ACCESSION NBR:9603060238 DOC.DATE: 96/02/27 NOTARIZED:
NO FACIL:50-250 Turkey Point Plant, Unit 3, Florida Power and Light C 50-251 Turkey Point Plant, Unit 4, Florida Power and Light C 50-335 St. Lucie Plant, Unit 1, Florida Power a Light Co.
50-389 St. Lucie Plant, Unit 2, Florida Power
& Light Co.
AUTH.NAME AUTHOR AFFILIATION CRAIG,K.R.
Florida Power s Light Co.
RECIP.NAME RECIPIENT AFFILIATION Document Control Branch (Document Control Desk)
SUBJECT:
Forwards fitness-for-duty program performance data for period ending 951231.
DISTRIBUTION CODE:
A021D COPIES RECEIVED:LTR ENCL SIZE:
TITLE: "Semiannual Fitness for Duty Program Performance Rept/Data" NOTES:
DOCKET 05000250 05000251 05000335 05000389 T
RECIPIENT ID CODE/NAME PD2-1 PD NORRISgJ INTERNAL: ACRS NRR/DRPM/PSGB NUDOCS-ABSTRACT EXTERNAL: NOAC COPIES LTTR ENCL 1
1 1
1 1
1 2
2 1
1 1
1 RECjPIENT ID CODE/NAME CROTEAUiR FILE CEDER 0%
NRR/DSSA/SPSB RGN2 NRC PDR COPIES LTTR ENCL 1
1 1
1 1
1 1
1 1
1 0
R D
U NOTE TO ALL "RIDS" RECIPIENTS:
PLEASE HELP US TO REDUCE WASTE)
CONTACT THE DOCUMENT CONTROL DESK, ROOM OWFN 5D-5(EXT. 415-2083)
TO ELIMINATE YOUR NAME FROM DISTRIBUTION LISTS FOR DOCUMENTS YOU DON'T NEEDI TOTAL NUMBER OF COPIES REQUIRED:
LTTR 12 ENCL
.12
pp Florida Power & Light Company, P.O. Box 14000, Juno Boach, FL 33408-0420 FEB 27 1996 L-96-47 10 CFR 26.71 U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555
Subject:
Turkey Point Units 3 and 4 Docket Nos. 50-250 and 50-251 St. Lucie Units 1 and 2 Docket Nos. 50-335 and 50-389 Semi-Annual Fitness-For-Duty Pro m Performance Da Gentlemen:
In accordance with 10 CFR 26.71(d),
please find attached the fitness-for-duty program performance data for the six (6) month period ending December 31, 1995.
Should you have any questions, please contact us.
Very truly yours, K. R. Craig Acting Vice Presi ent Nuclear Engineering and Licensing KRC/spt Attachment cc:
Stewart D. Ebneter, Regional Administrator, USNRC, Region II Senior Resident Inspector, USNRC, Turkey Point Plant Senior Resident Inspector, USNRC, St. Lucie Plant OgOOOS 9603060238 960227
(
PDR ADOCK 05000250 R
\\ (
<r 1 r k
~4ll W
Fitness for Duty Program
,Performance Data Personnel Subject to 10CFR Part 26 Florida Power & Li ht Company St. Lucie Plant Location Arthur R. Cummin s
Contact Name December 31 1995 6 Months Ending 407 694-3573 Phono (Inofude Area Code)
Cutoffs:
Screeruconfirmation (ng/ml) 0 Appendbr Ato 10 CFR Part 26 Marijuana 50/10 Amphetamines 1000/500 00fy150 Phencycfir5ne 2$25 0plates
- SfXV300, Afoohof (%BAG)
.04%
TESTING RESULTS LICENSEE EMPLOYEES LONG-TERM CONTRACTOR PERSONNEL SHORT-TERM CONTRACTOR PERSONNEL Average Number with Unescorted Access CATEGORIES
¹ TESTED 1475
¹ POSITIVE
¹ TESTED 216
¹ POSITIVE
¹ TESTED 538
¹ POSITIVE Pre-Access For Cause Random Follow-up Other Post Accident Observed Behavior 292 421 49 66 987 163 13 20 TOTAL 764 73 0
1165 23
Breakdown of Confirmed Positive Tests for Specific Substances
- 'arijuana Amphetamines Phencycidine Refusal to Test 2
3 4
Long-Term Contractors Short-Term Contractors PSL TOTALS 15 21
- All of the positive drug tests listed above exceeded the DHHS/NRC cutoff levels.
MANAGEMENTACTlONS ST. LUCIE PLANT Fitness for Duty Reportable Event Qn August 21, 1995, a confirmed positive random test result was received on a supervisor for Cocaine.
Telephone notification to the NRC was made at 7:35pm on August 21, 1995 (from the Turkey Point Plant). The individual was selected from the St. Lucie Plant random pool and the test was conducted at the Turkey Point Plant. A review was conducted, with negative results of the Subject's past work activities for a period prior to the test.
Fitness for Duty Program Performance Data Personnel Subject to 10CFR Part 26 Florida Power & Li ht Company Turke Point Plant Location Arthur R. Cummin s
Contact Name December 31 1995 8 Months Ending 407 694-3573 Phone (Include Area Code)
Cutothr:
ScreenCcnfirmation (ng/ml) 0 Appendix A to 10 CFR Part 26 5$10 Amphelamines 1000/500 300/150 Phencyclidine 25/25 Optates 300300 Alcohol (%BAG) 04%
TESTING RESULTS LICENSEE EMPLOYEES LONG-TERM CONTRACTOR PERSONNEL SHORT-TERM CONTRACTOR PERSONNEL Average Number with Unescorted Access CATEGORIES
¹ TESTED 1099
¹ POSITIVE
¹ TESTED 237
¹ POSITIVE
¹ TESTED 334
¹ POSITIVE Pre-Access For Cause Random Follow-up Other Post Accident Observed Behavior 233 333 26 0
81 1085 83 10 32 TOTAL 594 81 1185 38
Breakdown-of Confirmed Positive Tests for Specific Substances Ucensee Employees Long-Term Contractors Cocatne Refusal to Test 2
3 4
Short-Term Contractors PTN TOTALS 20 21 13 Total 42 ~
- All of the positive drug tests listed above exceeded the DHHS/NRC cutoff levels.
~
~
~ A MANAGENIENTACTIONS TURKEYPOINT PLANT 1
On September 26, 1995 a data input error occurred that resulted in 11 individuals obtaining access authorization but were not entered into the Fitness for Duty/Access Authorization data system to be made available for random chemical testing.
All individuals were temporary workers and when all errors were identified the individuals had left the plant due to the completion of the outage.
The cause was human error by the individual responsible for data input. The immediate corrective action was to have each individual's supervisor provide a written behavioral observation review. There were no behavioral observation concerns identified. Additionally, the data input process was modified to require the first access authorization entry to be made in the Fitness for Duty/Access Authorization system prior to activating the individual's authorized site access.