 ZONES ZONES ZONES ZONE4 ZONE4 ZONE4 ZONE4 ZONE4 ZONES ZONES ZONES ZONES ZONES ZONES ZONES ZONES ZONES ZONES ZONES Zone 1 Zone 2 Zone 3 Zone4 Zone 5 Zone 6 Maximum Decay Heat (kW/FA)
NA NA NA 0.48 0.54 NA Maximum Decay Heat per Zone (kW)
NA NA NA 12.00 19.44 NA Maximum Decay Heat per DSC (kW) 31.2l'I (1) Adjust payload to maintain total DSC heat load within the specified limit.
Figure 1-23 Heat Load Zoning Configuration Number 7 for Type 2 618TH DSCs Standardized NU HOMS System Technical Specifications F-27 CoC 1004 Amendment 15 Application, Revision 2
Figures ZONE 5 ZONE 5 ZONE5 ZONE4 ZONE4 ZONE4 ZONE4 ZONE4 ZONE4 ZONE4 ZONE4 ZONE3 ZONE3 ZONE 3 ZONE 3 ZONE 3 ZONE4 ZONE 5 ZONE4 ZONE 3 ZONE2 ZONE2 ZONE 2 ZONE 3 ZONE4 ZONE 5 ZONE 5 ZONE4 ZONE3 ZONE2 ZONE2 ZONE 2 ZONE 3 ZONE4 ZONE5 ZONE 5 ZONE4 ZONE 3 ZONE2 ZONE2 ZONE 2 ZONE 3 ZONE4 ZONE5 ZONE4 ZONE 3 ZONE 3 ZONE 3 ZONE 3 ZONE 3 ZONE4 ZONE4 ZONE4 ZONE4 ZONE4 ZONE4 ZONE4 ZONE4 ZONE 5 ZONE 5 ZONE5 Zone 1 Zone 2 Zone 3 Zone4 Zones Zone 6 Maximum Decay Heat (kW/FA)
NA 0.35 0.393 0.48 0.54 NA Maximum Decay Heat per Zone (kW)
NA 3.15 6.288 11.52 6.48 NA Maximum Decay Heat per DSC (kW) 27.41*1 (1l Adjust payload to maintain total DSC heat load within the specified limit.
Figure 1-24 Heat Load Zoning Configuration Number 8 for Type 2 618TH DSCs Standardized NU HOMS System Technical Specifications F-28 CoC 1004 Amendment 15 Application, Revision 2
Note 1:
Note 2:
Note 3:
C A
B C
B B
C C
C C
C C
C C
C C
C C
C B
B C
A B
C C
A Corner Locations See Note 1 C
Interior/Edge Locations See Note 3 C
C C
C C
C C
C C
C C
C C
C C
C C
C B
B A
B B
C C
C C
C C
B B
B A
Interior Locations See Note 2 Figures C
C C
When loading up to 4 damaged or 4 failed assemblies, these must be placed in corner "A" locations, and the remaining locations "B" and "C" shall be loaded with intact fuel. If fewer than 4 damaged or 4 failed assemblies are to be stored, the remaining "A" locations may be loaded with intact fuel provided they meet the respective damaged or failed enrichment limits of Table 1-1w1. Damaged and failed fuel shall not be mixed, i.e., up to four damaged assemblies may be stored, or up to four failed assemblies may be stored in "A" locations.
If loading more than four damaged assemblies, place first four damaged assemblies in the corner "A" locations per Note 1, and up to 12 additional damaged assemblies in these interior "B" locations, with the remaining intact in a 61 BTH Basket. The maximum lattice average initial enrichment of assemblies (damaged or intact stored in the 2x2 cells) is limited to the "Five or More Damaged Assemblies" column of Table 1-1w. For the Type 2 DSC containing failed fuel assemblies, this enrichment is limited to the "and up to 12 Damaged Assemblies" column of Table 1-1w1.
If loading more than 16 damaged assemblies, place the first 57 damaged assemblies in the interior/edge "C" and the interior "B" locations. Place the remaining four intact or damaged assemblies in the corner "A" locations. The maximum lattice average initial enrichments of assemblies is limited to the "Up to 4 Intact Assemblies" or "Up to 4 Damaged Assemblies" column of Table 1-1 x.
Figure 1-25 Location of Damaged and Failed Fuel Assemblies inside 618TH DSC Standardized NU HOMS System Technical Specifications F-29 CoC 1004 Amendment 15 Application, Revision 2
Figures 4
4 4
4 4
3 3
3 4
4 4
2 2
2 2
2 4
4 3
2 1
1 1
2 3
4 4
3 2
1 1
1 2
3 4
4 3
2 1
1 1
2 3
4 4
2 2
2 2
2 4
4 4
3 3
3 4
4 4
4 4
Zone 1 Zone 2 Zone 3 Zone 4 Maximum Decay Heat 0.393 0.48 0.35 0.35 (kW/FA)
Maximum Decay Heat 3.54 7.68 4.2 8.4 per Zone (kW)
Maximum Decay Heat 22.0<1) per DSC (kW)
Note 1: Adjust payload to maintain total canister heat load within the specified limit.
Figure 1-25a Heat Load Zoning Configuration No. 9 for Type 1 or Type 2 618TH DSC Standardized NU HOMS System Technical Specifications F-30 CoC 1004 Amendment 15 Application, Revision 2
Figures I
4 I 4 I 4 I 4
4 3
3 3
4 4
4 2
2 2
2 2 D 4
3 2
1 1
1 2
3 4
4 3
2 1
1 1
2 3
4 4
3 2
1 1
1 2
3 4
4 2
2 2
2 2
4 4
4 3
3 3
4 4
4 4
4 Zone 1 Zone 2 Zone 3 Zone 4 Maximum Decay Heat 0.393 0.48(2) 1.2d2) 0.48(2)
(kW/FA)
Maximum Decay Heat 3.54 7.68 14.4 11.52 per Zone (kW)
Maximum Decay Heat 31 _2(1) per DSC (kW)
Note 1: Adjust payload to maintain total canister heat load within the specified limit.
Note 2: If the maximum decay heat per SFA in Zone 3 is greater than 0. 9 kW, the maximum decay heat per FA in Zone 2 and Zone 4 shall be less than or equal to 0.393 kW.
Figure 1-25b Heat Load Zoning Configuration No. 10 for Type 2 618TH DSC Standardized NU HOMS System Technical Specifications F-31 CoC 1004 Amendment 15 Application, Revision 2
Figures Zone6 Zone6 Zone 6 Zone6 Zone6 Zone 6 Zone6 Zone 6 Zone6 Zone6 Zone6 Zone6 Zone 6 Zone 6 Zone6 Zone6
- denotes location where INTACT or DAMAGED FUEL ASSEMBLY can be stored.
Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 Max. Decay Heat/ FA 0.6 N/A NIA N/A 1 _3(1) 1.5 (kW)
Max. Decay Heat I Zone 2.4 N/A N/A N/A 15.6 24.0 (kW)
Max. Decay Heat I DSC 40.8(2)
(kW)
Notes:
1:
1.2 kW per FA is the maximum decay heat allowed for damaged fuel assemblies.
2:
Adjust payload to maintain 40.8 kW heat load.
Figure 1-26 Heat Load Zoning Configuration Number 1 for 32PTH1-S, 32PTH1-M and 32PTH1-L DSCs (Type 1 Baskets)
Standardized NU HOMS System Technical Specifications F-32 CoC 1004 Amendment 15 Application, Revision 2
Notes:
Figures Zone 3
- Zone 3 Zone 3
- Zone 3 *
- denotes location w here INTACT or DAMAGED FUEL ASSEMBLY can be stored.
Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 Max. Decay Heat / FA N/A N/A 0.96(2) 0.98(2)
N/A N/A (kW)
Max. Decay Heat / Zone N/A N/A 3.84 27.44 N/A N/A (kW)
Max. Decay Heat / DSC 31.2(1)
(kW) 1:
Adjust payload to maintain 31.2 kW heat load.
2:
The fuel qualification table corresponding to 1.0 kW/FA shall be used to determine burnup, cooling time, and enrichments corresponding to these heat loads.
Figure 1-27 Heat Load Zoning Configuration Number 2 for 32PTH1-S, 32PTH1-M and 32PTH1-L DSCs (Type 1 or Type 2 Baskets)
Standardized NU HOMS System Technical Specifications F-33 CoC 1004 Amendment 15 Application, Revision 2
Notes:
Zone 2 **
Zone 2 Zone 2 Zone 2 **
Zone 2 **
Zone 2
- Zone 2 *r*
Zone 2 *r*
Zone 2
- Zone 2 **
Zone2 Zone 2 */**
Zone 2.
Zone 2.
Zone 2 *I**
Zone 2 Zone 2 Zone 2 *1..
Zone 2
- Zone 2
- Zone 2 *r-Zone2 Zone 2 **
Zone 2
- Zone 2 *r*
Zone 2 *r*
Zone 2
- Zone 2 **
Zone 2 **
Zone2 Zone2 Zone 2 **
- denotes location where INTACT or DAMAGED FUEL ASSEMBLY can be stored.
- denotes location where FAILED FUEL can be stored.
Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 Max. Decay Heat I FA NIA 0.8 N/A N/A N/A N/A (kW)
Max. Decay Heat I Zone N/A 24.0 N/A N/A N/A N/A (kW)
Max. Decay Heat I DSC 24.0'1><2)
(kW) 1:
Adjust payload to maintain total canister heat load within the specified limit.
2:
If FAILED FUEL is stored, the maximum canister heat load is 12.8 kW.
Figures 3:
If FAILED FUEL is stored at any location denoted by **, INTACT FUEL ASSEMBLIES shall not be stored in any Zone 2 location, and in addition DAMAGED FUEL ASSEMBLIES shall not be stored in any location denoted by *.
4:
If FAILED FUEL is stored at any location denoted by **, the remaining ** locations shall be loaded with either FAILED FUEL, Dummy Assemblies or remain empty.
Figure 1-28 Heat Load Zoning Configuration Number 3 for 32PTH1-S, 32PTH1-M and 32PTH1-L DSCs (Type 1 or Type 2 Baskets)
Standardized NU HOMS System Technical Specifications F-34 CoC 1004 Amendment 15 Application, Revision 2
Zone 4a Zone6 Zone6 Zone 4a Zone 4a Zone Zone 2*
Zone 2*
Zone Zone 4a Sa*/**
Sa*/**
Zone6 Zone 2*
Zone 1*
Zone 1*
Zone 2*
Zone6 Zone6 Zone 2*
Zone 1*
Zone 1*
Zone 2*
Zone6 Zone 4a Zone Zone 2*
Zone 2*
Zone Zone 4a Sa*/**
Sa*/**
Zone 4a Zone6 Zone6 Zone 4a
- denotes an interior location where a DAMAGED FUEL ASSEMBLY can be stored.
- denotes location where failed fuel can (FFC) can be stored.
Figures
- denotes a periphery location where a DAMAGED FUEL ASSEMBLY can be stored.
Zone 1 Zone 2 Zone 3 Zone 4a Zone 5a Zone 6 Max. Decay Heat /FA (kW) 0.6 0.8 N/A 1.0 1.2<1) 1.5 Max. Decay Heat /Zone (kW) 2.4 6.4 N/A 8.0 4.8 12 Max. Decay Heat/ DSC (kW) 31.2 kW <2l Notes: (1) The maximum allowable heat load per FFC is 0.8 kW.
(2) Adjust payload to maintain total canister heat load within the specified limit.
(3) DAMAGED FUEL ASSEMBLIES may be loaded in locations denoted by
- or***, but not both. If a DAMAGED FUEL ASSEMBLY is loaded in a location denoted by ***,
FFC shall not be stored.
Figure 1-28a Heat Load Zoning Configuration No. 4 for 32PTH1 -S, 32PTH1 -M and 32PTH1-L DSCs (Type 1 or Type 2 Baskets)
Standardized NU HOMS System Technical Specifications F-35 CoC 1004 Amendment 15 Application, Revision 2
Figures Zone 7 Zone 7 Zone 7 Zone 7 Zone 7 Zone 7 Zone 7 Zone 7 Zone 7 Zone 7 Zone 7 Zone 7 Zone 7 Zone 7 Zone 7 Zone 7 Zone 7 Zone 7 Zone 7 Zone 7 Zone 7 Zone 7 Zone 7 Zone 7 Zone 7 Zone 7 Zone 7 Zone 7 Zone 7 Zone 7 Zone 7 Zone 7 Zone 7 Max. Decay Heat !FA (kW)
- 1. 1 Max. Decay Heat I Zone (kW) 35.2 Max. Decay Heat I DSC (kW) 35.2 Figure 1-28b Heat Load Zoning Configuration No. 5 for 32PTH1-S, 32PTH1-M and 32PTH1-L DSCs (Type 1 Basket)
Standardized NU HOMS System Technical Specifications F-36 CoC 1004 Amendment 15 Application, Revision 2
Figures Zone 7 Zone 7 Zone 7 Zone 7 Zone 7 Zone 8 Zone 8 Zone 8 Zone 8 Zone 7 Zone 7 Zone 8 Zone 7 Zone 7 Zone 8 Zone 7 Zone 7 Zone8 Zone 7 Zone 7 Zone 8 Zone 7 Zone 7 Zone 8 Zone 8 Zone 8 Zone 8 Zone 7 Zone 7 Zone 7 Zone 7 Zone 7 Zone 7 Zone 8 Max. Decay Heat !FA (kW)
- 1. 1 1.3 Max. Decay Heat I Zone (kW) 22.0 15.6 Max. Decay Heat I DSC (kW) 37.6 Figure 1-28c Heat Load Zoning Configuration No. 6 for 32PTH1-S, 32PTH1-M and 32PTH1-L DSCs (Type 1 Basket)
Standardized NU HOMS System Technical Specifications F-37 Coe 1004 Amendment 15 Application, Revision 2
Figures 2 [J[J 2
2 2 [EJ[J 2
[J 2 2
1 2
2 2
2 2
2 1
1 1
2 2
2 2
2 1
1 1
1 1
2 2
2 2
2 1
1 1
2 2
2
[EJ[J[J 2 2
2
[J[J 2 2 [J 2 2
2 2 [J Heat Zone Level Zone 1 Zone 2 Max. Deca Heat/FA k 0.3 0.17 Number of FAs/Zone 13 48 Max. Deca Heat/Zone (k 3.9 8.2 12.0 Figure 1-29 Heat Load Zone Configuration for the 618T DSC Contained in an OS197L TC Standardized NU HOMS System Technical Specifications F-38 CoC 1004 Amendment 15 Application, Revision 2
Figures 2
2 2
2 2
2 1
1 2
2 2
1 1
1 1
2 2
1 1
1 1
2 2
2 1
1 2
2 D
2 2
2 Heat Zone Level Zone 1 Zone 2 Max. Deca Heat/FA k 0.6 0.4 Number of FAs/Zone 12 20 Max. Deca Heat/Zone 7.2 8.0 13.0
<1) Maximum decay heat load allowed in the OS197L TC.
Figure 1-30 Heat Load Zone Configuration for the 32PT DSC Contained in an OS197L TC Standardized NU HOMS System Technical Specifications F-39 CoC 1004 Amendment 15 Application, Revision 2
Max. Decay Heat (kW/FA/3l Number of Fuel Assemblies(1l Max. Decay Heat per Zone (kW)(3l Max. Decay Heat per DSC (kW)
Z4 Z3 Z4 I
I Z4 23 22 23 Z4 I
I 23 Z3 21 23 23 Z4 23 22 23 Z4 Z4 23 Z4 Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 0.10 0.27 0.30 0.40 0.55 1
2 10 16 16 0.10 0.54 3.0 6.4 8.8 26.0(2)(3)
(1) Total number of fuel assemblies is 69.
Figures Zone 6 0.45 24 10.8
(
2
> Adjust payload to maintain the total DSC heat load within the specified limit.
(3> Reduce the maximum decay heat to 70% of the listed values for Lacrosse fuel assembly. The total decay heat for Lacrosse fuel assembly is 18.2 kW per DSC.
Figure 1-31 Heat Load Zoning Configuration Number 1 for 698TH DSCs Standardized NU HOMS System Technical Specifications F-40 CoC 1004 Amendment 15 Application, Revision 2
Z4 Z4 Z4 Z4 Z3 23 23 Z4 Z4 23 22 22 22 23 Z4 Z4 Z3 22 21 22 23 Z4 Z4 23 22 22 22 23 24 Z4 23 23 Z3 Z4 Z4 Z4 Z4 Zone 1 Zone 2 Zone 3 Zone 4 Max. Decay Heat (kW/FAt>
0.25 0.0 (1) 0.40 0.60 Number of Fuel 1
0 12 24 Assemblies(2>
Max. Decay Heat per Zone (kW)(4l 0.25 0
4.8 14.4 Max. Decay Heat 26.0(3) (4) per DSC (kW)
(1> Aluminum dummy assemblies replace the fuel assemblies in Zone 2.
<2> Total number of fuel assemblies is 61.
Figures Zone 5 0.50 24 12.0 (3l Adjust payload to maintain the total DSC heat load within the specified limit.
<4> Reduce the maximum decay heat to 70% of the listed values for Lacrosse fuel assembly.
The total decay heat for Lacrosse fuel assembly is 18.2 kW per DSC.
Figure 1-32 Heat Load Zoning Configuration Number 2 for 698TH DSCs Standardized NU HOMS System Technical Specifications F-41 CoC 1004 Amendment 15 Application, Revision 2
Z4 Z4 Z4 a1 Z4 23 23 23 Z4 I
I Z4 23 22 22 22 23 Z4 I
I Z4 23 22 21 22 23 Z4 I
I Z4 23 22 22 22 23 Z4 a1 1a Z4 23 23 23 Z4 Z4 Z4 Z4 Zone 1 Zone 2 Zone 3 Zone 4 Max. Decay Heat (kW/FA)<4) 0.25 0.0 <1) 0.40 0.60 Number of Fuel 1
0 12 24 Assemblies<2)
Max. Decay Heat per Zone (kW)<4) 0.25 0
4.8 14.4 Max. Decay Heat 29.2 (3) (4) per DSC (kW)
<1) Aluminum dummy assemblies replace the fuel assemblies in Zone 2.
<2) Total number of fuel assemblies is 61.
Figures Zone 5 0.50 24 12.0
<3) Adjust payload to maintain the total DSC heat load within the specified limit.
4
) Reduce the maximum decay heat to 70% of the listed values for Lacrosse fuel assembly.
The total decay heat for Lacrosse fuel assembly is 20.4 kW per DSC.
Figure 1-33 Heat Load Zoning Configuration Number 3 for 698TH DSCs Standardized NU HOMS System Technical Specifications F-42 CoC 1004 Amendment 15 Application, Revision 2
Figures 24 24 Z4 23 23 23 23 23 24 23 22 22 22 23 Z4 Z4 23 22 21 22 23 24 24 23 22 22 22 23 24 23 23 23 23 23 24 24 Z4 Zone 1 Zone 2 Zone 3 Zone4 Zone 5 Max. Decay Heat (kW/FA)(3l 0.0 (1>
0.45 0.0 (1) 0.70 0.60 Number of Fuel 0
8 0
20 24 Assemblies(2>
Max. Decay Heat per Zone (kW)(3>
0 3.6 0
14.0 14.4 Max. Decay Heat 32.0<3>
per DSC (kW)
(1
> The fuel compartment in Zone 1 remains empty. Aluminum dummy assemblies replace the fuel assemblies in Zone 3.
(Z) Total number of fuel assemblies is 52.
(3
> Reduce the maximum decay heat to 70% of the listed values for Lacrosse fuel assembly. The total decay heat for Lacrosse fuel assembly is 22.4 kW per DSC.
Figure 1-34 Heat Load Zoning Configuration Number 4 for 698TH DSCs Standardized NU HOMS System Technical Specifications CoC 1004 Amendment 15 Application, Revision 2 F-43
Figures 24 Z4 24 23 23 23 23 23 24 23 22 22 22 23 Z4 24 23 22 21 22 23 24 24 23 22 22 22 23 24 23 23 23 23 23 Z4 Z4 24 Zone 1 Zone 2 Zone 3 Zone4 Zone 5 Max. Decay Heat (kW/FAf l 0.22 0.35 0.393 0.70 0.488 Number of Fuel 1
8 16 20 24 Assemblies<1l Max. Decay Heat per Zone (kW)<2>
0.22 2.80 6.29 14.00 11.71 Max. Decay Heat 35_0<2) per DSC (kW)
<1> Total number of fuel assemblies is 69.
2l Reduce the maximum decay heat to 70% of the listed values for Lacrosse fuel assembly.
The total decay heat for Lacrosse fuel assembly is 24.5 kW per DSC.
Figure 1-35 Heat Load Zoning Configuration Number 5 for 698TH DSC Standardized NU HOMS System Technical Specifications F-44 CoC 1004 Amendment 15 Application, Revision 2
Figures Z4 Z3 Z3 mi im 22 22 22 22 22 I
I Z3 22 21 21 21 22 Z3 I
I Z3 22 21 21 21 22 Z3 I
I Z3 22 21 22 21 22 Z3 1m 22 Z2 22 22 22 Z4 Z3 Z3 Zone 1 Zone 2 Zone 3 Zone4 Max. Decay Heat (kW/FAf>
0.22 0.35 0.393 0.35 Number of Fuel 9
16 20 24 Assemblies<1>
Max. Decay Heat per Zone (kWi2>
1.98 5.6 7.86 8.40 Max. Decay Heat 24.0<2>
per DSC (kW) 1> Total number of fuel assemblies is 69.
'2> Reduce the maximum decay heat to 70% of the listed values for Lacrosse fuel assembly. The total decay heat for Lacrosse fuel assembly is 16.8 kW per DSC.
Figure 1-36 Heat Load Zoning Configuration Number 6 for 698TH DSC Standardized NU HOMS System Technical Specifications CoC 1004 Amendment 15 Application, Revision 2 F-45
Figures 1* tttj I-3 4
3 2**
4 4 ornrn cffi EB 1*
4 4
4 rn 3
4 4
3 2**
1*
Configurations<1l 1, 2, 3, and 4 Any one of these three sets of corner locations shall only be utilized to load up to four damaged assemblies with the remaining intact in a 69BTH Basket. The maximum lattice average initial enrichment of fuel assemblies (damaged or intact stored in either set of cells for configuration 1 or configuration 2, or set of cells for configuration 3) is limited to the "up to 4 damaged assemblies" column of Table 1-1 kk.
Following the placement of damaged fuel assemblies in either configuration 1 or 2, the remaining configuration 2 or configuration 1 locations shall be used to load up to 4 additional damaged assemblies, with the remaining intact in a 69BTH Basket. The maximum lattice Note (1) average initial enrichment for these fuel assemblies (damaged or intact stored in configuration 2 or configuration 1 cells available) is limited to the "5 to 8 damaged assemblies" column of Table 1-1 kk.
Following the placement of eight damaged fuel assemblies in the set of corner locations marked with a"*" (configuration 1 cells) and a"**" (configuration 2 cells), the locations in configuration 4 cells or configuration 3 cells shall be used to load up to sixteen additional damaged assemblies, with the remaining intact in a 69BTH Basket. The maximum lattice average initial enrichment for all 24 fuel assemblies (damaged or intact stored in these 24 locations) is limited to the "9 to 24 Damaged Assemblies" column of Table 1-1 kk.
Figure 1-37 Location of Damaged Fuel Assemblies Inside 698TH DSC Standardized NU HOMS System Technical Specifications F-46 CoC 1004 Amendment 15 Application, Revision 2
Figures ZS ZS ZS ZS ZS ZS ZS 24 24 24 ZS ZS ZS ZS 23 23 23 23 23 ZS ZS ZS 24 23 22 22 22 23 24 ZS Z5 24 23 22 21 22 23 24 Z5 ZS 24 23 22 22 22 23 24 ZS Z5 Z5 23 23 23 23 23 ZS ZS ZS ZS 24 24 24 ZS ZS ZS ZS ZS Z5 ZS Zone Zone 2 Zone 3 Zone4 Zone 5 1 (3)
Max. Decay Heat (kW/FA) <4l 0
0.35 0.40 0.9 0.5 No. of Fuel 0
8 16 12 32 Assemblies <1l Max. Decay Heat 0
2.80 6.4 10.8 16.0 per Zone (kW)
Max. Decay Heat 35.0(2) <4) per DSC (kW)
(1) Total number of fuel assemblies is 68 for HLZC #7 (2) Adjust payload to maintain the total DSC heat load within the specified limit (3) Zone 1 does not require an aluminum dummy assembly.
(4) Reduce the maximum decay heat to 70% of the listed values for Lacrosse fuel assembly. The total decay heat for Lacrosse fuel assembly is 24.5 kW per DSC Figure 1-38 Heat Load Zoning Configuration No. 7 for 698TH DSCs Standardized NU HOMS System Technical Specifications CoC 1004 Amendment 15 Application, Revision 2 F-47
Figures 0
24 24 BG 23 23 24*
24 000 22 23 24 24 000 22 23 24 24 000 22 23 24 000 23 24*
24 24 24
- Denotes locations where damaged fuel assembly can be stored.
Zone 1 Zone 2 Zone 3 Zone4 Max. decay heat 0.40 0.40 0.60 0.70 (kW/FA)
Number of fuel 1
8 12 16 assemblies Max. decay heat 0.4 3.2 7.2 11.2 per zone (kW)
Max. decay heat 22.0 per DSC (kW)
Figure 1-39 Heat Load Zoning Configuration Number 2 for 37PTH-S and 37PTH-M DSCs Standardized NU HOMS System Technical Specifications F-48 CoC 1004 Amendment 15 Application, Revision 2
24 24 24 25*
23 23 23 25*
24 23 22 22 22 23 24 24 23 22 21 22 23 24 24 23 22 22 22 23 24 25*
23 23 23 25*
24 24 24
- Denotes locations where either an intact or damaged fuel assembly can be stored.
Zone Zone Zone Zone Zone 1
2 3
4 5
Max. decay heat 0.40 0.40 0.70 1.20 1.20 (kW/FA)
Number of fuel 1
8 12 12 4
assemblies Max. decay heat 0.4 3.2 8.4 14.4 4.80 per zone (kW)
Max. decay heat 30.0<1>
per DSC (kW)
\\ I/ Adjust payload of fuel assemblies to maintain the total DSC heat load within the specified limit.
Figure 1-40 Heat Load Zoning Configuration Number 3 for 37PTH-S and 37PTH-M DSCs Standardized NUHOMS System Technical Specifications CoC 1004 Amendment 15 Application, Revision 2 Figures F-49
Figures I
--P~
Figure 1-41 Required PRA Locations for the NUHOMS-37PTH DSC Configuration with Five PRAs Standardized NU HOMS System Technical Specifications F-50 CoC 1004 Amendment 15 Application, Revision 2
I p~
I I --.-
I PftA Figure 1-42 Figures Required PRA Locations for the NUHOMS-37PTH DSC Configuration with Nine PRAs Standardized NU HOMS System Technical Specifications F-51 CoC 1004 Amendment 15 Application, Revision 2