ATTACHMENT 4 TURKEY POINT UNIT 3 CYCLE 14 CORE OPERATING LIMITS REPORT 9407210M4 940719 PDR'DOCK 05000250 P

PDR

I

L-94-128 Attachment 4

CORE OPERATING LIMITS REPORT The Core Operating Limits Report (COLR) for Turkey Point Unit 3 Cycle 14 has been prepared in accordance with the requirements of Technical Specifications 6.9.1.7.

The Technical Specification affected by this report is:

3.2.1 3.1.3.6 3/4.2.2 Axial Flux Difference (AFD)

Control Rod Insertion Limits Heat Flux Hot Channel Factor Fg(Z)

The AFD, K(Z) and Rod Bank Insertion Limits have been developed using the NRC approved methodology specified in Technical Specification 6.9.1.7.

These Limits are provided in the attached figures.

L-94-128 Attachment 4

AXIAL FLUX DIFFERENCE AS A FUNCTION OF RATED THERMAL POWER (TURKEY POINT UNIT 3 CYCLE 14)

(4,100)

(+7,100) g 80 60 Q

I 0

C g

40 UNACCEPTABLE OPERATION (40,50)

(+25,50)

UNACCEPTABLE OPERATtON ACCEPTABLE 0PERATlON

-50 40

-30

-20

-10 0

10 20 30 40 50 Axial Flux Dii/erence (%)

L-94-128 Attachment 4

ROD BANK INSERTION LIMITS VS.

THERMAL POWER (TURKEY POINT UNIT 3 CYCLE 14) 216 (sans) 192

,171)

I (O,1Oij BANK 0 24 0

10 20 X

40 50 60 70 N

90 100 a RHEO THERMAL POWER

L-94-128 Attachment 4

K(Z) NORMALIZED Fg(Z)

AS A FUNCTION OF CORE HEIGHT (TURKEY POINT UNZT 3 CYCLE 14) 1.0 (6.0,1.0)

(10.8,0.94) 0.9 03 0.7 O

12.0,0.647)

N o~

I 0g 03 0.1 0.0 0

1 2

3 i

5 6

7 cm HEtom Q.)

8 9

10 11 12