attachment Page 1 of 4 L-96-262 The Core Operating Limits Report (COLR) for Turkey Point Unit 3 Uprated Cycle 15 has been prepared in accordance with the requirements of Technical Specification
.6'. 1.7
~
The Technical Specifications (TS) affected by this report are:
3.1.3.6 3 ~ 2 ~ 1 3.2.2 3.2.3 Control Rod Insertion Limits Axial Flux Difference (AFD)
Heat Flux Hot Channel Factor
- FO(Z)
Nuclear Enthalpy Rise Hot Channel Factor F~H The Control rod Insertion Limits, AFD, FO(Z), K(Z), and F~H have been developed using the NRC approved methodology specified in Technical Specification 6.9. 1.7.
TS 3. 1.3.6 Control Rod Insertion Limits The control rod banks shall be limited in physical insertion as shown on page 2 for All Rods Out = 228 steps withdrawn.
TS 3.2. 1 Axial Flux Difference The AFD limits are provided on page 3.
TS 3.2.2 Heat Flux Hot Channel Factor
- FO(Z)
FO = 2.35 L
K(Z) is provided on page 4.
TS 3.2.3 Nuclear Enthalpy Rise Hot Channel Factor RTP F~H
= 1.64 PF~H = 0.3 96i02iOiqh 9hiOiO PDR ADOCK 05000250 P
attachment Page 2 of 4
Rod Bank Insertion Limits versus Thermai power ARO =
2A~
Steps withdrawn, Overlap = 100 Steps Turkey Point Unit 3 - Uprated Cyde 15 228 216 (55.2,212 63.5I225) 180 156
~
144
~
132
~
120 108 96 o
84 72 O
60 48 36 24 12 0
10 kc 40 50 60 Pircont Reactor Power 70
attachment Page 3 of.4 L-96-262 Axial Flux Difference as a Function of Rated Thermal Power Turkey Point Unit 3 - Uprated Cycle 15
(-1,100)
(+7,1 g
5 80 W
I 60 0NA EPTAbLE 0
TlON
(-X,50)
ACCEPT OPERA N
(+2,50)
ACCEPT OPERAT1O
-10 0
10 AxlNRux ONerenco (%)
attachment Page 4 of 4 K(Z) Normalized Fo(Z) as a Function of Core Hejgbt Turkey Point Unit 3 - Uprated Cycle 15 1.0 01000 (6,1.000) 0.9 0.7 0.6 0.5 0
5 6
7 Core Height (ft)
O.
I
~ ~s
~
p