Requests one-time Exemption from Requirements of 10CFR50,App E, Emergency Planning & Preparedness for Production & Utilization Facilities
ML17352A483
Person / Time
Site: Turkey Point  
Issue date: 03/23/1994
From: Plunkett T
FLORIDA POWER & LIGHT CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
L-94-63, NUDOCS 9403280088
Download: ML17352A483 (11)


Text

ACCELERATED DISTRIBUTION DEMONSTPATION SYSTEM

, ~

REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)

ACCESSION NBR:9403280088 DOC.DATE: 94/03/23 NOTARIZED:

NO FACIL:50-250 Turkey Point Plant, Unit 3, Florida Power and Light C 50-251 Turkey Point Plant, Unit 4, Florida Power and Light C AUTH.NAME AUTHOR AFFILIATION PLUNKETT,T.F.

Florida Power

& Light Co.

RECIP.NAME RECIPIENT AFFILIATION Document Control Branch (Document Control Desk)

DOCKET g

05000250 05000251

SUBJECT:

Requests one-time exemption from requirements of 10CFR50,App E,

"Emerc!ency Planning 6 Preparedness for Production 6

D Utilizata.on Facilities."

DISTRIBUTION CODE: A045D COPIES RECEIVED:LTR ENCL SIZE:

TITLE: OR Submittal:

Emergency Preparedness

Plans, Imple ent'g Procedures, C /

NOTES:

RECIPIENT ID CODE/NAME PD2-2 PD INTERNAL: AEOD/DOA/IRB NUDOCS-ABSTRACT EXTERNAL: NRC PDR COPIES LTTR ENCL 1

1 1

1 1

1 1

1 RECIPIENT ID CODE/NAME CROTEAU,R NRR DRSS/PEPB 01 NSIC COPIES LTTR ENCL 1

1 1

1 1

1 1

1 D

D D

NOTE TO ALL"RIDS" RECIPIENTS:

D D

PLEASE HELP US TO REDUCE WASTE! CONTACT THE DOCUMENT CONTROL DESK, ROOM Pl-37 (EXT. 20079) TO ELIMINATEYOUR NAMEFROM DISTRIBUTION LIKES FOR DOCUMENTS YOU DON'T NEED!

TOTAL NUMBER OF COPIES REQUIRED:

LTTR' ENCL 8

0

~

t PAL MAR 2 8 1995 L-94-63 10 CFR 50.12 10 CFR 50 Appendix E

U.

S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D.C.

20555

Subject:

Turkey Point Units 3 and 4

Docket Nos.

50-250 and 50-251 Re uest for Exem tion 10 CFR 50 A endix E

In accordance with the provisions of Title 10 of the Code of Federal Regulations Section 50.12 (10 CFR 50.12),

"Specific Exemptions," Florida Power 6 Light Company (FPL) requests a one-time exemption from the requirement of 10 CFR 50 Appendix E, "Emergency Planning and Preparedness for Production and Utilization Facilities," to conduct an annual U.

S. Nuclear Regulatory Commission (NRC) evaluated emergency preparedness exercise in calendar year 1994 for Turkey Point Units 3 and 4.

During calendar year 1994, consistent with current regulatory

guidance, Turkey Point will be conducting the drills specified in its emergency plan.

Those drills include, but are not limited to, a radiological monitoring drill, two health physics drills, a

medical drill involving offsite transport, and multiple communication drills.

Furthermore, at least one integrated drill will be conducted to exercise the FPL Emergency

Response

Organization for Turkey Point, and allow state and local agencies the opportunity to participate in the drill.

Section 7.1.4 of the Turkey Point Radiological Emergency

Plan, 10 CFR 50.47(b) (14),

and 10 CFR Appendix E,Section IV.F(2),

require a nuclear power plant operator to conduct an annual emergency preparedness exercise that provides state and local governments the opportunity to jointly exercise their respective radiological emergency response plans.

On December 15,

1993, FPL's Turkey Point Plant, in conjunction with the State of
Florida, and Dade and Monroe counties, conducted a successful full participation emergency preparedness exercise that was evaluated by the Federal Emergency Management Agency (FEMA) and the NRC.

Turkey Point has conducted annual NRC evaluated exercises in the past and there have been no violations identified during an evaluated exercise or Emergency Preparedness Inspection since 1989.

Turkey Point is scheduled to conduct a

full participation FEMA evaluated exercise in February

1995, 14 months after the last full participation exercise.

FPL has discussed the need for an NRC evaluated emergency preparedness exercise for Turkey Point Units 3 and 4 in 1994 with both state and local governments and it has been agreed that an

~5@, p p6 cy4P328P088 940323 an FPL Group company t

'Dp

/DOCK 050002~0I F

PDR',

)

~,

l I

l g

~

1

L-94-63 Page 2

NRC evaluated exercise would not significantly enhance their programs.

In light of the successful December 1993 FEMA

exercise, and the preparation for the February 1995 FEMA
exercise, the state and local governments are more than satisfied to participate in Turkey Point's 1994 drills.

FPL requests a one-time exemption from the requirement of 10 CFR 50 Appendix E, to conduct an annual NRC evaluated emergency preparedness exercise in calendar year 1994 for Turkey Point Units 3 and 4.

The attachment to this letter provides the regulatory basis for this exemption.

As discussed in the attachment, the conducting of an evaluated emergency preparedness exercise in 1994 is not necessary to assure the health and safety of the publica The exemption from conducting the 1994 evaluated exercise would not decrease Turkey Point Plant's, nor the community's, ability to respond to an accident.

Additionally, the cost savings, reduction of burden on the operating staff, and flexible drill schedule would make the exemption beneficial.

We would appreciate your timely review of this request prior to May 13, 1994, to eliminate the administrative preparation requirements for the currently scheduled July 27,

1994, Turkey Point Plant NRC evaluated emergency preparedness exercise.

If you have any questions regarding this request, please contact us

~

Very truly yours, T. F. Plunkett Vice President Turkey Point Plant Attachment TFP/OIH cc:

Stewart D. Ebneter, Regional Administrator, Region II, USNRC T. P.

Johnson, Senior Resident Inspector,
USNRC, Turkey Point Plant W. A. Passetti,.

Florida Department of Health and Rehabilitative Services

Attachment Page 1 of 6

EXEMPTION RE VEST BACKGROUND Pursuant to 10 CFR 50.12, Florida Power

& Light Co.( FPL) requests a one-time exemption from the requirement to conduct an annual Nuclear Regulatory Commission (NRC) evaluated emergency preparedness exercise at Turkey Point Units 3 and 4.

Specifically, FPL requests a one-time exemption from the provision requiring each site to annually exercise its emergency plan as specified in 10 CFR Part 50, Appendix E,Section IV.F(2).

Generically, this requirement has been interpreted as the conduct of an integrated exercise scheduled for NRC evaluation.

The 1994 NRC evaluated emergency preparedness exercise for Turkey Point Units 3 and 4 is presently scheduled for July 27, 1994.

DISCUSSION An emergency preparedness exercise was last held on December 15, 1993.

FPL's Turkey Point Plant, in conjunction with the State of

Florida, Dade and Monroe counties, conducted a successful full participation emergency preparedness exercise that was evaluated by the Federal Emergency Management Agency (FEMA) and the NRC.

There were no negative findings, violations, weaknesses, or follow-up items identified as a result of this evaluation.

The December 15, 1993, full participation emergency preparedness exercise demonstrated the sufficiency of the emergency response capability and emergency preparedness program at the Turkey Point Plant.

Additionally, Turkey Point is scheduled to conduct a full participation FEMA evaluated exercise in February of 1995, 14 months after the last full participation exercise.

During calendar year 1994, consistent with current regulatory

guidance, Turkey Point will be conducting the drills specified in its emergency plan.

Those drills include, but are not limited to, a radiological monitoring drill, two health physics drills, a

medical drill involving offsite transport, and multiple communication drills'urthermore, at least one integrated drill will be conducted to exercise the FPL Emergency

Response

Organization for Turkey Point, and allow state and local agencies the opportunity to participate in the drill.

Each of these drills will be evaluated, at a minimum, by an FPL controller/evaluator organization.

Items identified during the drills as deficiencies will be corrected as detailed in the NRC's regulations.

The Turkey Point Plant 1994 schedule of emergency preparedness drills and exercises is sufficient and appropriate to assess and confirm the capability of the various organizations involved to respond to a radiological emergency, and obviate the need to conduct a full participation evaluated exercise in calendar year 1994.

Attachment Page 2 of 6

JUSTIFICATION 10 CFR 50.12 states that the Commission may grant exemptions from the requirements of the regulations contained in 10 CFR 50 provided that:

(1) the exemption is authorized by law, (2) the exemption will not present an undue risk to the public health and

safety, (3) the exemption is consistent with the common defense and security, and (4) special circumstances as defined in 10 CFR 50.12(a)(2) are present.

The re uested Exem tion is Authorized b Law No law exists which would preclude the approval of this exemption request.

Also, this exemption, if approved, would not create a conflict with any existing law.

2.

The Re uested Exem tion Does Not Present an Undue Risk to the Public Health and Safet There have been no violations identified during an evaluated exercise or Emergency Preparedness Inspection since 1989.

On December 15,

1993, FPL's Turkey Point Plant, in conjunction with the state of Florida, and Dade and Monroe
counties, conducted a successful full participation emergency preparedness exercise that was evaluated by FEMA and the NRC.

The next FEMA evaluated exercise for the Turkey Point Plant is scheduled for February

1995, 14 months since the last evaluated exercise.

Approval of this one-time exemption from the requirement to conduct the annual NRC evaluated emergency preparedness exercise for calendar year<1994 does not represent a

degradation in the ability of FPL to respond to a

radiological emergency at the Turkey Point Plant.

During calendar year

1994, consistent with current regulatory
guidance, Turkey Point will be conducting the drills specified in its emergency plan.

Those drills include, but are not limited to, a radiological monitoring drill, two health physics drills, a medical drill involving offsite transport, and multiple communication drills.

Furthermore, at least one integrated drill will be conducted to exercise the FPL Emergency

Response

Organization for Turkey Point, and allow state and local agencies the opportunity to participate in the drill.

Each of these drills will be evaluated, at a minimum, by an FPL controller/evaluator organization.

Items identified during the drills as deficiencies will be corrected as detailed in the NRC's regulations.

The Turkey Point Plant 1994 schedule of emergency preparedness drills and exercises is sufficient

Attachment Page 3 of 6

and appropriate to assess and confirm the capability of the various organizations involved to respond to a radiological emergency, and obviate the need to conduct a full participation evaluated exercise in calendar year 1994.

3.

The Re uested Exem tion Will Not Endan er the Common Defense and Securit The common defense and security is not an issue in this exemption request.

4.

S ecial Circumstances as Defined in 10 CFR 50.12 a

2 The following special circumstances pursuant to 10 CFR 50.12(a) (2) are identified as applicable to this exemption request:

Item (ii) -"Application of the regulation in the particular circumstances would not serve the underlying purpose of the rule or is not necessary to achieve the underlying purpose of the rule."

There have been no violations identified during an evaluated exercise or Emergency Preparedness Inspection since 1989.

Additionally, on December 15,

1993, FPL's Turkey Point Plant, in conjunction with the State of Florida, and Dade and Monroe counties, conducted a successful full participation emergency preparedness exercise that was evaluated by FEMA and the NRC.

There were no negative findings, violations, weaknesses, or follow-up items identified as a result of this evaluation.

The December 15, 1993, full participation emergency preparedness exercise and Turkey Point's previous record have demonstrated the sufficiency of the emergency response capability and emergency preparedness program at the Turkey Point Plant.

In addition, Turkey Point is scheduled to conduct a full participation FEMA evaluated exercise in February of 1995, only 14 months after the last full participation exercise.

During calendar year 1994, consistent with current regulatory guidance, Turkey Point will be conducting the drills specified in its emergency plan Those drills include, but are not limited to, a radiological monitoring drill, two health physics drills, a medical drill involving offsite transport, and multiple communication drills.

Furthermore, at least one integrated drill will be conducted to exercise the FPL Emergency

Response

Organization for

Attachment Page 4 of 6

Turkey Point, and allow state and local agencies the opportunity to participate in the drill.

Each of these drills will be evaluated, at a minimum, by an FPL controller/evaluator organization.

Items identified during the drills as deficiencies will be corrected as detailed in the NRC's regulations.

This schedule of emergency preparedness drills and exercises is appropriate to assess and confirm the capability of the various organizations involved to respond to a radiological emergency without the conduct of an NRC evaluated exercise.

Therefore, the conducting of a 1994 NRC evaluated emergency preparedness exercise is not necessary to demonstrate the sufficiency of the emergency response capability and emergency preparedness program at the Turkey Point Plant.

Item (iii) "Compliance would result in undue hardship or other costs that are significantly in excess of those contemplated when the regulation was adopted, or that are significantly in excess of those incurred by others similarly situated."

An emergency preparedness exercise was last held on December 15I 1993 FPL's Turkey Point Plant, in conjunction with the State of Florida, Dade and Monroe counties, conducted a

successful full participation emergency preparedness exercise that was evaluated by FEMA and the NRC.

The 1994 NRC evaluated emergency preparedness exercise for Turkey Point Units 3 and 4 is presently scheduled for July 27,

1994, seven months from the last full participation exercise.

The next FEMA evaluated exercise for the Turkey Point Plant is planned for February 1995.

The conducting of the 1994 NRC evaluated emergency preparedness exercise would result in three evaluated emergency preparedness exercises within a 14 month period for Turkey Point Units 3 and 4.

FPL's Turkey Point Plant will have two refueling outages in

1994, one in the spring and one in the fall. Additionally, FPL's St. Lucie Plant has refueling outages scheduled for both units this year, and successfully conducted an evaluated exercise in February 1994.

The performance of a 1994 NRC evaluated emergency preparedness exercise at Turkey Point puts undue demands on the site and corporate response organizations.

The corporate site organization participates in both the St. Lucie and Turkey Point plant emergency preparedness exercises and has already successfully demonstrated acceptable performance at the St. Lucie February 1994 evaluated exercise.

Attachment Page 5 of 6

FPL has discussed the need for an evaluated emergency preparedness exercise for Turkey Point Units 3 and 4 in 1994 with both state and local governments and it has been agreed that such an exercise is not necessary in 1994.

In light of the successful December 1993 FEMA exercise, the preparation for the February 1995 FEMA exercise, and the fact that there have been no violations identified during an evaluated exercise or Emergency Preparedness Inspection since

1989, the state and local governments are more than satisfied to participate in Turkey Point's 1994 drills.

Item (v)

"The exemption would provide only temporary relief from the applicable regulation and the licensee has made good faith efforts to comply with the regulation."

A one-time exemption is not permanent, but rather, provides relief only for 1994.

Turkey Point is scheduled to conduct a full participation FEMA evaluated exercise in February of

1995, only 14 months after the last full participation evaluated exercise of December 1993.

During calendar year 1994, consistent with current regulatory guidance, Turkey Point will be conducting the drills specified in its emergency plan.

Those drills include, but are not limited to, a radiological monitoring drill, two health physics

drills, a medical drill involving offsite transport, and multiple communication drills.

Furthermore, at least one integrated drill will be conducted to exercise the FPL Emergency

Response

Organization for Turkey Point, and allow state and local agencies the opportunity to participate in the drill.

Each of these drills will be evaluated by an FPL controller/evaluator organization.

Items identified during the drills as deficiencies will be corrected as detailed in the NRC's regulations.

This schedule of emergency preparedness drills and exercises is sufficient and appropriate to assess and confirm the capability of the various organizations involved to respond to a radiological emergency and obviate the need to conduct an NRC evaluated emergency preparedness exercise on calendar year 1994.

Based on the above, FPL has shown good faith efforts to comply with the regulation.

CONCLUSION With the successful completion of the December 1993 full participation evaluated emergency preparedness

exercise, and the fact that there have been no violations identified during an

~

~

~

~

. ~

Attachment Page 6 of 6

evaluated exercise or Emergency Preparedness Inspection since

1989, we conclude that the sufficiency of the emergency preparedness program has been demonstrated and the provisions of the plan have been satisfied.

The 1994 schedule of emergency preparedness drills and exercises is sufficient and appropriate to assess and confirm the capability of the various organizations involved to respond to a radiological emergency and obviate the need to conduct an NRC evaluated emergency preparedness exercise on calendar year 1994.

At least one integrated drill will be conducted in 1994 to exercise the FPL Emergency

Response

Organization for Turkey Point, and allow state and local agencies the opportunity to participate in the drill. Additionally, Turkey Point is scheduled to conduct a full participation FEMA evaluated exercise in February

1995, 14 months after the last full participation exercise Therefore, the intent of the regulation is met.

An NRC evaluated emergency preparedness exercise during 1994 is not necessary to further demonstrate the adequate protective measures in place in the event of a radiological emergency, and to establish reasonable assurance against undue risk to the health and safety of the public.

Approval of this one-time exemption will avoid duplication of

efforts, and unnecessary use of Federal,
State, local, and FPL resources.

Performance of the July 27,

1994, Turkey Point Plant evaluated
exercise, given our specific circumstances and previous performance, represents undue regulatory burden without additional benefit to public safety.

For these

reasons, we conclude that the requested exemption will not present an undue risk to the public and safety and is consistent with the common defense and security, and meets the special circumstances described in 10 CFR 50.12(a) (2).