December 1
997 Mr. T. F. Plunkett President-Nuclear Division Florida Power and Light Company P.O. Box 14000 Juno Beach, Florida 33408-0420 See attached sheet
SUBJECT:
ST. LUCIE UNITS 1 AND 2; TURKEY POINT UNITS 3 AND 4 - SAFETY EVALUATIONON PROPOSED QUALITYASSURANCE PROGRAM DESCRIPTION CHANGES (TAC NOS. M98670, M98671, M98672, AND M98673)
Dear Mr. Plunkett:
On April 29, 1997, you requested review and approval of a proposed change to the Florida Power and Light Company's (FPL) Topical Quality Assurance Report (FPLTQAR 1-76A).
The proposed change was considered a reduction in commitment pursuant to 10 CFR 50.54(a)(3) and involved a reduction in the amount of organizational detail given in Section 1.0 titled "Organization".
As documented in the enclosed safety evaluation, we have determined that the proposed change is not acceptable since it does not adequately satisfy the regulatory requirement to clearly delineate in writing the functional responsibilities of organizations performing activities on safety-related equipment.
Sincerely,
/S/
Frederick J
~ Hebdon, Project Director Project Directorate II-3 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation Docket Nos. 50-250, 50-251, 50-335, 50-389
Enclosure:
Safety Evaluation cc w/enclosure:
See next page Document Name: G:TURKEY>98672.QA
+~ RC~ IIlEIPE ri'iw NAME RCrotea DATE 11/2 /97 OFFICE PM:PDII-3 BCI i ns 11/2997 1
97 LA:PDII-3 P:P II-3 OGC 12/ f/97 D:PDII-3 FHebdon 12/I997 COPY e
No Yes/No e
No Yes/No Yes/No Yes o
9'80105024b 97i2i5 PDR ADOCK 05000250 P
PDR OFFICI L
ECORD COPY IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII
jPS RE00 "o
Cy 1~
~
C O
I 4p qO
+)t **+
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 2055&0001 December 15, 1997 Mr. T. F. Plunkett President - Nuclear Division Florida Power and Light Company P.O. Box 14000 Juno Beach, Florida 33408-0420
SUBJECT:
ST. LUCIE UNITS 1 AND 2; TURKEY POINT UNITS 3 AND 4-SAFETY EVALUATIONON PROPOSED QUALITYASSURANCE PROGRAM DESCRIPTION CHANGES (TAC NOS. M98670, M98671, M98672, AND M98673)
Dear Mr. Plunkett:
On April 29, 1997, you requested review and approval of a proposed change to the Florida Power and Light Company's (FPL) Topical Quality Assurance Report (FPLTQAR 1-76A).
The proposed change was considered a reduction in commitment pursuant to 10 CFR 50.54(a)(3) and involved a reduction in the amount of organizational detail given in Section 1.0 titled "Organization".
As documented in the enclosed safety evaluation, we have determined that the proposed change is not acceptable since it does not adequately satisfy the regulatory requirement to clearly delineate in writing the functional responsibilities of organizations performing activities on safety-related equipment.
Sincerely, 9~%~ iJ Frederick J. Hebdon, Project Director Project Directorate II-3 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation Docket Nos. 50-250, 50-251, 50-335, 50-389
Enclosure:
Safety Evaluation cc w/enclosure: See next page
~Di rib ion Docket File PUBLIC Turkey Pt. Reading St. Lucie Reading B. Boger OGC ACRS S. Black R. Gramm K. Heck L. Trocine, EDO K. Landis, R-II T. Harris (E-mail SE to TLH3)
~ Mr. T. F. Plunkett Florida Power and Lig t Company CC:
Senior Resident Inspector St. Lucie Plant U.S.
Nuclear Regulatory Commission 7585 S.
Hwy AlA Jensen
- Beach, Florida 34957 Joe Myers, Director Division of Emergency Preparedness Department of Community Affairs 2740 Centerview Drive Tallahassee, Florida 32399-2100 M. S.
Ross, Attorney Florida Power 8 Light Company P.O.
Box 14000 Juno Beach.
FL 33408-0420 J
John T. Butler, Esquire Steel.
Hector and Davis 4000 Southeast Financial Center Miami, Florida 33131-2398 Robert J.
Hovey, Site Vice President Turkey Point Nuclear Plant Florida Power and Light Company 9760 SW. 344th Street Florida City, FL 33035 Douglas Anderson County Administrator St. Lucie County 2300 Virginia Avenue Ft. Pierce, Florida 34982 Mr. J. Scarola Plant General Manager St. Lucie Nuclear Plant 6351 South Ocean Drive Jensen
- Beach, Florida 34957 Mr. Gary E. Hollinger Licensing Manager Turkey Point Nuclear Plant 9760 SW. 344th Street Florida City, FL 33035 Mr. Bill Passetti Office of Radiation Control Department of Health and Rehabilitative Services 1317 Winewood Blvd.
Tallahassee.
LUCIE POIT TURKEY POINT PLANT Regional Administrator, Region II U.S. Nuclear Regulatory Commission 61 Forsyth Street, SW., Suite 23T85 Atlanta.
GA 30303-3415 Mr. H.
N. Paduano, Manager Licensing 5 Special Programs Florida Power and Light Company P.O.
Box 14000 Juno Beach, Florida 33408-0420 J.
A. Stall, Site Vice President St. Lucie Nuclear Plant 6351 South Ocean Drive Jensen
- Beach, Florida 34957 Attorney General Department of Legal Affairs The Capitol Tallahassee, Florida 32304 Senior Resident Inspector Turkey Point Nuclear Generating Station U.S. Nuclear Regulatory Commission P.O.
Box 1448 Homestead, Florida 33090 Plant Manager Turkey Point Nuclear Plant Florida Power and Light Company 9760 SW. 344th Street Florida City, FL 33035 Armando Vidal County Manager Metropolitan Dade County 111 NW 1 Street, 29th Floor Miami, Florida 33128 Mr. Kerry Landis U.S. Nuclear Regulatory Commission 61 Forsyth Street.
SW., Suite 23T85 Atlanta.
GA 30303-3415 E. J.
Weinkam Licensing Manager St. Lucie Nuclear Plant 6351 South Ocean Drive Jensen
- Beach, Florida 34957