TURKEY POINT PLANT UNIT 4 1993 INSERVICE INSPECTION REPORT Executive Summar The inservice inspection examinations perfozmed during this outage and the cumulative total of exams meet the requirements of ASME Section XI. No unacceptable conditions or reportable indications were found.

100% of the A, B, and C steam generator tubes were eddy current tested. No tubes were plugged during this out'age.

The NIS-2 forms discuss the repairs and replacements which took place during the 1993 refueling/maintenance outage.

Visual examination and functional testing of snubbers was completed in accordance with ASME Section XI and Technical Specifications. Visual examinations did not reveal any failures. There were three snubber failures in the functional test sample, and no failures in the expanded samples.

The inservice inspection summary tables detail the examinations performed during the second outage of the third period of the second interval.

Selected class 2 and 3 piping were hydrostatically tested in accordance with Section XI of the ASME Boiler and Pressure Vessel Code. All leakage found during the testing was from mechanical joints. Each leak was addressed by repair oz adjustment under the control of a Plant Work Order.

93082b03ii 930820 PDR ADOCK 05000251 6 PDR

TURKEY POINT UNIT 4 1993 REFUELING OUTAGE Form NIS-1 Owners'ata Report for Insert.ce Inspects.ons

FORM NIS-1 OWNERS DATA REPORT FOR INSERVICE INSPECTIONS Page 1 of 13 Florida Power and Light Company, P.O. Box 029100, Miami, Florida 33102

2. Plant: Turkey Point Nuclear Power Plant, P.O. Box 3088, Florida City, Florida 33034
3. Plant Unit: 4
4. Owner Certificate of Authorization (if required) ~N A
5. Commercial Service Date  : Se tember 7 1973
6. National Board Number for Unit: ~N A
7. Components Inspected:

Component or anufacturer oranufacturer State or ational ppurtenance Installer or Installer Serial Province Board No. 0 0 ~

Steam Generator C estinghouse 16A-6341-3 /A -776 FSGT-2993 4E210C eactor Coolant estinghouse 5-618J713 /A /A Pump A eactor Coolant estinghouse 6-618J713 /A /A Pump B egenerative Heat Sentry 4E200 /A /A Exchanger Equipment esidual Heat Bechtel 4E206A /A /A Exchanger A Excess Letdown Bechtel 4E202 /A /A eat Exchanger esidual Heat Bechtel 4P210A /A /A emoval Pump A esidual Heat Bechtel 4P210B /A /A emoval Pump B

f

1. Owneri Florida Power and Light Company, P.O. Box 029100, Hiami, Florida 33102 20 Plant: Turkey Point Nuclear Power Plant, P.O. Box 30M, Florida City, Florida 33034
3. Plant Unit: 4 4~ Owner Certificate of Authorization (if required) ~NA
5. Cottttercial Service Date: Se tember 7 1973
6. National Board Number for Unit: ~NA Component or anufacturer oranufacturer State or ational ppurtenance or Installer Serial Installer Province Board No. 0 ~ 0~

eactor Coolant Bechtel /A /A /A System Piping 4it RC 1401 4>>-RC-1402 4>>-RC-1405 4>>-RC-1406 12>>-RC-1401 27.5>>-RCS-1406 27.5>>-RCS-1407 27.5>>-RCS-1409 esidual Heat, Bechtel /A /A /A emoval Piping 6't-SI-2402 6't-SI-2403 8>>-RHR-1401 8it-RHR-1404 8>>-SI-2403 8>>-SI-2407 8't-SI-2408 10't-SI-1402 10it-RHR-2401 1PII RHR 24P2 10't-RHR-2404 10>>-SI-2403 12>>-RHR-2402 14>>-RHR-2401 14>>-RHR-2402 14tt RHR 2403 14>>-RHR-2405 14>>-RHR-2406

1 ~ Owner: Florida Power and Light Company, P.O. Box 029100, Miami, Florida 33102

2. Plant: Turkey Point Nuclear Power Plant, P.O. Box 30BB, Florida City, Florida 33034 3~ Plant Unit: 4
4. Owner Certificate of Authorization (if required) ~N A
5. Comcercial Service Date : Se tember 7 1973
6. National Board Number for Unit: ~N A Component or anufacturer oranufacturer State or ational ppurtenance or Installer Serial Installer Province Board No. 0 ~ 0~

Safety Injection Bechtel /A /A /A Piping 2>>-SI-1401 2>>-SI-1402 2>>-SI-1406 8>>-SI-2401 8>>-SI-2405 10>>-SI-2401 10>>-SI-2402 16>>-SI-2401 Chemical and Bechtel /A /A olume Control Piping 1 5>>-CH-1401 2>>-CH-1402 2>> -CH-14 04 2>>-CH-1405 3>>-CH-1401 3>>-CH-1402 3>>-CH-1403 Steam Generator Bechtel /A /A /A Blowdown Piping 6>>-BDA-2401 6>>-BDB-2402 6>>-BDC-2403 ain Steam Piping Bechtel /A /A /A 26>>-MSA-2401 26>>-MSB-2402 Containment Spray Bechtel /A /A /A Piping 6>>-CS-2402 6>>-CS-2404

NIS-1 OWNERS DATA REPORT FOR INSERVICE INSPECTIONS Page 4 of 13 Owner: Florida Power and Light Company, P.O. Box 029100, Miami, Florida 33102

2. Plant: Turkey Point Nuclear Power Plant, P.O. Box 3088, Florida City, Florida 33034
3. Plant Unit: 4
4. Owner Certificate of Authorization (if required) ~N A
5. Comnercial Service Date : Se tember 7 1973
6. National Board Nwher for Unit: ~N A Component or anufacturer oranufacturer State or ational ppurtenance or Installer Serial Installer Province Board No. oi 0 ~

Feedwater Piping Bechtel /A /A /A 6"-FW-2401 6u-FW-2402 6U-FW-2403 14"-FW-2401 14"-FW-2402 14"-FW-2403 18"-FW-2401 18"-FW-2402 18u-FW-2403 Component Cooling Bechtel /A /A /A ater Piping Zone 120 Zone 121 Zone 123 Zone 125 Zone 126 Zone 127 Zone 129 Zone 131 Zone 132 Zone 133 Zone 134 Zone 136 Zone 137 Zone 140 Zone 141 Zone 151 Zone 154 Spent Fuel Pool Bechtel /A /A /A Cooling Water Intake Cooling Bechtel /A /A ater

1 ~ O~ner: Florida Power and Light Company, P.O. Box 029100, Miami, Florida 33102

2. Plant: Turkey Point Nuclear Power Plant, P.O. Box 3088, Florida City, Florida 33034
3. Plant Unit: 4 4~ Owner Certificate of Authorization (if required) ~N A
5. Comnercial Service Date : Se tember 7 1973
6. National Board Neer for Unit: ~N A Component or anufacturer oranufacturer State or ational ppurtenance or Installer Serial Installer Province Board No. 0~ 0~

uxiliary Bechtel /A /A /A Feedwater Piping Zone 160 Zone 161 Zone 163

II NIS-1 OWNERS DATA REPORT FOR INSERVICE INSPECTIONS Page 6 of 13

1. O~ner: Florida Power and Light Con@any, P.O. Box 029100, Hiami, Florida 33102
2. Plant: Turkey Point Nuclear Power Plant, P.O. Box 3088, Florida City, Florida 33034
3. Plant Unit: 4
4. Owner Certificate of Authorization (if required) ~N A
5. Comnercial Service Date : Se tember 7 1973
6. National Board Nwher for Unit: ~N A
8. Examination Dates: A ril 11 1993 to June 2 1993
9. Inspection Interval: from 4 14 84 to 4 13 94 Inspection Period: from 11 25 90 to 4 13 94
10. Abstract of Examinations and Statement Concerning Status of Work Required for Current Interval:

The Inservice Examination of selected Class 1, 2, and 3 components and piping systems of Florida Power and Light's Turkey Point Unit 4 was performed during the 1993 Refuel Outage. This outage began on April 11, 1993 and ended on June 2, 1993. This was the second outage of the third period of the second interval.

The components and piping systems examined were selected per the Second Ten Year Inspection Plan, which was prepared in accordance with the requirements of the 1980 Edition of ASME Section XI with addenda through Winter 1981.

Eddy Current examinations were conducted by FPL personnel from April, 1993 through May, 1993 on Steam Generators A, B, and C. A total of 9,610 tubes were examined. See the attached NIS-BB report for the summary of examination results.

The augmented Feedwater Nozzle piping examination program was conducted during this outage on all three Feedwater lines. The entire area from the nozzle ramp to a point one pipe diameter out on the far side of the elbow was examined with ultrasonics.

Cracking was detected on all three nozzle to reducer welds. The reducers were replaced.

An augmented examination was performed on the upper shell to transition piece weld of Steam Generator A. This was in response to industry concerns on cracking in this weld that has been found at other plants. No reportable indications were found.

Snubber functional testing and visual examinations were conducted in accordance with Turkey Pt. 4 Plant Technical Specifications.

Examination and testing services were supplied by Siemens Nuclear Power Services, Inc. during the period of April 21,1993 through May 18, 1993 Pressure

'ystem testing was conducted by plant personnel to applicable Plant Technical Specifications and Procedures.

NIS-1 OWNERS DATA REPORT FOR INSERVICE INSPECTIONS Page 7 of 13

'1. Ouner: Florida Power and Light ComPany, P.O. Box 029100, Niami, Florida 33102

2. Plant: Turkey Point Nuclear PoMer Plant, P.O. Box 3088, Florida City, Florida 33034
3. Plant Unit: 4
4. OMner Certificate of Authorization (if required) ~N A
5. Cawercial Service Date : Se tember 7 1973
6. National Board Number for Unit: ~N A System Hydrostatic Testing were performed by plant personnel during the period of April 13, 1993 through May 13, 1993 in accordance with Code requirements and Code Case N-498.

The number of examinations performed during this outage and the cumulative total of exams exceed the requirements of Program B of ASME Section XI.

11. Abstract of Conditions Noted
12. Abstract of Corrective Measures Recommended and Taken Non-destructive examinations were performed on selected welds in class 1, 2, and 3 systems. Volumetric examination methods included Eddy Current, Ultrasonic, and Radiography methods. Surface examinations were conducted with Penetrant and Magnetic Particle methods. Visual techniques were utilized on component supports and other areas where required.

Class 1 Steam Generator "C" The inlet and outlet manway bolting was examined. Several bolts showed minor corrosion, dents, and other mechanically induced flaws. These bolts were replaced.

Regenerative Heat Exchanger FPL conducted a visual (VT-3) examination on the Regenerative Heat Exchanger at the beginning of the outage, and a VT-2 during the RCS over pressure test. These examinations were conducted in accordance with Relief Request. No. 3. No evidence of leakage or boric acid accumulation from the Regenerative Heat Exchanger was noted.

Reactor Coolant Piping The elbow to nozzle welds on the RPV inlets were examined using surface techniques. Volumetric requirements were satisfied during the previous outage. No recordable indications were noted.

NIS-1 OWNERS DATA REPORT FOR INSERVICE INSPECTIONS Page 8 of 13

1. Owner: Florida Power and Light Company, P.O. Box 029100, Hiami, Florida 33102
2. Plant: Turkey Point Nuclear Power Plant, P.O. Box 3088, Florida City, Florida 33034
3. Plant Unit: 4 r
4. Owner Certificate of Authorization (if required) ~N A
5. Camercial Service Date : Se tember 7 1973
6. National Board Naker for Unit: ~N A The spring hanger on the pressurizer surge line was replaced and the associated integral attachment was permanently removed. A baseline examination was performed. There were no reportable indications.

Flange bolting and component supports on several lines were examined with Visual techniques. No reportable indications were noted. One weld was examined with radiography. There were no reportable indications.

Residual Heat Removal Piping Several welds were examined using ultrasonic and/or penetrant techniques. Normal weld geometry was recorded. No reportable indications were noted.

Component supports were examined with Visual techniques. No reportable conditions were noted.

Safety Injection Piping Several welds were examined using ultrasonic and/or penetrant techniques. Normal weld geometry was recorded. One penetrant indication was noted. An engineering evaluation determined be a surface anomaly, present since the plant went on line. It was it to removed and the area was re-examined. No other reportable indications were noted.

Component supports were examined with Visual techniques. One support tag was missing. The support tag will be replaced. No reportable indications were noted.

Chemical and Volume Control Piping Surface and volumetric examinations were conducted on selected welds. No reportable indications were noted.

Other Class 1 Information FPL has recently reviewed the plant Piping and Instrumentation Drawings in an effort to incorporate, to the extent practical, the current guidelines on Section XI Code boundaries. This has

0 NIS-1 OWNERS DATA REPORT FOR INSERVICE INSPECTIONS Page 9 of 13

1. Owner: Florida Power and Light Company, P.O. Box 029100, Miami, Florida 33102
2. Plant: Turkey Point Nuclear Power Plant, P.O. Box 3088, Florida City, Florida 33034
3. Plant Unit: 4
4. Owner Certificate of Authorization (if required) ~N A
5. Camercial Service Date : Se tember 7 1973
6. National Board Number for Unit: ~N A resulted in several areas being reclassified to either higher or lower Quality Groups. The Seal Leakoff from the Reactor Coolant Pumps was reclassified from Class 1 to Class 2. This resulted in the elimination of these lines from volumetric and surface examination requirements due to current Class 2 exemptions.

In accordance with IWB-2420(a), examinations performed during the first interval were repeated to the extent practical. The following examination areas were substituted:

Zone 040 Weld 2"-SI-1401-3 was substituted for weld 2"-SI-1401-2.

A non-removable support was interfering with cleaning of the examination area. Instead of having limitations, the weld next to this one was selected.

Zone 044 Weld 2"-SI-1406-3 was substituted for weld 2"-SI-1406-2.

A non-removable support was interfering with cleaning of the examination area. Instead of having limitations, the weld next to this one was selected.

Zone 047 Weld 3"-CH-1403-7 was substituted for weld 3"-CH-1403-2.

Weld 7 is located in an exclusion area (high radiation) and was not available for examination. A weld down the line was selected.

Class 2 Residual Heat Removal Pumps During the previous outage on Unit 3, a leak was found in one of the RHR Pump bodies. The flaw was removed and weld repaired.

Examinations were performed on the Unit 4 pumps to assure that leaks had not developed in the other unit. No reportable indications were noted.

Residual Heat Removal Volumetric and/or surface examinations were performed on selected welds. No reportable indications were noted. Visual examinations were conducted on selected component supports. Drawing discrepancies were noted. The supports were accepted as-is by engineering evaluation. The drawings will be updated to reflect field conditions. A loose lock nut was noted on one support. It was tightened under a Plant Work Order.

NIS-1 OWNERS DATA REPORT FOR INSERVICE INSPECTIONS Page 10 of 13

1. Owner: Florida Power and LiBht Company, P.O. Box 029100, Niami, Florida 33102
2. Plant: Turkey Point Nuclear Power Plant, P.O. Box 3088, Florida City, Florida 33034
3. Plant Unit: 4
4. Owner Certificate of Authorization (if required) ~N A
5. Camercial Service Date : Se tember 7 1973
6. National Board Number for Unit: ~N A Safety Injection Surface examinations were performed on selected welds. No reportable indications were noted.

Containment Spray Surface examinations were performed on selected welds. No reportable indications were noted.

Main Steam Surface examinations were performed on selected welds. No reportable indications were noted.

Steam Generator Blowdown Volumetric and/or surface examinations were performed on selected welds. Acceptable indications were noted. Visual examinations were conducted on selected component supports. No reportable indications were noted.

Feedwater Bypass Visual examinations were performed on selected component supports.

Chipped concrete was found on one support. It was accepted as-is by engineering evaluation. It will be corrected under a Plant Work Order. No other reportable indications were noted.

Excess Letdown Heat Exchanger Volumetric examinations were performed on a circumferential weld.

A long seam was discovered during this examination. Both welds were examined with no reportable indications.

Residual Heat Removal Heat Exchangers Surface or volumetric examinations were performed on selected welds. No reportable indications were noted.

NIS-1 OWNERS DATA REPORT FOR INSERVICE INSPECTIONS Page 11 of 13 e 2.

3.

4.

Owner:

Plant:

Plant Unit: 4 Florida Power and Light Company, P.O. Box 029100, Niami, Florida 33102 Turkey Point Nuclear Power Plant, P.O. Box 3088, Florida City, Florida Owner Certificate of Authorization (if required) ~N A 33034

5. Comercial Service Date : Se tember 7 1973
6. National Board Neer for Unit: ~N A Class 3 Component Cooling Water Visual examinations were performed on selected supports and integral attachments. Indications found included paint, on spherical bearings, drawings discrepancies, improper spring can settings, and one partially dislodged spherical bearing. These were all accepted by engineering evaluation as performing their intended function. The spherical bearings will be cleaned under a Plant Work Order.

Auxiliary Feedwater Visual examinations of selected component. supports and integral attachments were conducted. Damaged insulation was noted on an adjacent line next to one support. This was accepted as-is by engineering evaluation. insulation will be modified to provide 0 more clearance for the support.

Au ented Examinations The Reactor Coolant Flywheel Examinations The 4A Reactor Coolant Pump Motor was replaced during this outage.

The removed pump motor accordance with Turkey Point procedures.

will have routine maintenance on The pump motor placed in it in service is serial no. 1S-76P499. The flywheel of this motor was examined by Surface and Volumetric techniques by Westinghouse in their Pittsburgh facilities in accordance with Reg. Guide 1.14. No indications were noted.

The flywheel on Reactor Coolant Pump 4B was volumetrically examined. No indications were reported.

Main Feedwater System Piping An augmented Feedwater Nozzle examination program was conducted during this outage on all three Steam Generators. An ultrasonic examination was performed from the nozzle taper to one pipe diameter beyond the elbow to pipe weld. The examinations detected cracking in the reducer side of the reducer to feedwater nozzles on

NIS-1 OWNERS DATA REPORT FOR INSERVICE INSPECTIONS Page 12 of 13 e 1.

2.

Owner:

Plant:

3. Plant Unit: 4 Florida Power and Light Company, P.O. Box 029100, Niami, Florida 33102 Turkey Point Nuclear Po~er Plant, P.O. Box 3088, Florida City, Florida
4. Owner Certificate of Authorization (if required)

Ccenercial Service Date : Se tember 7

~N A 33034

5. 1973
6. National Board Number for Unit: ~N A all three lines. The reducers were replaced and baseline examinations were performed on the new welds.

Steam Generators The secondary side of all three Steam Generators were visually examined. No reportable indications were noted.

The "CL" weld on Steam Generator A (transition cone to upper shell) was examined. This examination was performed as part of an ongoing program by FPL to monitor this weld in the Turkey Point Steam Generators. This is due to concern with cracking that has been detected in this weld at other plants. No reportable indications were found.

Report Organization Description of Services Number N/A FPL Summary Report of Hydrostatic Testing Program Turkey Point Unit No. 4 Refuel Outage N/A FPL Summary Report Visual Examination and Functional Testing of Snubbers

NIS-1 OWNERS DATA REPORT FOR INSERVICE INSPECTIONS Page 13 of 13 1 ~ Owner: Florida Power and Light Company, P.O. Box 029100, Niami, Florida 33102

2. Plant: Turkey Point Nuclear Power Plant, P.O. Box 3088, Florida City, Florida 33034 3~ Plant Unit: 4 4~ Owner Certificate of Authorization (if required) ~NA
5. Cemercial Service Date: Se tember 7 1973
6. National Board Number for Unit: ~N We certify that the statements made in this report are correct and the examinations and corrective measures taken conform to the rules of the ASME Code,Section XI.

Fl r3.d Power and Lz.ght Company 0

By: s" Certif'te of uthorization No. (if Applicable): N/A Expirat n Date: N/A Certificate of Inservice Inspection I, the undersigned, holding a valid National Board of Boiler and Pressure Vessel Inspectors and/

commission issued by the or the State or Province of Dade County and employed by Arkwright Mutual Insurance Company of Norwood, Massachusetts have inspected the components described in this Owners'ata state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in the Owners'ata Report in accordance with the requirements of the ASME Code,Section XI. By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations, and neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or conn cted with th's 'nspection.

's Signature SXo National Board, State, C~

nspecto Province, and No.

Dat

I TURKEY POINT UNIT 4 1993 REFUELING OUTAGE Form NIS-BB Owners'ata Report for Eddy Current Examinate.ons

Page1 of 1 FORM NIS.BB OWNERS'ATA REPORT FOR EDDY CURRENT EXAMINATIONRESULTS As required by the provisions of the ASME CODE RULES EDDY CURRENT EXAMINATIONRESULTS PLANT: Turkey Point Unit 4 EXAMINATIONDATES: APRIL 24, 1993 thru APRIL 28, 1993 TOTAL TUBES TUBES TOTAL TOTAL TUBES PLUGGED AS PLUGGED PLUGGED STEAM TUBES PREVENTIVE THIS TUBES GENERATOR INSPECTED 406 10096 MAINTENANCE OUTAGE IN S/G 4E210A 3198 NONE NONE NONE 16 4E210B 3206 NONE NONE NONE 4E21 OC 3205 19 NONE NONE NONE LOCATION OF INDICATIONS (20% - 100%)

SUPPORT LOCATIONS TOP OF TUBE SHEET TOTAL STEAM AV8 1 THROUGH 6 TO ¹1 SUPPORT INDICATIONS GENERATOR BARS COLD LEG HOT LEG COLD LEG HOT LEG 2Pog. 3goj, 4P% TO1PPo~o 4E21 OA NONE NONE NONE NONE 4E21 OB NONE 4E210C 12 NONE NONE 23 NONE Remarks:

CERTIFICATION OF RECORD We certify that the statements in this report are correct and the tubes inspected were tested in accordance with the requirements of Section XI of the ASME Code.

Florida Power & Light Co.

DATE'ATE PREPARED By Cc . ~ ~<+~~

EDDY A ~So URRENT

> ~

DINAT R

/

REVIEWED BY'N SU RVISOR DATE C /1 /3 APPROVED BY:

S/ PR RAM M ER an FPL Group company

CINULATIVE EXAHIHAT ION REPORT PTN-4 OUTAGE  : 04/93 e COMPONENT  : S/G A OESCRIPTIOH : 20X TO 100K Page: 1 of Date : 6/ 4/93 Time : 9:35 AH 1

I I Extent I 04/93 I I N/A I IRovIColILegIReqITst/NoteI Reel Probe Location IVoltsIDegICh IDiffI Location

'-I- I I I I--------I I

I. .- . .I -- I I I X I I I IvoltsIOegICh I I I I X I I---'

I 28I 14I C ITEHITEH IAC006-02IA-720-H/ULC I01H 42.6 I 1.61145I 11 32I I I I I I I I I C ITEHITEH IAC006.02IA-720.H/ULc I02c 2.7 I .8I146I 11 31I I I I I I I I 14I 82I H ITECITEC PSIAH004.02IA-720-H/ULC I04c 9.5 I .8I157I 1I 27I I I I

'-I---I---I---I ----I----.---I-----------I-------------I-----I---I---I- I I I I Number of RECORDS Selected from Current Outage : 3 Number of TUBES Selected from Current Outage : 2

h CUHULATIVE EXAMIHAT ION REPORT PTN 4 OUTAGE : 04/93

OMPONEHT  : S/G 8 Page  : 1 of 1 DESCRIPTION : 20K TO 100K Date : 6/ 4/93 Tine : 9:35 AM

+

I ( Extent I 04/93 I H/A I (Roe(col(Leg(Req(Tst/Note( Reel Probe Location (Volts(Deg(Ch X (Diff( Location (Volts(Deg(Ch I X

' I I I

. I

-- -I

(

I I- I I I I I -I - ---- I- - -I-- --I I --'0(

(

I BI 181 C ITEHITEH IBC016-04(A.700.M/ULC ITSC 3.9 .7(148( ( I I I I I 3( 24( C (06C(06C IBC011-03(A-720.M/ULC I03C 25 ' I 9(150( 1( 28( I I I I I 22( 37( H ITECITEC SSIBH026-07(A-720.M/ULC I02K .0 I 4 I 143 I 1 I 32( I I I I I I 45( 42( H ITECITEC IBH013-03(A-720.M/ULC IAV2 .0 I 5I I>>l 22( I I I I I I 45I 43I H ITECITEC IBH013-03IA-720-M/ULc IAV2 .0 I .6I I>> I 23( I I I I I I I 22I 48I H ITECITEC PCIBH023.06IA-720.M/ULC ITSH 6.3 32I I I I I I I I 45( 48( H ITECITEC PSIBH011-03(A-720-M/ULC IAV4 .0 I ~ 7I I>>I 24( I I I I I I I 37I 69I H ITECITEC SSIBH030-03IA-720.M/ULC ITSH 21.6 .7(145( 1( >>I I I I I I I I 14I 82I H ITECITEC SSIBH004-02IA-720-M/ULC I02H 15.6 I 1 ~ 2 I 150 I 1 I 26( I I I I I

'--- I--- I--- I--- I-------- I- I I I I I- I I -I --------- - I-----I --I-

-I---'umber of RECORDS Selected from Current Outage : 9 Number of TUBES Selected from Current Outage : 9

CUHULATIVE EXAMINATION REPORT PTN-4 OUTAGE  : 04/93 COMPONENT : S/G C Page : 1 of 1 DESCRIPTION : 20X TO 100X I<<

Date : 6/ 4/93 Time : 9:35 AM

+

I I Extent I 04/93 I N/A I (Row(Cot(Leg(Req(Tst/Note( Reel (

Probe Location (Volts(oeg(Ch (

x (Diff( Location (Volts(Deg(ch X

'--l---l-- I---I- - ---I- I I- I I

-I---I".I-.--I-------------I---- I- I I I I

( 2e( 2e( c (TEH(TEH (cc016-04(A-720-M/ULC 105H 44.0 ( .9(1S3( 26( I I I I I I I I c ITEHITEH PSICC016-04IA-720.H/ULC 106H -.9 1.0(149( 1( 301 I I I I I I 371 321 c ITEHITEH (ccoie-o4(A-72o-M/ULc Io6c ..7 .71119IP 11 37( I I I I I I 26( 37( C ITEN(TEH ICC014-03(A-720.H/ULC lose 31.5 .8(157( 1( 2O( I I I I 3( s2( c Io6c(o6c PSICC013-03IA-720.H/ULC 101C 29.6 611521 11 251 I I I I I I 431 521 H ITEGITEc SSICH022-05(A-720-H/ULC 105H 12 ' .611501 11 24( I I I I 401 531 C ITEHITEH Sc(CC021-05(A-720-M/ULC Io6c -.5 .61127IP 11 3O( I I I I 241 561 H ITEGITEc PSICH023 06(A-720.SF/RH 103C 38.7 .6(135 ( 1( aS/ I I I I 421 561 H ITEGITEc SSICH022.05IA-720-H/ULC Io6c ..6 .1.2(120(P 1( I I I I I I H ITEGITEc ITEGITEc SSICH022.05IA-720.M/ULC 105C SSICH022.05IA-720.H/ULC lose 32.3 13.2

.511411

.611431 11 311 30(

I I, I I I I H 11 I I I I 331 611 c ITEHITEH SSICC021-05IA-720.H/ULC 103C 26.1 .3(144( 1( I I I I 241 621 H ITECITEC PSICH024.06IA-720.M/ULC Io2c 35.3 ~ 611621 11 21( I I I I I

I 37( 691 321 701 C

H (TEHITEH ITEGITEc PCICC022-06IA-720.M/ULC 106H PSICH008.03IA-720.M/ULC IAV1

.1

.0

.511501

.s(

11 2s(

II 2( 22(

I I

I I

I,I I I I 16( 721 H ITECITEC ICH002.01IA-720.H/ULC IDSH 43.0 30( I I I I I 721 H ITEGITEc SCICH006-02IA-720.M/ULC (o4c 21.1 3(1521 1( 26( I I I I 371 721 H ITECITEC PSICH008.03IA-720.M/ULC (05H 45.0 .5(139( I I I I I I H ITEGITEc ICH008.03IA-720.M/ULC (AV3 . 2 .s(148(I 2( 23( I I I I 231 771 H ITEGITEc PSICH007.02IA.720.M/ULC Io2c 50.6 .411481 11 28( I I I I 311 801 H ITEGITEc SSICH022.05IA-720-M/ULC (06H 2.3 .4(142( I I I I 271 811 H ITEGITEc SCICH007-02IA-720.H/ULC IAV1 .0 .31 I>>l 2O( I I I I 261 821 H ITECITEC SCICH007-02IA-720.H/ULC IAV1 .0 .31 I>>I 201 I I I I I I

'--l---l -I---I -- ---I- I I

--I I I I

-I---I---+

Number of RECORDS Selected from Current Outage 23 Number of TUBES Selected from Current Outage : 19

CUMMULATIVE DISTRIBUTION

SUMMARY

TURKEY POINT UNIT g 4 04/93 COMPONENT  : S/G A Page: 1 of 1 Date: 06/14/93 Time: 1:30 PM Examination Dates  : 04/24/93 thru 04/28/93 Total Number of Tubes Inspected .....: 3198 Total Indications Between 20% and 39~

Greater than or equal to 40.

Total Tubes Plugged as Preventive Maint 0 Total Tubes Plugged 16 Location Of Indications 20 'o 100%

Hot Leg Cold Leg TSH -.5 to 01H -2.1 0 TSC -.5 to 01C -2.1 01H -2.0 to 06H +2.0 1 01C -2.0 to 06C +2.0 06H +2.1 to AVl -3.1 0 06C +2.1 to AV4 -3.1 AV1 -3.0 to AV4 -3.0

CUMMULATIVE DISTRIBUTION

SUMMARY

TURKEY POINT UNIT 5 4 04/93 COMPONENT  : S/G B Page: 1 of 1 Date: 06/14/93 Time  : 1:30 PM Examination Dates  : 04/24/93 thru 04/28/93 Total Number of Tubes Inspected 3206 Total Indications Between 20. and 39%

Greater than or equal to 40%

Total Tubes Plugged as Preventive Maint Total Tubes Plugged Location Of Indications 20% to 100%

Hot Leg Cold Leg TSH -.5 to 01H -2.1 2 TSC -.5 to 01C -2.1 01H -2.0 to 06H +2.0 2 01C -2.0 to 06C +2.0 06H +2.1 to AV1 -3.1 0 06C +2.1 to AV4 -3.1 AV1 -3.0 to AV4 -3.0

0 CUMMULATIVE DISTRIBUTION

SUMMARY

TURKEY POINT UNIT g 4 04/93 COMPONENT  : S/G C Page  : 1 of 1 Date  : 06/14/93 Time  : 1:30 PM Examination Dates  : 04/24/93 thru 04/28/93 Total Number of Tubes Inspected .....: 3205 Total Indications Between 20. and 39% 23 Greater than or equal to 40% 0 Total Tubes Plugged as Preventive Maint Total Tubes Plugged Location Of Indications 20% to 100%

Hot Leg Cold Leg TSH -.5 to 01H -2.1 0 TSC -.5 to 01C -2.1 : 0 01H -2.0 to 06H +2.0 6 01C -2.0 to 06C +2.0 : 12 06H +2.1 to AVl -3.1 4 06C +2.1 to AV4 -3 '  : 0 AV1 -3.0 to AV4 -3.0

TURKEY POINT UNIT 4 1993 REFUELING OUTAGE Form NIS-2 Owners'ata Report of Repairs and Replacements

Page 1 of 3 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI F ORIDA POWER 8 LIGHT Date JANUARY 9, 1992 Owner P.O. BOX 029100 MIAMI FL 33152 Sheet of Addross Plant TURK POINT Unit 4 Name CWO: 200099, PC/M:88-541, PS: 90-1544 P.O. BOX 3088 FLORIDA CITY FL 33034 N91-0581 N91-0734 N91-0196 Address Repair Orrtanization p.o. No., Jab No., etc.

3. Work Performed by Type Code Symbol Stamp Name Authorization No.

Expiration Date N/A Address

4. Identification of System MAIN STEAM Quality Group B
5. (a) Applicable Construction Code B3 19 55 Edition, N Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980, Edition, Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components Manufacturer National Other Repaired, Name of Name of Board Year Replaced Stamped Component Manufacturer Serial No. No. Identification Built or Replacement (Yes or No)

Est.

GLOBE VALVE N/A CV-4-1606 REPLACED NO 1970 ANCHOR/DARLING GLOBE VALVE D 8089M-4 N/A CV-4-1606 1990 REPLACEMENT YES VALVECO.

Est.

GLOBE VALVE N/A N/A N/A CV-4-1607 REPLACED NO 1970 ANCHOR/DARLING GLOBE VALVE DB0894-5 N/A CV-4-1 607 1990 REPLACEMENT YES VALVECO.

Est.

GLOBE VALVE N/A N/A CV-4-1608 REPLACED NO 1970 ANCHOR/DARLING GLOBE VALVE D 8089M-6 N/A CV-4-1 608 1990 REPLACEMENT YES VALVECO.

Est.

GATE VALVE N/A N/A N/A 4-10-001 REPLACED NO 1970 REPLACED ATMOSPHERIC DUMP VALVES CV-4-1606, CV-4-1607, CV-4-1608, AND THE ASSOCIATED UPSTREAM STOP VALVES 4-1 0-001, 4-1 0402 AND 4-1 0403.

8. Tests Conducted:

Hydrostatic ~X Pneumatic ~ Nominal Operating Pressure ~ Other ~X SYSTEM IN SERVICE Pressure 1 650 / 852 psi Test Temp. Degree's F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2 in.

X 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

92-002-4

Page 2 of 3 FORM HIS-2 (Back)

9. Remarks Examinations performed by FPL Construction Quality Control personnel.

Applicable Manufacturer's Data Reports to be attached ALLWELDING WAS PERFORMED IN ACCORDANCE WITH THE FPL WELD CONTROL MANUALAND SITE PROCEDURES.

INVOKED ASME CODE CASE N-416 FOR THE HYDROTEST FOLLOWING THE INSTALLATION.

CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code,Section XI. repair or replacement N/A Type Code Symbol Stamp N/A Expiration Date N/A Certificate of Authorization No.

Date / ~~

Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade Count Florida and employed by Arkwri ht Mutual Insurance Com an of Norwood MA have inspected the componen s described in this Owner's Report during the period to , and state that to the best of my nowled and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Futhermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Factory Mutual System Commissions inspector's Signature 19+ ~ National Board, State, Province, and Endorsements

Page3of3 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI JANUARY 9, 1992

1. Owner FLORIDA POWER & LIGHT Date Sheet of Address
2. Plant Unit Name CWO: 200099, PC/M: 88-541, PS: 90-1544 P.O. BOX3088 FLORIDA CITY FL33034 N91-0581 N91-0734 N91-0196 Add ross Repair Organization P.O. No. Job No., etc.

~

3. Work Performed by Type Code Symbol Stamp Name N/A Authorization No.

Expiration Date N/A Address MAIN STEAM

4. Identification of System 19 55 Edition, N Addenda, Code Case
5. (a) Applicable Construction Code (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980, Edition, Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components ASME National Repaired, Code Name of Name of Manufacturer Other Year Board Identification Built Replaced, Stamped Component Manufacturer Serial No. (Yes or No. or Replacement ANCHOR/DARLING GATE VALVE EB089-1-4 N/A 4-10-001 1990 REPLACEMENT YES VALVECO.

Est.

GATE VALVE N/A N/A 4-10-002 REPLACED 1970 ANCHOR/DARLING GATE VALVE EB089-1-5 N/A 4-10-002 1990 REPLACEMENT YES VALVECO.

Est.

GATE VALVE N/A N/A N/A 4-10-003 REPLACED 1970 ANCHOR/DARLING GATE VALVE EB089-1-6 N/A 4-10-003 1990 REPLACEMENT YES VALVECO.

92-002-4

Page 1 of 2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI FLORIDA POWER 8 LIGHT Date JANUARY 14, 1992 Owner Name P.O BOX 029100 MIAMI FL 3315 Sheet of Addross TURK Y POINT Unit 4 plant Name CWO: 300137 PC/M: 88-249 P.O. BOX 3088 FLORIDA CITY FL33034 MP IL: 90-205M Address Repair Organization P.O. No., Jab No. otc.

~

3. Work Performed by Type Code Symbol Stamp Name Authorization No.

Expiration Date N/A Addross

4. Identification of System Quality Group B B31. 5 Edition, NA Addenda, N/A Code Case
5. (a) Applicable Construction Code 19 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980, Edition, Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components ASME National Other Repaired, Name of Name of Manufacturer Board Year Replaced, Stamped Component Manufacturer Serial No. No. Identification Built or Replacement (Yes or No)

Est.

BUTTERFLY VALVE N/A N/A N/A 4-887 REPLACED NO 1970 ANCHOR/DARLING 4-887 1990 REPLACEME NO GLOBE VALVE EA993-1-1 N/A VALVECO.

Est.

RHR PIPING N/A N/A N/A 4-SIH-15 REPLACEME NO 1970 RHR PIPING N/A N/A N/A 97L0 REPLACEMEN NO 1

RHR PIPING N/A N/A N/A SR-633 REPLACEMEN NO 4-SIH-25

'st. REPLACEMEN NO RHR PIPING N/A N/A 1970 Est.

RHR PIPING N/A N/A N/A 4-SIH-19 REPLACEME NO 1970 REPLACED VALVEAT TAG LOCATION 4-887 DUE TO EXCESSIVE SEAT LEAKAGE, AND ASSOCIATED PIPING. ALSO MODIFIED SUPPORTS 4-SIH-1 5, 4-SIH-19, 4-SIH-25, SR-633 AND SUPPORT A TO MEET DESIGN.

8. Tests Conducted: Hydrostatic X Pneumatic Nominal Operating Pressure Other 250/750 AMBIENT Pressure psl Test Temp. Degree's F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in.

X 11 in., (2) information initems 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

92-006-4

Page 2 of 2 FORM NlS-2 (Back)

9. Remarks Examinations performed by FPL Construction Quality Control personnel.

Applicable Manufacturer's Data Reports to be attachod ALLWELDING WAS PERFORMED IN ACCORDANCE WITH THE FPL WELD CONTROL MANUALAND SITE PROCEDURES.

CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code,Section XI. repair or replacement N/A Type Code Symbol Stamp N/A Expiration Date N/A Certificate of Authorization No.

Signed , 19~ 2-Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade Count Florida and employed by Arkwri ht Mutual Insurance Com an of Norwood MA have inspected the components described in this Owner's Report during the period to , and state that to the best of my knowledg and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes anywarranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Futhermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Factory Mutual System Commissions 8230 lns

~

tor's Signature ie+

National Board, State, Province, and Endorsements

Page 1 of 3 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI FLORIDA POWER & LIGHT Date JANUARY 14, 1992 Owner Name P.O. BOX 029100 MIAMI FL 33152 Sheet of Address 2 Plant TURKEY POINT Unit 4 Name CWO: 200093, PC/M: 90-221 P.O. BOX 3088 FLORIDA CITY FL33034 PS: 90-1590 MPIL: 90-255M Address Repair Ortianization p.o. No., Job No., etc.

3. Work Performed by Type Code Symbol Stamp Name Authorization No.

Expiration Date N/A Address

4. Identification of System Quality Group A
5. (a) Applicable Construction Code 19 55 Edition, N Addenda, N Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980, Edition, Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components ASME Name of Manufacturer National Other Repaired, Code Name of Board Year Replaced, Stamped Component Manufacturer Serial No. No. identification Built or Replacement (Yes or No)

RCS PIPING Est.

N/A N/A N/A N/A REMOVED NO LOOP 'A" 1970 RCS PIPING Est.

N/A N/A N/A REMOVED LOOP 1970 B'CS PIPING Est.

N/A N/A N/A N/A REMOVED LOOP C" 1970 MECHANICALSHOCK PACIFIC 33630 N/A 4-1023 N/A REMOVED YES ARRESTOR SCIENTIFIC MECHANICALSHOCK PACIFIC 29446 N/A 4-1 024 REMOVED YES ARRESTOR SCIENTIFIC MECHANICALSHOCK PACIFIC 11988 N/A 4-1025 REMOVED YES ARRESTOR SCIENTIFIC MECHANICALSHOCK PACIFIC 33629 N/A 4-1026 N/A REMOVED YES ARRESTOR SCIENTIFIC REMOVED EXISTING RESISTANCE TEMPERATURE DETECTOR (RTD) BYPASS MANIFOLD PIPING, VALVES, SUPPORTS AND MECHANICALSHOCK ARRESTORS.

8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other N/A Pressure psi Test Temp. Degree's F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in.

X 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

92-007-4

Page 2 of 3 FORM HIS-2 (Back)

9. Remarks Examinations performed by FPL Construction Quality Control personnel.

Applicable Manufacturer's Data Reports to be attached CERTIFICATION OF COMPLIANCE REMOVAL conforms We certify that the statements made in the report are correct and this to the rules of the ASME Code,Section XI. repair or replacement N/A Type Code Symbol Stamp N/A Expiration Date N/A Certificate of Authorization No.

Signed Date Owner or Owner's Designee, Title

/t'ERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade Coun Florida and employed by Arkwri ht Mutual Insurance Com an of Norwood MA have inspected the components described in this Owner's Report during the period 00 to , and state that to the best of my knowledge and belief, the Owner as performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes anywarranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Futhermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Factory Mutual System t 'gnature 197 ~ ommissions National Board, State, Province, and Endorsements

Page3of3 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI F ORIDA POWER & LIGHT JANUARY 14, 1992 Owner Date Sheet of Address

2. Plant Unit CWO: 200093, PC/M: 90-221 P.O. BOX 3088 FLORIDA CITY FL 33034 PS: 90-1590 MPIL: 90-255M Address Repair Organization P.O. No., Job No., otc.
3. Work Performed by Type Code Symbol Stamp Name Authorization No. N/A Expiration Date N/A Add ross REACTOR COOLANT
4. Identification of System
5. (a) Applicable Construction Code B31.1 19 55 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980, Edition, Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components ASME National RePaired, Code Name of Name of Manufacturer Other Year Board Replaced, Stamped Component Manufacturer Serial No. Identification Built No. or Replacement (Yes or MECHANICALSHOCK PACIFIC 16726 N/A 4-1027 N/A REMOVED YES ARRESTOR SCIENTIFIC MECHANICALSHOCK PACIFIC 35899 N/A 4-1028 N/A REMOVED YES ARRESTOR SCIENTIFIC MECHANICALSHOCK PACIFIC 29447 N/A 4-1029 N/A REMOVED YES ARRESTOR SCIENTIFIC MECHANICALSHOCK PACIFIC 29582 N/A 4-1030 N/A REMOVED YES ARRESTOR SCIENTIFIC MECHANICALSHOCK PACIFIC 11990 4-1031 N/A REMOVED YES ARRESTOR SCIENTIFIC
7. Description of Work 92-007-4

0 Page 1 of 2 FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI FLORIDA POWER & LIGHT Date January 14. 1994~~

P.O. BOX 029100 ~ MIAMI, FL 33102 Sheet 1 of Address TURKEY POINT

2. Plant Unit Name P.O. BOX 3000, FLORIDA CITY. FL 33034 PWO: 0715 PCMtt 07-225 Address Repag organization P.O. No.. Job No. etc.

Work Performed by FLORIDA POWER & LIGHT Type Code Symbol Stamp N/A Name Authorization No. N/A P.O. BOX 3000, FLORIDA CITY. FL 33034 N/A Expiration Date Address

4. Identification of System Feedwater Quality Group
5. (a) Applicable Construction Code ANSI B31 1 19 55 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980, Edition, Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components ASME Name of National Repaired, Code Name of Manufacturer Other Year Stamped Component Manufacturer Board Identification Replaced, Serial No. Built (Yes or No. or Replacement No)

EST.

Gate Valve N/A N/A N/A 4-20-706 1970 Replaced No Gate Valve Henry Vogt 6-215547 N/A 4-20-706 1907 Replacement No 7 Description of 'Worlt Replaced valve at tag location 4-20-706 due to excessive seat leakage.

~

8. Tests Conducted: Hydrostatic X Pneumotic Nominal Operating Pressure Other Pressure psi Test Temp I igegree's p NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in.

X 11in. ~ (2) information in items 1 through 6 on this report is included on each sheet. and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. 92-000-4

Page 2 of 2 FORM NIS 2 (Back)

9. Remarks All welding was performed inaccordance with the FPL Weld Control hfanual and site Applicable Manufacturer's Data Reports to be attached procedures.

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this > conforms repair or replacement to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Author'ion N/A N/A Certificate of No. Expiration Date Signed Date ~ 19 Q~

Owner or Owner's assignee. Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade County, Florida and employed by Arlcwri ht, hfutual Insurance Com an of Norwood. hfA.

September 17, 1906 hove inspected the components described in this Owner's Report during the period to October 6. 1991 , and state that to the best of my knowledge and belief, the Owner has performed examinotions and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damoge or a loss of any kind arising from or connected with the inspection.

Factory hfutual System Commissions 0230 N I Inspector's Signature National Board. State. Province. and Endorsements lggg~W

Page 1 of 2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI FLORIDA POWER 8c LIGHT hiarch 2, 1992 Name P.O. BOX 029100, hiIAMI, FL 33102 Sheet 1 of Address TURKEY POINT

2. Plant Unit Name P.O. BOX 3088, FLORIDA CITY, FL 33034 PWO: 1217 WA¹910712140425 Address Repar Organization P.O. No., Job No. etc.

Work Pe formed by FLORIDA POWER 8c LIGHT Type Code Symbol Stamp N/A Name Authorization No. N/A P.O. BOX 3008. FLORIDA CITY. FL 33034 N/A Expiration Date Address

4. Identification of System Intake Cooling Water Quality Group C
5. (a) Applicable Construction Code ANSI B31 1 19 55 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980, Edition, Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components ASME National Repaired, Code Name of Name of Manufacturer Other Stamped Board Replaced, Component Manufacturer Serial No. 'o. Identification B ilt or Replacement (Ycs or No)

EST.

Gate Valve N/A N/A N/A 4-50-377 1970 Replaced No Gate Valve Jenkins N/A N/A 4-50-377 1991 Replacement No pescription of 'Work Replaced valve at tag location 4-50-377 due to excessive 7

seat leakage.

8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure X Other Test Temp gg Degree's Pressure ps l F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used. provided (1) size is 8 1/2 in.

X 11in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is

~

numbered and the number of sheets is recorded at the top of this form. 92-009-4

Page 2 of 2 FORM NIS-2 (Back) hfechanical connection. No welding performed.

Applicable Monufactwer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report ore correct and this p a conforms repae or replocernent to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A N/A Certificate of Authorization No. Expiration Date Signed Dote , t95~

Owner or Owner's Designee. Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade County. Florida and employed by Arkwri ht hiutual Insurance Com an of Norwood. hiA.

have inspected the components described In this Owner s Report during the period u'y to Februar 27. 1992 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied. concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with the inspection.

Factory hfutual System Commissions .0230 N I actor's Signature Hotional Board. State. Province. and Kndorsements

Page of 2 FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS 1

As Required by the Provisions of the ASME Code Section Xl

1. Owner FLORIDA POWER & LIGHT Dote March 23. 1992 Name P.O. BOX 029100. MIAMI, FL 33102 Sheet of Address TURKEY POINT 4
2. Plant Unit Name P.O. BOX 3088. FLORIDA CITY, FL 33034 PWO: 2256 WAss 901009141716 Address Repa'r organisation P,O. No.. Job No. etc.

Work Performed by FLORIDA PO ER & LIGHT N/A Type Code Symbol Stamp Name Authorization No. N/A P.O. BOX 3088. FLORIDA CITY, FL 33034 N/A Expiration Date Address

4. identification of System Spent Fuel Pool Cooling Quality Group
5. (a) Applicable Construction Code ANSI B31 I 19 55 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1980, Edition, Winter 1981 Addenda
6. identification of Components Repaired or Replaced and Replacement Components ASME Name of Name of Manufacturer Notional Repaired, Code Other Year Component Manufacturer Serial No. Board Replaced Stamped Identification Built (Yes or No. or Replacement No)

Butterfly Valve Continental N/A N/A 4-820 N/A Replaced No Butterfly Valve Posi-Seal 56943-1B N/A 4-820 1991 Replacement No 7 Description of 'Work Replaced valve at tag location 4-820 due to excessive seat leakage.

8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other Pressure psl Test Temp gg Degree's F NOTE: Supplemental sheets in form of lists, sketches. or drawings may be used, provided (1) size is 8 1/2 in.

X 1 lin., (2) information in items 1 through 6 on this report is included on each sheet. and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. 92-010-4

Page 2 of 2 FOR M NIS-2 (Ba ck)

9. Remarks Mechanical connection, No welding performed.

Applicable Monuiacturer's Ooto Reports to be attached CERTIFICATE OF COMPLIANCE

" p conforms We certify that the statements made in the report ore correct and this repair or replacement to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A N/A N/A Certificate of Authori tion No. Expiration Dote Signe owner or Owner's Desiqnee. Title Dote ~/o C, 19 P~

CERTIFICATE OF INSEAVICE INSPECTION I. the undersigned. holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade County, Florida and employed by Aricwri ht Mutual Insurance Com an of Norwood. MA.

have inspected the components described in this Owner's Report during the period to December 10. 1991 ~ and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code.Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore.

neither the inspector nor his employer shall be liable in any manner for any personal injury or property darriage or a loss of any kind arising from or connected with the inspection.

Factory Mutual System Commissions 0230 N I) pec'taf s Signature National Board. Stote. Province. and Endorsernents 19M%

Page 1 of 2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI FLORIDA POWER & LIGHT Date hiarch 23. 1992 Name P.O. BOX 029100. MIAMI. FL 33102 sheet t of Address TURKEY POINT 4 Unit Name P.O. BOX 3000, FLORIDA CITY, FL 33034 PWO: 9057 WAss 911220142110 Address Repar Organization P.O. Na.. Jab Na. etc.

3 Work Performed by FLORIDA POWER & LIGHT N/A Type Code Symbol Stamp Name Authorization No. N/A P.O. BOX 3000, FLORIDA CITY, FL 33034 N/A Expiration Date Address

4. Identification of System Chemical and Volume Control Quality Group
5. (a) Applicable Construction Code ANSI B31 1 19 55 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980, Edition, Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components ASME Name of Name of Manufacturer National Repaired, Code Other Year Stamped Component Manufacturer Serial No. Board Replaced.

Identification Built (Yes or No. or Replacement No)

Cylinder Block Union Pump N/A N/A 4P201A N/A Replaced Cylinder Block Union Pump hiC35000 N/A 4P201A 1991 Replacement No 7 Descri tjon of W k Replaced Cylinder Block on Charging Pump 4P201A

8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other Pressure >>gg psi Test Temp tgfr Degree's F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in.

X 11in., (2) informotion in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. 92-011-4

FORM NIS 2 (Back)

9. Remarks hfechanical connection, No welding performed.

Applicable Manu(acturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify thot the statements made in the report are correct and this ep conforms repair or reptacement to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorizat' No. N/A N/A Expiration Date Date 19 9'2 Signed Owner or owner's esignee. Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned. holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade County, Florida and employed by Arlcwri ht hfutual Insurance Com an of Norwood. hfA.

hove inspected the components described in this Owner's Report during the period to December 26. 1991 , and state that to the best of my knowledge and belief ~

the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code.Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or o loss of any kind arising from or connected with the inspection.

Factory hfutual System Commissions 0230 N I spector's Siqnature National Board. State. Province. and Endarsements

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI FLORIDA POWER 8t LIGHT Date March 24, 1992 Name P.O. BOX 029100. ItfIAMI. FL 33102 Sheet 1 of Address TURKEY POINT Unit Name P.O. BOX 3088, FLORIDA CITY, FL 33034 PWO: 1014 WAst 900724103752 Address Repai'rganizotion P.O. No.. Job No. etc.

Work Performed by FLORIDA POWER Sc LIGHT N/A Type Code Symbol Stamp Name Author ization N o. N/A P.O. BOX 3008. FLORIDA CITY. FL 33034 N/A Expiration Date Address

4. identification of System Reactor Coolant System Quality Group
5. (a) Applicable Construction Code ANSI B31 1 19 55 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980, Edition, Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components ASME Name of Name of Manufacturer Notional Repaired. Code Other Year Component Manufacturer Serial No. Board Replaced, Starrtped Identification Built (Yes or No. or Replacement No)

Pzr.Safety Valve Crosby N/A N/A RV-4-551A N/A Replaced No Pzr.Safety Valve Crosby N/A N/A RV-4-551A N/A Replacement No 7 Description of Work Replaced (8) St.uds and (16) Nuts.

8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other Pressure pst Test Temp Degree's r NOTE: Supplemental sheets in form of lists. sketches, or drawings may be used. provided (1) size is 8 1/2 in.

X 1lin. (2) information in items

~ 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. 92-012-4

Page 2 of 2 FORM NIS-2 (Back)

9. Remarks Mechanical connection, No welding performed.

Applicobte Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this p conforms repoir or replacement to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Ger tificate of Authorization N o. N/A Expiration Date Signed Date ~ 19 Owner or Owner's Designee. Title CERTIFICATEOF INSERVICE INSPECTION I. the undersigned, holding a valid commission issued by the Notional Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade County, Florida and employed by Arkwri ht Mutual Insurance Com an of Norwood. hiA.

have inspected the components described in this Owner's Report during the period to July 29. 1991 ~ and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective. measures described in this Owner's Report in accordance with the requirements of ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with the inspection.

Factory hiutual System Commissions 6230 (N I cctor's Signature Notional Board. State. Province. and Endorsements

Page 1 of 2 FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI FLORIDA POWER & LIGHT Date March 30, 1992 Name P.O. BOX 029100, MIAMI, FL 33102 Sheet I of Address TURKEY POINT 4

2. Plant Unit Name P.O. BOX 3088, FLORIDA CITY, FL 33034 PWO: 2270 WA¹ 920108163430 Address Rertor araattizatioo P.O. No.. Job No. etc.

Work Performed by FLORIDA POWER & LIGHT Type Code Symbol Stamp N/A Name Authorization No. N/A P.O. BOX 3080, FLORIDA CITY. FL 33034 N/A Expiration Dote Address 4, Identification of System Intake Cooling Water Quality Group

5. (a) Applicable Construction Code ANSI B31.1 19 55 Edition, N/A Addenda, N/A Code Case (b) Applicoble Edition of Section Xt tftilized for Repairs or Replacements 1980, Edition, Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components ASME Name of Manufacturer National Repaired, Code Name of Other Year Stamped Component Manufacturer Serial No. Identification Built Replaced, No. (Yes or or Replacement No)

Gate Valve Jenkins Valve N/A N/A 3-50-364 1989 Replaced No Gate Valve Jenkins Valve N/A N/A 3-50-364 1991 Replacement No 7 Description of Work Replaced valve at, tag location 3-50-364 due to excessive seat leakage.

t

8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure X Other Pressure psl Test Temp pg Degree's r NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in.

X 11in.. (2) information in items 1 through 6 on this report is included on each sheet. and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. 92-013-4

Page 2 of 2 FORM NIS 2 (BCICk) hfechanical connection, No welding performed.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this p conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No N/A N/A Expiration Date Signe Date 19 Owner or Owner's Designee. Title CERTIFICATE OF INSERVICE INSPECTION I~ the undersigned, holding a valid commission issued by the Notional Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade County, Florida and employed by Arkwri ht hfutual Insurance Com an of Norwood. hfA.

have inspected the components described in this Owner s Report during the period """'y to Februa 24, 1992 ~ and state that to the best of my knowledge and belief.

the Owner hos performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code.Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied. concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind a ising from or connected with the inspection.

Factory hfutual System Commissions 8230 N) I) i actor's Signature National Board. State. province. and Endcrsernents

Page1 of 2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI Owner FLORIDA POWER & LIGHT Date April 29, 1992 P.O. BOX 0 9100 MIAMI F 3315 Sheet of Address Plant TURK POINT Unit Name CWO: 500820 PC/M: 89-059 P.O. BOX 3088 FLORIDA CITY FL 33034 MPIL NO. 92-036M N-88-0165 Address Repair Organization P.O. No.. Job No., eto.

3. Work Performed by Type Code Symbol Stamp Name Authorization No.

Expiration Date N/A

4. Identification of System RESIDUAL HEAT REMOVAL Quality Group B
5. (a) Applicable Construction Code B31 1 19 55 Edition, NA Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980, Edition, Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Repaired Board Year Replaced, Component Manufacturer Serial No. Identification Built Stamped No. or Replacement (Yes or No)

Est.

N/A N/A N/A TB-1 REPLACEMEN NO 1970 REPLACED UNIDENTIFIED SUPPORT WITH NEW SUPPORT TB-1

8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other N/A Pressure psi Test Temp. Degree's F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in.

X 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

92-014-4

Page2of2 FORM HIS-2 (Back)

'marks Examinations performed by FPL Construction Quality Control personnel.

Applicable Manufacturer's Oata Reports to be attached ALLWELDING WAS PERFORMED IN ACCORDANCE WITH THE FPL WELD CONTROL MANUALAND SITE PROCEDURES.

CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENT conforms

'o the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No N/A Expiration Date N/A Signed A. ~ w4n JcJc J &vr(rg 4'dr Date ,19 ~+

Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade Coun Florida and employed by Arkwri ht Mutual Insurance Com an of Norwood MA have 'ect the components described in this Owner's Report during the period / %5z Z

1 to , and state that to the best of my knowledge and belief, the ner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes anywarranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Futhermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Factory Mutual System Commissions I tor's Signature National Board, State, Province, and Endorsements Date

Page 1 of 2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI FLORIDA POWER & LIGHT August 18 1992

1. Owner Date ~

Name P.O. BOX 029100, MIAMI, FL 33102 Sheet 1 of 1 Address TURKEY POINT

2. Plant Unit Name P.O. BOX 3088, FLORIDA CITY, FL 33034 PWO: 2343 WAss 920530125710 Address Repair Organization P.O. No. ~ Job No. elc.

Work Performed b FLORIDA POWER & LIGHT NI A Type Code Symbol Stamp Npme Authorization No. NI A P.O. BOX 3088, FLORIDA CITY, FL 33034 NI'A Expiration Dote Address

4. Identification of Syste Intake Cooling Water Quality Group C
5. (a) Applicable Construction Code ANSI B31 1 ~ 1955 Edition, NiA Addenda, NI A Code Case (b) Applicable Edition of Section XI Utilized for Repairs orReplacements 1980, Edition, Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components ASME Name of Name of Manufacturer Nationa Repaired, Code Other Year Component Manufacturer Serial No. Board Replaced, Stomped Identification Built (Yes or No. or Replacement No)

Gate Vlv Jenkins R92-0704 N j'A 4-50-377 Unk. Replaced No I

Gate Vlv Jenkins R92-04 12 NI/A 4-50-377 Unk. Replacement No 7 Descf iption of 'Work RePlaced valve at tag location 4-50-377 due to excessive seat leakage

8. Tests Conducted: Hydrostatic Pneumatic Nominal Operatintressure X Other e

Pressure ps l Test Temp Dg 'egree' r NOTE: Supplemental sheets in form of lists, sketches, or drawings may beused, provided (1) size is 8 1Ir2 in.

X 11in., (2) information in items 1 through 6 on this report isincluded on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of thiform. 92-015-4

Page 2 of 2 FORM NIS-2 (Back)

9. Remarks Applicable Manufacturer's Dala Reports to be attached We certify that the statements made in the report are correct and this re lacemenl conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp NI A Cerlificate of A or'i No.

NJ'A Expiration Date N/A Signed Owner or Owner's Designee, Tltt Date /'), 19~9 I~ the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade Count, Florida and employed by Arkwri ht Mutual insurance Com an of Norwood. MA.

have inspected the components described in this Owner's Report during theperio to Augusl 18.1992 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures describech this Owner's Report in accordance with the requirements of ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes anywarranty, expressed or implied, concerning the examinations and corrective measures described in thi&wners Report. Furlherlnore, neither the inspector nor his employer shall be liable in any manner for anypersonal injury or property damage or a loss of any kind aris' from or connected with the inspection.

Factory Mutual System Commissions 8230 N I rtnspec or's Signature National Board, Stale, Province. and Endorsements

FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI FLORIDA POWER & LIGHT Date 30 Sc-Pr 1.997-Nome P;O. BOX 029100, MIAMI, FL 33102 Sheet l of I Address TURKEY POINT

2. Plant Unit Name P.O. BOX 3088, FLORIDA CITY. FL 33034 Ao g$ 'af td sir Wo $ 'I O5$ '/$ 5 Address Repar Organization P.O. No., Job No. etc.

Work Performed by FLORIDA POWER & LI HT Type Code Symbol Stamp Nome Authorization No.

P.O. BOX 3088. FLORIDA CITY, FL 33034 Address

4. Identification of System a 7 4K'oocrdb m+7-aR. Quality Group
5. (a) Aaaticonte Construction Code re>dr dtg r r tg XS

~ Edition~Ad'ddenda.~+re Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980, Edition, Winter 1981 Addenda

6. identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Repaired, ASM'ode Year Component Manufacturer Serial No. Board ldentificotion Replaced, Stomped Built (Yes or No. or Replacement No)

AO i~~h'VDOOd.

f'rC4 C trplRAoes4& +id'+CQ gMa /f fed/C ~n~ r gpgg THEif57r-

~uArc.dr 41- p)oral e g74I

~egg, /'/ccrc dnerr

-fpfp ~PROC C Cs<7S M~de / Ie ~ 1-+>< ~ AC+

Ac%.4~~~<

8. Tests Conducted: Hydrostatic

'r

~ Pneum'atic Nominal Operating Pressure rrir

)( Other Pressure ~ nsi Test Temp Degrees F NOTE: Supplemental sheets in form of lists. sketches, or drawings may be used, provided (1) size is 8 1/2 in.

X 11in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. .7d-of~ p.>

px.-~- 'f

Page 2 of 2 FORM NIS-2 (EIack)

9. Remcrks HE<HRA f r 4C, coal>> ~'W r o 99pWbi4~ r E</ omar~

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this ~~~~~~ i conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A N/A Expiration Date Signed Date Owner or Owner's De ee, Title CERTIFICATE OF INSERVICE INSPECTION I~ the. undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade Count, Florida ond employed by Arkwri ht Mutual Insurance Com an of Norwood, MA.

have inspected the components described in this Owner's Report during the period to f ot /~g I99P- , and state that to the best of my knowledge and belief.

the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordonce with the requirements of ASME Code.Section XI.

By signing this certificate neither the inspector nor his employer makes any.warranty, expressed or implied. concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the inspector nor his employer shall be lioble in ony, manner for any personal injury or property damage a loss of any kind orising from or connected with the inspection.

Factory Mutual System Commissions 8230 N I Insp or's Signature Notionol Board, State, Province, ond fndorsements Da

0~ 0 ~  %  % +

g

~

~ ~

I. '

'l

~

~ I~ I I I I'

~ ~

I' 'I ~ ' ~ ~ ~ ~ ~

I I ~ III I I

~

~

~ ~

~ ~

I ~

~ ~

~ ' ~ '

~ ~ ~ ~ ~

~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~

~ ~ ~ ~ ~ ~ ~ ~ ~ ' ~ '

~ ~ ~ ~ ~ ~ ~ ~ ~

~ ~ ~ ~ ~

~ ~ ~ ~ ~ ~

~ ~ ~

~ ~ ~ ~ ~ ~

~ ~

~ ' ~

~ ~ ~ I ~ . ~ ~

~ ~ ~

'I ~

~ ~ ' ~ ~ '

~ ~ ~ ~ ~ ~ ~

~ '

~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~

~ 4 ~ ~ ~ ~ ~ ~ ~ ~ ~ 0

~age 2 of ".

FORM NIS-2 (EIack)

Remarks 4opncopie uonuioctvrer's opto Reports to pe ottocneo C i + CNfZ- OZ.

Pe&t f- thymic m CERTlFICATK OF COMPLIANCE We certify that the statements made in the report are correct and this confor..s

~ epar or replacement to the rules of the ASME Code,Section XI.

Type Code Symbol Stomp N/A Certificate Signed f A t iz ion Wi HH-Expiration Dote Date

0 er or Oener's Designee. Title CERTlFICATK OF lNSERVICE IHSPECTlON
l. the undersigned. holding a valid commission issued by the National Board of Boiler and Pressure Vessei inspectors and the State or Province of Dade Count, Florida and employed by I

Arksrri ht Mutual Insurance Com an of Norwood, MA.

have inspected the components described in this Owner's Repot't during the perio to m w tltz and state that to the best of my knowledge ana belief.

the Owner has performed examinotions and token corrective measures described in this Owner's Report in accoraonce with the requirements of ASME Code. Section Xl.

By signing this certificate neither the inspector nor his employer makes any warranty. expressed or i

implied. concerning the examinations and corrective measures described in this Owners Report. Furthermore.!

neither the inspector nOr his employer shall be liable in any manner for any personal injury or property damage or o loss of any kind arising from or connected with the inspection.

Factory Mutual System Commissions 8230 N I In ctcr s SiSnati/e Notionai Sacra. State, Province, ana Encorsements i 19~~~ I

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI FLORIDA POWER & LIGHT May 7, 1993 Hame P.O. BOX 029100, MIAMI, FL 33102 of Sheet 1 Address TURKEY POINT

2. Plant Unit Home P.O. BOX 3088 ~ FLORIDA CITY, FL 33034 WOss 92034800 PWOss 5461 Address Repair Organlzanon P.O. Ho.. Job Ho. ele.

3 'Work Performed b FLORIDA POWER & LIGHT Ni'A Type Code Symbol Stamp Hams Authorization No. NJ'A P.O. BOX 3088, FLORIDA CITY, FL 33034 N/'A Expiration Dote Address

4. Identification of Syste Spent Fuel Pool Coolin Quality Group C
5. (a) App(icable Construction Code ANSI 831.1 19 55 Edition. Nf'A Addenda. NJ'A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980 Edition, Winter 1981 Addenda

~

6. Identification of Components Repaired or Replaced and Replacement Components ASME Name of Name of Manufacturer National Other Repaired. Code Board Year Stamped Component Manufacturer Serial No. Identification Built Replaced, No. or Replacement (Yes or No)

Butterfly Valve Posi-Seal 56943-18 Nr A 4-820 1991 Replaced No Butterfly Valve Posi-Seal 56943-1A N/A 4-820 199 1 Replacement No

7. Description of Work Replaced valve at tag location 4-820 due to excessive seat leakage.
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other Pressure psi Test Temp Degree's F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 U'2 in.

X 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form 93-001-4

Page 2 of 2 FORM NIS 2 (Back)

Mechanical connection, no welding performed. Hydrostatic test tt04-SFPC-3326-H-03 Appltcabi ~ Manutacturer's Oala Reporls to be attached used to meet pressure test requirements CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this p m " conforms to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp Nr'A Certificate of Authorizati n No N/A NJ'A Expiration Date Signed Date ~< . 19 W Owner or Owner'slgnee. Title CERTIFICATE OF INSERVICE INSPECTION I. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade County, Florida and employed by Arkwri ht Mutual Insurance Com an of Norwood. MA.

have inspected the components described in this Owner's Report during theperio to April 2, 1993 . and state that to the best of my knowledge and belief.

the Owner has performed examinations and taken corrective measures described in this Owner's Reporl in accordance with the requirements of ASME Code, Section XI ~

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied. concerning the examinations and corrective measures described in this Owners Report. Furthermore neither the inspector nor his employer shall be liable in any manner for anypersonal injury or property damage or a loss of any kind ing from or connected with the inspection.

Factory Mutual Engineering Assoc Commissions NB 8230 N I speclor's Signature ttationat Board, State. Province, and Endorsements IP 19 PM

FORM NIS-2 OWNER'S REPORT FOR REPAtRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI Otrrrner FLORIDA POW R lr IGHT A ril 20. 1993 Name 1

Sheet of Address

2. Plant Unit Name P.O. BOX 3088 FLORIDA CITY FL 33034 CMO:

IIP I: 300567

- IN PCN:

If:

91-200 050608 Repair Organrsatren P.O. No.. Job No., etc.

3. Work Performed by Type Code Symbol Stamp Name Authorization No.

Expiration Date N/A Address REACTOR COOLANT SYSTEN

4. Identification of System
5. (a) Applicable Construction Code 19 55 Edition, N Addenda, N Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980, Edition, Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components National ASME Name of Name of Manufacturer Repaired, Code Other Year Component Board Replaced, Stamped Manufacturer Serial No. Identification Built No. r Replacement (Yes or SUPPORT ON EST RCS SYSTEN SR-400 1970 PLACENENT NO
7. Description of Work REPlACED SPRING CAN SUPPORT NARK fSR-400 I/A/if PC/It 91-200

Page 2 of 2 FORM NIS-2 (Back) 9 Fternarks EXAMINATIONS PERFORMED BY FPL CONSTRUCTION QUALITY CONTROL PERSONNEL Applicable Manufacturer's Data Reports to be attached CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed Date Owner or Owner's Designee. Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade Coun Florida and employed by Arkwri ht Mutual Insurance Com an of Norwood MA have inspected the components described in this Owner's Report during the period to 4/20/93 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes anywarranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Futhermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

FACTtRY MlTUAL EMItKERIM AS Ins ior's Signature Commissions National Board, State, Province, and Endorsenten Dat

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI Ottttinef

2. Plant FLORI A POWER Name Name 8t IGHT P.O. BOX 3088 FLORIDA CITY FL33034 Date Sheet Unit CMO:

~ oi 501016 WO: 93002706 Address Repair Orgartizaron P.O. No., Job No., ere.

3. Work Performed by Type Code Symbol Stamp Name Authorization No.

Expiration Date N/A

. Address

4. Identification of System
5. (a) Applicable Construction Code 19 55 Edition. N Addenda, Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980, Edition, Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components National ASME Name of Name of Manufacturer Repaired, Other Year Code Component Board Replaced, Stamped Manufacturer Serial No. Identification Built No. r Replacement (Yes or ITEN f EST SGC4E210C WESTINGHOUSE 6518293 1970 REPULCED NO 7 Description of Work REPLACED 5 PRINART HAN MAY 8 TS N S S7. 8, 10, 12 and HOT LEG f 12 93-007-4

Page 2 of 2 FORM NIS-2 (Back)

9. Remarks EXAMINATIONS PERFORHED BY FPL CONSTRUCTION QUALITY CONTROL PERSONNEL Applicable Manutacturer's Data Reports to be attached CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEHENT conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed Owner or Owner's Designee, Title Date 5'l CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade Coun Florida and employed by Arkwri ht Mutual Insurance Com an of Norwood MA have inspected the components described in this Owner's Report during the period 4/2B/93 to 5/I/93

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes anywarranty, expressed or implied. concerning the examinations and corrective measures described in this Owners Report. Futhermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arisi from or connected with this inspection.

FACT%tv MEAL EMIFKERIM ASS r's Signature Commissions Ins Naticeat Board, State, Province, and Endorsements

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI FLORIDA POWER R LIGHT 05y/03/ 93 Name P.O. BOX 029100. MIAMI, FL 33102 Sheet I of Address TURKEY POINT

2. Plant Unit 4 Name P.O. BOX 3088, FLORIDA CITY, FL 33034 CWO:501031, WO: 93012484, CR93-0341 Address Reryalr Oreanrzauan P.O. Na. ~ Jab Na. etc.

3 Work Performed b BECHTEL CONSTRUCTION INC. N/'A Type Code Symbol Stamp Name Authorization No. N/'A P.O.BOX 3218, FLORIDA CITY, FL 33034 N/'A Expiration Date Address

4. Identification .of Syste RESIDUAL HEAT REMOVAL Quality Group 8
5. (a) Applicable Construction Code ANSI 831 1 1955 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs orReplacements 1980, Edition, Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components ASME Name of Name of Manufacturer Nationa Repaired, Code Other Component Manufacturer Serial No. Board Replaced, Stomped Identification Bu,.lt (Yes or No. or Replacement No)

MSA  ; N/'A Nr/A N/'A MSA 4-1016 N/A Replaced MSA PSA N/'A '/'A , MSA,4- 10 16 N/'A Replacement

~ ~

REPLACED PSA-10 TRANSITION TUBE TO SNUBBER BOLTS (4 BOLTS) ON SNUBBER 4-1016

8. Tests Conducted: Hydrostatic Pneumatic Nominal Operatintt'ressure Other tr Pressure N/A psi Test Temp trite Degree' T NOTE: Supplemental sheets in form of lists, sketches, or drawings may beused, provided (1) size is 8 I//2 in.

X 11in., (2) information in items 1 thraugh 6 on this report isincluded on each sheet. and (3) each sheet is numbered and the number of sheets is recorded at the top of thiform. 93-008-4

Page 2 of 2 FORM NIS 2 (Back)

9. Remarks Applicable Manutacturer's Oata Reports to be attached 8MV3tJCd 98 0'f 0WARM We certify that the statements made in the report are correct and this ro lacemont conforms repair or replacement to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp NJ'A Certificate of Authorization No. Ni'A NI'A Expiration Date Signed Owner or Owner's Be gn ~. Tilts

'86RS JSPFA J8 0'PMRPPM PAV5 85'SJ0P',

the undersigned. holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade Coun, Florida and employed by Arkwri ht Mutual Insurance Com an of Norwood. MA.

hove inspected the components described in this Owner's Report during theperio * "~

to 1 LtAT 9$ , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures describe& this Owner's Report in accordance with the requirements of ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes anyNarranty. expressed or implied, concerning the examinations and corrective measures described in thiDwners Report. Furlhermore, neither the inspector nor his employer shall be liable in any manner, for anypersonal injury or property damage or a loss of any kind arisi g from or connected with the inspection.

Factory Mutual System Comlnissions 8230 N I Inspector's Slgnaluro 'tattonot Board, Stat~, Province, and Bndorsomonts

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xi F ORIDA POWER & LIGHT 5/3/93 arne Date Sheet of Address

2. Plant T 4 Name Unit P.O. BOX 3088 FLORIDA CITY FL33034 CNO: 501031 M/0: 91058143 CR-93-359 NCR-91-0279 Address Repas Organstat)on P.O. No. Jotr No. etc.

~ ~

3. Work Performed by Type Code Symbol Stamp Name Authorization No.

Expiration Date NIA Address

4. Identification of System
5. (a) Applicable Construction Code B31 19 55 Edition, Ns'A Addenda, (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980, Edition, Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components National epaired ASME Name of Name of Manufacturer Other Year Code Component Manufacturer Serial No. Board Replaced Stamped Identification Built No. r Replacement (Yes or INR PIPING SR-2 1970 REPLACED REPLACED TRANSITION TUBE PER NCR-91-0279 HODIFIED FRONT BRACKET
7. Description of Work PER CR-93-359 93-009-4

Page 2 of 2 FORM NIS-2 (Back)

9. Remarks ALL KELDIII6 PERFORMED PER FPL WELD CONTROL MANUAL.

Applicable Manufacturer's Data Reports to be attached CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp N/A Certificate of A orization No. N/A Expiration Date N/A Signed SPY-C~~ z/op Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade Coun Florida and employed by Arkwri ht Mutual Insurance Com an of Norwood MA have inspected the components described in this Owner's Report during the period to , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes anywarranty, expressed or implied. concerning the examinations and corrective measures described in this Owners Report. Futhermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

FrtCTUIY NJ1UAL ENRItKERIM Ass Commissions 19 F~

Inspector's Signature National Board, State, Province, and Endorsements

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI Ovriner F ORIOA POWER & IGHT 04/30/93 Name Date Sheet of Address

2. Plant Unit Name P.O. BOX 3088 FLORIDA CITY FL33034 93008781 CKO: 501038 Address Repair Organuaton p.o. No., Job No. etc.

~

3. Work Performed by Type Code Symbol Stamp Name Authorization No.

Expiration Date N/A Address

4. Identification of System
5. (a) Applicable Construction Code 19 55 Edition Addenda, N Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980. Edition, Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components National ASME Name of Name of Manufacturer Other Year Repaired, Code Component Manufacturer Board Replaced, Stamped Serial No. Identification Built No. r Replacement (Yes or 4-50-350 HENRY PRATT NA REPLACED NO TRITON 4-50-350 HENRY PRATT 7-61465-1 XR-70 1986 REPLACEMENT NO ST I-ta" STUD (3) 1970 REPLACED NO I-s4" STUD (3) R92-5338 1993 REPLACEMENT NO REPLACED EXISTIN6 30 BUTTERFLY VALVE 93-010-4

Page 2 of 2 FORM NIS-2 (Back)

9. Remarks ALL MELDIN6 MAS PERFORHED IN ACCORDANCE MITH FPL MELD CONTROL MANUAL.

Applicable Manufacturer's Data Reports to be attached CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this REPULCENENT conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp N/A Certificate uthorization No. N/A Expiration Date N/A Signed I

Owner or 0'wner's Designee, ills

~ D<<

CERTIFICATE OF INSERVICE INSPECTION I. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade Coun Florida and employed by Arkwri ht Mutual Insurance Com an of Norwood MA have inspected the components described in this Owner's Report during the period to , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes anywarranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Futhermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising om or connected with this inspection.

FACTCRY MJIUAL EMIIFKERIraI AS Commissions National Board, State, Province, and Endorsements

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI Ovgner F ORIDA POWER & IGHT 04/16/93 Name I

1 1

Sheet of addreSS

2. Plant INT Unit shame P.O. BOX 3088 FLORIDA CITY FL 33034 93010174 OIOt 501038 Address Rope>>organcrdon pO. No.. Job No.,ere.
3. Work Performed by Type Code Symbol Stamp Name Authorization No.

Expiration Date N/A Address 4 identlcatfon of System ICK SYSTEM

5. (a) Applicable Construction Code B3 19 55 Edition, N Addenda, (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1980, Edition, Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components National ASME Name of Repaired, Name of Manufacturer Other Year Code Board Replaced, Stamped Component Manufacturer Serial No. Identification Built No. r Replacement {Yes or HENRY PRATT 2463-IR 1970 REPLACED NO TRITON 4-50-340 HENRY PRATT 50270-1-1 XR -70 1992 REPLACBKNT NO EST.

I-W STIIOS (i6) 1970 REPLACED NO I-Q'KDS (16) R92-5338 1992 REP LACEHENT NO

7. Description of Work REPLACEO EXISTING 30'UTTERFLY VALVE 93- <<t-4

Page 2ol2 FORM NlS-2 (Back) 9 Ftemarks ALL MELDING MAS PERFORMED IN ACCORDANCE MITH FPL MELD CONTROL SNU Apptcabte Manufacturer's Data Reports to be attached CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this REP LACENENT conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No. Expiration Date N/A Signed ,. ~/P~>

Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade Coun Florida and employed by Arkw ht Mutual Insurance Com an of Norwood MA have inspected the components described in this Owner's Report during the period to , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes anywarranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Futhermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

FACTLY l4JTUAL EMIFKERIM3 AS Commissions I tcf see~,,a:~f8 Dat / ~90'5

FORM NIS-2 OWNER'S REPORT FOR REPAlRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI FLORIDA POW R & LIGHT 05/02/93 Name 1

Sheet of Address

2. Plant INT Unit 4 Name P.O. BOX 3088 FLORIDA CITY FL 33034 93006364 CMO: 501038 Address Repair Orttancarion P.O. No.. Job No., erc.
3. Work Performed by Type Code Symbol Stamp Name Authorization No.

Expiration Date N/A Address

4. Identification of System
5. (a) Applicable Construction Code 19 55 Edition, Addenda, (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980, Edition, Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components National ASME Name of Name of Manufacturer Other Repaired, Year Code Component Manufacturer Board Replaced, Stamped Serial No. Identification Built No. r Replacement (Yes or I-3s STUD (3) NA 1970 REPLACED NO I-Q'TUD (3) R87-6683 1987 REPULCEMENT NO I-ttr" STUD (15) 1970 REPLACED I-4" STUD (15) NA R92-4775 1992 REPLACEMENT NO I-Ls" Bolt (7) 1970 REPLACED I-t4" BOLT (7) R89-0222 1989 REPLACEMENT NO 1-t4" NUT (1) 1970 REPLACED NO I-Q NUT (1) R93-1208 1993 REPLACEMENT I-4 NUT (17) 1970 REPULCED NO I-Q" NUT (17) R93-1392 1993 REPLACEMENT NO 7 Descrfptjon of Work REPULCED BOLTIIfG MATERIAL DURING REINSTALLATION OF PIPING IN ICM SYSTEM FOR CRAML 'HIROUGH INSPECTIONS.

Page 2of 2 FORM NIS-2 (Back)

9. Remarks NO MELDING PERFORMED. ALI HECHANICAL CONNECTIONS Applicable Manufacturer's Data Reports to be attached CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this REPIACEHENT conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp N/A Certificate of Au rization No. N/A Expiration Date N/A Signed Owner or Owner's Designee, Title Date + ~ +,19 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade Coun Florida and employed by Arkwri ht Mutual Insurance Com an of Norwood MA have 'pected the compgn nts described in this Owner's Report during the period 1

~/ r/5'o

, and state that to the best of my knowledge and belief, the Owner performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes anywarranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Futhermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

FACHKY MJTUAL E743IPKERIM3 AG Commissions l ior's Signature National Board, State, Province, and Endorsements

/ 19~$

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xi FLORIDA POW R & LIGHT 05/04/93 Name 1 1 Sheet of

2. Plant 4 Unit Name P.O. BOX 3088 FLORIDA CITY FL33034 CMO: 501031 ~ M/0: 93012856, CR-93-349 Address Reparr Oreanrsaren p.O. No.. Joe No., ere.
3. Work Performed by Type Code Symbol Stamp Name Authorization No.

Expiration Date N/A Address 4 identjficatjonof System SYSTEM 047,CVCS

5. (a) Applicable Construction Code 19 55 Edition, NA Addenda, N/IA Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980, Edition, Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components National ASME Name of Name of Manufacturer Repaired, Other Year Code Component Board Replaced, Stamped Manufacturer Serial No. Identification Built No. r Replacement (Yes or 3"-CH- EST.

CVCS PIPIN6 - 1970 REPAIRED 1403 7 NO FILLED OUT LINEAR INDICATION ON MELD 7

7. Description of Work 93-013-4

Page 2 of 2 FORM NIS-2 (Back)

IIO lfELDING PERFORHED

9. Remarks Applicable Manufactur'er's Data Reports to be attached CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp N/A Certificate Authorization N/A Expiration Date N/A Signed Owner or Owner's Designee, Title Date ~ +~ .19 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade Coun Florida and employed by Arkwri ht Mutual Insurance Com an of Norwood MA have inspected the components described in this Owner's Report during the period to , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Futhermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind 'sing from or connected with this inspection.

FACTORY MllUAL EMItKERIM ASS Commissions National Board, State, Province, and Endorsemen

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl FLORIDA POW R & IGHT 05/03/93 Ovrner Date Name Sheet of Address

2. Plant INT Unit Name P.O. BOX 3088 FLORIDA CITY FL 33034 CNO 501031s N/0 93012854s CR 93 0324 Address Repair Ortianizaien P.O. No., Job No. etc.

~

3. Work Performed by Type Code Symbol Stamp Name Authorization No.

Expiration Date NIA Address

4. Identification of System
5. (a) Applicable Construction Code B3 19 55 Edition, N Addenda, '

Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980, Edition, Winter 1981 Addenda

6. Identification of Components Repaired or Replaced and Replacement Components National ASME Name of Name of Manufacturer Other Repaired, Year Code Component Manufacturer Board Replaced, Stamped Serial No. Identification Built No. r Replacement (Yes or SAFETY INJECTION EST PIPING -SI-1402-1 1970 REPAIRED tl0 REHOVED LItIEAR ItIDICATION BY FILING.
7. Description of Work 93-014-4

Page 2 of 2 FORM N1S-2 {Back)

9. Remarks IIO MELDIIIG PERFORHED Applicable Manufacturer's Data Reports to be attached CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp N/A Certificate uthorization No. N/A Expiration Date N/A Signed FPr c Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade Coun Florida and employed by Arkwri ht Mutual Insurance Com an of Norwood MA have inspected the components described in this Owner's Report during the period to , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes anywarranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Futhermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

FACTCRY MJTUAL EMIPKERIM) ASS

's Signature Commissions Ins National Board, State, Province, and Endorsements Dat 19~7

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI FLORIDA POWER 8c LIGHT Dote Name P.O. BOX 029100, MIAMI, FL 33102 Sheet 1 of Address TURKEY POINT

2. Plant Unit Name P.O. BOX 3088. FLORIDA CITY, FL 33034 Woss 90054278 Pwoss 2864 Address Repair Organtzauon P.O. No.. Job No. etc.

3 Work Performed b FLORIDA POWER & LIGHT N/'A Type Code Symbol Stamp Name Authorization No. N/'A P.O. BOX 3088, FLORIDA CITY, FL 33034 N/A Expiration Date Address

4. Identification of Syste Spent Fuel Pool Coolin Quality Group C
5. (a) Applicable Construction Code ANSI 831 1 1955 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980. Edition, Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components ASME Name of Name of Manufacturer National Other Repaired, Code Year Stomped Component Manufacturer Serial No. Board Identification Replaced.

Built (Yes or No. or Reptacement No)

Gate Valve Aloyco 68M3304 N/A 4-742 N/'A Replaced No Gate Valve Aloyco C1118 N/'A 4-742 1992 Replacement No

7. Description of Work Replaced valve at tag location 4-742 due to excessive seat leakage.

s

8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other Pressure tgg pst Test Temp Tg g Degree's F NOTE: Supplemental sheets in form of lists. sketches, or drawings may be used. provided (1) size is 8 1/'2 in.

X 11 in., (2) information in items I through 6 on this report is included on each sheet. and (3) each sheet is numbered and the number of sheets is recorded at the top of this form 93-015-4

Page 2 of 2 FORM NIS-2 (Back)

9. Remarks All welding was performed in accordance with the FPL Weld Control Manual Applicable Manufacturer's Data Reports to be attached and Site Procedures. Hydrostatic test st04-SFPC-3326-H-03 CERTIFICATE OF COMPLIANCE certify that the statements made in the report are correct and this p e We - conforms repair or replacement to the rules of the ASME Code.Section XI.

Type Code Symbol Stamp Nl'A Certificate of Auth rizat n No NJ'A Nf'A Expiration Date Signe Date 19+

Owner or Owner's Des gnee. Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade County. Florida and employed by Ark'wri ht Mutual Insurance Compan of Norwood. MA.

have Inspected the components described in this Owner s Repoa during theperlo "'""'y 8. 1993 to April 2 ~ 1993 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures'described in this Owners Report. Furthermore neither the inspector nor his employer shall be liable in any manner for anypersonal Injury or property damage or a loss of any kin ising from or connected with the inspection.

Factory Mutual Engineering Assoc.

Commissions NB 8230 N I nspeclor's Signature National Board. Stale, Province. and I:ndorsements

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xt

/3- c'ig-p~ner FLORIDA POWER & IGHT Date Name Sheet

2. Plant P I Unit Name P.O. BOX 3088 FLORIDA CITY FL33034 Q- 3- I5 Me ".v 0 R,iQ Repair Organ aron P.O. No.. Jcb No., etc.
3. Work Performed by Type Code Symbol Stamp Name Authorization No.

Expiration Date N/A

4. Identification of System L
5. (a) Applicable Construction Code 19 55 Edition, NA Addenda, N Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980, Edition, Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components National ASME Repaired, Code Name of Name of Manufacturer Other Year Board Replaced, Stamped Component Manufacturer Serial No. Identification Built No. r Replacement (Yes or lbiUZ.5- F-S T voPPr a.q H-HZ I-c Z.
7. Description of Work

Page 2 of 2 FORM NlS-2 (Back)

9. Remarks Applicable Manutacturer's Data Reports to be attached CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed Date ,19 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I,

Inspectors and the State or Province of Arkwri ht Mutual Insurance Com an Dade Coun of Florida 'nd the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Norwood MA employed by have inspected thy components described in this Owner's Report during the perio to r

( /1 , and state that to the best of my knowledge and belief, the Owne as performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes anywarranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Futhermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

FACAKY ICJTUAL E?4)I~I~ AS-Commissions 8230 In tor's Signature National Board, State, Province, and Endorsemen 4/ 19~&

FORM NlS-2 OWNER'S REPORT FOR REPAlRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

2. Plant F ORIDA POWER 8 Name Address Name IGHT P.O. BOX 3088 FLORIDA CITY FL 33034 Address Date Sheet Unit

'f l

e-Repatr Organfarrrion P.O. No., Job N .. eto.

c'p5

3. Work Performed by Type Code Symbol Stamp Name Authorization No.

Expiration Date N/A

4. Identification of System Address

/

5. (a) Applicable Construction Code -

19 55 Edition, N Addenda, Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980, Edition, Winter 1981 Addenda

6. Identification of Components Repaired or Replaced and Replacement Components National ASME Repaired, Coda Name of Name of Manufacturer Other Year Board Replaced, Stamped Component Manufacturer Serial No. Identification Built No. r Replacement (Ye or CCcx c

/'.

Description of Work )

Otht r 4 ~~ Z~ A CM rr/ 5 Ie 7).g I P- g

Page2of2 FORM N(S-2 (Back)

g. Remarks *'Hc/P L~C.

Applicable Manutactur r's Data Reports to be attached A-vC'l t> to=

~/ rA (AC' ("

CZ .

8-CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this conforms to the rules of the ASME Code,Section XI. repair or replacement N/A Type Code Symbol Stamp Certificate of Authorization No. N/A Expiration Date N/A Signed

,Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade Coun Florida and employed by Arkwri ht Mutual Insurance Com an of Norwood MA have inspected the components described in this Owner's Report during the period to , and state that to the best of my knowledge and belief.

the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes anywarranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Futhermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage, or a loss of any kind arising from or connected with this inspection.

FACAKY MJAJAL EtaIIIKERItKI As Cc~ Commissions tor's tgnature National Board, State, Province, and Endorsements m'4- ig~

I a

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI FLORIDA POW R & LIGHT Date 1 1 Sheet of

2. Plant Unit Name P.O. BOX 3088 FLORIDA CITY FL 33034 CR-93-385, N/0: 93013371, CNO: 501031 Address Reparr Organizrarcn p.o. No.. Jcb No., etc.
3. Work Performed by Type Code Symbol Stamp Name Authorization No.

Expiration Date N/A Address 4 identification of System STEAM BLNDSO SYS f 071

5. (a) Applicable Construction Code 19 55 Edition, Addenda, Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980, Edition, Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components National ASME Name of Name of Manufacturer Other Year Repaired, Code Component Manufacturer Board Replaced, Stamped Serial No. Identification Built No. r Replacement (Yes or 8102B- EST SUPPORT 18014 -421-01 1971 REPAIR NO MOVE EXISTING REAR BRACKET TO ACHIEVE PROPER "L" DIMENSION '.

Description of Work

Page 2of2 FORM NIS-2 (Back)

9. Remarks ALL XELDIllG PERFORNED IN ACCORDANCE MITH FPL NELD CONTROL NNUAL Applicable Manufacturer's Data Reports to be attached CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed Owner or Owner's Designee, Title Date ~~ ~ ,19 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel, Inspectors and the State or Province of Dade Coun Florida and employed by Arkwri ht Mutual Insurance Com an of Norwood MA to S'- //-0'3 . and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Futhermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

FACftKY NllUAL EMII~IMASS Commissions National Board, State, Province, and Endorsemenis 19~%

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI FLORIDA POWER & LIGHT 05/13/93 Name 1

Sheet of

2. Plant Unit Name P.O. BOX 3088 FLORIDA CITY FL33034 PC  : 93-094 MO: 93013274 Address Repair Organizarien p.o. No., Job No.. ere.
3. Work Performed by Type Code Symbol Stamp Name Authorization No.

Expiration Date N/A Address CVCS

4. Identification of System
5. (a) Applicable Construction Code 19 Edition, N Addenda, Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980, Edition, Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components National AS ME e paired Name of Name of Manufacturer Other Year Code Component Manufacturer Board Replaced, Stamped Serial No. Identification Built No. r Replacement (Yes <<

EST.

4-VCH-62 1970 REPLACED IIO 4-VCH-62 1993 REPLACEHEHT HO EST.

PIPIff6 CVCS 3-CH-1403 1970 REPAIRED fIO

7. Description of Work REPULCED SUPPORT 4-VCH-62 / REPAIRED CVCS PIPIfi6

Page 2of2 FORM HIS-2 (Back)

9. Remarks ALL MELDIX6 PERFORMED IX ACCORDANCE MITH FPL MELD CONTROL HAXUAL Applicable Manufacturer's Data Reports to be attached CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed Date

/ Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade Coun Florida and employed by Arkwri ht Mutual Insurance Com an of Norwood MA to , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes anywarranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Futhermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind 'sing from or connected with this inspection.

FACAKY MlTUAL ~ItKERIM3 ASS tor's Signa Commissions re National Board, State, Province, and EndoisemenL.

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI FLORIDA POWER & LIGHT May 18 1993 0 t Name P.O. BOX 029100, MIAMI, FL 33102 Sheet 1 of Address TURKEY POINT

2. Plant Unit Nome

'.O. BOX 3088, FLORIDA CITY, FL 33034 WOss 93012089 PWOss 6253 Address Repair Organlzatlon P.O. No., Job No. elc.

3 Work pel fol med b FLORIDA POWER & LIGHT NiA Type Code Symbol Stamp Name Authorization No. Nt'A P.O. BOX 3088 FLORIDA CITY, FL 33034 N/'A

~

Expiration Date Address

4. Identification of Syste Main Steam Quality Group B
5. (a) Applicable Construction Code ANSI 831 1 1955 Edition, NiA Addenda. NiA Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980. Edition, Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components ASME Name of Name of Manufacturer National Other Repaired. Code Board Year Stamped Component Manufacturer Serial No. Identification Built Replaced.

No. or Replacement (Yes or No)

Stop Check Vlv. Schutte/'Koerting NiA NiA POV-4-2605 Nr'A Replaced No

7. Description of Work Replaced Bonnet studs and nuts.
8. Tests Conducted: Hydrostatic Pneumatic~ Nominal Operating Pressure Other Pressure psl Teel Temp Degree's p NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 Ii2 in.

X 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of stteets is recorded at the top of this form 93-020-4

FORM NIS 2 (Back)

9. Remarks Mechanical connection, no welding performed.

Applicable Manufaclurer's Dolo Reports to be allached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this p m " conforms repair or replacemenl to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/IA Certificate of Authorization No. N/'A N/'A Expiration Date Signed 93 Owns r Owner's DesIgnee. Tille CERTIFICATE OF INSERVICE INSPECTION I~ the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade County, Florida and employed by Arkwri ht Mutual Insurance Compan of Norwood, MA.

have inspected the components described in this Owner s Repoa during theperlo AP to Ma 16, 1993 , and state that to the best of my knowledge and belief.

the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code.Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore neither the inspector nor his employer shall be liable in any manner for anypersonal injury or property damage or,a loss of any kind arising from or connected wilh the inspection.

Factory Mutual Engineering Assoc Commissions NB 8230 N I I eclor's Signature Nallonol Board. Slale. Province. and fndorsemenls 19

Page 1 of 2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI FLORIDA POWER & LIGHT May 18, 1993 Name P.O. BOX 029100. MIAMI, FL 33102 Sheet t ot Address TURKEY POINT

2. Plant Unit Name P.O. BOX 3088, FLORIDA CITY, FL 33034 Woss 93012088 PWOss 6265 Address Repatr Organization P.O. No., Job No. etc.

3 Work Performed b FLORIDA POWER & LIGHT Npp'A Type Code Symbol Stamp Name Authorization No. N/A P.O. BOX 3088, FLORIDA CITY, FL 33034 N/'A Expiration Date Address

4. Identification of Syste Main Steam Quality Group 8
5. (a) Applicable Construction Code ANSI 831 1 1955 Edition. NiA Addenda. NiA Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980, Edition, Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components ASME Name of Name of Manufacturer National Other Year Repaired, Code Board Replaced, Stamped Component Manufacturer Serial No. Identification (Yes or No. or Replacement No)

Stop Check Vlv. Schuttei'Koerting N/'A N/'A POV-4-2606 NiA Replaced

7. Description of Work Replaced Bonnet studs and nuts.
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other Pressure psl Test Temp Degree's F NOTE: Supplemental sheets in form of lists. sketches, or drawings may be used. provided (1) size is 8 1/'2 in.

X 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form 93-021-4

Page 2 of 2 FORM NIS 2 (Back)

9. Remarks Mechanical connection, no welding performed.

Applicable Manufacturer's Data Reports to be attached t

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this P " conforms repair or replacement to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/'A Certificate of Authorization o.

N/'A N/'A Expiration Date Signed er or Owner's Destttnee. Title Oate S= 1g-Ie CERTIFICATE Of INSERVICE INSPECTION I. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Oade County, Florida and employed by Arkwri ht Mutual Insurance Com an of Norwood, MA.

have inspected the components described in this Owner s Repoa during theperlo Ap"'o Ma 15, 1993 . and state that to the best of my knowledge and belief.

the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore neither the inspector nor his employer shall be liable in any manner for anypersonal injury or property damage a loss of any kind ari ing from.ol'onnected with the inspection.

factory Mutual Engineering Assoc Commissions NB 8230 N I Inspector's Stttnature Nottonot Board. State. Province. and Endorsements

Page 1 of 2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI FLORIDA POWER & LIGHT May 18, 1993 Name P.O. BOX 029100, MIAMI, FL 33102 Sheet 1 of Address TURKEY POINT

2. Plant Unit Name P.O. BOX 3088, FLORIDA CITY, FL 33034 Woss 92032190 PWOIs 9901 Address Repatr Organization P.O. No., Job No. ~ Ic.

Performed b FLORIDA POWER & LIGHT N/'A Type Code Symbol Stamp Name Authorization No. N//A P.O. BOX 3088, FLORIDA CITY, FL 33034 N/'A Expiration Date Address

4. Identification of Syste Intake Cooling Water Quality Group C
5. (a) Applicable Construction Code ANSI B31 1 1955 Edition. N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980, Edition, Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components ASME Name of Name of Manufacturer National Other Repaired, Cade Board Year Stamped Component Manufacturer Serial No. Identification Built Replaced.

No. or Replacement (Yes ar No)

Gate Valve Walworth N/'A N/'A 4-50-325 N/ A Replaced No Gate Valve Walworth N/'A N/'A 4-50-325 N/'A Replacement

7. Description of Work Replaced valve at tag location 4-50-325.
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure X Other pressure Nominal p st Teef Temp "em'"e Degree'e T NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/'2 in.

X 11 in., (2) information in items 1 through 6 on this report is included on each sheet. and (3) each sheet is numbered and the number of sheets is recorded at the top of this form 93-022-4

Page 2 of 2 FORM HIS-2 (Back)

9. Remarks Mechanical connections no welding performed.

Applicable Manufacturer's Data Reports to be attsched CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and '.I;is re P lacement e " conforms repatr or replacement to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/'A Certificate of Authorization No. N/'A N/'A Exp t stion Date Signed 8/cc/l ~As j 5~

or Owner's Designee. Title v'wner Date CERTIFICATE OF INSERVICE INSPEC )N I. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and Ihe State or Province of Dade County, Florida and employed by Arkwri ht Mutual Insurance Com an of Norwood, MA.

have inspected the components described in this Owner's Report during theperio to May 15. 1993 , and state that to the test vf my knowledge and belief, the Owner has perfortned examinations and taken corrective measures c.escribed in this Owner's Report in accordance with the requirements of ASME Code.Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied. concerning the examinations and corrective measures described in this Owners Report. Furthermore neither the inspector nor his employer shall be liable in any manner fol anypersonal injury or property or connected with the inspection.

'ctory Mutual Engineering Assoc Commissions NB 8230 N I Inspect r's Signature Nati*tat Board. Stale. Provtnce, and I:ndorsements

Page 1 of 2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI FLORIDA POWER & LIGHT May 19 1993 D I ~

Nellie P.O. BOX 029100, MIAMI, FL 33102 Sheet 1 of Address TURKEY POINT Unit Name P.O. BOX 3088. FLORIDA CITY, FL 33034 Siemens /'Ots B92691-01146 Address Repafr Organization P.O. No.. Job No. etc.

3 W<<k Performed FLORIDA POWER & LIGHT N/'A b Type Code Symbol Stamp Name Authorization No. N/'A P.O. BOX 3088. FLORIDA CITY, FL 33034 N/'A Expiration Date Address

4. Identification of Syste Waste Disposal Quality Group A
5. (a) Applicable Construction Code ANSI 831.1 1955 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980, Edition, Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components ASME Name of Name of Manufacturer National Other Repaired, Code Board Year Stamped Component Manufacturer Serial No. Identification Built Replaced, No. or Replacement (Yes or No)

Mech. Snubber PSA N/'A N/'A 4-1100 N/'A Replaced

7. Description of Work Replaced load pin,
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other Pressure psl Test Temp Degree's T NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/'2 in.

X 11 in., (2) information in items 1 through 6 on this report is included on each sheet and (3) each sheet is

~

numbered and the number of sheets is recorded at the top o( this form 93-024-4

FORM NIS 2 (Back)

9. Remarks Original Load Pin damaged.

Applicable Manufacturer's Dola Repotts to be attached CERTIFICATE OF COMPLIANCE We certify that the statements mode in the report are correct and this P " conforms repair or replacement to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization Nr'A N/'A

o. Expiration Date Signed Dote 19 Owner or Owner's Designee. title CERTIFICATE OF INSERVICE INSPECTION I. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade County. Florida and employed by Arkwri ht Mutual Insurance Com an of Norwood, MA.

have inspected the components described in this Owner's Report during theperio to May 5, 1993 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code.Section XI.

By signing this cerlificate neither the inspector nor his employer makes any warranty. expressed or I

implied. concerning the examinations and corrective measures described in this Owners Report. Furthermore neither the inspector nor his employer shall be liable in any manner for anypersonal injury or property damage or a loss of any kind, rising from or connected with the inspection.

Inspector's Sltlnature

~p-Commissions Factory Mutual Engineering Assoc.

NB 8230 N I ttatlonat Board. Slate. ProvInce. and Endorsements 0

Page 1 of 2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI FLORIDA POWER & LIGHT Ma y 1 9, 1 993 D a Ie Name P.O. BOX 029100, MIAMI, FL 33102 Sheet 1 of Address TURKEY POINT

2. Plant Unit Name P.O. BOX 3088. FLORIDA CITY, FL 33034 Address Siemens / POrs 892691-01146 Repair Organizalion P.O. No.. Job No. elo.

3 Work Pef formed b FLORIDA POWER & LIGHT N/'A Type Code Symbol Stamp Name Authorization No. N/'A P.O. BOX 3088. FLORIDA CITY, FL 33034 N/'A Expiration Date Address

4. Identification of Syste Feedwater Quality Group 8
5. (a) Applicable Construction Code ANSI B31.1 1955 Edition, N/A Addenda,, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980. Edition, Winter 1981 Addenda 6: Identification of Components Repaired or Replaced and Replacement Components ASME Name of Name of Manufacturer National Other Code Component Manufacturer Serial No. Board Replaced. Stamped Identification Built (Yes or No. or Replacement No)

Mech. Snubber PSA 182 N/'A 4-1035 N/'A Replaced No Mech. Snubber PSA 11439 N/'A '-1035 N/'A Replacement No

7. Description of Work Replaced PSA-10 Mechanical Snubber at tag location 4-1035.
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other Pressure psi Tesi Temp Degree's r NOTE: Supplemental sheets in form of lists. sketches, or drawings may be used. provided (1) size is 8 1/2 in.

~

X 11 in. (2) information in items

~ 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form 93-025-4

FORM NIS-2 (Back)

Replaced Snubber with previously tested spare serial st 11439.

9. Remarks Appttcabfe Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this re p lacement e conforms repair or replacemenl to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/'A Certificate of Authorization N/'A NINA o Expiration Date Signed Owner or Owner's Designee. tele et CERTIFICATE OF INSERVICE INSPECTION I. the undersigned. holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade County, Florida and employed by Arkwri ht Mutual Insurance Compan of Norwood. MA.

have inspected the components described in this Owner s Report during theperio M'y 1,

'a 1993 to May 12, 1993 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code.Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore neither the inspector nor his employer shall be liable in any manner for anypersonal injury or property damage or a loss of any kind arising from or connected with the inspection.

Factory Mutual Engineering Assoc Commissions NB 8230 N I National Board. Slate. Province. and Bndorsements

Page 1 of 2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI FLORIDA POWER & LIGHT May 19, 1993 Name P.O. BOX 029100, MIAMI. FL 33102 Sheet t of Address TURKEY POINT

2. Plant Unit Name P.O. BOX 3088, FLORIDA CITY, FL 33034 Siemens r'Oss 892691-01146 Address Repair Orpanizanon P.O. Ho.. Job Ho. elo.

Work Performed b FLORIDA POWER & LIGHT N/A Type Cod e Symbo I Slam p Hams Authorization No. NJ'A P.O. BOX 3088. FLORIDA CITY, FL 33034 N/'A Expiration Date Address

4. Identification of Syste Main Steam Quality'roup 8
5. (a) Applicable Construction Code ANSI 831 1 1955 Edition, Ni A Addenda, Ni'A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980, Edition, Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components ASME Name of Name of Manufacturer National Other Repaired, Code Board Year Stamped Component Manufacturer Sel'lal No ~ Identification Replaced,'r (yes or No. Replacement No)

Mech. Snubber PSA 4589 NJ'A 4-1039 N/'A Replaced No Mech. Snubber PSA 6998 N/'A 4-1039 Nf'A Replacement No

7. Description of Work Replaced PSA-35 Mechanical Snubber at tag location 4-1039.
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other Pressure psl Test Temp Degree's F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used. provided (1) size is 8 1/'2 in.

X 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded af the top of this form 93-026-4

Page 2 of 2 FORM NIS 2 (Back)

Replaced Snubber with previously tested spare serial st 6998.

9. Remarks Applicable Manutacturer's Data Reports to be attached CERTIFICATE OF COMPLiANCE We certify that the statements made in the reporl are correct and this P m " conforms repair or replacemenl to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/'A Certificate of Authorizati No. N/A N/A Expiration Date Signed Owner or Owner's Designee, TRle Date 5/~/, 19 H CERTIFICATE Of INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade County, florida and.employed by Arkwri ht Mutual Insurance Com an of Norwood. MA.

have inspected the components described in this Owner's Report during theperio to Ma 12, 1993 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance wilh the requirements of ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty. expressed or implied. concerning the examinations and corrective measures described in this Owners Report. Furthermore neither the inspector nor his employer shall be liable in any manner for anypersonal injury or property damage or a loss of any kind arising from or connected with the inspection.

factory Mutual Engineering Assoc Commissions NB 8230 N I I ector's Slgnalure Notional Board. Slat ~, Province, and Endorsements 19~&

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI FLORIDA POWER & LIGHT" May 19 ~ 1993 Name P.O. BOX 029100. MIAMI, FL 33102 Sheet of Address TURKEY POINT

2. Plant Unit Name P.O. BOX 3088, FLORIDA CITY, FL 33034 Siemens f'Ots 892691-01146 Address Repotr Organization P.O. No.. Job No. elc.

3 Work Per formed b FLORIDA POWER &. LIGHT Nf'A Type Code Symbol Stamp Name Authorization No. NJ'A P.O. BOX 3088, FLORIDA'ITY, FL 33034 NI/A Expiration Date Address

4. Identification of Syste Reactor Coolant Quality Group A
5. (a) Applicable Construction Code ANSI B31 1 1955 Edition. N~A Addenda, N~A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980, Edition. Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components ASME Name of Name of Manufacturer National Other "~ Repaired, Code Board ear Stamped Component Manufacturer Serial No. Identification Replaced, No. or Replacement (Yes or No)

Mech. Snubber PSA 16253 N/'A 4-1054 Nf'A Replaced No Mech. Snubber PSA 15718 NJ'A 4-1054 N/A Replacement No

7. Description of Work Replaced PSA-10 Mechanical Snubber at tag location 4-1054.
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure 'ther Pressure psl Test Temp Degree's F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be, used, provided (1) size is 8 1f'2 in.

X 11 in.. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of. this form 93-027-'4

Page 2 of 2 FORM NIS-2 (Back)

Replaced Snubber with p'reviously tested spare serial tt 15718 per CRtt 93-364.

9. Remarks Applicable Manufacturer's Oata Reports lo be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this p m " conforms repair or replacement to the rules of the ASME Code.Section XI.

Type Code Symbol Stamp N/A Nj'A N/'A Certificate of Authorizatio No. Expiration Date Signed ~ 19 ~9 Owner or Owner's Designee. Btt ~

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned. holding a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the State or Province of Dade County, Florida and employed by Arkwri ht Mutual Insurance Com an of Norwood. MA.

have inspected the components described in this Owner's Report during theperio Ma 1, 1993 to May 5. 1993 . and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code.Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied. concerning the examinations and corrective measures described in this Owners Report. Furthermore neither the inspector nor his employer shall be liable in any manner for anypersonal injury or property damage or a loss of any kind arising from or connected with the inspection.

Factory Mutual Engineering Assoc.

Commissions NB 8230 N I InspeZtor's Signature ttattonat Board, State. Province. and Bndorsemenls

Page I of 2 FORlvl NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI FLORIDA POWER & LIGHT May 19, 1993 Name P,O. BOX 029100, MIAMI, FL 33102 Sheet 1 of Address TURKEY POINT

2. Plant Unit Name P.O. BOX 3088, FLORIDA CITY. FL 33034 Siemens /'Ott B92691-01146 Address Repair Oreantzalfon P.O. No.. Job No. etc.
3. Work Perfortned b FLORIDA POWER & LIGHT N/A Type Code Symbol Stamp Nome Authorization No. N/A P.O. BOX 3088, FLORIDA CITY, FL 33034 N/A Expiration Date Address
4. Identification of Syste Reactor Coolant Quality Group A
5. (a) Applicable Construction Code ANSI 831 1 1955 Edition. N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980, Edition, Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components ASME Name of Name of Manufacturer National Other Repaired, Code Board Year Stamped Component Manufacturer Serial No. Identification Built Replaced.

No. or Replacement (Yes or No)

Mech. Snubber PSA 11110 N/A 4-1055 N/A Replaced Mech. Snubber PSA 7782 N/A 4-1055 N/A Replacement No

7. Description of Work Replaced PSA-10 Mechanical Snubber at tag location 4-1055.
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other Pressure p st Test Temp Degree' F NOTE: Supplemental sheets in form, of lists. sketches. or drawings may be used. provided (1) size is 8 1/2 in.

X 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form 93-028-4

Page 2 of 2 FORM NIS-2 (Back)

9. Remarks Replaced Snubber with previously tested spare serial ss 7782 per CRIs93-326.

Applicable Manufacturer's Oala Reports lo be attached CERTIFICATE OF COMPLIANCE We certify }hat the statements made In the repo~ are correct and this "P"" '"'onforms repair or replocernent to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N j'A N j'A Certificate of Authorization Expiration Date Signed Date 19 53 Owner or Owner's Designee. Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade County, Florida and employed by Arkwri ht Mutual Insurance Compan of Norwood, MA.

have inspected the components described in this Owner's Report during theperio to May 5, 1993 . and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code,Section XI.

By signing this cerlificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore neither the inspector nor his employer shall be liable in any manner for anypersonal injury or property damage or a loss of any kind arising from or connected with the inspection.

Factory Mutual Engineering Assoc Commissions NB 8230 N I inspector's Signature ttattonat Board. Stale, Province, and EndorseInents

Page 1 of 2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI FLORIDA POWER & LIGHT May 20. 1993 Date Name P.O. BOX 029100, MIAMI, FL 33102 Sheet 1 of Address TURKEY POINT

2. Plant Unit Name P.O. BOX 3088, FLORIDA CITY, FL 33034 Woss 93011906 PWOss 6172 Address Repair Organlzauon P.O. No.. Job No. elc.

W<<k Performed FLORIDA POWER & LIGHT N/'A 3 b Type Code Symbol Stamp Name Authorization No. NI A P.O. BOX 3088, F'LORIDA CITY. FL 33034 NI'A Expiration Date Address

4. Identification of Syste Main Steam Quality Group B
5. (a) Applicable Construction Code ANSI 831 1 1955 Edition. N/A Addenda. N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980. Edition. Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components ASME Name of Name of Manu fa ct urer National Other Repaired, Code Year Stamped Component Manufacturer Serial No. Board Identification Bu.,lt Replaced.

No. or Replacement (Yes or No)

Safety Valve Consolidated N/'A N//A RV 1400 N/'A Replaced No

7. Description of Work Replaced Bon'net studs and nuts.
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other Pressure psi Teel Temp Degree's r NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/'2 in.

X 11 in., (2) information in items 1 through 6 on this report is included on each sheet. and (3) each sheet is numbered and the number of sheets is recorded at the top of this form 93-029-4

Page 2 of 2 FORM NIS-2 (Back)

Replaced pressure retaining studs and nuts. no welding performed.

9. Remarks Applicable Manufacturer's Data Reports lo be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this re P la cern ent" conforms repair or replacement to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp Nf'A W'A N/'A Certificate of Authorizati No. Expiration Date Signe Owner or Owner's Des pnee. Title

" ~/ . 197~

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade County, Florida and employed by Arkwri ht Mutual Insurance Corn an o( Norwood. MA.

have inspected the components described in this Owner's Report during theperio to May 20, 1993 , and state that to the best of my knowledge and belief.

the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code.Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed 'or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore neither the inspector nor his employer shall be liable in any manner for anypersonal injury or property damage or a loss of any kind ar'ng from or connected with the inspection.

Factory Mutual Engineering Assoc Commissions NB 8230 N I In clor's Signature ttationot Board. Slot ~ . Province. and Endorsernenis 19 FP

Page I of 2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI FLORIDA POWER & LIGHT May 20 1993 D I ~

Hame P.O. BOX 029100, MIAMI FL 33102

~

Sheet 1 of Address TURKEY POINT

2. Plant Unit Hame P.O. BOX 3088, FLORIDA CITY, FL 33034 WOss 92031543 PWOss 0259 Address Repatr Organlzauon P.O. Ho.. Job Ho. elc.

3 Work Performed b FLORIDA POWER 8c LIGHT Type Code Symbol Stamp N/'A Hatne Authorization No. N/'A P.O. BOX 3088, FLORIDA CITY, FL 33034 N/'A Expiration Date Address

4. Identification of Sysle Main Steam Quality Group 8
5. (a) Applicable Construction Code ANSI B31.1 19 55 Edition. N/'A Addenda. N/'A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980, Edition, Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components ASME Name of Name of Manufacturer National Other Repaired. Code Board Year Stamped Component Manufacturer Serial No. Identification Built Replaced.

No. or Replacement (Yes or No)

Safety Valve Consolidated N/'A N/'A RV 1401 N/'A Replaced No

7. Description of Work Replaced Bonnet studs and nuts.
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other Pressure psl Test Temp Degree' r NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/'2 in.

X ll in.. (2) information in items 1 through 6 on this report is included on each sheet. and (3) each sheet is numbered and the number of sheets is recorded at the top of this form 93-030-4

FORM HIS 2 (Back)

Replaced pressure retaining studs and nuts, no welding performed.

9. Remarks Applicable Manufacturer's Bala Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this P m " conforms repair or replacement to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/rA Ni'A N/'A Certificate of Authorizati No. Expiration Date Signed Date Owner or Owner's Oestgnee, Title CERTIFICATE OF INSERVICE INSPECTION I~ the undersigned. holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade County, f'lorida and employed by Arkwri ht Mutual Insurance Com an of Norwood, MA.

have inspected the components described In this Owner s Report during theperto "'""'y '

'o May 20. 1993 , and state that to the best of my kno'wledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code.Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Reporl. f'urthermore neither the inspector nor his employer shall be liable in any manner for anypersonal injury or property damage or a loss of any kind arising from or connected with the inspection.

f'actory Mutual Engineering Assoc Commissions NB 8230 N I I peclor's Signature ttattonat Board, Stale, Proetnce. and Endorsements

Page I of 2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI FLORIDA POWER & LIGHT May 20 1993 0 f ~

Name P.O. BOX 029100, MIAMI, FL 33102 Sheet 1 of Address TURKEY POINT

2. Plant Unit Name P.O. BOX 3088. FLORIDA CITY, FL 33034 WOss 92031544 PWOss 0261 Address Repair Organizanon P.O. No.. Job No. ~ ic.

3 'Work Per formed FLORIDA POWER & LIGHT N/'A b Type Code Symbol Stamp Name Authorization No. N/'A P.O. BOX 3088. FLORIDA CITY, FL 33034 N/'A Expiration Date Address

4. Identification of Syste Main Steam Quality Group B
5. (a) Applicable Construction Code ANSI B31 1 1955 Edition. N/'A Addenda, N/'A Code Case (b) Applicable Edition of Section XI Utilized (or Repairs or Replacements 1980, Edition, Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components ASME Name of Name of Manufacturer National Other Repaired. Code Board Year Component Manufacturer Replaced, Stamped Serial No. Identification Built (Yes or No. or Replacement No)

Safety Valve Consolidated N/'A N/'A RV-4-1402 N/'A Replaced

7. Description of Work Replaced Bonnet studs and nuts.
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other r

Pressure psl Test Temp Degree's r NOTE: Supplemental sheets in form of lists. sketches, or drawings may be used, provided (1) size is 8 I/2 in.

X 11 in.. (2) information in items I through 6 ori this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form 93-031-4

Page 2 of 2 FORM NIS 2 (Back)

9. Remarks Replaced pressure retaining studs and nuts, no welding performed.

Applicable Manufacturer's Oala Reports lo be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this re P lacement" conforms repair or replacement to the rules of the ASME Code.Section XI.

Type Code Symbol Stamp NJ'A Cerlificate of Authorizatto No. Nv A N/'A Expiration Date Signed Date . 19 9~

Owner or Owner's Designee. Tttte CERTIFICATE OF INSERVICE INSPECTION I. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade County. Florida and employed by Arkwri ht Mutual Insurance Corn an of Norwood, MA.

have Inspected the components described In this Owner s Repoa during theperlo to May 20, 1993 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code.Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied. concerning the examinations and corrective measures described in this Owners Report. Furthermore neither the inspector nor his employer shall be liable in any manner for anypersonal injury or property damage or a loss of any kind ar'sing from or connected with the inspection.

Factory Mutual Engineering Assoc.

Commissions NB 8230 N I Ins e or's Signature National Board. Slate. Province. and fndorsements

Page I of 2 FORM NIS 2 OWNER'S REPORT FOR, REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI FLORIDA POWER & LIGHT May 20, 1993 Name P.O. BOX 029100, MIAMI, FL 33102 Sheet 1 of Address TURKEY POINT

2. Plant Unit Name P.O. BOX 3088, FLORIDA CITY, FL 33034 Woss 93008534 PWOQ 5606 Address Repair Organizanon P.O. No., Job No. ~ Ic.

'Work Performed b FLORIDA POWER & LIGHT N/'A 3 Type Code Symbol Stamp Name Authorization No. N/A P.O. BOX 3088. FLORIDA CITY, FL 33034 N/'A Expiration Date Address

4. Identification of Syste Main Steam Quality Group B
5. (a) Applicable Construction Code ANSI B31 1 1955 Edition. N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980, Edition, Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components ASME Name of Name of Manufacturer Notional Other Repaired, Code Year Stomped Component Manufacturer Serial No. Board Identification Replaced.

Built (Yos or No. or Replacement No)

Safety Valve Consolidated N/A N/'A RV-4-14 10 N/IA Replaced No

7. Description of Work Replaced Bonnet studs and nuts.
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other Pressure psl Test Temp Degree's r NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/'2 in.

X 11 in., (2) information in items 1 through 6 on this report is included on each sheet. and (3) each sheet is numbered and the number of sheets is recorded at the top of this form 93-032-4

Page 2 of 2 FORM NIS-2 (Back)

9. Remarks Replaced pressure retaining studs and nuts, no welding performed.

Appltcabfe Manufacturer's Outa Reports lo be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the reporl are correct and this P em " conforms repair or replacement to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authoriza 'on No. N/A Expiration Date Signed Owner or Owner's Oestgnee. Title Date S l+W, 19 CERTIFICATE OF INSERVICE INSPECT(ON I~ the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade County, Florida and employed by Arkwri ht Mutual Insurance Com an of Norwood. MA.

have inspected the components described in this Owner's Reporl during iheperio to May 20, 1993 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code.Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty. expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore neither the inspector nor his employer shall be liable in any manner for anypersonal injury or property damage or a loss of any kind arising from or corlnected with the inspection.

Factory Mutual Engineering Assoc Commissions NB 8230 N I tnspeclor's Signature ttattonat Board. Stale, Province. and Bndorsemenls

Page of 2 FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS 1

As Required by the Provisions of the ASME Code Section XI FLORIDA POWER & LIGHT May 20, 1993 Name P.O. BOX 029100, MIAMI, FL 33102 Sheet 1 of Address TURKEY POINT Unit Name P.O. BOX 3088. FLORIDA CITY, FL 33034 Woss 92032703 PWOss 0248 Address Repair Organtzauon P.O. No.. Job No. etc.

3. Work Performed b FLORIDA POWER & LIGHT N/A Type Code Symbol Stamp Name Authorization No. N/A P.O. BOX 3088, FLORIDA CITY. FL 33034 N/A Expiralion Date Address
4. Identification of Syste Main Steam Quality Group B
5. (a) Applicable Construction Code ANSI B31.1 1955 Edition, N/A Addenda. N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980 Edition, Winter 1981 Addenda

~

6. Identification of Components Repaired or Replaced and Replacement Components ~

ASME Name of Name of Manufacturer National Other Repaired, Code Board ear Stomped Component Manufacturer Serial No. Identification Built Replaced.

No. or Replacement (Yes or No)

Safety Valve Consolidated N/A N/'A RV 14 11 N/A Replaced

7. Description of Work Replaced Bonnet studs and nuts.
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other ~ H Pressure ps l Test Temp Degree' F NOTE: Supplemental sheets in form of lists. sketches. or drawings may be used. provided (1) size is 8 1/2 in.

X 11 in., (2) information in items 1 through 6 on this report is included on each sheet. and (3) each sheet is numbered and the number of sheets is recorded at the top of this form 93-033-4

Page 2 of 2 FORM NIS 2 (Back)

9. Remarks Replaced pressure retaining studs and nuts, no welding performed.

Applicable Manufaclurer's Bala Reports lo be altached II CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this P " conforms repair or replacemenl to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp NvjA Certificate of Authorization o. NvjA N j'A Expiration Date Signed 19 RF Owner or Owner's Designee. I1lle CERTIFICATE OF INSERVICE INSPECTION I. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade County, Florida and employed by Arkwri ht Mutual Insurance Com an of Norwood. MA.

have inspected the components described in this Owner's Report during theperio to May 20. 1993 , and state that to the best of my knowledge and belief, the Owner has performed examinations and token corrective measures described in this Owner's Report in accordance with the requirements of ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty. expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore neither the inspector nor his employer shall be liable in any manner for anypersonal injury or property damage or a loss of any kind arising from or connected with the inspection.

Factory Mutual Engineering Assoc Commissions NB 8230 N I In clor's Signalure IIallonal Board, Slate. Province. and Bndorsemenls

Page 1 of 2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI FLORIDA POWER & LIGHT May 20. 1993 Hams P.O. BOX 029100, MIAMI, FL 33102 Sheet 1 of Address TURKEY POINT

2. Plant Unit Hams P.O. BOX 3088, FLORIDA CITY, FL 33034 WOIs 93012824 PWOH 6401 Address RepaIr OrganIzalioa P.O. Ho., Job Ho. ~ Ic.
3. Work Performed b FLORIDA POWER & LIGHT N/'A Type Code Symbol Stamp Hams Authorization No. N/'A P.O. BOX 3088, FLORIDA CITY, FL 33034 N/A Expiration Date Address
4. Identification of Syste Main Steam Quality Group 8
5. (a) Applicable Construction Code ANSI 831 1 1955 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980. Edition, Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components ASME Name of Name of Manufacturer National Other Repaired, Code Board Year Stamped Component Manufacturer Serial No. Identification Buill Replaced, No. or Replacement (Yes or No)

Safety Valve Consolidated N/A N/'A RV 14 12 N/'A Replaced No

7. Description of Work Replaced Bonnet studs and nuts.
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other Pressure p st Test Temp Degree' r NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/'2 in.

X 11 in., (2) information in items 1 through 6 on this report is included on each sheet. and (3) each sheet is numbered and the number of sheets is recorded at the top of this form 93-034-4

Page 2 of 2 FORM NIS 2 (Back)

9. Remarks Replaced pressure retaining studs and nuts, no welding performed.

Applicable Manutacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the reporl are correct and this P em " conforins repair or replacement to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp Ni'A Cerlificate of Authorizati Signed No. N/A Owner or Owner's Designs . Till~

~/.

Expiration Date Date N/'A 9

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade County. Florida and employed by Arkwri ht Mutual Insurance Com an of Norwood, MA.

have Inspected the components described in this Owner s Repoa during theperio M'y to May 20. 1993 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requireinents of ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or iinplied, concerning the examinations and corrective measures described in this Owners Report. Furthermore neither the inspector nor his employer shall be liable in any manner for anypersonal injury or property damage or a loss of any kind arising from or connected with the inspection.

Factory Mutual Engineering Assoc.

Commissions NB 8230 N I I pector's Signature National Board. Slate. Province. and Endorsements

Page 1 of 2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI FLORIDA POWER & LIGHT May 20, 1993 D f Name P.O. BOX 029100. MIAMI, FL 33102 Sheet 1 of Address TURKEY POINT

2. Plant Unit Name P.O. BOX 3088, FLORIDA CITY, FL 33034 Woss 92031546 Pwoss 0256 Address Repair Organizanan P.O. No. Job No.

~ ~ Ic.

3 Wo,k Performed FLORIDA POWER & LIGHT N/'A b Type Code Symbol Stamp Name Authorization No. N/'A P.O. BOX 3088, FLORIDA CITY, FL 33034 N/'A Expiration Dote Address

4. Identification of Syste Main Steam Qualify Group B
5. (a) Applicable Construction Code ANSI 831 1 1955 Edition. N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980, Edition, Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components ASME Name of Name of Manufacturer National Other Repaired, Code Year Component Manufacturer Serial No. Board Identification Replaced, Stomped Built (Yes or No. or Replacement No)

Safety Valve Consolidated N/'A N/'A RV 14 13 N/'A Replaced No

7. Description of Work Replaced Bonnet studs and nuts.
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other Degree' r 1

Pressure psl Teer Temp NOTE: Supplemental sheets in form of lisfs, sketches, or drawings may be used. provided (1) size is 8 1/2 in.

X 11 in.. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form 93-035-4

Page 2 of 2 FORM NIS-2 (Back)

9. Remarks Replaced pressure retaining studs and nuts, no welding performed.

Applicable Manufacturer's Bala Reports lo be attached CERTIFICATE OF COMPLIANCE 4

We certify that the stalemenls made in the report are collect and this re P lacement" conforms repair or replacement to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/'A Certificate of Authoriz N/'A N/'A on No. Expiration Date Signed Date $

- PP 1g 53 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade County, florida and employed by Arkwri ht Mutual Insurance Compan of Norwood, MA.

have inspected the components described in this Owner's Report during theperio to May 20, 1993 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code.Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Reporl. Furthermore neither the inspector nor his employer shall be liable in any manner for anypersonal injury or property damage or a loss of any kind arising from or connected with the inspection.

I peclor's Stgnalure Commissions Factory Mutual Engineering Assoc.

NB 8230 N I ttattonat Board, Stale. Proetnce. and I:ndorsements 0

19~~

Page 1 of 2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI FLORIDA POWER 8( LIGHT May 20. 1993 Name P.O. BOX 029100, MIAMI FL 33102

~

Sheet 1 of Address TURKEY POINT

2. Plant Unit Name P.O. BOX 3088, FLORIDA CITY, FL 33034 Woss 93012821 Pwoss 6404 Address Repair Orpanlzation P.O. No., Job No. ele.

3 'Work Pef formed b FLORIDA POWER R LIGHT Type Code Symbol Stamp N/'A Name Authorization No. N/'A P.O. BOX 3088, FLORIDA CITY, FL 33034 N/'A Expiration Dote Address

4. Identification of Syste Main Steam Quality Group 8
5. (a) Applicable Construction Code ANSI 831 1 1955 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements ]980Edition, Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components ASME Name of Name of Manufacturer Notional 0!her Repaired, Code Board Year Stomped Component Manufacturer Serial No. Identification Built Replaced.

No. or Replacement (Yes or No)

Safety Valve Consolidated N/'A N/'A RV-4-1403 N/'A Replaced No

7. Description of Work Replaced Bonnet studs and nuts.
8. Tests Conducted: Hydrostatic Pneumatic 'Nominal Operating Pressure Other Pressure psl Test Temp Degree's r NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used. provided (1) size is 8 1/2 in.

X 11 in., (2) information in items 1 through 6 on this report is included on each sheet. and (3) each sheet is numbered and the number of sheets is recorded at the top of this form 93-036-4

Page 2 of 2 FORM HIS-2 (Back)

Replaced pressure retaining studs and nuts, no welding performed.

Appttcabte Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this P em " conforms repair or replacement to the rules of the ASME Code.Section XI.

Type Code Symbol Stamp N/A Certificate of Authorizati No. N/A N/'A Expiration Date Signed 19 9J Owner or Owner's Designee. Title CERTIFICATE OF INSERVICE INSPECTION I. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade County. Florida and employed by Arkwri ht Mutual Insurance Com an Norwood. MA.

have Inspected the components described in this Owner s Report during theperlo of M'y '

to May 20. 1993 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or

. implied, concerning the examinations and corrective measures described in this Owners Reporl. Furthermore neither the inspector nor his employer shall be liable in any manner for anypersonal injury or property damage or a loss of any kind arising from or connected with the inspection.

Factory Mutual Engineering Assoc.

Commissions NB 8230 N I Ins e or's Signature ttattonat Board. Slate. Province. ond Bndorsemenls

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI FLORIDA POWER & LIGHT May 20. 1993 Hams P.O. BOX 029100, MIAMI, FL 33102 Sheet 1 of Address TURKEY POINT

2. Plant Unit Name P.O. BOX 3088, FLORIDA CITY, FL 33034 WOss 93012855 PWOss 6412 Address Repair Organizanon P.O. Ho.. Job Ho. ~ Ic.

3 Work Performed b FLORIDA POWER & LIGHT N/A Type Code Symbol Stamp Hame Authorization No. N/'A P.O. BOX 3088, FLORIDA CITY, FL 33034 N/'A Expiration Date Address

4. Identification of Syste Main Steam Quality Group 8
5. (a) Applicable Construction Code ANSI 831 I 1955 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980, Edition, Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components ASME Name of Nome of Manufacturer National Repaired. Code Other Year Component Manufacturer Serial No. Board Replaced. Stamped Identification Built (Yes or No. or Replacement Na)

Safety Valve Consolidated N/'A N/'A RV-4-1405 N/'A Replaced No

7. Description of Work Replaced Bonnet studs and nuts.
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other Pressure psl Test Temp Degree's F NOTE: Supplemental sheets in form of lists. sketches, or drawings may be used, provided (1) size is 8 1/'2 in.

X 11 in.. (2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form 93-037-4

Page 2 of 2 FORM NIS 2 (Back)

9. Remarks Replaced pressure retaining studs and nuts, no welding performed.

Applicable Manutocturer's Bala Reports lo be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this P m " conforms repair or replacement to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp W'A Nl'A N/'A Certificate of Authorizati No. Expiration Date Signed Date Owner or Owner's Oestgnee. Tttl~

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade County. Florida and employed by Arkwri ht Mutual lrisurance Com an of Norwood. MA.

have inspected the components described in this Owner's Report during theperio to Ma 20, 1993 , and state that to the best of my knowledge and belief.

the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code,Section XI.

By signing this cerlificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore neither the inspector nor his employer shall be liable in any manner for anypersonal injury or property damage or a loss of any kind arising from or connected with the inspection.

Factory Mutual Engineering Assoc Commissions NB 8230 N I nspeclor's Signature ttational Board, Slat ~, Province. and Bndorsemenls

Page 1 of 2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI FLORIDA POWER Ik LIGHT Igtay 20. 1993 Name P.O. BOX 029100, MIAMI, FL 33102 Sheet 1 of Address TURKEY POINT

2. Plant Unit Home P.O. BOX 3088, FLORIDA CITY, FL 33034 Wott 92042443 PWOts 1757 Address Repair Oreantzatfon P.O. Ho., Job Ho. eic.

Work Performed b LORIDA POWER Ec LIGHT Type Code Symbol Stamp N/'A Hams Authorization No. N/A P.O. BOX 3088, FLORIDA CITY, FL 33034 N/A Expiration Date Address

4. Identification of Syste Main Steam Quality Group B
5. (a) Applicable Construction Code ANSI 831 1 1955 Edition. NiA Addenda. NiA Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980, Edition, Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components ASME Name of Name of Manufacturer National Other Repaired, Code Board Year Stomped Component Manufacturer Serial No. Identification Built Replaced.

No. or Replacement (Yes or No)

Safety Valve Consolidated Nf'A NI'A RV-4-1406 NI/A Replaced No

7. Descriptiorl of Work Replaced Bonnet studs and nuts.
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other Pressure psl Test Temp Degree's r NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used. provided (1) size is 8 1i2 in.

X 11 in.. (2) information in items 1 through 6 on this report is included on each sheet. and (3) each sheet is numbered and the number of sheets is recorded at the top of this form 93-038-4

Page 2 of 2 FORM NIS-2 (Bacjc.')

9. Remarks Replaced pressure retaining studs and nuts. no welding performed.

Applicable Manufacturer's Data Reports lo be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this P em " conforms repatr or replacement to the rules of the ASME Code.Section XI.

Type Code Symbol Stamp &'A Certificate of Authorizatio N/'A N j'A

o. Expiration Date Signed Date S / ercg, 19 F3 Owner or Owner's Oeslg ee. Till~

CERTIFICATE OF INSERVICE INSPECTION I. the undersigned. holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade County, Florida and employed by Arkwri ht Mutual Insurance Com an of Norwood, MA.

have inspected the components described in this Owner s Report during theperio 'Pte to May 20, 1993 . and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code,Section XI.

By signing this cerlificate neither the inspector nor his employer makes any warranty. expressed or implied. concerning the examinations and corrective measures described in this Owners Report. Furthermore neither the inspector nor his employer shall be liable in any manner for anypersonal injury or property damage or a loss of any king arising from or connected with the inspection.

Factory Mutual Engineering Assoc Commissions NB 8250 N I nspeclor's Signature National Board. Slate. Province. and Endorsements

Page 1 of 2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI FLORIDA POWER & LIGHT May 20. 1993 Date Name P.O. BOX 029100, MIAMI, FL 33102 Sheet 1 of Address TURKEY POINT

2. Plant Unit Name P.O. BOX 3088, FLORIDA CITY, FL 33034 WO¹ 93012822 PWO¹ 6402 Address Repair Organiza¹an P.O. Na., Job Na. ~ Ic.

Wok Performed b FLORIDA POWER & LIGHT N/'A Type Code Symbol Stamp Name Authorization No. Nj'A P.O. BOX 3088, FLORIDA CITY, FL 33034 Nf'A Expiration Date Address

4. Identification of Syste Main Steam Qualify Group B
5. (a) Applicable Construction Code ANSI B31 1 1955 Edition, N~A Addenda, N~A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980. Edition, Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components ASME Name of Name of Manufacturer National Other Repaired. Code Board Year Stomped Component Manufacturer Serial No. Identification Built Replaced, No. or Replacement (Yes or No)

Safety Valve Consolidated NP'A Nj'A RV 1408 N/A Replaced No

7. Description of Work Replaced Bonnet studs and nuts.

tr

8. Tests Conducted Hydrostatic Pneumatic Nominal Operating Pressure Other T

Pressure Test Temp tgegree's r NOTE: Supplemental sheets in form of lists, sketches. or drawings may be used, provided (1) size is 8 1/2 in.

X 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form 93-039-4

Page 2 of 2 FORM NIS-2 (Back)

9. Remarks Replaced pressure retaining studs and nuts, no welding performed.

Applicable Manufacturer's Oala Reports lo be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this p " conforms repair or replacement to the rules of the ASME Code.Section XI.

Type Code Symbol Stamp N/'A Cerlificate of Authori ation N/'A N/'A Expiration Date Signed Date .19 5M Owner or Owner's Designee. ille CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade County. Florida and employed by Arkwri ht Mutual Insurance Com an Norwood. MA.

have inspected the components described in this Owner s Report during theperlo of M'y '

to May 20. 1993 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty. expressed or implied. concerning the examinations and corrective measures described in this Owners Report. Furthermore neither the inspector nor his employer shall be liable in any manner for anypersonal injury or property damage or a loss of any kind arising from or connected with the inspection.

Factory Mutual Engineering Assoc Commissions NB 8230 N I I eclor's Signature National Board. Slate. Province. and Endorsements

Page 1 of 2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI FLORIDA POWER 8( LIGHT May 20, 1993 Nome P.O. BOX 029100, MIAMI, FL 33102 Sheet 1 of Address TURKEY POINT

2. Plant Unit Name P.O. BOX 3088, FLORIDA CITY. FL 33034 Woss 92031545 PWOss 0263 Atjdpess Repair Organization P.O. No., Job No. ~ Ic.

Work Performed b FLORIDA POWER fI( LIGHT N/'A Type Code Symbol Stamp Name Authorization No. N/'A P.O. BOX 3088, FLORIDA CITY, FL 33034 N/'A Expiration Date Address

4. Identification of Syste Main Steam Quality Group B
5. (a) Applicable Construction Code ANSI B31 1 1955 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980, Edition, Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components ASME Name of Name of Manufacturer National Other Repaired. Code Year Stamped Component Manufacturer Serial No. Board Identification Replaced, Built (Yes or No. or Replacement No)

Safety Valve Consolidated N/'A N/A RV-4-1407 N//A Replaced No

7. Description of Work Replaced Bonnet studs and nuts.
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other Pressure PS I Test Temp Degree' p NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/'2 in.

X 11 in.. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form 93-040-4

FORM NIS 2 (Back)

Replaced pressure retaining studs and nuts. no welding performed.

9. Remarks Applicable Manufacturer's Oala Reports lo be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this p m " conforms repair or replacement to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization o.

N/'A N j'A Expiration Date Signed Owner or Owner's Destgnee. Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned. holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade County, Florida and employed by Arkwri ht Mutual Insurance Com an of Norwood, MA.

hove Inspected the components described In this Owner s Report during theperlo "'""'y to May 20, 1993 , and state that to the best of my knowledge and belie(,

the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore neither the inspector nor his employer shall be liable in any manner for anypersonal injury or property damage or a loss of any kin ar sing from or connected with the inspection.

Factory Mutual Engineering Assoc.

Commissions NB 8230 N I lns ctor's Signature National Board. Stale. Province. and Endorsements

Page I of 2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI FLORIDA POWER & LIGHT May 20. 1993 Name P.O. BOX 029100, MIAMI, FL 33102 Sheet 1 of Address TURKEY POINT

2. Plant Unit Name P.O. BOX 3088, FLORIDA CITY, FL 33034 Woss 91058614 Pwoss 2264 Address Repair Organtzatlon P.O. No. Job No. etc.

~

Work Pef formed b FLORIDA POWER & LIGHT N/A Type Code Symbol Stamp Name Authorization No. N/A P.O. BOX 3088, FLORIDA CITY, FL 33034 N/'A Expiration Date Address

4. Identification of Syste Chemical and Volume Control Quality Group B
5. (a) Applicable Construction Code ANSI B31 1 1955 Edition, N/A Addenda. N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980, Edition, Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components ASME Name of Name of Manufacturer National Other Repaired, Code Board Year Stamped Component Manufacturer Serial No. Identification Built Replaced.

No. or Replacement (Yes or No)

Relief Valve Crosby N/'A N/A RV-4-203 N/'A Replaced No

7. Description of Work Replaced two (2) bonnet studs and one (1) nut.
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other Pressure psl Teel Temp Degree's F NOTE: Supplemental sheets in form of lists, sketches. or drawings may be used. provided (1) size is 8 1/2 in.

X 11 in.. (2) information in items 1 through 6 on this report is included on each sheet. and (3) each sheet is numbered and the number of sheets is recorded at the top of this form 93-04 1-4

Page 2 of 2 FORM NIS-2 (Back)

Replaced pressure retaining bolting, no welding performed.

Applicabte Manutaclurer's Data Reports lo be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this P m conforms repair or replacement to the rules of the ASME Code.Section XI.

Type Code Symbol Stamp NJ'A Certificate of Authoriz ion No. N j'A N/'A Expiration Date Signed Date Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I. the undersigned, holding a valid commission issued by the Notional Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade County, Florida and employed by Arkwri ht Mutual Insurance Com an of Norwood, MA.

have inspected the components described in this Owner's Report during theperio to May 20, 1993 . and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore neither the inspector nor his erriployer shall be liable in any manner for anypersonal injury or property damage or a loss of any kind arising from or connected with the inspection.

Factory Mutual Engineering Assoc Commissions NB 8230 N I Inspector's Signature ttollonol Board. Slate. Province. ond Endorsemenls 944:

Page of 2 FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS 1

As Required by the Provisions of the ASME Code Section XI FLORIDA POWER & LIGHT May 21, 1993 Dale Name P.O. BOX 029100, MIAMI, FL 33102 Sheet 1 of Address TURKEY POINT

2. Plant Unit Name P.O. BOX 3088, FLORIDA CITY, FL 33034 Woss 92056784 PWOss 3451 Address Repair Organlzanon P.O. No. Job No. ele.

~

3 Work Performed b FLORIDA POWER & LIGHT Nss'A Type Code Symbol Stamp Name Authorization No. N/A P.O. BOX 3088, FLORIDA CITY, FL 33034 Nss'A Expiration Date Address

4. Identification of Syste Reactor Coolant S stem Qualify Group A
5. (a) Applicable Construction Code ANSI B31 1 1955 Edition, NiA Addenda. NiA Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980, Edition. Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components ASME Name of Name of Manufacturer National Other Repaired, Code Board Year Stamped Component Manufacturer Serial No. Identification Built Replaced, No. or Replacement (Yes or tto)

Safety Valve Crosby 1579 Ni'A RV-4-551A Replaced No Safety Valve Crosby 1580 N/'A RV-4-55 1A NI/A Replacement No

7. Description of Work Replaced valve at tag location RV-4-551A.
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure, Other Pressure psl Test Temp ger Degree's r NOTE: Supplemental sheets in form of lists. sketches, or drawings may be used. provided (1) size is 8 If'2 in.

X 11 in.. (2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of.this form 93-042-4

Page 2 of 2 FORM NIS 2 (BCICk)

Replaced pressurizer safety valve, bolted connection no welding performed.

Applicobie Manufacturer's Data Reports lo be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this P m " conforms repair or replacement to the rules of the ASME Code.Section XI.

Type Code Symbol Stamp N j'A Certificate of Authu'ation No N/'A N/A Expiration Date Signed Owner or Owner's Designee. Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade County, Florida and employed by Arkwri ht Mutual Insurance Com an of Norwood. MA.

have inspected the components described in this Owner's Report during theperio to May 21, 1993 . and state that to the best of my knowledge and belief ~

the Owner'has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied. concerning the examinations and corrective measures described in this Owners Report. Furthermore neither the inspector nor his employer shall be liable in any manner for anypersonal injury or properly damage or a loss of any kind arising from or connected with the inspection.

Factory Mutual Engineering Assoc Commissions NB 8230 N I spector's Signature National Board. Slate. Province, and Endorsements

Page I of 2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI FLORIDA POWER & LIGHT May 21, 1993 Name P.O. BOX 029100, MIAMI, FL 33102 Sheet 1 of Address TURKEY POINT

2. Plant Unit Name P.O. BOX 3088, FLORIDA CITY, FL 33034 WOIs 92056778 PWOIs 3448 Address Repair Organization P.O. No.. Job No. etc.

3 Wo,l< Performed b FLORIDA POWER & LIGHT N/'A Type Code Symbol Stamp Name Authorization No. N/'A P.O. BOX 3088, FLORIDA CITY, FL 33034 N/'A Expiration Date Address

4. Identification of Syste Reactor Coolant S stem Quality Group A
5. (a) Applicable Construction Code ANSI 831 1 1955 Edition, N/'A Addenda, N/'A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980, Edition, Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components ASME Name of Name of Manufacturer National Other Repaired, Code Board Year Stamped Component Manufacturer Serial No. Identification Built Replaced, No. or Replacement (Yes or Na)

Safety Valve Crosby N69877000004 N/'A RV-4-551B N//A Replaced No Safety Valve Crosby N69877010008 N/'A RV-4-5518 N/'A Replacement No

7. Description of Work Replaced valve at tag location RV-4-551B.

t 8. Tests Conducted:

NOTE:

X 11 Hydrostatic Pressure Pneumatic ps l Nominal Operating Pressure Test Temp gep Degree's r Other Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 I/'2 in.

in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form 93-043-4

FORM HIS 2 (Back)

Replaced pressurizer safety valve, bolted connection no welding performed.

9. Remarks Applicable Manutacturer's Data Reports lo be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this P " conforms repair or replacement to the rules of the ASME Code.Section XI.

Type Code Symbol Stamp N/'A N//A N/'A Cerlificate of Authorization N Expiration Date Signed Date . 195m wner or Owner's Designee. Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned. holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade County. Florida and employed by Arkwri ht Mutual Insurance Com an of Norwood. MA.

have inspected the components described in this Owner's Report during theperio to May 21, 1993 . and state that to the best of my knowledge and belief.

the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied. concerning the examinations and corrective measures described in this Owners Report. Furthermore neither the inspector nor his employer shall be liable in any manner for anypersonal iniIury or property damage or a loss of any kind arising from or connected with the inspection.

Factory Mutual Engineering Assoc Commissions NB 8230 N I Notional Board. State. Province. and Endorsements

Page of 2 FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS 1

As Required by the Provisions of the ASME Code Section XI FLORIDA POWER & LIGHT May 21, 1993 Name P.O. BOX 029100, MIAMI, FL 33102 Sheet I of Address TURKEY POINT

2. Plant Unit Name P.O. BOX 3088. FLORIDA CITY, FL 33034 WOss 92056783 PWOss 3449 Address Repair Organization P.O. No.. Job No. etc.

Work Performed b FLORIDA PO ER & LIGHT Type Code Symbol Stamp NIA Authorization No. Nf'A P.O. BOX 3088, FLORIDA CITY, FL 33034 NI'A Expiration Date Address

4. Identification of Syste Reactor Coolant S stem Quality Group A
5. (a) Applicable Construction Code ANSI B31 1 1955 Edition, NI A Addenda. NI A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980, Edition, Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components ASME Name of Name of Manufacturer National Other Repaired, Code Board Year Component Manufacturer Replaced, Stamped Serial No. Identification B it (Yes or No. or Replacement No)

Safety Valve Crosby 1581 N//A RV-4-55 1C Replaced No Safety Valve Crosby N69877010009 NII'A RV-4-551C NII'A Replacement No

7. Description of Work Replaced valve at tag location RV-4-551C.

t 8. Tests Conducted:

NOTE:

X 11 Hydrostatic Pressure Pneumatic psl Nominal Operating Pressure Test Temp SST Degree's F Other Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1I'2 in.

in., (2) information in items 1 through 6 on this report is included on each sheet. and (3) each sheet is numbered and the number of sheets is recorded at the top of this form 93-044-4

FORM NIS 2 (BCICk)

9. Remarks Replaced pressurizer safety valve. bolted connection no welding performed.

Applicable Manulaclurer's Data Reports lo be attached CERTIFICATE OF'OMPLIANCE p m We certify that the statements made in the report are correct and this conforms repafr or replacement to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/'A N/A N j'A Cerlificate of Authorizatio No. Expiration Date Signed Owner or Owner's Deslpnee. 'fill~

Date j (~ 19 $ >

0 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade County, Florida and employed by Arkwri ht Mutual Insurance Com an of Norwood, MA.

have inspected the components described in this Owner's Report during theperio to May 21, 1993 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code.Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied. concerning the examinations and corrective measures described in this Owners Report. F'urthermore neither the inspector nor his employer shall be liable in any manner for anypersonal injury or property damage or a loss of any kind arising from or connected with the inspection.

Factory Mutual Engineering Assoc Commissions NB 8230 N I Inspector's Sipnalure liononol Board. Slale. Province. and Endorsemenls 19~

FORM NIS-2 OWNER'S REPORT FOR REPAlRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI F ORIDA POW R & IGHT Date

~

Sheet of

2. Plant P T Unit Name t4 Ct v4tr4+

P.O. BOX 3088 FLORIDA CITY FL 33034 p.c. Qct3%4Z-ZOOM (.<us~ pm~ 5 i,S)

Repair Organtsaten P.O. No., Job No.. etc.

3. Work Performed by

~~,~ Address g&ed cSS t~cospo~

Type Code Symbol Stamp a>%$

~

htcy5%

QoRCRosS i As os iA C~ Zoo l 'i Authorization No.

Expiration Date N/A Address

4. Identification of System
5. (a) Applicable Construction Code . 19 55 Edition, N/ Addenda, (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980, Edition, Winter 1981 Addenda

~ Code Case

6. Identification of Components Repaired or Replaced and Replacement Components ASME National Repaired, Code Name of Name of Manufacturer Other Year Board Replaced, Stamped Component JAanufaettrrer Serial No. Identification Built

~Mi4s, gq > No. r Replacement (Yes or tS" <tdrt'LM~

@3 sr .~. A" i los Ptpo 0(A o l1 tu~~

Vlf'--

Troop ptp6, QGPiA~5) <

tt w3 -i1 So Ct'r!t. i4'84 CSR. 7'loca, fliM. t'Se JHF

~4gst:

LRR g f&~~

"c-" 01'7 'iii<8 t4" hr Saic.(eO Pi@8.

tat'ob

~iOCAr f tDF Ai&oo o11 oltrrQ'9 it

7. Description of Work

> C: I.A~ Rm ~ oa REF M~ ~~W Aoa~ ~~ ~<~~ 'E: WP~ Qa P c5 oc Pi&~ oa W~~W~ PiPE ~ C~

Page 2of 2 FORM NIS-2 (Back)

9. Remarks Applicable Manufacturer's Data Reports to be attached Ja~ I WCoePO~~ ~W AADRca RV Mate,c, Po~ P Wa LtC CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp N/A Certiiicate oi Authorization No.

i

'~ /'fz'r.J K N/A Expiration Date

,, -~lzt N/A

, te

~

or Owner's Designee, Title D/'wner CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade Coun Florida and employed by Arkwri ht Mutual Insurance Com an of Norwood MA have inspected the components described in this Owner's Report during the period to , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes anywarranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Futhermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind ing from or connected with this inspection.

FACTIRY IClTUAL EMIIIKERINI ASS Commissions pector's Signature 9~

National Board, State, Province, and Endorscments

'I

Page 1 of 2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI FLORIDA POWER & LIGHT June 22 1993 0 f ~

Name P.O. BOX 029100, MIAMI, FL 33102 Sheet 1 of Address TURKEY POINT Unit Name P.O. BOX 3088. FLORIDA CITY, FL 33034 Woss 92058087 PWOss 3641 Address Repair Oreanlzanon P.O. No. Job No. elc.

~

Work Performed b FLORIDA POWER & LIGHT N/'A Type Code Symbol Stamp Name Authorization No. N/'A P.O. BOX 3088, FLORIDA CITY, FL 33034 N/'A Expiration Date Address

4. Identification of Syste Reactor Coolant S stem Ouality Group A
5. (a) Applicable Construction Code ANSI 831 1 1955 Edilion, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980, Edition. Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Repaired, ASM'ode Board Replaced Stamped Component Manufacturer Serial No. Identification Built (Yes or No. or Replacement No)

Relief Valve Copes Vulcan N/'A N/'A PCV-4-455C N/'A Replaced No

7. Description of Work Replaced Bonnet Stud and Nuts.
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other 2280 547 Pressure psl Test Temp Degree's r NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used. provided (1) size is 8 1/2 in.

X 11 in., (2) information in items 1, through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form 93-046-4

FORM NIS-"2 (Back)

Replaced bolting. no welding performed.

9. Remarks Applicable Manulaclurer's Oala tteports to be attached CERTIFICATE OF COMPLIANCE We certify, that the statements made in the report are correct and this P " conforms repair or replacement to the rules of the ASME Code.Section XI.

Type Code Symbol Stamp NJ'A N/A N j'A Certificate o Authorization No. Expiration Date Signed 0 t d'/ZZ Owner or Owner's Designee. Title CERTIFICATE OF INSERVICE INSPECTION I~ the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade County, Florida and employed by Arkwri ht Mutual Insurance Com an o( Norwood, MA.

hove inspected the components described in this Owner's Report during theperio to April 26, 1993 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty. expressed or implied, concerning the examinations and corrective measures described in this Owners Reporl. Furthermore neither the inspector nor his employer shall be liable in any manner for anypersonal injury or property damage or a loss of any kind arising from or connected with the inspection.

Factory Mutual Engineering Assoc.

Commissions NB 8230 N I nspector's Signature ttattonot Board. Slate. Province. and t;ndorsements

Page 1 of 2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI FLORIDA POWER & LIGHT "u Date Name P.O. BOX 029100, MIAMI, FL 33102 Sheet 1 of Address TURKEY POINT

2. Plant Unit Name P.O. BOX 3088, FLORIDA CITY, FL 33034 WOss 92056277 PWOss 4280 Address Repair Organization P.O. No.. Job No. etc.

Work Performed b FLORIDA POWER & LIGHT N/'A Type Code Symbol Stamp Nome Authorization No. N//A P.O. BOX 3088, FLORIDA CITY, FL 33034 N/'A Expiration Date Address

4. Identification of Syste Feed water Quality Group B
5. (a) Applicable Construction Code ANSI 831 1 1955 Edition, N/A Addenda, N/'A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980, Edition, Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components ASME Name of Name of Manufacturer National Repaired, Code Other Year Stamped Component Manufacturer Board Replaced.

Serial No. Identification Built (Yes or No. or Replacement No)

Control Valve Copes Vulcan N/'A N/'A FCV-4-498 N/'A Replaced No

7. Description of Work Replaced Bonnet Studs (4) and Nuts (4).

t 8. Tests Conducted:

NOTE:

X 11 Hydrostatic Pressure Pneumatic ps l Nominal Operating Pressure Test Temp Degree's F Other Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/'2 in.

in., (2) information in items I through 6 on this report is included on each sheet. and (3) each sheet is numbered and the number of sheets is recorded at the top of. this form 93-047-4

Page 2 of 2 FORM NIS-2 (Back)

9. Remarks Replaced bolting. no welding performed.

Applicable Manufacturer's Data Reports lo be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this P " conforms repair or replacement to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp Nj'A Certificate of Authorization No. N/A Nf'A Expiration Date Signed Date 19 g3 0 er or Owner's Designee, Tilt~

CERTIFICATE OF INSERVICE INSPECTION I. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade County, Florida and employed by Arkwri ht Mutual Insurance Com an of Norwood, MA.

have inspected the components described in this Owner's Report during theperio to June 22, 1993 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Reporl. Furthermore neither the inspector nor his employer shall be liable jn any manner for anypersonal injury or property damage or a loss of any kind arising from or connected with the inspection.

+~ 19~~

nspector's Signature Commissions Factory Mutual Engineering Assoc.

NB 8230 N I ttattonat Board. Slate; Province. and Endorsements 0

TURKEY POINT UNIT 4 1993 REFUELING OUTAGE Summary of Inservice Inspection Examinations

DATE: 08/11/93 TURKEY POINT NUCLEAR PLANT UNIT 4 PAGE: 1 REVISION: 3 INSERVICE INSPECTIOH

SUMMARY

SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (93RF)

CLASS 1 ALL STATUS COMPONENTS GENERATOR C PRIMARY SIDE N I 0 E NUMBER: 005 ASME S ONG7 SEC. XI T RSEH SUHMARY EXAMIHATION AREA CATGY EXAM A E I 0 E REMARKS HUHBER I DENT I F I CAT ION ITEH HO METHOD PROCEDURE T C G M R ""CALIBRATION BLOCK*"

REF. DWG. NO. 4-V09C 052900 4-SGC-I BOLTIHG B-G-2 VT-1 NDE 4 '-6 C - - - X 4/28/93 - VT COMPLETE, BOLT 12 HAS A INLET MAHWAY BOLTIHG 87.30 VT-1 HDE 4.1-93-0410 X - - - DENT OH THE SHANK( BOLT WAS REPLACED CTHT CHR 93-4-082 PWO 93002706

    • H/A~*

053000 4-SGC-0 BOLTIHG B-G-2 VT-1 HDE F 1-7 C - - - X 4/28/93 - VT COMPLETE, CORROSION AND OUTLET MAHWAY BOLTING 87.30 VT-1 NDE 4.1-93-0410 X - - - HOLE IN BOLTS, BOLTS WERE REPLACED CTMT CNR 93-4-083 PWO 93002706

    • N/A~*

DATE: OB/11/93 TURKEY POINT NUCLEAR PLANT UNIT 4 PAGE: 2 REVISION: 3 INSERVICE INSPECTION

SUMMARY

SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (93RF)

CLASS 1 ALL STATUS COMPOHEHTS TOR COOLANT SYSTEM LOOP A COLD LEG N I 0 E NUHBER: 009 ASME S ONGT SEC. XI T RSEH SUHHARY EXAHIHATION AREA CATGY EXAH A E I 0 E REMARKS NUHBER IDENT I F ICATION ITEH NO METHOD PROCEDURE T C G M R ~*CALIBRATION BLOCK**

SYSTEM NO. 41 5614-P-766-S SH. 1 OF 1 REF. DWG. NO. 4-A03 057500 27.5"-RCS-1407-14 B-F PT NDE 3.3-1 C X - - - 4/13/93 - PT COMPLETE( UT EXAMINATION ELBOW TO RPV NO?ZLE 85.10 UT SEE REMARKS PERFORMED DURING PREVIOUS OUTAGE, CTMTg 25 5 i IN RPV LIMITED EXAMINATION DUE TO TIGHT ACCESS IN SANDBOX AND NON REMOVABLE INSULATION, EXAMIHATION WAS PERFORMED IN ACCORDANCE WITH RELIEF REQUEST HO. 2

"*UT-32**

DATE: 08/11/93 TURKEY POINT NUCLEAR PLANT UNIT 4 PAGE: 3 REVISION: 3 IHSERVICE INSPECTION

SUMMARY

SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (93RF)

CLASS 1 ALL STATUS COHPOHEHTS TOR COOLANT SYSTEM LOOP B COLD LEG N I 0 NE NUMBER: 012 ASME S ONGT SEC. Xl T RSEH

SUMMARY

EXAMINATION AREA CATGY EXAM A E I 0 E REMARKS NUMBER IDEHT I F I CAT ION ITEM NO METHOD PROCEDURE T C G M R **CALIBRATIONBLOCK**

SYSTEM HO. 41 5614-P-766-S SH. 1 OF 1 REF. DWG. NO. 4-A06 059600 27.5".RCS-1406-14 8-F PT HDE 3.3-2 C X - - - 4/13/93 - PT COMPLETE, UT EXAMINATION ELBOW TO RPV NOZZLE 85.10 UT SEE REMARKS PERFORMED DURING PREVIOUS OUTAGE, CTMT, 25'8" IN RPV LIMITED EXAMINATION DUE TO TIGHT ACCESS IN SANDBOX AHD HON-REMOVABLE IHSULATIOH, EXAMINATION WAS PERFORMED IN ACCORDANCE WITH RELIEF REQUEST HO. 2

  • IUT 32**

H II DATE: 08/11/93 TURKEY POINT NUCLEAR PLANT UNIT 4 PAGE: 4 REVISION: 3 INSERVICE INSPECTION

SUMMARY

SECOND INTERVAL, THIRD PERIOD, SECOHD OUTAGE (93RF)

CLASS 1 ALL STATUS COMPONENTS TOR COOLANT SYSTEM LOOP C COLD LEG N I 0 HE NUMBER: 015 ASME S ONGT SEC. XI T RSEH

SUMMARY

EXAMINATION AREA CATGY EXAM A E I 0 E REMARKS NUHBER IDENT IF I CAT ION ITEM NO METHOD PROCEDURE T C G M R **CALIBRATIOHBLOCK**

SYSTEM NO. 41 5614-P 766-S SH. 1 OF 1 REF. DNG. NO. 4-A09 061700 27.5"-RCS-1409-14 B-F PT NDE 3.3-3 C X - - - 4/13/93 - PT COMPLETE( UT EXAMINATION ELBON TO RPV NOZZLE B5.10 UT SEE REMARKS PERFORMED DURING PREVIOUS OUTAGE, CTMT, 25'8", IH RPV LIMITED EXAMINATION DUE TO TIGHT ACCESS IN SANDBOX AND NON-REMOVABLE INSULATION, EXAMINATION WAS PERFORMED IN ACCORDANCE llITH RELIEF REQUEST HO. 2

    • UT 32*4

0 DATE: 08/11/93 TURKEY POINT NUCLEAR PLANT UNIT 4 PAGE: 5 REVISION: 3 INSERVICE INSPECTION

SUMMARY

SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (93RF)

CLASS 1 ALL STATUS COHPONENTS TOR COOLANT SYSTEM PRESSURIZER SURGE LINE N I 0 E NUHBER: 016 ASME S ONGT SEC. Xl T RSEH

SUMMARY

EXAMINATION AREA CATGY EXAM A E I 0 E REHARKS NUHBER IDENTIFICATION ITEM NO METHOD PROCEDURE T C G H R **CALIBRATIONBLOCK**

SYSTEH NO. 41 5614-P-766-S SH. 1 OF 1 REF. DUG. NO. 4-A10 062705 4-SR-400 IA PT TS 9.4-N93-0107 C X - - INTEGRAL ATTACHMENT REMOVED FROM INTEGRAL ATTACHHENT NIS-2 93-002-4 SERVICE, SUPPORT HAS REPLACED CTMT, 25'7" PC/M 91-200

    • N/A**

062710 SR-400 F-C VT-3(4 TS 9.9.H93-0042 C X - - SPRING HANGER WAS REPLACED, DUAL SPRING HANGER F3.50 CNO 300567 BASELINE EXAMINATION CTMT, 25'7" PC/M 91-200 NIS-2 93-002-4

    • N/A**

M 1

p(

lg

DATE: 08/11/93 TURKEY POINT NUCLEAR PLANT UNIT 4 REVISION: 3 INSERVICE INSPECTION SUMHARY SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (93RF)

CLASS 1 ALL STATUS COHPONENTS TOR COOLANT SYSTEH PRESSURIZER SAFETY LOOP A N I 0 NUMBER: 017 ASHE S ONG7 SEC. XI T RSEK SUHMARY EXAHINATION AREA CATGY EXAH A E I 0 E REHARKS NUHBER IDENT I F ICATION ITEH NO HETHOD PROCEDURE T C G H R **CALIBRATIONBLOCK**

SYSTEH NO. 41 5614-P-564-S SH. 3 OF 3 REF. DWG. NO. 4-A11 064250 4"-RC-1401-FB B-G-2 VT-1 NDE 4.1-8 C X - - - 5/3/93 - VT COHPLETE FLANGE BOLTING B7.50 CTMT, 69'0"

    • N/A**

II 0

DATE: 08/11/93 TURKEY POINT NUCLEAR PLANT UNIT 4 REVISION: 3 INSERVICE IHSPECTIOH

SUMMARY

SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (93RF)

CLASS 1 ALL STATUS COMPONENTS TOR COOLANT SYSTEM PRESSURIZER SAFETY LOOP 8 N I 0 E NUMBER: 018 ASME S OHGT SEC. XI T RSEH

SUMMARY

EXAMINATION AREA CATGY EXAM A E I 0 E REMARKS NUMBER IDENT IF I CATION ITEM NO METHOD PROCEDURE T C G M R **CALIBRATIONBLOCK**

SYSTEM HO. 41 5614-P-564-S SH. 3 OF 3 REF. DUG. NO. 4-A12 065350 4n-RC-1402-FB 8-G-2 VT-1 NDE 4.1-9 C X - - - 5/3/93 - VT COMPLETE FLANGE BOLTIHG 87.50 CTMT, 69'0"

    • H/At*

'P il e

DATE: 08/11/93 TURKEY POINT NUCLEAR PLANT UNIT 4 REVISION: 3 INSERVICE INSPECTION

SUMMARY

SECOHD INTERVAL, THIRD PERIOD, SECOND OUTAGE (93RF)

CLASS 1 ALL STATUS COMPONENTS TOR COOLANT SYSTEM PRESSURIZER SPRAY LINE N I 0 E NUMBER: 02'I ASME S OHGT SEC. XI T RSEH SUHMARY EXAMINATION AREA CATGY EXAM A E I 0 E REMARKS NUHBER IDENTIFICATION ITEH HO METHOD PROCEDURE T C G M R **CALIBRATIONBLOCK*>>

SYSTEM NO. 41 5614-P-566-S SH. 2 OF 2 REF. DMG. HO. 4-A15 071920 4-RCH-33 F-C VT-3 NDE 4.3-8 C X - - - 4/16/93 - VT COMPLETE SLIDIHG STANCHION F3 '0 CTMT, 16'3"

    • H/A**

E A" I

I

DATE: 08/11/93 TURKEY POINT NUCLEAR PLANT UNIT 4 PAGE: 9 REVISIOH: 3 INSERVICE INSPECTION

SUMMARY

SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (93RF)

CLASS 1 ALL STATUS COMPONENTS TOR COOLANT SYSTEM PRESSURIZER RELIEF LINE N I 0 E NUHBER: 022 ASME S ONGT SEC. XI T RSEH SUMHARY EXAMINATION AREA CATGY EXAM A E I 0 E REMARKS NUMBER IDENTIFICATION ITEH NO METHOD PROCEDURE T C G M R **CALIBRATIONBLOCK**

SYSTEM NO. 4'I 5614-P-564-S SN. 1 OF 3 REF. DUG. NO. 4-A16 076700 4"-RC-1406-1A 8-F RT NDE 9.3-u93- C - X - - 4/23/93 - RT COMPLETE( SURFACE NOZZLE TO SAFE-END 85.40 0167 EXAHINATION PERFORHED DURING PREVIOUS CTMT, 70'3" OUTAGE, ACCEPTABLE POROSITY AND TUNGSTEN INCLUSION, GRINDING MARKS

    • UT 53**

II' P "A

I 0

1 k1 0

DATE: 08/11/93 TURKEY POINT NUCLEAR PLANT UNIT 4 PAGE: 10 REVISION: 3 INSERVICE INSPECTION

SUMMARY

SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (93RF)

CLASS 1 ALL STATUS COMPONENTS UAL HEAT REMOVAL TO RC LOOP A COLD LEG N I 0 NUMBER: 037 ASME S ONGT SEC ~ XI T RSEH

SUMMARY

EXAMINATION AREA CATGY EXAM A E I 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE T C G M R **CALIBRATIOHBLOCK**

SYSTEM NO. 50 5614-P-509-S SH. 1 OF 4 REF. DNG. NO. 4-A31 117500 8"-RHR-1401-3 B-J PT HDE 3.3-8 C X - - - 4/24/93 - PT AND UT COMPLETE, ROOT ELBSl TO PIPE B9.11 UT 45 NDE 5.4-3 - X - GEOMETRY

. CTMT, 20'8" UT 60 NDE 5 '-3 - - X-

~*UT-41~*

B 0

4

DATE: 08/11/93 TURKEY POINT HUCLEAR PLANT UNIT 4 REVISION: 3 IHSERVICE INSPECTION

SUMMARY

SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (93RF)

CLASS 1 ALL STATUS COMPOHENTS UAL HEAT REMOVAL TO RC LOOP B COLD LEG N I 0 HE NUMBER: 038 ASME S ONGT SEC. XI T RSEH

SUMMARY

EXAMIHAT ION AREA CATGY EXAM A E I 0 E REMARKS NUMBER IDENT IF ICATION ITEM HO METHOD PROCEDURE T C G M R <<*CALIBRATIOH BLOCK**

SYSTEM NO. 50 5614-P-509-S SH. 3 OF 4 REF. DUG. NO. 4-A32 122460 8073- H-826.01 I A 8-K-1 PT NDE 3.3-3'I C X - - - 4/29/93 - PT COMPLETE INTEGRAL ATTACHMENT 810.10 CTMT, 22'2"

'AIDAN/A/A'

u '

J V

0 Wl l'f I

1

DATE: 08/11/93 TURKEY POINT NUCLEAR PLANT UNIT 4 PAGE: 12 REVISION: 3 IHSERVICE INSPECTION

SUMMARY

SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (93RF)

CLASS 1 ALL STATUS COMPONENTS UAL HEAT REMOVAL TO RC LOOP C COLD LEG N I 0 E NUMBER: 039 ASME S ONGT SEC. XI T RSEH

SUMMARY

EXAMINATION AREA CATGY EXAM A E I 0 E REMARKS NUMBER IDENTIFICATION ITEM HO METHOD PROCEDURE T C G M R **CALIBRATIONBLOCK**

SYSTEM NO. 50 5614-P-509-S SH. 4 OF 4 REF. DWG. HO. 4-A33 124800 VALVE 4-876C BOLTING B-G-2 VT-1 NDE 4.1-3 C X - - - 4/2/93 - VT COMPLETE VALVE BOLTING 87.70 CTMT, 21'6"

    • H/A**

124940 SR-449 F-C VT 3,4 HDE 4.3-77 C - - - X 5/1/93 - VT COMPLETE, BROKEN TACK WELD SPRING HANGER F3.50 CNR 93-4-080 ON WASHER, DOES HOT INTERFERE WITH CTMT, 21'6" CR 93-356 SUPPORT FUNCTION, ACCEPTED AS-IS BY EHGINEERIHG EVALUATION

    • H/A**

124960 SR-449 IA B-K-1 PT NDE 3.3-35 C X - - - 4/30/93 - PT COMPLETE INTEGRAL ATTACHMENT B10.10 CTMT, 21'64

    • N/AA*

) i I I

.0

~ '

C

DATE: 08/11/93 TURKEY POINT NUCLEAR PLANT UNIT 4 REVISION: 3 INSERVICE INSPECTION

SUMMARY

SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (93RF)

CLASS 1 ALL STATUS COHPONENTS HEAD SAFETY INJECTION LOOP A INSIDE CTMT H I 0 NUMBER: 040 ASHE S ON 0T SEC. XI T RSEH SUHHARY EXAMINATION AREA CATGY EXAM A E I 0 E REMARKS NUHBER IDENT IF I CATION ITEH NO METHOD PROCEDURE T C G M R **CALIBRATIOHBLOCK**

SYSTEM NO. 62 5614-P-512-S SN. 1 OF 2 REF. DNG. NO. 4-A34 128300 2"-Sl -1401-3 8-J PT NDE 3.3-38 C X - - - 5/4/93 - PT COMPLETE ELBSJ TO PIPE 89.40 CTMT, 28'3"

~*N/A**

I DATE: 08/11/93 TURKEY POINT NUCLEAR PLANT UNIT 4 PAGE: 14 REVISION: 3 INSERVICE INSPECTION

SUMMARY

SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (93RF)

CLASS 'I ALL STATUS COMPONENTS HEAD SAFETY INJECTION LOOP B INSIDE CTMT H I 0 E NUMBER: 041 ASHE S ONGT SEC. XI T RSEH

SUMMARY

EXAMIHAT ION AREA CAT GY EXAM A E I 0 E REMARKS NUHBER I DENT IF I CAT ION ITEM HO METHOD PROCEDURE T C G M R **CALIBRATIONBLOCK**

SYSTEM NO. 62 5614-P-513-S SH. 1 OF 2 REF. DUG. HO. 4-A35A 133500 2"-S I -1402-11 8-J PT HDE 3.3-23 C - - - X 4/24/93 - PT COMPLETE, LINEAR INDICATION PIPE TO ELBSI B9.40 PT NDE 3.3-36 X - - - ON ELBSJ, SUSPECTED MAHUFACTURIHG FLAM, CTMT, 20'1" CHR 93-4-061 5/3/93 - PT RE-EXAMINATION COMPLETE CR 93-324 ATFER INDICATION REMOVAL 4*N/A**

~ I f' l(

DATE: 08/11/93 TURKEY POINT NUCLEAR PLANT UNIT 4 PAGE: 15 REVISION: 3 INSERVICE INSPECTION SUHMARY SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (93RF)

CLASS 1 ALL STATUS COHPONENTS HEAD SAFETY INJECTION LOOP B INSIDE CTMT N I 0 E NUMBER: 044 ASHE S ONGT SEC ~ XI T RSEN SUHMARY EXAMINATION AREA CATGY EXAH A E I 0 E REHARKS NUHBER IDENTIFICATION ITEM NO METHOD PROCEDURE T C G H R **CALIBRATIONBLOCK**

SYSTEH NO. 62 5614-P-792-S SH. 1 OF 3 REF. DNG. NO. 4-A3BA 145550 8081-H-001-03 F-B VT-3 NDE 4.3-78 C - - - X 4/29/93 - VT COHPLETE, SUPPORT TAG BOX RESTRAINT F2.10 CNR 93-4-081 HISSING, TAG MILL BE REPLACED CTHT, 26'10"

    • N/P**

145700 2"-SI-1406-3 B-J PT NDE 3.3-30 C X - - - 4/29/93 - PT COHPLETE ELBON TO PIPE B9.40 CTHT, 26'10"

    • N/A**

, I ~ d 5 ~

JI Jf P"

a

DATE: 08/11/93 TURKEY POINT NUCLEAR PLANT UNIT 4 REVISION: 3 INSERVICE INSPECTION SUHMARY SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (93RF)

CLASS 1 ALL STATUS COHPONENTS ICAL 8 VOLUME CONTROL TO RC LOOP C HOT LEG N I 0 E NUMBER: 045 ASHE S ONGT SEC. XI T RSEH SUHMARY EXAHINATION AREA CATGY EXAM A E I, 0 E REHARKS NUHBER IDENT IF ICATION ITEH NO HETHOO PROCEDURE T C G M R <<*CALIBRATION BLOCK**

SYSTEM NO. 47 5614-P-782-S SH. 2 OF 3 REF. DUG. NO. 4-A39 153000 3"-CH-1401-14 8-J PT NDE 3.3-14 C X - - - 4/23/93 - PT COMPLETE PIPE TO ELBOM 89.21 CTMT

    • N/A**

153100 3"-CH-1401-15 B-J PT NDE 3.3-14 C X - - - 4/23/93 - PT COMPLETE ELBON TO PIPE B9.21 CTHT

    • N/A**

y

!'t y

I

DATE: 08/11/93 TURKEY POINT NUCLEAR PLANT UNIT 4 PAGE: 17 REVI SIGH: 3 INSERVICE INSPECTION SUMHARY SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (93RF)

CLASS 1 ALL STATUS COHPONENTS ICAL & VOLUHE CONTROL TO RC LOOP A COLO LEG N I 0 NUHBER: 046 ASHE S ONGT SEC. XI T RSEH SUHHARY EXAHIHAT I ON AREA CATGY EXAH A E I 0 E REMARKS NUHBER IDENTIFICATION ITEH NO METHOD PROCEDURE T C G M R **CALIBRATIONBLOCK**

SYSTEH NO. 47 5614-P-782-S SH. 2 OF 3 REF. DWG. NO. 4-A40 158450 SR-935 F-C VT-3,4 NDE 4.3-89 C - - - X 5/12/93 - VT COHPLETE, COLD STAMP IS NOT SPRING HANGER F3.50 CNR 93-4-098 AS SHOWN ON DRAWING, ACCEPTED AS- IS BY CTHT, 22'6" CR 93-481 EHGINEERING EVALUATION, THERE WAS NO DEVIATION FROM DESIGN INFORMATION, THE LOAD HARKS ARE FOR INFORHATION ONLY

    • N/At*

158600 3"-CH-1402-15 8-J PT NDE 3.3-27 C X - - - 4/29/93 - PT COHPLETE PIPE TO TEE 89.21 CTHT

    • N/A**

158700 3"-CH-1402-16 8-J PT NDE 3.3-27 C X - - - 4/29/93 - PT COHPLETE TEE TO PIPE 89.21 CTHT

    • N/A~*

l V

I, Ai 4, ~,w I

0 I 5 P I 4 ('"

DATE: 08/11/93 TURKEY POINT NUCLEAR PLANT UNIT 4 PAGE 18 REVISION: 3 INSERVICE INSPECTION

SUMMARY

SECOND INTERVAL, THIRD PERIOD, SECOHD OUTAGE (93RF)

CLASS 1 ALL STATUS COMPONENTS ICAL AND VOLUME COHTROL TO REGENERATIVE HX H I 0 NUMBER: 047 ASHE S ONGT SEC. XI T RSEH SUHHARY EXAMINATION AREA CATGY EXAM A E I 0 E REMARKS NUHBER IDENTIFICATION ITEM NO METHOD PROCEDURE T C G H R **CALIBRATIONBLOCK**

SYSTEM NO. 47 5614-P-551-S SH. 1 OF 1 REF. DWG. NO. 4-A41 162960 4-VCH-62 F-C VT-3 NDE 4.3-80 A - - - X 5/3/93 - VT COMPLETE, SUPPORT DOES NOT SINGLE ACTING RESTRAINT F3.10 CNR 93-4-087 MATCH DRAWINGS APPARENT BROKEN HELD@

CTHT, 25'3" CR 93-393 DAMAGE TO PIPE, BASE PLATE NOT PROPERLY PC/M 93-094 BOLTED, SUPPORT IlAS REHOVED, REDESIGNED, AND REPLACED

    • N/A*A 163300 3"-CH-1403-7 B-J PT NDE 3.3-29 C - - - X 4/28/93 - PT COMPLETE, 2 UNACCEPTABLE PIPE TO ELBOM 89.21 PT NDE 3.3-37 X - - - LINEAR INDICATIONS, 5/2/93 - PT CTMT, 17'3" PT I83-0264 X - - - RE-EXAMINATION COMPLETE, INDICATIONS CNR 93-4-074 MERE REMOVED, SURFACE ANOHOLY CR 93-349 **N/A**

PWO 93012856

l l

~t 0

P

DATE: 08/11/93 TURKEY POINT NUCLEAR PLANT UNIT 4 REVISION: INSERVICE INSPECTION

SUMMARY

SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (93RF)

CLASS 1 ALL STATUS COHPONEHTS ICAL 8 VOLUME CONTROL FROM THE REGENERATIVE HX N I 0 E NUHBER: 049 ASME S ONGT SEC. XI T RS EH SUMHARY EXAMINATION AREA CATGY EXAM A E I 0 E REMARKS NUMBER IDENT I F ICATION ITEH NO METHOD PROCEDURE T C G H R **CALIBRATIONBLOCK**

SYSTEM NO. 47 5614-P-553-S SH. 3 OF 4 REF. DUG. NO. 4-A43 170700 24-CH-1402-22 B-J PT NDE 3.3-24 C X - - - 4/26/93 - PT COMPLETE PIPE TO RESTRICTING ORIFICE 89.40 CTMT, 15'6"

    • N/A**

P b J 0

', ~

DATE: 08/11/93 TURKEY POINT NUCLEAR PLANT UNIT 4 PAGE: 20 REVISION: 3 INSERVICE IHSPECTIOH

SUMMARY

SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (93RF)

CLASS 1 ALL STATUS COMPONENTS ICAL B VOLUME CONTROL SEAL INJECTION LOOP A N I 0 E NUMBER: 050 ASME S OHGT SEC. XI T RSEH SUMHARY EXAMINATION AREA CATGY EXAM A E I 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE T C G M R **CALIBRATIONBLOCK**

SYSTEM NO. 47 5614-P-556-S SH. 1 OF 1 REF. DMG. NO. 4-A44 175500 1 '"-CH-1401-FB B-G-2 VT-1 HDE 4.1-10 C - - - X 4/27/93 - VT COMPLETE, ADDITIONAL FLANGE BOLTING B7.50 VT-1 HDE 4.1-13 X - - - CLEANING REQUIRED, 5/7/93 . VT CTMT, 29'7" CHR 93-4-066 RE-EXAMINATION COMPLETE AFTER CLEANING Pl% 93007317

    • N/A0*

b t II kl ~

DATE: 08/11/93 TURKEY POINT NUCLEAR PLANT UNIT 4 REVISION: 3 INSERVICE INSPECTION

SUMMARY

SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (93RF)

CLASS 1 ALL STATUS COMPOHENTS ICAL 8 VOLUME CONTROL SEAL INJECTION LOOP B N I 0 E NUMBER: 051 ASME S ONGT SEC. XI T RSEH SUHHARY EXAMINATION AREA CATGY EXAH A E I 0 E REHARKS NUHBER IDENT IF I CAT IOH ITEM NO METHOD PROCEDURE T C G M R **CALIBRATIONBLOCK**

SYSTEM HO. 47 5614-P-554-S SN. 1 OF 2 REF. DWG. NO. 4-A45 180350 2"-CH-1404-FB2 8-G-2 VT-1 NDE 4 ~ 1-4 C X - - - 4/27/93 - VT COMPLETE FLANGE BOLTING 87.50 CTMT, 30'7"

    • N/A*A 180450 24-CH-1404-FB3 8-G-2 VT-1 NDE 4.1-5 C X - - - 4/28/93 - VT COHPLETE FLANGE BOLTING 87.50 CTHT, 30'7"
    • H/A**

5 t h DATE: 08/11/93 TURKEY POINT NUCLEAR PLANT UNIT 4 PAGE: 22 REVISION: 3 INSERVICE INSPECTION

SUMMARY

SECOND INTERVAL, THIRD PERIOD, SECOHD OUTAGE (93RF)

CLASS 1 ALL STATUS COMPONENTS ICAL 8 VOLUME CONTROL SEAL INJECTION LOOP C H I 0 E NUMBER: 052 ASHE S ONGT SEC ~ XI T RSEH SUMHARY EXAMINATION AREA CATGY EXAM A E I 0 E REMARKS HUMBER IDENT I F I CATION ITEM HO METHOD PROCEDURE T C G M R **CALIBRATIONBLOCK**

SYSTEM NO. 47 5614-P-555-S SH. 2 OF 2 REF. DWG. NO. 4-A46 184720 2"-CH-1405.FB1 B-G-2 VT-1 NDE 4 '.11 C - - - X 4/27/93 - VT COHPLETE, 5/7/93 - VT FLANGE BOLTING B7.50 VT-1 NDE 4.1-12 X - - - RE-EXAMINATION AFTER CLEANING COMPLETE CTMT, 28'64 CHR 93.4.065 PWO 93007318

  • 'kH/A**

5 IU

DATE: OB/1'I/93 TURKEY POINT NUCLEAR PLANT UNIT 4 PAGE: 23 REVISION: 3 INSERVICE INSPECTION

SUMMARY

SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (93RF)

CLASS 1 ALL STATUS COMPONENTS TOR COOLANT PUMP A N I 0 E NUHBER: 056 ASHE S ONGT SEC. XI T RSEH SUHMARY EXAHIHAT ION AREA CATGY EXAH A E I 0 E REHARKS HUMBER IDENT IF I CATION ITEM NO METHOD PROCEDURE T C G H R **CALIBRATIONBLOCK**

SYSTEM NO. 41 REF. DWG. NO. 4-V13A 197300 4-RCP-A-FLYWHEEL RG 1.14 PT 80165-2 C X - - - 2/12/93 - PT AND UT COMPLETED BY FLYWHEEL UT 12560 X - - - WESTINGHOUSE, EXAHINED ENTIRE FLYWHEEL, CTHT MOTOR SERIAL NUHBER 1S-76P499 PLACED IN SERVICE

    • N/A**

fl A lltl e

1

DATE: 08/11/93 TURKEY POINT NUCLEAR PLANT UNIT 4 REVISION: 3 IHSERVICE INSPECTION

SUMMARY

SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (93RF)

CLASS '1 ALL STATUS COMPOHEHTS TOR COOLANT PUMP B N' 0 NUMBER: 057 ASME S ONGT SEC. XI T RSEH

SUMMARY

EXAMINATION AREA CATGY EXAM A E I 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE T C G M R <<<<CALIBRATIOH BLOCK**

SYSTEM NO. 41 REF. DWG. NO. 4-V13B 198200 4-RCP-8-FLYWHEEL RG 1.14 UT NDE 5.15-1 C X - - - 4/30/93 - UT COMPLETE FLYWHEEL CTMT

    • N/A**

4 P '

DATE: 08/11/93 TURKEY POINT NUCLEAR PLANT UNIT 4 PAGE: 25 REVISION: 3 INSERVICE INSPECTION

SUMMARY

SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (93RF)

CLASS 'I ALL STATUS COMPONENTS NERATIVE HEAT EXCHANGER N I 0 NUHBER: 059 ASHE S ONGT SEC. Xi T RSEH

SUMMARY

EXAHINATIOH AREA CATGY EXAM A E I 0 E REMARKS NUMBER IDENT I F I CATION ITEM NO METHOD PROCEDURE T C G M R **CALIBRATIONBLOCK~*

REF. DWG. NO. 4-V11 204300 RGX 4E200 VT-2 NDE 4.2-1 C X - - - 4/12/93 - VT-3 COMPLETE, 5/21/93 - VT-2 VISUAL FOR LEAKAGE VT-3 NDE 4.3-1 X - - - COMPLETE, EXAMIHED IN ACCORDANCE WITH CTMT RELIEF REQUEST HO. 3

    • N/A**

J k II v

DATE: 08/11/93 TURKEY POINT NUCLEAR PLANT UNIT 4 PAGE: 26 REVISION: 3 INSERVI CE INSPECTION

SUMMARY

SECOHD IHTERVAL, THIRD PERIOD, SECOND OUTAGE (93RF)

CLASS 2 ALL STATUS COMPONENTS GEHERATOR A SECONDARY SIDE N I 0 E NUMBER: 060 ASME S OHGT SEC. XI T RSEH

SUMMARY

EXAMINATION AREA CATGY EXAM A E I 0 E REMARKS HUHBER IDENTIFICATION ITEM HO METHOD PROCEDURE T C G M R <<*CALIBRATION BLOCK**

REF. DWG. NO. 4-V10A 204700 4-SGA-CL C-A UT 0 HDE 5.1-1 C - - - X 4/93 - UT COMPLETE, ACCEPTABLE SLAG TRANSITION TO UPPER SHELL WELD C1.10 UT 45 HDE 5.1-1 - - X X INCLUSIONS, NOZZLE GEOMETRY CTMT UT 60 NDE 5.1-1 - - - X

    • UT 7k*

205300 4-SGA-SS VT NDE 4.4-1 A X - - - 4/20/93 - VT COMPLETE SECONDARY SIDE EXAMINATION CTMT

    • N/A*~

p

'I

DATE: 08/11/93 TURKEY POINT NUCLEAR PLANT UNIT 4 REVISION: 3 INSERVI CE INSPECTION

SUMMARY

SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (93RF)

CLASS 2 ALL STATUS COMPONENTS M GENERATOR B SECONDARY SIDE N I 0 E NUMBER: 061 ASME S OH 6T SEC ~ Xl T RSEH

SUMMARY

EXAMINATION AREA CATGY EXAM A E I 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE T C G M R **CALIBRATIONBLOCK**

REF. DUG. NO. 4-V10B 206600 4-SGB-SS VT NDE 4.4-2 A X - - - 4/20/93 - VT COMPLETE SECONDARY SIDE EXAMINATION CTMT

    • H/A**

4 I! t 4 4 '

DATE: 08/11/93 TURKEY POINT NUCLEAR PLANT UNIT 4 REVISION: 3 INSERVICE INSPECTION

SUMMARY

SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (93RF)

CLASS 2 ALL STATUS COMPONENTS M GENERATOR C SECONDARY SIDE H I 0 E NUMBER: 062 ASME S ONGT SEC. XI T RSEH EXAMINATION AREA

'UMMARY CATGY EXAM A E I 0 E REMARKS NUMBER IDEHT IF I CAT IOH ITEM HO METHOD PROCEDURE T C G M R **CALIBRATIONBLOCK**

REF. DHG. HO. 4-V10C 207900 4-SGC-SS VT NDE 4.4-3 A X - - - 4/20/93 - VT COMPLETE SECONDARY SIDE EXAMINATION CTMT

    • H/A**

~ I I I A 4 I y I

\(

4,> ~

DATE: 08/11/93 TURKEY POINT NUCLEAR PLANT UNIT 4 PAGE: 29 RE V I S ION: 3 INSERVICE INSPECTION SUMHARY SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (93RF)

CLASS 2 ALL STATUS COMPONENTS S 2 PUHPS N I 0 E HUHBER: ASME S ONGT SEC. XI T RSEH SUHHARY EXAMINATION AREA CATGY EXAH A E I 0 E REHARKS NUHBER IDENTIFICATIOH ITEM NO METHOD PROCEDURE T C G M R **CALIBRATION BLOCK**

208390 RHR PUMP 4P210A VI'-1 4.1.1 C - - - X 10/20/92 - VT COMPLETE, WATER LEAKING CNR 92-4-003 FROM FLANGE, ACCEPTED AS-IS, WILL BE PWO 92047166 CORRECTED AT A FUTURE DATE WITH A PLANT WORK ORDER, EXAMS PERFORHED DURING THE 1992 UNIT 3 OUTAGE 208400 RHR PUMP 4P210B VT-1 NDE F 1-2 C - - - X 10/20/92 - VT COMPLETE, WATER LEAKING CNR 92-4-004 FROM FLANGE, BORIC ACID ACCUMULATION, PWO 92047260 ACCEPTED AS-IS, WILL BE CORRECTED AT A FUTURE DATE WITH A PLANT WORK ORDER, EXAHS PERFORMED DURING THE 1992 UNIT 3 OUTAGE

d'I l '

t g C A t

h ~ 5 t

DATE: 08/11/93 TURKEY POINT NUCLEAR PLANT UNIT 4 PAGE: 30 REVISION: 3 INSERVICE IHSPECTIOH

SUMMARY

SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (93RF)

CLASS 2 ALL STATUS COMPONENTS DUAL HEAT REMOVAL TO RESID HEAT REMOVAL H I 0 E NUMBER: 063 ASME S ONGT SEC. XI T RSEH SUHHARY EXAMINATION AREA CATGY EXAM A E I 0 E REMARKS NUHBER IDENT IF ICATION ITEM NO METHOD PROCEDURE T C G M R **CALIBRATIONBLOCK**

SYSTEM NO. 50 5614-P-503-S SH. 1 OF 2 REF. DUG. NO. 4-B01B 209900 14"-RHR-2401-15 C-F PT NDE 3.3-34 C X - - - 4/27/93 - PT COMPLETE PIPE TO VALVE 4-752A C5.11 517II

    • N/A**

210700 14"-RHR-2402-8 C-F PT NDE 3.3-34 C X - - - 4/27/93 - PT COMPLETE PIPE TO PUMP CASING C5 ~ 11

( ) 2 l9II

    • H/A~*

I'I 1 4 f I 1

DATE: 08/11/93 TURKEY POINT NUCLEAR PLANT UNIT 4 PAGE 31 REVISION: 3 IHSERVICE INSPECTION SUHHARY SECOND INTERVAL, THIRD PERIOD, SECOHD OUTAGE (93RF)

CLASS 2 ALL STATUS COMPONENTS DUAL HEAT REMOVAL TO REBID.HEAT REMOVAL PUMP B N I 0 NUHBER: 064 ASME S OHGT SEC. XI T RSEH

SUMMARY

EXAMINATION AREA CATGY EXAM A E I 0 E REMARKS NUMBER IDENT IF I CAT I OH ITEM NO METHOD PROCEDURE T C G M R **CALIBRATIONBLOCK**

SYSTEM NO. 50 5614-P-503-S SH. 1 OF 2 REF. DMG. NO. 4-B02 212900 14"-RHR-2403-12 C-F PT NDE 3.3-19 C X - - - 4/25/93 - PT COHPLETE PIPE TO PUMP CASING C5.11

( ) 2 l9II

    • H/A**

4 ~ . - Ii

~ I I' I I 1 ~ ~ 4 4

I44 V

DATE: 08/11/93 TURKEY POINT NUCLEAR PLANT UNIT 4 REVISION: 3 IHSERVICE IHSPEC'IIOH

SUMMARY

SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (93RF)

CLASS 2 ALL STATUS COHPOHENTS DUAL HEAT REMOVAL FROM CONTAIHMEHT SUMP A N I 0 NUMBER: 066 ASME S ONGT SEC. XI T RSEH SUHHARY EXAMINATION AREA CATGY EXAM A E I 0 E REMARKS NUMBER IDENT I F ICATION ITEH HO METHOD PROCEDURE T C G M R **CALIBRATIOHBLOCK**

SYSTEM NO. 50 5614-P-503-S SH. 2 OF 2 REF. DUG. NO. 4-B04 216050 14"-RHR-2405-10LS C-F PT HDE 3.3-33 C X - - - 4/27/93 - PT COMPLETE LONG SEAM C5 ~ 11 0 <4u

    • N/A**

2'l6100 14"-RHR-2405-11 C-F PT NDE 3.3-33 C X - - - 4/27/93 - PT COMPLETE PIPE TO TEE C5 ~ 11 0 I4ll

    • H/A**

~ e DATE: 08/11/93 TURKEY POINT NUCLEAR PLANT UNIT 4 PAGE: 33 REVISION: 3 INSERVICE INSPECTION

SUMMARY

SECOND INTERVAL, THIRD PERIOD, SECOHD OUTAGE (93RF)

CLASS 2 ALL STATUS COMPONENTS DUAL HEAT REMOVAL FROM CONTAINMENT SUMP B N I 0 E NUMBER: 067 ASME S ONGT SEC. XI T RSEN SUMHARY EXAMINATION AREA CATGY EXAM A E I 0 E REMARKS HUHBER IDENTIFICATION ITEM NO METHOD PROCEDURE T C G M R **CALIBRATIONBLOCK**

SYSTEM NO. 50 5614-P-503-S SH. 2 OF 2 REF. DMG. NO. 4-B05 216200 14"-RHR-2406-1 C-F PT NDE 3.3-32 C X - - - 4/29/93 - PT COMPLETE PIPE TO PIPE C5.11 7 I 5II

~*N/A**

216540 4-SR-629 F.B VT-3 HOE 4.3-69 C X - - - 4/26/93 - VT COMPLETE BOX RESTRAINT F2.10 7 I? II

    • H/A**

216560 4-SR-629 IA C-C PT NDE 3.3-32 C X - - - 4/29/93 - PT COMPLETE INTEGRAL ATTACHMENT C3.20 7l 2ll

    • N/A'k*

60 4-SR-623 IA C-C PT NDE 3.3-25 C X - - - 4/26/93 - PT COMPLE'IE INTEGRAL ATTACHMENT C3.20 Pl III

    • N/A**

,r 1'

DATE: 08/11/93 TURKEY POINT NUCLEAR PLANT UNIT 4 PAGE: 34 REVISIOH: 3 IHSERVICE INSPECTION

SUMMARY

SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (93RF)

CLASS 2 ALL STATUS COMPOHEHTS DUAL HEAT REMOVAL INSIDE B OUTSIDE CONTAINMENT N I 0 E HUHBER: 069 ASME S ONGT SEC. XI T RSEH

SUMMARY

EXAMINATION AREA CATGY EXAM A E I 0 E REMARKS NUMBER IDENT IF I CATION ITEM NO METHOD PROCEDURE T C G M R **CALIBRATIONBLOCK**

SYSTEM HO. 50 5614-P-509-S SH. 2 OF 4 REF. DUG. NO. 4-B07B 223020 124-RHR-2402-30A C-F PT NDE 3.3-10 C X - - - 4/23/93 - PT COMPLETE PIPE TO PIPE C5.1'I CTMT, 21'0"

~*H/A**

2230SO 12"-RHR-2402-30B C-F PT HDE 3.3-10 C X - - - 4/23/93 - PT COMPLETE PIPE TO PIPE C5.11 CTMT, 21'0"

    • N/A**

223400 12"-RHR-2402-34 C-F PT HDE 3.3-10 C X - - - 4/23/93 - PT COMPLETE TEE TO REDUCER C5.11 CTMT, 21'0"

    • H/A**

00 12"-RHR-2402-35 C-F PT NDE 3.3-10 C X - - - 4/23/93 - PT COMPLETE REDUCER TO VALVE 4-744A C5.11 CTMT, 21'0"

    • H/A*4

ll I 4 I' 4q 0

~ >

J

~ ~ \

DATE: 08/1'I/93 TURKEY POINT NUCLEAR PLANT UNIT 4 PAGE: 35 REVISION: 3 INSERVICE INSPECTION

SUMMARY

SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (93RF)

CLASS 2 ALL STATUS COMPONENTS DUAL HEAT REMOVAL PUMP A DISCHARGE TO RMR HX A N I 0 E NUHBER: 070 ASME S ONGT SEC. Xl T RSEH

SUMMARY

EXAHIHATIOH AREA CATGY EXAM A E I 0 E REMARKS NUMBER IDENT I F I CAT ION ITEH NO METHOD PROCEDURE T C G M R *~CALIBRATION BLOCK**

SYSTEM NO. 50 5614-P-505-S SH. 2 OF 5 REF. DUG. HO. 4-808 226300 10"-RHR.2401-16 C-F PT NDE 3.3-15 C X - - - 4/25/93 - PT COMPLETE VALVE 4-757A TO PIPE C5 ~ 11

    • N/A**

It 1 f

lt lt 'h

DATE: 08/11/93 TURKEY POINT NUCLEAR PLANT UNIT 4 PAGE: 36 REVISION: 3 IHSERVICE INSPECTION

SUMMARY

SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (93RF)

CLASS 2 ALL STATUS COMPONENTS IDUAL HEAT REMOVAL PUMP B DISCHARGE TO RHR HX B N I 0 NUMBER: 071 ASHE S ONGT SEC. XI T RSEH

SUMMARY

EXAMINATION AREA CATGY EXAM A E I 0 E REHARKS NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE T C G M R <<<<CALIBRATIOH BLOCK**

SYSTEM NO. 50 5614-P-505-S SH. 1 OF 5 REF. DUG. NO. 4-B09 227640 SR-640 F-C VT-3,4 NDE 4.3-73 C - - - X 4/26/93 - VT COMPLETEI DRAWING SPRING HANGER F3.50 CHR 93-4-075 DISCREPENCY, ACCEPTED AS-IS BY 5 I 1/2ll CR 93-347 ENGINEERING EVALUATION

<<*H/A<<*

229000 10"-RHR-2402-24 C-F PT HDE 3.3-17 C X - - - 4/25/93 - PT COMPLETE VALVE 4-7578 TO NOZZLE C5.11

    • N/A**

4

  • ,'I 0

t

DATE: 08/11/93 TURKEY POINT NUCLEAR PLANT UHIT 4 REVISION: 3 IHSERVI CE INSPECTION

SUMMARY

SECOHD INTERVAL, THIRD PERIOD, SECOND OUTAGE (93RF)

CLASS 2 ALL STATUS COMPONENTS DUAL HEAT REMOVAL HEAT EXCHANGER B DISCHARGE N I 0 NUMBER: 073 ASME S ONGT SEC. XI T RSEH

SUMMARY

EXAMINATION AREA CATGY EXAM A E I 0 E REMARKS HUMBER IDENTIFICATION ITEM HO METHOD PROCEDURE T C G M R **CALIBRATIONBLOCK**

SYSTEM NO. 50 5614-P-505-S SH. 4 OF 5 REF. DWG. NO. 4-811 230500 10"-RHR-2404-1 C-F PT HDE 3.3-16 C X - - - 4/25/93 - PT COMPLETE NOZZLE TO ELBOW C5.11

  • AN/A%*

S I4 DATE: 08/11/93 TURKEY POINT NUCLEAR PLANT UNIT 4 PAGE: 38 REVISION: 3 INSERVICE INSPECTION

SUMMARY

SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (93RF)

CLASS 2 ALL STATUS COMPOHEHTS TY INJECTION FROM REACTOR 'WATER STORAGE TAN N I 0 E NUMBER: 077 ASME S ONGT SEC. XI T RSEN

SUMMARY

EXAMIHATIOH AREA CATGY EXAM A E I 0 E REMARKS NUMBER IDEHTIFICATIOH ITEM NO METHOD PROCEDURE T C G M R **CALIBRATIOHBLOCK**

SYSTEM NO. 62 5614-P-502-S SH. 2 OF 4 REF. DWG. HO. 4-B15 231900 SR-621 F-C VT-3 HDE 4.3-6 C X - - - 4/15/93 - VT COMPLETE PIPE SUPPORT F3.10 15'7"

    • N/A%*

P C ih t'i 0

r A

~'

DATE: 08/11/93 TURKEY POINT NUCLEAR PLANT UNIT 4 PAGE: 39 REVISION: 3 IHSERVICE INSPECTION

SUMMARY

SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (93RF)

CLASS 2 ALL STATUS COMPONENTS DUA HEAT REMOVAL SYST M FROM ACCUMULATOR A N I 0 NUHBER: 078 ASHE S OHGT SEC. XI T RSEH SUHHARY EXAHINATION AREA CATGY EXAH A E I 0 E REMARKS NUMBER IDENT IF I CATION ITEM NO METHOD PROCEDURE T C G H R **CALIBRATIONBLOCK**

SYSTEM NO. 50 5614-P-509-S SH. 1 OF 4 REF. DHG. NO. 4-B16 232910 4-SIH-68 F-C VT-3,4 NDE 4.3-72 C - - - X 4/29/93 - VT COMPLETE, INADEQUATE THREAD SPRING HANGER F3.50 CNR 93-4-073 ENGAGEMENT, ACCEPTED AS-IS BY CTMT, 21'4" CR 93-348 EHGIHEERING EVALUATION

    • N/A**

232915 4-SIH-68 IA C-C PT NDE 3.3-28 C X - - - 4/29/93 - PT COMPLETE INTEGRAL ATTACHHEHT C3.20 CTMT, 21'4"

    • M/A**

I m

DATE: 08/11/93 TURKEY POINT NUCLEAR PLANT UNIT 4 PAGE: 40 REVISION: 3 INSERVICE INSPECTION

SUMMARY

SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (93RF)

CLASS 2 ALL STATUS COMPONENTS ESIDUAL HEAT REMOVAL SYSTEM FROM ACCUMULATOR 8 N I 0 f NUMBER: 079 ASHE S ONGT SEC. XI T RSEH

SUMMARY

EXAHINATIOH AREA CATGY EXAM A E I 0 E REMARKS NUMBER IDENTIFICATION ITEM NO HETHOD PROCEDURE T C G M R **CALIBRATIOHBLOCK**

SYSTEM HO. 50 5614-P-509-S SH. 3 OF 4 REF. DIJG. NO. 4-817 233000 10"-Sl-2402-1A C-F PT NDE 3.3-9 C X - - - 4/23/93 - PT AND UT COMPLETE, ROOT NOZZLE TO PIPE C5.21 UT 45 NDE 5.4-4 - X - GEOMETRY, NO EXAMIHATION FROM THE NOZZLE CTMT, 30'24 UT 60 NDE 5.4-4 - X - SIDE DUE TO ITS CONFIGURATION

  • "UT-27
  • 233100 SR-4508 F-C VT-3,4 NDE 4.3-68 C . . . X 4/23/93 - VT COMPLETE, LOOSE LOCK NUT; SPRING HANGER F3.50 VT-3,4 NDE 4.3-76 X - - - 4/30/93 - VT RE-EXAHINATIOH COMPLETE, CTMT, 20'104 CHR 93-4-060 LOCK HUT WAS TIGHTENED CR 93-323 PNO 93012700 **H/A~*

I l\

F' 0

I p4 "1

I pl "~

V'

DATE: 08/11/93 TURKEY POINT NUCLEAR PLANT UNIT 4 PAGE: 41 REVISION: 3 INSERVI CE INSPECTION

SUMMARY

SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (93RF)

CLASS 2 ALL STATUS COMPOHENTS UAL HEAT REMOVAL SYSTEM FROM ACCUMULATOR C N I 0 NUMBER: 080 ASHE S ONGT SEC. XI T RSEH

SUMMARY

EXAHIHAT ION AREA CATGY EXAM A E I 0 E REMARKS NUHBER IDENT I F I CATION ITEM NO METHOD PROCEDURE T C G M R **CALIBRATIOHBLOCK**

SYSTEM NO. 50 5614-P-509-S SH. 4 OF 4 REF. DNG. NO. 4-B18 233280 10"-SI.2403-3 C-F PT HDE 3.3-20 C X - - - 4/22/93 - PT AND UT COMPLETE, ROOT AND PIPE TO ELB(Q C5.21 UT 45 NDE 5.4-1 - X - COUHTERBORE GEOMETRY CTMT, 18'9" UT 60 HDE 5.4-1 - - X-

    • UT-27~*

r' ~ 4 . 8 *c I ~

II

DATE: 08/11/93 TURKEY POINT NUCLEAR PLANT UNIT 4 PAGE: 42 REVISION: 3 INSERVICE INSPECTION

SUMMARY

SECOND INTERVAL, THIRD PERIOD, SECOHD OUTAGE (93RF)

CLASS 2 ALL STATUS COMPONENTS TY INJECTION TO CONTAINMENT SPRAY PUMP A H I 0 NUMBER: 083 ASME S ONGT SEC. XI T RSEH

SUMMARY

EXAMINATION AREA CATGY EXAM A E I 0 E REMARKS NUMBER IDENT IF I CATION ITEM NO METHOD PROCEDURE T C G M R **CALIBRATIONBLOCK**

SYSTEM HO. 62 56'14-P-502-S SH. 1 OF 4 REF. DMG. NO. 4-B21 234070 8"-SI-2401-6 C-F PT HDE 3.3-26 C X - - - 4/29/93 - PT COMPLETE ELBOH TO VALVE 4-844A C5.11

    • H/A**

234090 8"-Sl-2401-8 C-F PT NDE 3.3-7 C X - - - 4/20/93 - PT COMPLETE REDUCING ELBOtl TO FLANGE C5.11

    • H/A**

}, P ~ ~ l,,q l

~ i v ae,, ~

ll l

DATE: 08/11/93 TURKEY POINT NUCLEAR PLANT UNIT 4 PAGE: 43 REVISION: 3 INSERVICE INSPECTION

SUMMARY

SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (93RF)

CLASS 2 ALL STATUS COMPONENTS DUAL HEAT REMOVAL SYSTEM INSIDE CONTAIHMENT N I 0 NUMBER: 085 ASHE S ONGT SEC. XI T RSEH SUHMARY EXAMINATION AREA CATGY EXAM A E I 0 E REMARKS NUMBER IDENT IF I CAT ION ITEM HO METHOD PROCEDURE T C 0 M R **CALIBRATIOHBLOCK**

SYSTEM NO. 50 5614 P 509 S SH. 2 OF 4 REF. DWG. NO. 4-823 235600 8"-SI-2403-1 C-F PT HDE 3.3-21 C X - - - 4/24/93 - PT AHD UT COMPLETE, ROOT TEE TO PIPE C5.21 UT 45 NDE 5.4-2 - X - GEOMETRY CTMT, 21'6" UT 60 HDE 5.4-3 - - X-

    • UT 41**

236000 84-SI-2403-16 C-F PT NDE 3.3-21 C X - - - 4/24/93 - PT AND UT COMPLETE, ROOT ELBOW TO PIPE C5.21 UT 45 NDE 5.4-2 - X - GEOMETRY CTMT, 26'8" UT 60 HDE 5.4-3 - X-

<<*UT-41**

236060 8N-SI-2403-17 C-F PT NDE 3.3-21 C X - - - 4/24/93 - PT AND UT COMPLETE( ROOT PIPE TO VALVE 4-876B C5.21 UT 45 NDE 5.4-2 - X - GEOMETRY CTMT, 26'8" UT 60 NDE 5.4-2 - X-

    • UT-41**

'N gt C

o E

DATE: 08/'11/93 TURKEY POINT HUCLEAR PLANT UNIT 4 REVISION: 3 INSERVICE INSPECTION

SUMMARY

SECOHD INTERVAL, THIRD PERIOD, SECOND OUTAGE (93RF)

CLASS 2 ALL STATUS COMPONENTS TY INJECTION SYSTEM OUTSIDE CONTAINMENT H I 0 NUMBER: 087 ASME S ONGT SEC. XI T RSEH

SUMMARY

EXAMINATION AREA CATGY EXAM A E I 0 E REMARKS HUHBER IDENTIFICATION ITEM NO METHOD PROCEDURE T C G M R **CALIBRATIONBLOCK**

SYSTEM NO. 62 5614-P-502-S SH. 1 OF 4 REF. DNG. NO. 4-B25 237100 8"-Sl-2405-7 C-F PT NDE 3.3-5 C X - - - 4/20/93 - PT COMPLETE VALVE 4-844B TO PIPE C5.11

    • H/A**

237200 8"-Sl-2405-8 C-F PT NDE 3.3-5 C X - - - 4/20/93 - PT COMPLETE PIPE TO REDUCER C5.11

%AH/A*A'37300 8"-SI-2405-9 C-F PT HDE 3.3-5 C X - - - 4/20/93 - PT COMPLETE REDUCER TO FLANGE C5.11

    • H/A**

~ t I w

. ~

,1

DATE: 08/11/93 TURKEY POINT NUCLEAR PLANT UNIT 4 REVISION: 3 INSERVICE INSPECTION SUMHARY SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (93RF)

CLASS 2 ALL STATUS COMPONENTS DUAL HEAT REHOVAL SYSTEM INSIDE CONTAINMENT N I 0 NUHBER: 089 ASME S ONGT SEC. XI T RSEH SUHMARY EXAMINATION AREA CATGY EXAH A E I 0 E REMARKS NUHBER IDENT IF ICATION ITEH NO METHOD PROCEDURE T C G H R **CALIBRATIONBLOCK**

SYSTEH NO. 50 5614-P-509-S SH. 1 OF 4 REF. DWG. NO. 4-827 238950 4-89-A1 F-8 VT-3 NDE 4.3-71 C X - - - 4/26/93 - VT COMPLETE ANCHOR F2.10 CTMT, 26'04

    • N/A**

238960 4-89-A1 IA C-C PT NDE 3.3-22 C X - - - 4/24/93 - PT COHPLETE INTEGRAL ATTACNHENT C2.30 CTHT, 26'0"

+*N/A**

241350 SR-445 F-B VT-3 NDE 4.3-70 C X - - - 4/26/93 - VT COHPLETE

.BOX RESTRAINT F2.10 CTHT, 18'44

    • N/A**

lj I ~

DATE: 08/11/93 TURKEY POINT NUCLEAR PLANT UNIT 4 PAGE: 46 REVISION: 3 INSERVICE INSPECTION SUHMARY SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (93RF)

CLASS 2 ALL STATUS COMPOHENTS DUAL HEAT REMOVAL SYSTEH OUTSIDE CONTAINMENT N I 0 NUMBER: 090 ASHE S ONGT SEC. XI T RSEH SUMHARY EXAMINATION AREA CATGY EXAM A E I 0 E REMARKS NUHBER IDENTIFICATION ITEH NO HETHOD PROCEDURE T C G M R **CALIBRATIONBLOCK**

SYSTEH NO. 50 5614-P-504-S SH. 1 OF 2 REF. DWG. NO. 4-B28 245500 84-SI -2408-14 C-F PT HDE 3.3-18 C X - - - 4/25/93 - PT COHPLETE PIPE TO ELBOW C5 ~ '11 19'On

%*N/A**

245600 8"-Sl-2408-15 C-F PT NDE 3.3-18 C X - - - 4/25/93 - PT COMPLETE ELBOW TO VALVE 4-10.872 C5.11 20'0" t*N/A**

245700 8"-SI-2408-16 CF PT NDE 3.3-18 C X - - - 4/25/93 - PT COHPLETE, 4/29/93 - UT VALVE 4-10-872 TO ELBOW C5.21 UT 45 NDE 5.4-6 - - X - COMPLETE, COUNTERBORE AND ROOT GEOMETRY 20'0" UT 60 NDE 5.4-6 - - X-

    • UT 41**

00 8"-Sl-2408-17 C-F PT NDE 3.3-18 C X - - - 4/25/93 - PT COHPLETE; 4/29/93 - UT ELBOW TO ELBOW C5.21 UT 45 NDE 5.4-6 - X - COHPLETE, ROOT AND COUHTERBORE GEOHETRY 25 I 0 l I UT 60 NDE 5.4 6 - - X-

    • O'I 41**

246100 8"-Sl-2408-18 C-F PT NDE 3.3-18 C X - - - 4/25/93 - PT COHPLETE; 4/29/93 - UI' ELBOW TO PENETRATION 11 C5 ~ 21 UT 45 NDE 5.4-6 - X - COMPLETE, ROOT GEOMETRY 26I 0 I UT 60 NDE 5 '-6 X - --

    • UT 41**

tl i

fi it 1 w

DATE: 08/11/93 TURKEY POINT NUCLEAR PLANT UNIT 4 PAGE: 47 REVISION: 3 INSERVICE IHSPECTIOH

SUMMARY

SECOHD INTERVAL, THIRD PERIOD, SECOND OUTAGE (93RF)

CLASS 2 ALL STATUS COMPONENTS TY INJECTION PUMP D SUCTION H I 0 NUMBER: 093 ASME S ONGT SEC ~ XI T RSEH SUHMARY EXAMINATION AREA CATGY EXAM A E I 0 E REMARKS NUMBER IDENT I F I CAT ION ITEM NO METHOD PROCEDURE T C G M R **CALIBRATIOHBLOCK**

SYSTEM HO. 62 5614-P-502-S SH. 4 OF 4 REF. DWG. HO. 4-B31 249400 6"-Sl-2402-3 C-F PT NDE 3.3-4 C X - - - 4/16/93 - PT COMPLETE ELBOM TO PIPE C5.11

    • H/A~*

249440 6"-Sl-2402-3LD C-F PT HDE 3.3-4 C X - - - 4/16/93 - PT COMPLETE 2.5T OF LONG SEAM DOWNSTREAM C5.12 OF llELD 3

    • H/A**

P n g ~

~ ~

DATE: 08/'11/93 TURKEY POINI'UCLEAR PLANT UNIT 4 REVISION: 3 IHSERVICE INSPECTION

SUMMARY

SECOHD INTERVAL, THIRD PERIOD, SECOND OUTAGE (93RF)

CLASS 2 ALL STATUS COMPONENTS IDUAL HEAT REHOVAL SYSTEM TO REFUELIHG CAHAL N I 0 NUHBER: 094 ASME S ONGT SEC ~ XI T RSEH SUHMARY EXAHIHATIOH AREA CATGY EXAM A E I 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE T C G M R **CALIBRATIOHBLOCK**

SYSTEM NO. 50 5614-P-575-S SH. 1 OF 1 REF. DWG. NO. 4-B32 251300 6"-SI-2403-15 C-F PT NDE 3.3-13 C X - - - 4/24/93 - PT COMPLETE PIPE TO ELBOW C5 ~ 1'I CTMT, 15'1'I"

    • N/A4*

251400 6"-Sl-2403-16 C-F PT NDE 3.3-13 C X - - - 4/24/93 - PT COMPLETE ELBOW TO PIPE C5.11 CTMT, 16'8"

  • ~H/A~*

<<)

v'c h ) J, I

III

DATE: 08/11/93 TURKEY POINT NUCLEAR PLANT UNIT 4 PAGE: 49 REVISION: 3 INSERVICE INSPECTION SUHMARY SECOND IN'IERVAL, THIRD PERIOD, SECOND OUTAGE (93RF)

CLASS 2 ALL STATUS COMPONENTS AINMENT SPRAY PUMP 8 DISCHARGE N I 0 HUHBER: 096 ASME S ONGT SEC. XI T RSEH SUHHARY EXAHINATION AREA CATGY EXAM A E I 0 E REHARKS NUHBER IDENTIFICATION ITEM NO METHOD PROCEDURE T C G M R **CALIBRATIOHBLOCK**

SYSTEM NO. 68 5614-P-511-S SH. 'I OF 1 REF. DNG. NO. 4-834 255000 6"-CS-2402-1A C-F PT NDE 3.3-6 C X - - - 4/20/93 - PT COMPLETE FLANGE TO REDUCING ELBOW C5.11 21 I 4ll

    • N/A**

255200 6"-CS-2402-3 C-F PT NDE 3.3-6 C X - - - 4/20/93 - PT COMPLETE PIPE TO VALVE 4-8808 C5.11 22 I4II

    • N/A~*

g t

DATE: 08/11/93 TURKEY POINT NUCLEAR PLANT UNIT 4 PAGE: 50 REVISION: 3 INSERVICE INSPECTION

SUMMARY

SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (93RF)

CLASS 2 ALL STATUS COMPOHEHTS N INJECTION ANK DISCHARGE N I 0 NUMBER: 098 ASME S ONGT SEC. XI T RSEN

SUMMARY

EXAMINATION AREA CATGY EXAM A E I 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE T C G M R +*CALIBRATIOH BLOCK**

SYSTEM 62 5614-P-783-S SH. 1 OF 3 REF. DWG. NO. 4-835 257800 6"-CS-2404-1 C-F PT HDE 3.3-4'I C X - - - 5/4/93 - PT COMPLETE NOZ2LE TO ELBOW C5.11

    • N/A**

,l 4

t p IY "J ~ ~

1I l

DATE: 08/11/93 TURKEY POINT NUCLEAR PLANT UNIT 4 REVISION: 3 INSERVICE INSPECTION

SUMMARY

SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (93RF)

CLASS 2 ALL STATUS COMPONENTS STEAH SYSTEH LOOP A INSIDE CONTAINMENT H I 0 NUMBER: 099 ASHE S ONGT SEC. XI T RSEH SUMHARY EXAHINATION AREA CATGY EXAM A E I 0 E REMARKS NUMBER IDENTIFICATION ITEH NO METHOD PROCEDURE T C G M R **CALIBRATIONBLOCK**

i SYSTEM NO. 72 5614-P-559-S SH. 1 OF 1 REF. DIJG. NO. 4-037 259500 4-99-A1 F-B VT NDE 4.3-85 C X - - - 5/4/93 - VT COMPLETE AHCHOR F2.10 CTMT, 54'10"

    • N/A~*

259550 4-99-A1 IA C-C MT NDE 2 '-11 C X - - - 5/4/93 - MT COMPLETE INTEGRAL ATTACHHEHT C3.20 CTHT, 54'10" 4*N/A**

A

~ l tl

,I

DATE: 08/11/93 TURKEY POINT NUCLEAR PLANT UNIT 4 REVISION: 3 INSERVICE INSPECTION SUHMARY SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (93RF)

CLASS 2 ALL STATUS COHPONENTS STEAN SYSTEH LOOP B INSIDE CONTAINMENT N I 0 E NUHBER: 'IOO ASHE S ONGT SEC. XI T RSEN SUHMARY EXAHIHAT ION AREA CATGY EXAH A E I 0 E REMARKS NUNBER IDENTIFICATION ITEN HO METHOD PROCEDURE T C G H R **CALIBRATIONBLOCK**

SYSTEH NO. 5614-P-560-S SN. 1 OF 1 REF. DWG. NO. 4-B38 260600 4-100-A1 F-B VT-3 NDE 4.3-86 C X - - - 5/6/93 - VT COHPLETE ANCHOR F2.10 CTHT, 54'10"

    • N/A**

260650 4-100-A1 IA C-C HT NDE 2.2-14 C X - - - 5/5/93 - MT COMPLETE INTEGRAL ATTACHMENT C3.20 CTHT, 54'04

    • N/A**

v,'4 II l

1

DATE: 08/11/93 TURKEY POINT NUCLEAR PLANT UNIT 4 PAGE: 53 REVISION: 3 INSERVICE INSPECTION SUHHARY SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (93RF)

CLASS 2 ALL STATUS COMPONENTS M GENERATOR A BLOWDOWN INSIDE CONTAINMENT N I 0 E NUMBER: 105 ASME S OHGT SEC. XI T RSEH SUHHARY EXAHIHAT ION AREA CATGY EXAH A E I 0 E REHARKS NUMBER IDENT IF ICATION ITEM NO HETKOO PROCEDURE T C G H R **CALIBRATIONBLOCK**

SYSTEH NO. 71 5614-P-790-S SH. 2 OF 3 REF. DWG. NO. 4-B49A 268760 781028-H-420-12 IA C-C HT NDE 2.2-9 C X - - - 5/3/93 - HT COHPLETE INTEGRAL ATTACHMENTS C3.20 CTMT, 32'6"

    • N/A4*

269860 781028-H-420-09 IA C-C HT NDE 2.2-9 C X . - - 5/3/93 - HT COHPLETE INTEGRAL ATTACHMENTS C3.20 CTHT, 25'8"

    • N/A**

SYSTEH NO. 71 5614-P-790-S SN. 1 OF 3 REF. DWG. NO. 4-B49B 270200 6"-BDA-2401-17 C-F HT NDE 2.2-7 C X - - . 5/3/93 - Ml'OMPLETE, 5/4/93 - UT PIPE TO PIPE C5.21 UT 45 NDE 5 '-1 - X . COMPLETE( ROOT GEOHETRY CTHT, 20'6" UT 60 NDE 5.2-1 X - --

    • UT-22**

70220 78102B- H-420-08 F-8 VT-3 NDE 4.3.82 C X . - . 5/3/93 - VT COMPLETE BOX RESTRAINT F2.10 CTHT, 21'0"

    • N/A~*

270240 78102B-H-420-08 IA C-C HT NDE 2.2-8 C X - - - 5/3/93 - MT COHPLETE INTEGRAL ATTACNHENTS C3.20 CTHT, 21'04

    • N/A~*

270440 78102B-H-420.03 F-B VT-3 NDE 4.3.67 C - - - X 4/24/93 - VT COMPLETE( SUPPORT DOES NOT BOX RESTRAINT F2.10 CNR 93-4-050 MATCH DRAWING, ACCEPTED AS-IS BY CTHT, 26'0" CR 93-300 ENGINEERING EVALUATION

    • N/A~*

270460 781028-H-420.03 IA C-C HT NDE 2.2-3 C X - - - 4/22/93 - HT COHPLETE INTEGRAL ATTACHHENT C3.20 CTHT, 26'0"

    • N/A+*

it ~ P 'k

'1 ~ r4 ~

c II I I A f

0

DATE: 08/11/93 TURKEY POINT NUCLEAR PLANT UNIT 4 PAGE: 54 REVISION: 3 IHSERVICE INSPECTION

SUMMARY

SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (93RF)

CLASS 2 ALL STATUS COMPONENTS H GENERATOR A SLOWDOWN IHSIDE CONTAINMENT N I 0 NUMBER: 105 ASME S OHGT SEC. XI T RSEH

SUMMARY

EXAMINATION AREA CATGY EXAM A E I 0 E REMARKS NUMBER IDENT IF I CATION ITEM NO METHOD PROCEDURE T C G M R **CALIBRATIONBLOCK**

SYSTEM NO. 71 5614-P-790-S SH. 1 OF 3 REF. DWG. NO. 4-B49B 270540 781028-H-420.02 F-B VT-3 HDE 4.3-81 C X - - - 5/3/93 - VT COMPLETE BOX RESTRAINT F2.10 CTMT, 26'04

    • N/A~*

270560 781028-H-420-02 IA C-C PT HDE 3.3-39 C X - - - 5/4/93 - PT COMPLETE, ACCEPTABLE ROUNDED INTEGRAL ATTACHMEHTS C3.20 AND LINEAR INDICATIONS CTMT, 26'0"

  • ~N/A~~

270760 26'0"'-C 781028-H-420-01 IA INTEGRAL ATTACHMENTS CTMT, C3.20 PT NDE 3.3-42 C X - - - 5/3/93 -

  • AH/A*A PT COMPLETE

I L 1 0

e I H

[II

DATE: 08/11/93 TURKEY POINT NUCLEAR PLAN'I UNIT 4 PAGE: 55 REVISION: 3 INSERVICE INSPECTION

SUMMARY

SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (93RF)

CLASS 2 ALL STATUS COMPONENTS M GENERATOR B BLOWDOW INSIDE CONTAINMENT N I 0 E NUHBER: 106 ASME S OHGT SEC. XI T RSEH

SUMMARY

EXAHIHATION AREA CATGY EXAM A E I 0 E REMARKS NUMBER IDENTIFICATION ITEH NO HETHOD PROCEDURE T C G M R **CALIBRATIONBLOCK**

SYSTEH NO. 71 5614-P-791-S SN. 1 OF 1 REF. DUG. NO. 4-BSOA 272960 781028-H-421-06 IA C-C HT NDE 2.2-10 C X - - - 5/3/93 - H'I COMPLETE INTEGRAL ATTACNMEHTS C3 ~ 20 CTHT, 33'11"

    • N/A**

SYSTEM NO. 71 5614-P-791-S SN. 1 OF 1 REF. DWG. NO. 4-BSDB 273650 781028-H-421-02 F-8 VT-3 NDE 4.3-84 C X - - - 5/3/93 - VT COMPLETE BOX RESTRAINT F2.10 CTMT, 25'0"

    • N/A**

273660 781028-H-421-02 IA C-C PT NDE 3.3.40 C - - - X 5/4/93 - PT COMPLETE, ALIGNED ROUNDED INTEGRAL ATTACHHEHTS C3 ~ 20 PT NDE 3.3.44 X - - INDICATIONS, INDICATIONS REMOVED, CTHT, 25'0" CNR 93-4-090 SURFACE ANOMOLY CR 93-415

    • N/A**

273850 781028-H-421-01 F-8 VT-3 NDE 4.3-83 C X - - - 5/3/93 - VT COMPLETE BOX RESTRAINT F2.10 CTMT, 25'0"

    • N/A>>"

273860 781028-H-421-01 IA C-C PT NDE 3.3-43 C X - - - 5/4/93 - PT COMPLETE INTEGRAL ATTACHMENTS C3.20 CTMT, 25'04

    • N/A4*

~ '

DATE: 08/11/93 TURKEY POINT NUCLEAR PLANT UNIT 4 PAGE: 56 REVISION: 3 INSERVICE INSPECTION

SUMMARY

SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (93RF)

CLASS 2 ALL STATUS COMPONENTS M GENERATOR C BLOWDOWN INSIDE CONTAINMENT N I 0 E NUHBER: 107 ASHE S ONGT SEC. XI T RSEH

SUMMARY

EXAMINATION AREA CATGY EXAH A E I 0 E REHARKS NUHBER IDENT IF I CAT ION ITEH NO METHOD PROCEDURE T C G M R **CALIBRATIONBLOCK*<<

SYSTEM NO. 71 5614-P-785-S SH. 1 OF 3 REF. DMG. NO. 4-B51B 276450 781028-H-422-03 F-8 VT-3 NDE 4.3-74 C X - - - 4/28/93 - VT COHPLETE BOX RESTRAINT F2.10 CTHT, 25'0"

    • N/A**

276460 781028-H.422-03 IA C-C MT NDE 2.2-5 C X - - - 4/28/93 - HT COMPLETE INTEGRAL ATTACHHENT C3.20 CTHT, 25'0"

<<*N/A**

276540 781028-H-422-02 F-8 VT-3 NDE 4.3-75 C X - - - 4/28/93 - VT COMPLETE PIPE SUPPORT F2.10 CTHT, 25'0"

<<*N/A<<*

60 781028-H-422-02 IA C-C MT HDE 2.2-4 C X - - 4/28/93 - MT COMPLETE INTEGRAL ATTACHHENT C3.20 CTHT, 25'0"

    • N/A**

DATE: 08/11/93 TURKEY POINT NUCLEAR PLANT UNIT 4 PAGE: 57 REVISION: 3 INSERVICE INSPECTION

SUMMARY

SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (93RF)

CLASS 2 ALL STATUS COMPONENTS FEEDWATER SYSTEM LOOP A N I 0 NUMBER: 111 ASME S ONGT SEC ~ XI T RSEH SUMHARY EXAMINATION AREA CATGY EXAM A E I 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE T C G M R **CALIBRATIONBLOCK**

SYSTEM HO. 74 5614-P-557-S SH. 1 OF 1 REF. DWG. NO. 4-B55B 282245 4-FWH-19A IA C-C MT NDE 2.2-16 C X - - - 5/8/93 - MT COMPLETE INTEGRAL ATTACHMENTS C3.20 CTMT, 51'10"

    • H/A**

282950 14"-FWA-2401-28 C-F MT NDE 2.2-19 C X- 5/15/93 - MT AND UT COMPLETE BEFORE HEAT PIPE TO REDUCER C5.21 HDE 2.2-23 X - -- TREATMENT, 5-17 MT AND UT COMPLETE CTMT, 68'5" Ml'T 0 HDE 5.2-6 X - -- AFTER HEAT TREATMENT, ROOT AND UT 45 NDE 5.2-6 - - X- COUNTERBORE GEOMETRY, BASELINE UT 60 NDE 5.2-6 - X- EXAMINATION UT 70 HDE 5 '-6 - - X- **UT 20**

UT 0 NDE 5.2-10 X - --

UT 45 NDE 5.2-10 - - X-UT 60 HDE 5.2-10 - - X-83050 18"-FWA-2401-29 C-F MT NDE 2.2-20 C X- 5/15/93 - MT AND UT COMPLETE BEFORE HEAT REDUCER TO NOZZLE C5.21 MT NDE 2.2-23 X- TREATMENT, 5/17/93 - MT AND UT COMPLETE CTMT, 68'5" UT 0 HDE 5.2-5 X--- AFTER HEAT TREATMENT, ROOT GEOMETRY, UT 45 HDE 5.2-5 --X- BASELINE EXAMINATION UT 60 NDE 5.2-5 --X- **UT 29**

UT 0 NDE 5.2-9 X---

UT 45 NDE 5.2-9 --X-UT 60 HDE 5.2-9 --X-284460 AUGMENTED EXAM IE BUL UT HDE 5.16-1 C - - - X 5/1/93 - CRACKLIKE INDICATIONS FOUND IN STEAH GENERATOR FEEDWATER 79-13 VT-1 NDE 4 '-14 X - - - THE NOZZLE TO REDUCER WELD, VISUAL NOZZLE PIPING CHR 93-4-069 EXAMINATION PERFORMED ON INSIDE SURFACE CTMT, 68'5" CR 93-370 OF NOZZLE AFTER REDUCER REMOVAL, REDUCER PWO 93013356 WAS REPLACED AHD A BASELINE EXAMINATION UT HDE 5.16-4 - - X - PERFORMED

    • UT-208 UT-29**

IJ K'

l*

DATE: 08/11/93 TURKEY POINT NUCLEAR PLANT UNIT 4 PAGE: 58 REVISION: 3 INSERVICE INSPECTION SUHMARY SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (93RF)

CLASS 2 ALL STATUS COMPONENTS N FEEDWATER SYSTEM LOOP B N I 0 NUMBER: 112 ASHE S ONGT SEC. XI T RSEH SUHHARY EXAHINATION AREA CATGY EXAM A E I 0 E REMARKS HUH BE R IDENT I F I CAT ION ITEH NO METHOD PROCEDURE T C G H R **CALIBRATIONBLOCK**

SYSTEH NO. 74 5614-P-558-S SH. 1 OF 1 REF. DUG. NO. 4-B56 285960 80116- R-005-01 IA C-C MT NDE 2.2-12 C X - - - 5/5/93 - HT COHPLETE INTEGRAL ATTACHMENTS C3.20 CTMT, 60'3"

%*N/A**

286550 14"-FNB-2402-20 C-F Ml'OE 2.2-21 C X---

X--

5/16/93 - MT AND UT COMPLETE BEFORE HEAT PIPE TO PIPE C5.21 MT NDE 2.2-24 TREATMENT, 5/18/93 - MT AND UT COMPLETE CTHT, 68'6" UT 0 NOE 5.2-8 X--- AFTER HEAT TREATMENT, ROOT GEOHETRY, UT 45 HDE 5.2-8 -X- BASELINE EXAMINATION UT 60 HDE 5.2-8 -X- **UT-20**

UT 70 NOE 5.2-8 -X-UT 45 NDE 5 '-11 -X-UT 60 HDE 5.2-11 -X-UT 70 NDE 5.2-11 -X-UT 0 NOE 5 '-12 X-50 144-FNB-2402-21 C-F HT NDE 2.2-17 C X--- 5/11/93 - MT AND UT COMPLETE BEFORE HEAT PIPE TO REDUCER C5.21 HT HDE 2.2-24 X--- TREATMENT, 5/18/93 - MT AND UT COMPLETE CTHT, 68'6" UT 0 NDE 5.2-2 X--. AFTER HEAT TREATHENT, ROOT AND UT 45 NDE 5.2-2 COUNTERBORE GEOMETRY, BASELINE UT 60 NDE 5.2-2 - X- EXAMINATION UT 45 NDE 5.2-14 - X- +*UT-20**

UT 60 NDE 5.2-14 - X-UT 70 NDE 5.2-14 - X-286750 18"- FMB-2402-22 C-F MT NDE 2.2-22 C X--- 5/16/93 - MT AND UT COMPLETE BEFORE HEAT REDUCER TO NOZZLE C5.21 MT NDE 2.2-24 X- TREATHENT, 5/18/93 - HT AND UT COHPLETE CTMT,68'6" UT 0 NDE 5.2-7 X--- AFTER HEAT TREATMENT, ROOT GEOMETRY, UT 45 NDE 5 '-7 X- BASELINE EXAMIHATION UT 60 NDE 5.2-7 X- +*UT-29**

UT 45 NDE 5 '-13 X-UT 60 HDE 5.2-13 286980 AUGMENTED EXAM IE BUL UT NDE 5 '6-1 C - - - X 5/1/93 - CRACKLIKE INDICATIONS FOUND IN STEAH GEHERATOR FEEDIIATER 79-13 VT-1 HDE 4.1-15 X - - - THE NOZZLE TO REDUCER HELD, VISUAL NOZZLE PIPING CNR 93-4-069 EXAHINATION PERFORHED ON THE INSIDE CTHT, 68'6" CR 93-370 SURFACE OF NOZZLE AFTER REDUCER REMOVAL, PWO 93013356 REDUCER I(AS REPLACED AND A BASELINE UT NDE 5.16-5 - X - EXAMINATION PERFORHED

    • UT-20, UT-29**

'f If II 0

\ j

DATE: 08/11/93 TURKEY POINT NUCLEAR PLANT UNIT 4 PAGE: 59 REVISION: 3 INSERVICE INSPECTION SUHHARY SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (93RF)

CLASS 2 ALL STATUS COMPONENTS FEEDIIATER SYSTEM LOOP C N I 0 E HUMBER: 113 ASME S ONGT SEC. XI T RSEH SUHMARY EXAHINATION AREA CATGY EXAM A E I 0 E REMARKS NUHBER IDENT IF ICATION ITEM NO METHOD PROCEDURE T C G M R **CALIBRATIONBLOCK**

SYSTEM NO. 74 5614-P-789-S SH. 1 OF 1 REF. DUG. NO. 4-B57 288440 80116-R-006-02 IA CC HT NDE 2.2-15 C X - - - 5/7/93 - HT COMPLETE INTEGRAL ATTACHMENTS C3.20 CTHT, 51'10"

    • N/A**

288670 80116-R-006-01 IA C-C MT NDE 2.2-13 C X - - - 5/5/93 - MT COMPLETE INTEGRAL ATTACHMENTS C3 ~ 20 CTHT, 61'3"

    • N/AA*

289050 14"-FWC-2403-19 C-F UI' NDE 5.2-15 A X - - - 5/18/93 -UT COMPLETE PIPE TO PIPE C5.21 UT 45 NDE 5.2-15 X-CTHT, 68'5" UT 60 NDE 5.2-15 X - --

    • UT-20**

50 14"-FHC-2403-20 C-F MT NDE 2.2-18 C X--- 5/15/93 - MT AND UT COMPLETE BEFORE HEAT PIPE TO REDUCER C5.21 MT NDE 2.2-25 X--- TREATHENT, 5/18/93 HT AND UT COMPLETE CTHT, 68'5" UT 0 NDE 5.2-3 X- AFTER HEAT TREATMENT, ROOT AND UT 45 NDE 5.2-3 -X- COUN'IERBORE GEOMETRY, BASELINE UT 60 NDE 5.2-3 -X- EXAHINATION UT 0 NDE 5.2-15 X--- *~UT-20**

UT 45 NDE 5.2-15 X-UT 60 NDE 5.2-15 -X-289250 18"-FHC-2403-21 CF HT NDE 2.2-18 C X--. 5/15/93 - MT AND UT COMPLETE BEFORE HEAT REDUCER TO NOZZLE C5.21 HT NDE 2.2-25 X- TREATMENT, 5/18/93 - HT AND UT COMPLETE CTHI', 68'5" UT 0 NDE 5.2-4 X- AFTER HEAT TREATMENT, ROOT GEOHETRY, UT 45 NDE 5 '-4 -X- BASELINE EXAHINATION UT 60 NDE 5.2-4 X- *OUT 29**

UT 0 NDE 5.2-16 X-UT 45 NDE 5.2-16 X-UT 60 NDE 5.2-16 X-289650 AUGMEHTED EXAH IE BUL UT NDE 5.16-3 C ---X 4/23/93 - UT COMPLETE, CRACKLIKE STEAH GENERATOR FEEDLIATER 79-13 VT-1 NDE 4.1-16 X- INDICATIONS FOUND IN THE NOZZLE TO NOZZLE PIPING CNR 93-4-069 REDUCER l!ELD, VISUAL EXAMINATION CTHT, 68'5" CR 93-370 PERFORMED ON THE INSIDE SURFACE OF PIO 93013356 NOZZLE AFTER REDUCER REHOVAL, REDUCER UT NDE 5.16-6 - - X- HAS REPLACED AND A BASELINE EXAMINATION PERFORMED

  • UT-ZQ, UI-29**

Il ~

I

))

h )

II

~

/

'Y Iy Ir h II ")II" Ith, '

  • lh

DATE: 08/11/93 TURKEY POINT NUCLEAR PLANT UNIT 4 PAGE: 60 REVISION: 3 INSERVICE INSPECTION

SUMMARY

SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (93RF)

CLASS 2 ALL STATUS COMPONENTS N FEEDWATER BYPASS LOOP A N I 0 NUMBER: 114 ASME S ONGT SEC. XI T RSEH

SUMMARY

EXAHINATI ON AREA CATGY EXAH A E I 0 E REMARKS NUHBER IDENTIFICATION ITEM NO METHOD PROCEDURE T C G M R **CALIBRATIONBLOCK**

SYSTEM NO. 74 5614-P-770-S SH. 3 OF 4 REF D'NG. NO. 4-858 290100 7884-R-014-01 F-C VT-3 NDE 4.3-79 C - - - X 5/1/93 - VT COMPLETEI CHIPPED CONCRETE BOX RESTRAINT F3.'10 CNR 93-4-085 AROUND BASE PLATE, PWO ISSUED TO CORRECT 40 IOII PlJO 93007585 AT A LATER DATE

    • N/A**

290150 7884-R-014-01 IA C-C MT NDE 2.2-6 C X - - - 4/29/93 - MT COMPLETE INTEGRAL ATTACHHENTS C3.20 4pipu

    • N/A**

t ' I tl h )p N

I I

DATE: 08/11/93 TURKEY POINT NUCLEAR PLANT UNIT 4 REVISION: 3 INSERVICE INSPECTION

SUMMARY

SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (93RF)

CLASS 2 ALL STATUS COMPONENTS FEEDHATER BYPASS LOOP 8 N I 0 NUMBER: 115 ASME S ONGT SEC. XI T RSEH

SUMMARY

EXAHIHAT ION AREA CATGY EXAH A E I 0 E REHARKS NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE T C G H R **CALIBRATIONBLOCK**

SYSTEM NO. 74 5614-P-770-S SN. 2 OF 4 REF. DUG. NO. 4-859 290850 7884-R-014-02 F-B VT-3 NDE 4.3-65 C X - - - 4/21/93 - VT COMPLETE BOX RESTRAINT F2.10 40 IOII

  • ~N/A~*

290860 7884-R-014-02 IA C-C HT NDE 2.2-1 C X - - - 4/19/93 - MT COMPLETE INTEGRAL ATTACHMENTS C3.20 40'0"

    • N/A**

i II 1 : n

DATE: 08/11/93 TURKEY POINT NUCLEAR PLANT UNIT 4 REVISION: 3 INSERVICE INSPECTION SUHHARY SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (93RF)

CLASS 2 ALL STATUS COHPONENTS FEEDllATER BYPASS LOOP C N I 0 NUHBER: 1'16 ASHE S ONGT SEC. XI T RSEH SUHMARY EXAHINATION AREA CATGY EXAM A E I 0 E REHARKS NUHBER IDENT IF ICATION ITEH NO METHOD PROCEDURE T C G H R **CALIBRATIONBLOCK**

SYSTEH NO. 74 5614-P-770-S SN. 1 OF 4 REF. DUG. NO. 4-B60 291600 7884-R-014-03 F-B VT-3 NDE 4.3-66 C X . - - 4/21/93 - VT COHPLETE BOX RESTRAINT F2.10 40 I 0 I I 4*N/A*A 291610 7884-R-014-03 IA C-C HT NDE 2.2-2 C X - - - 4/19/93 - HT COHPLETE INTEGRAL ATTACHMENTS C3.20 40'04

    • N/A4*

II

'gh 4

DATE: 08/11/93 TURKEY POINT NUCLEAR PLANT UNIT 4 PAGE: 63 REVISION: 3 INSERVICE INSPECTION

SUMMARY

SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (93RF)

CLASS 2 ALL STATUS COMPONENTS IDUAL HEAT EXCHANGER A N I 0 NUMBER: 117 ASME S ONGT SEC. XI T RSEH

SUMMARY

EXAMINATION AREA CATGY EXAH A E I 0 E REHARKS NUMBER IDENT IF ICATION ITEM NO METHOD PROCEDURE T C G H R **CALIBRATIONBLOCK**

REF. DNG. NO. 4-V14A 292400 4-RHE-A1 C-A UT 45 NDE 5.4-5 C - - X - 4/24/93 - UT COMPLETE, ROOT GEOMETRY HEAD TO SHELL O'I ~ 20 UT 60 NDE 5.4-5 X - --

    • UT 55**

292500 4-RHE-A2 C-A UT 45 NDE 5.4-5 C - - X - 2/24/93 - UT COMPLETE, ROOT GEOMETRY AND SHELL TO FLANGE C1.10 UT 60 NDE 5.4-5 - X - NELDED ATTACHMENT ON THE INSIDE SURFACE

    • UT 554*

292630 4-RHE-A9 C-B PT NDE 3.3-11 C X - - - 4/23/93 - PT COMPLETE REINFORCEMENT PLATE TO SHELL C2.31

    • N/A**

0 4-RHE-A10 C-B PT NDE 3.3-11 C X - - - 4/23/93 - PT COMPLETE REINFORCEMENT PLATE TO NOZZLE C2.31

~*N/A**

k 0

k

'l

DATE: 08/'11/93 TURKEY POINT NUCLEAR PLANT UNIT 4 PAGE: 64 REVISION: 3 IHSERVICE INSPECTION

SUMMARY

SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (93RF)

CLASS 2 ALL STATUS COMPONENTS SS LETDOWN HEAT EXCHANGER H I 0 E NUMBER: 119 ASME S OHGT SEC. XI T RSEH

SUMMARY

EXAMINATION AREA CATGY EXAM A E I 0 E REMARKS NUHBER IDEHT IF I CAT ION ITEM HO METHOD PROCEDURE T C G M R <<*CALIBRATIOH BLOCK**

ATLAS SERIAL NO. 846 NATIONAL BOARD NO. 697 REF. DWG. NO. 4-V15 293700 4-LDHX-2 C-A UT 45 NDE 5.4-7 C - - X - 4/27/93 - UT COMPLETE, ROOT GEOMETRY, SHELL TO FLANGE C1.30 UT 60 NDE 5.4-7 - X - 'WELD ATTACHMENT, ROOT GEOMETRY FROM LONG CTMT SEAM

<<UT.41<<<<

293750 4-LDHX-2LS UT 45 NDE 5.4-7 C - - X - 4/27/93 - UT COMPLETE, ROOT GEOMETRY, LOHGITUDINAL SEAM WELD WAS FOUND DURING EXAMINATION OF CTMT CIRCUMFERENTIAL WELD

    • UT 41**

l v

, ~ g 7

DATE: 08/11/93 TURKEY POINT NUCLEAR PLANT UNIT 4 PAGE: 65 REVISIOH: 3 IHSERVICE INSPECTION

SUMMARY

SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (93RF)

CLASS 3 ALL STATUS COMPONENTS ONEHT COOLING 'HATER INSIDE CONTAINMENT N I 0 E NUMBER: 120 ASME S ONGT SEC. XI T RSEH

SUMMARY

EXAMINATION AREA CATGY EXAM A E I 0 E REMARKS NUMBER IDENT IF I CAT ION ITEM HO METHOD PROCEDURE T C G M R **CALIBRATIONBLOCK**

SYSTEM HO. 30 5614-P-536-S SH. 1 OF 4 REF. DNG. NO. 4-C01 293800 4-ACH-150 F-B VT-3 NDE 4.3-47 C X - - - 4/16/93 - VT COMPLETE PIPE SUPPORT F2.10 CTMT, 17'0"

    • H/A**

293850 4-ACH-150 IA D-A VT-3 NOE 4.3-48 C X - - - 4/16/93 - VT COMPLETE INTEGRAL ATTACHMENT D1.20 CTMT, 17'0"

    • H/A**

294000 4-120-A1 F-B VT-3 HDE 4.3-49 C X - - - 4/16/93 - VT COMPLETE ANCHOR F2 '0 CTMT, 21'0"

    • M/A**

50 4-120-A1 IA D-A VT-3 HDE 4.3-50 C X - - - 4/16/93 - VT COMPLETE INTEGRAL ATTACHHENT D1 ~ 20 CTMT, 21'0"

    • H/A**

I I J II II

'I II

DATE: 08/11/93 TURKEY POINT NUCLEAR PLANT UNIT 4 PAGE: 66 REVISIOH: 3 IHSERVICE INSPECTION

SUMMARY

SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (93RF)

CLASS 3 ALL STATUS COHPONENTS PONENT COOLING HATER INSIDE CONTAINMENT H I 0 NUMBER: 121 ASME S ONGT SEC. XI T RSEH

SUMMARY

EXAHINATIOH AREA CATGY EXAM A E I 0 E REMARKS NUHBER IDENT I F I CATION ITEH NO METHOD PROCEDURE T C G M R **CALIBRATIONBLOCK**

SYSTEM NO. 30 5614-P-535-S SH. 1 OF 3 REF. DUG. NO. 4-C02 294100 4-12'I-A'I F-B VT.3 NDE 4.3.51 C X - - - 4/16/93 - VT COMPLETE ANCHOR F2.10 CTHT, 21'0"

'A*N/At*

294150 4-121-A1 IA 0-A VT-3 NDE 4.3-52 C X - - - 4/16/93 - VT COMPLETE INTEGRAL ATTACHHEHT D1.20 CTHT, 21'0"

~*N/A**

294450 4-ACH-124 F-C VT-3 NDE 4.3-41 C X - - - 4/16/93 - VT COMPLETE SPRING SUPPORT F3.50 VT-4 CTHT, 17'0"

    • N/A**

460 4-ACH-124 IA D-A VT-3 NDE 4.3-42 C X - - - 4/16/93 - VT COMPLETE INTEGRAL ATTACHMEHT D1.40 CTMT, 17'04

<<*N/A**

294500 4-ACH-125 F-B VT-3 NDE 4.3-43 C X - - - 4/16/93 - VT COMPLETE BOX RESTRAINT F2.10 CTMT, 17'0" k*N/A**

294550 4-ACH-125 IA D-A VT-3 NDE 4.3-44 C X - - - 4/16/93 - VT COMPLETE INTEGRAL ATTACHHENT D1.20 CTMT, 17'0"

    • N/A**

I t p f

~ P h h

0

~ F p g lt

/( I I

1

DATE: 08/11/93 TURKEY POINT NUCLEAR PLANT UNIT 4 PAGE 67 REVISION: 3 INSERVICE IHSPECTION

SUMMARY

SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (93RF)

CLASS 3 ALL STATUS COHPONEHTS OHEHT COOLING MATER SYSTEM TO CCM PUMPS A & B N I 0 NUHBER: 123 ASME S ONGT SEC. XI T RSEH SUHHARY EXAMINATION AREA CATGY EXAH A E I 0 E REHARKS NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE T C G M R "*CALIBRATION BLOCK**

SYSTEM NO. 30 5614-P-518-S SH. 8 & 9 OF 10 REF. DWG. NO. 4-C04 295900 SR.686 F-B VT-3 NDE 4.3-2 C X - - - 4/14/93 - VT COHPLETE ANCHOR F2.10 30 I 2ll

    • N/A**

295950 SR-686 IA D-B VT-3 NDE 4.3-3 C X - - - 4/14/93 - VT COHPLETE INTEGRAL ATTACHHENT D2.20 30 I 2l I

    • N/A**

W II 4

DATE: 08/11/93 TURKEY POINT NUCLEAR PLANT UNIT 4 REVISIOH: 3 r INSERVICE INSPECTION

SUMMARY

SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (93RF)

CLASS 3 ALL STATUS COMPONENTS PONENT COOLING 'WATER FROM NON-REGENERATIVE HX N I 0 HUNGER: 125 ASME S ONGT SEC. XI T RSEH SUMHARY EXAHINATION AREA CATGY EXAM A E I 0 E REMARKS NUHBER IDENT IF I CATION ITEH NO METHOD PROCEDURE T C G M R **CALIBRATIONBLOCK**

SYSTEH NO. 30 5614-P-528-S SH. 2 OF 2 REF. DUG. NO. 4-C06 296700 4.ACH-216 F-C VT-3 NDE 4.3-9 C X - - - 4/'14/93 - VT COMPLETE SLIDING STANCHION F3.10 19 I 6ll

    • N/A*+

296750 4-ACH-216 IA D-A VT-3 NDE 4.3-10 C X - - - 4/14/93 - VT COMPLETE INTEGRAL ATTACHHEHT D1.20 19 I 6II

'k*N/A**

296800 4-ACH.217 F-C VT-3 NDE 4.3-11 C X - - - 4/14/93 - VT COMPLETE SLIDING STANCHION F3.10 19 I 6II

    • N/A**

50 4-ACH-217 IA D-A VT-3 NDE 4.3-14 C X . - . 4/14/93 - VT COMPLETE INTEGRAL ATTACHHEHT D1.20 19I6II

%AN/AA*

4 I'

DATE: 08/11/93 TURKEY POINT NUCLEAR PLANT UNIT 4 PAGE: 69 REVISION: 3 IHSERVICE INSPECTION

SUMMARY

SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (93RF)

CLASS 3 ALL STATUS COMPONENTS OHENT COOLING WATER FROM RHR HEAT EXCHANGER N I 0 NUMBER: 126 ASME S OHGT SEC. XI T RSEH

SUMMARY

EXAMINATION AREA ,CATGY EXAM A E I 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE T C G M R **CALIBRATIONBLOCK**

SYSTEM HO. 30 5614-P-518-S SH. 4 OF 10 REF. DWG. NO. 4-C07 297700 4-ACH-11 F-C VT-3 NDE 4.3-19 C - - - X 4/14/93 - VT COMPLETE( PAINT ON RIGID STRUT F3.10 VT-3 HDE 4.3-93 X - - - SPHERICAL BEARIHGSI 5/20/93 - VT 1510,I CHR 93-4-010 RE-EXAMINATION COMPLETE CR 93-232 PWO 93007052 **N/A4*

297750 4-ACH-11 IA D-B VT-3 NDE 4.3-20 C - - - X 4/14/93 - VT COMPLETE, WELDS OH IHTEGRAL ATTACHMENT D2 ~ 20 CNR 93-4-011 INTREGRAL ATTACHMENT DIFFERENT FROM 15'0" CR 93-231 DRAWING, ACCEPTED AS-IS BY EHGIHEERIHG EVALUATION, DRAWING WILL BE UPDATED TO SHOW 'WELD CONFIGURATION

    • H/A**

II '

DATE: 08/11/93 TURKEY POINT NUCLEAR PLANT UNIT 4 REVISION: 3 INSERVICE INSPECTION

SUMMARY

SECOHD INTERVAL, THIRD PERIOD, SECOND OUTAGE (93RF)

CLASS 3 ALL STATUS COHPONENTS ONENT COOLING HATER SYSTEM OUTSIDE CON N I 0 E NUMBER: 127 ASHE S ONGT SEC. XI T RSEH SUHHARY EXAMINATION AREA CATGY EXAM A E I 0 E REHARKS HUNGER IDENTIFICATION ITEM NO METHOD PROCEDURE T C G M R **CALIBRATIONBLOCK**

SYSTEH NO. 30 5614-P-518-S SH. 6 OF 10 REF. DWG. NO. 4-COB 298300 4-ACH-64 F-C VT-3 NDE 4.3-25 C X - - - 4/15/93 - VT COMPLETE SLIDIHG STAHCHIOH F3.10 13'64

    • N/A**

298350 4-ACH-64 IA D-B VT-3 HDE 4.3-26 C X - - - 4/15/93 - VT COMPLETE INTEGRAL ATTACHMENT 02.20 13'6"

    • N/A**

298400 4-ACH-56 F-C VT-3 HDE 4.3-23 C X - - - 4/15/93 - VT COMPLETE SLIDING STANCHION F3.10 13 I 6ll

    • N/A**

50 4-ACH-56 IA D-8 VT.3 NDE 4.3-24 C X - - - 4/15/93 - VT COMPLETE INTEGRAL ATTACHHENT D2.20 13'6"

    • N/A**

298500 4-ACH-55 F-C VT-3 NDE 4.3-21 C X - - - 4/15/93 - VT COMPLETE SLIDING STANCHION F3.10 13 I6II

    • N/A**

298550 4-ACH-55 IA D-8 VT-3 NDE 4.3-22 C X - - - 4/15/93 - VT COMPLETE INTEGRAL ATTACHHENT D2.20 13'6"

    • N/A**

C DATE: 08/11/93 TURKEY POINT NUCLEAR PLANT UNIT 4 REVISION: 3 INSERVICE IHSPECTIOH

SUMMARY

SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (93RF)

CLASS 3 ALL STATUS COMPONENTS PONENT COOLING WATER SYSTEH OUTSIDE CONTAINMENT N I 0 NUMBER: 129 ASHE S ONGT SEC. XI T RSEH SUHHARY EXAHI NATION AREA CATGY EXAM A E I 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE T C G M R **CALIBRATIONBLOCK**

SYSTEM NO. 30 5614-P-526-S SH. 5 OF 5 REF. DWG. NO. 4-C10 299500 4-ACH-52 F-B VT-3 NDE 4.3-28 C X - - - 4/15/93 - VT COMPLETE SLIDIHG STANCHION F2.10

'11'2"

    • N/A**

299600 4-ACH-52 IA D-B VT-3 NDE 4.3-29 C X - - - 4/15/93 - VT COHPLETE INTEGRAL ATTACHHENT D2.20 11'2"

    • N/A'kA'

4 J CI lg '

r j

h 1

DATE: 08/11/93 TURKEY POINT HUCLEAR PLANT UNIT 4 REVISION: 3 INSERVICE INSPECTION

SUMMARY

SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (93RF)

CLASS 3 ALL STATUS COMPONENTS PONENT COOLING WATER TO SEAL WATER 8 NON-REG.HX N I 0 NUMBER: 131 ASME S ONGT SEC. XI T RSEH SUHMARY EXAMINATION AREA CATGY EXAM A E I 0 E REMARKS NUMBER IDENTIFICATION ITEH NO METHOD PROCEDURE T C G M R **CALIBRATIONBLOCK**

SYSTEM NO. 30 5614-P-526-S SH. 3 OF 5 REF. DWG. NO. 4-C13 300200 SR-702 F-C VT-3 NDE 4.3-30 C X - - - 4/14/93 - VT COMPLETE ANCHOR F3.10 30 I3II

    • N/A~*

300250 SR-702 IA D-8 VT-3 NDE 4.3-31 C X - - - 4/14/93 - VT COMPLETE IHTEGRAL ATTACHMENT D2.20 30 I 3 I I

    • N/A**

SYSTEM NO. 30 5614-P-523-S SH. 2 OF 2 REF. DWG. HO. 4-C13 300500 4-ACH-225 F-C VT-3 NDE 4.3-32 C X - - - 4/14/93 - VT COMPLETE SLIDING STANCHIOH F3.10 18'9"

    • N/A**

550 4-ACH-225 IA 0-B VT-3 NDE 4.3-33 C X - - - 4/14/93 - VT COMPLETE INTEGRAL ATTACHHENT D2.20 1819ll

    • N/A**

4 ,

I

DATE: 08/11/93 TURKEY POINT NUCLEAR PLANT UNIT 4 PAGE: 73 REVISION: 3 IHSERVICE INSPECTION

SUMMARY

SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (93RF)

CLASS 3 ALL STATUS COMPONENTS ONENT COOL NG lJATER SYSTEM OUTSIDE CONTAINMENT N I 0 NUMBER: 132 ASHE S ONGT SEC. XI T RS EH

SUMMARY

EXAMINATION AREA CATGY EXAM A E I 0 E REMARKS NUHBER IDENT I F ICATION ITEH HO METHOD PROCEDURE T C G M R **CALIBRATIONBLOCK**

SYSTEM NO. 30 5614-P-526-S SH. 3 OF 5 REF. DMG. NO. 4-C14 300600 4-ACH.212 F-C VT-3(4 NDE 4.3-88 A X 5/6/93 VT COMPLETE g IMPROPER SPRING SPRING HANGER F3.50 CNR 91.4-011 CAN SETTINGS, RE-EXAHINATION AFTER 32'2" PWO 910207105639 CORRECTION OF DISCREPENCIES NOTED IN CNR 9'I-4-011

<<*N/A*a

'I 0

DATE: 08/11/93 TURKEY POINT NUCLEAR PLANT UNIT 4 PAGE: 74 REVISION: 3 INSERVICE INSPECTION

SUMMARY

SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (93RF)

CLASS 3 ALL STATUS COMPONENTS ONENT COOLING IIATER FROM CCM HEAT EXCHANGERS N I 0 NUMBER: 133 ASME S ONGT SEC. XI T RSEH

SUMMARY

EXAMINATION AREA CATGY EXAM A E I 0 E REMARKS NUMBER IDENT IF I CAT ION ITEM NO METHOD PROCEDURE T C G M R <<*CALIBRATION BLOCK**

SYSTEM NO. 30 5614-P-526-S SH. 2 OF 5 REF. DN. NO. 4-C15A 301500 SR-693 F-C VT-3,4 NDE 4.3-12 C - - - X 4/14/93 - VT COMPLETE, MISSING LOAD SPRING HANGER F3 '0 CHR 93.4-003 PLATE, ACCEPTED AS-IS BY ENGINEERING 32'2" CR 93-237 EVALUATION

    • H/A**

301600 SR-693 IA D-8 VT-3 HDE 4.3-13 C X - - - 4/14/93 - VT COMPLETE INTEGRAL ATTACHMENT D2 ~ 20 32 I 2 I I

    • N/A**

SYSTEM NO. 30 5614-P-526-S SH. 1 OF 5 REF. DlJG. NO. 4-C15A 302700 SR-697 F-B VT-3 NDE 4.3-36 C X - - - 4/15/93 - VT COMPLETE SLIDIHG STANCHION F2.10 11 I6II A*N/A*A 2750 SR-697 IA D-8 VT-3 HDE 4.3-37 C X - - - 4/15/93 - VT COMPLETE INTEGRAL ATTACHMENT D2.20 1'1 '64

    • N/A%*

302800 4-ACH-214 F-8 VT-3 NDE 4.3-38 C X - - - 4/15/93 - VT COMPLETE SLIDING STAHCHION F2.10 1 1 6II I

    • H/A~*

302850 4-ACH.214 I A D-8 VT-3 NDE 4.3-39 C X - - - 4/15/93 - VT COMPLETE INTEGRAL ATTACHMENT D2.20 11'6"

%*N/A**

\II 8

Ai E'

DATE: 08/11/93 TURKEY POINT NUCLEAR PLANT UNIT 4 PAGE: 75 REVISION: 3 IHSERVICE INSPECTION

SUMMARY

SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (93RF)

CLASS 3 ALL STATUS COMPONENTS PONENT COOLING 'WATER TO RESIDUAL NX A & B H I 0 NUMBER: 134 ASME S ONGT SEC. Xl T RSEH

SUMMARY

EXAMINATION AREA CATGY EXAM A E I 0 E REMARKS NUMBER IDENTIFICATION ITEM HO METHOD PROCEDURE T C G M R **CALIBRATIOHBLOCK**

SYSTEM NO. 30 5614-P-526-S SH. 4 OF 5 REF. DWG. NO. 4-C16 303100 4-ACH-13 F-C VT-3 NDE 4.3-15 C - - - X 4/14/93 - VT COMPLETE, PAIHI'N DUAL ROD HANGER F3.'IO VT-3 NDE 4.3-91 X - - - SPHERICAL BEARING) PAINT WAS REMOVEDI 15'0" CHR 93-4-006 5/20/93 - V'I RE-EXAMINATION COMPLETE CR 93-234 PWO 93007050 **H/A**

303150 4.ACH-13 IA D-B VT-3 NDE 4.3-18 C - - - X 4/14/93 - VT COMPLETE, INTEGRAL INTEGRAL ATTACHMENT D2.10 CHR 93-4-009 ATTACHMENT NOT WELDED AS SHOWN ON 15'0" CR 93-233 DRAWING, ACCEPTED AS-IS BY ENGINEERING EVALUATION

    • N/A**

DATE: 08/11/93 TURKEY POINT NUCLEAR PLANT UNIT 4 REVISION? 3 INSERVICE INSPECTION

SUMMARY

SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (93RF)

CLASS 3 ALL STATUS COMPONENTS PONEHT COOLING WATER SYSTEM OUTSIDE CONTAIHMENT N I 0 NUMBER: 136 ASME S OHGT SEC. XI T RSEM SUHMARY EXAMINATION AREA CATGY EXAM A E I 0 E REMARKS HUHBER IDENTIFICATION ITEM NO METHOD PROCEDURE T C G M R **CALIBRATIONBLOCK**

SYSTEH NO. 30 5614-P-518-S SH. 5 OF 10 REF. DWG. NO. 4-C18 304000 4-CCH-2 F-C VT-3 NDE 4.3-64 C X - - - 4/20/93 - VT COMPLETE ROD HANGER F3 '0 29 I 9 II

    • N/A**

304050 4-CCH-2 IA D-8 VT-3 NDE 4.3-64 C X - - - 4/20/93 - VT COMPLETE INTEGRAL ATTACHMENT 02 '0 29'9"

    • N/A**

9 , f j E,s II ld t

DATE: 08/11/93 TURKEY POINT NUCLEAR PLANT UNIT 4 REVISION: 3 INSERVICE INSPECTION

SUMMARY

SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (93RF)

CLASS 3 ALL STATUS COHPONENTS PONENT COOLING WATER SYSTEM OUTSIDE CONTAINHENT N I 0 NUHBER: 137 ASHE S ONGT SEC. XI T RSEH SUMHARY EXAHINATION AREA CATGY EXAM A E I 0 E REMARKS NUHBER IDENT I F I CAT ION ITEH NO HETHOO PROCEDURE T C G H R **CALIBRATIONBLOCK**

SYSTEM NO. 30 5614-P-527-S SH. 1 OF 2 REF. D'WG. NO. 4-C19 304100 SR-710 F-C VT-3 NDE 4.3-34 C X - - - 4/15/93 - VT COMPLETE ANCHOR F3.10 11 I6ll

    • N/A**

304150 SR-710 IA D-B VT-3 NDE 4.3.35 C X - - - 4/15/93 - VT COHPLETE INTEGRAL ATTACHMENT D2.20 11'6"

    • N/A**

l E ~ ~

DATE: 08/11/93 TURKEY POINT NUCLEAR PLANl'NIT 4 PAGE: 78 REVISION: 3 INSERVICE INSPECTION

SUMMARY

SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (93RF)

CLASS 3 ALL STATUS COMPONENTS PONENT COOLING WATER TO RNR HEAT EXCHANGER A H I 0 NUMBER: 140 ASHE S OHGT SEC. XI T RSEH SUHHARY EXAMINATION AREA CATGY EXAM A E I 0 E REMARKS NUHBER IDENT IF I CAT ION ITEM NO METHOD PROCEDURE T C G M R **CALIBRATIONBLOCK~*

SYSTEM NO. 30 5614-P-526-S SH. 1 OF 5 REF. DWG. NO. 4-C22 306600 4-ACH-14 F-C VT-3 NDE 4.3-17 C - - - X 4/'14/93 - PAINT ON SPHERICAL BEARINGS, DUAL ROO HANGER F3.10 VT-3 NDE 4.3-94 X - - - PAINT REMOVED, 5/20/93 - VT 15'0" CNR 93-4-008 RE-EXAHINATION COMPLETE CR 93-235 PWO 93007051 **N/A**

306650 4-ACH-14 IA D-8 VT-3 NDE 4.3-16 C - - - X 4/14/93 - VT COMPLETE, DRAWING INTEGRAL ATTACHHENT D2.10 CNR 93-4-007 DISCREPENCY, INTEGRAL ATTACHMENT NOT 15 I 0 II CR 93-236 WELDED AS SHOWN ON DRAWING, ACCEPTED AS-IS BY ENGINEERING EVALUATION

    • N/A**

1H

~ ~

'I

DATE: 08/11/93 TURKEY POINT NUCLEAR PLANT UNIT 4 PAGE: 79 REVISION: 3 INSERVICE INSPECTION

SUMMARY

SECOHD INTERVAL, THIRD PERIOD, SECOHD OUTAGE (93RF)

CLASS 3 ALL STATUS COMPOHEHTS POHENT COOLING HATER SYSTEM INSIDE CONTAINMENT N I 0 NUMBER: 141 ASME S ONGT SEC. Xl T RSEH

SUMMARY

EXAMINATION AREA CATGY EXAM A E I 0 E REMARKS HUHBER IDENTIFICATION ITEM NO METHOD PROCEDURE T C G M R **CALIBRATIOHBLOCK**

SYSTEM NO. 30 5614-P-539-S SH. 3 OF 3 REF. DMG. NO. 4-C23 306900 4-141-A1 F-8 VT-3 NDE 4.3-53 C X - - - 4/16/93 - VT COMPLETE ANCHOR F2.10 CTMT, 23'64

    • N/A**

306950 4-141-A1 IA D 8 VT-3 NDE 4.3-54 C X - - - 4/16/93 - VT COMPLETE INTEGRAL ATTACHHEHT 82.20 CTMT, 23'6"

%IN/A**

307000 4-CCH-34 F-8 VT-3 NDE 4.3-45 C X - - - 4/16/93 - VT COMPLETE BOX RESTRAINT F2. 10 CTMT, 34'8"

    • N/A**

040 4-CCH-34 IA D-B VT-3 NDE 4.3-46 C X - - - 4/16/93 - VT COMPLETE INTEGRAL ATTACHMENT D2.20 CTMT, 34'84

    • N/A~~

DATE: 08/11/93 TURKEY POINT NUCLEAR PLANT UNIT 4 PAGE: 80 REVISION: 3 INSERVICE INSPECTION

SUMMARY

SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (93RF)

CLASS 3 ALL STATUS COMPONENTS POHEHT COOLING WATER SYSTEM FROM CCW PUMP C H I 0 NUMBER: 15'I ASME S ONGT SEC. XI T RSEH

SUMMARY

EXAMINATION AREA CATGY EXAM A E I 0 E REMARKS NUMBER IDENT I F I CAT ION ITEM NO METHOD PROCEDURE T C G M R **CALIBRATIONBLOCK**

SYSTEM HO. 30 5614-P-501-S SH. 3 OF 3 REF. DWG. NO. 4-C33 314200 4-ACH-182 F-C VT-3(4 HDE 4.3-87 A - - - X 5/6/93 - VT COMPLETE, SPRING CAH SCALE DUAL SPRING HANGER F3.50 CHR 91-4-022 ILLEGIBLE, RE-EXAMINATION AFTER 32l2ll PWO 910207111504 CORRECTION OF ITEMS FOUND IN CHR 91-4-022

    • H/A**

'I 0

V I 'I h

l

DATE: 08/11/93 TURKEY POINT NUCLEAR PLANT UNIT 4 PAGE: 81 REVISION: 3 INSERVICE INSPECTION

SUMMARY

SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (93RF)

CLASS 3 ALL STATUS COMPONENTS PONEHT COOLING WATER SYSTEM OUTSIDE CONTAINMENT N I 0 NUMBER: 154 ASME S ONGT SEC. XI T RSEH SUMHARY EXAMINATION AREA CATGY EXAM A E I 0 E REMARKS NUMBER IDENT I F I CAT ION ITEM NO METHOD PROCEDURE T C G M R **CALIBRATIOHBLOCK**

SYSTEM NO. 30 5614-P-518-S SH ~ 5 OF 10 REF. DWG. NO. 4-C36 317300 4-CCH-3 F-C VT-3 NDE 4.3-4 C - - - X 4/14/93 - VT COMPLETE, PAINT ON RIGID STRUT F3.10 VT-3 NDE 4.3-92 X - - - SPHERICAL BEARINGI PAINT REMOVED, 19 I3ll CNR 93-4-095 5/20/93 - VT RE-EXAMINATION COMPLETE CR 93-462

+*N/A**

317350 4-CCH-3 IA D-8 VT-3 NDE 4.3-5 C X - - - 4/14/93 - VT COMPLETE INTEGRAL ATTACHHENT D2.20 1 9 I 3ll

    • H/A**

SYSTEM NO. 30 5614-P-518-S SH. 10 OF 10 REF. DWG. NO. 4-C36 317600 4-ACH-43 F-C VT-3 HDE 4.3-40 C - - - X 4/14/93 - VT COMPLETE, PAINTED SPHERICAL DUAL RIGID STRUT F3.10 VT-3 NDE 4.3-90 X BEARING( BEARING RACE IS PARTIALLY 13'6" CHR 93-4-012 DISLODGED FROM STRUT, ACCEPTED AS-IS BY CR 93.229 ENGINEERING EVALUATION, WILL BE PWO 93007054 CORRECTED AT A FUTURE DATE UHDER A PLANT WORK ORDER, PAINT WAS REMOVED

    • H/A**

317650 4-ACH-43 IA D-8 VT-3 NDE 4.3-7 C X - - - 4/14/93 - VT COMPLETE INTEGRAL ATTACHMENTS D2.20 13'6"

    • H/A**

Jl ii, N,

DATE: 08/11/93 TURKEY POINT NUCLEAR PLANT UNIT 4 PAGE: 82 REVISION: 3 IHSERVICE INSPECTION

SUMMARY

SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (93RF)

CLASS 3 ALL STATUS COMPONENTS ILIARY FEEDUATER SYSTEM PUMP DISCHARGE H I 0 NUHBER: 160 ASME S ONGT SEC. XI T RSEH SUHMARY EXAMINATION AREA CATGY EXAM A E I 0 E REMARKS NUHBER IDEN'I I F I CATION ITEM HO METHOD PROCEDURE T C G M R **CALIBRATIOHBLOCK**

SYSTEM NO. 74 5614-P-807-S SH. 4 OF 7 REF. DUG. NO. 4 C42 322600 80117-A-324-01 F-C VT-3 NDE 4.3-55 C X - - - 4/16/93 - VT COMPLETE ANCHOR F3.10 36 I 0ll

    • N/A%*

322650 80117-A-324-01 IA D-8 VT-3 HDE 4.3-55 C X - - - 4/16/93 - VT COHPLETE INTEGRAL ATTACHHENT D2.20 36 I Pll

    • N/A**

322800 80117-H-324-07 F-C VT.3 HDE 4.3-56 C X - - - 4/16/93 - VT COMPLETE PIPE SUPPORT F3.10 36 I Oll

    • H/A**

850 80117-H-324-07 IA D-8 VT-3 NDE 4.3-56 C X - - - 4/16/93 - VT COMPLETE INTEGRAL ATTACHHENT 02 '0 36 I 0 II

    • N/A**

IP

DATE: 08/11/93 TURKEY POINT NUCLEAR PLANT UNIT 4 PAGE: 83 REVISION: 3 INSERVICE INSPECTION

SUMMARY

SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (93RF)

CLASS 3 ALL STATUS COMPONENTS ILIARY FEEDilATER SYSTEM PUMP DISCHARGE H I 0 NUMBER: 161 ASHE S ONGT SEC. XI T RSEH

SUMMARY

EXAMINATION AREA CATGY EXAM A E I 0 E REHARKS NUMBER IDENTIFICATION ITEM HO METHOD PROCEDURE T C G M R **CALIBRATIONBLOCK**

SYSTEM HO. 74 56'14-P-807-S SH. 4 OF 7 REF. DUG. HO. 4-C43 323250 80117 H-324-11 F-C VT-3 NDE 4.3-57 C X - - - 4/16/93 - VT COMPLETE BOX RESTRAINT F3 '0 32 I 2II

    • N/A**

323275 80117-H-324-11 IA D-B VT-3 HDE 4.3-57 C X - - - 4/16/93 - VT COMPLETE INTEGRAL ATTACHMENT D2.20 32'2"

    • H/A**

323450 80117-H-324-13 F-C VT-3 HDE 4.3-58 C X - - - 4/16/93 - VT COMPLETE BOX RESTRAINT F3.10 30 I 3 II

    • N/A**

475 80117-H-324-13 IA D.B VT-3 NDE 4.3-58 C X - - - 4/16/93 - VT COMPLETE INTEGRAL ATTACHHENT D2.20 30 I 3 II

  • AN/A*"

DATE: 08/11/93 TURKEY POINT NUCLEAR PLANT UNIT 4 PAGE: 84 REVISION: 3 INSERVI CE INSPECTION

SUMMARY

SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (93RF)

CLASS 3 ALL STATUS COHPONENTS ILIARY FEEDWATER PUMP SUCTION FROM COND.STG.TK.

N I 0 NUHBER: 163 ASME S ONGT SEC. XI T R GEM SUHHARY EXAMINATION AREA CATGY EXAH A E I 0 E REHARKS NUMBER IDENTIFICATION ITEH NO METHOD PROCEDURE T C G H R **CALIBRATIONBLOCK**

SYSTEM NO 74 5610-P-818-S SH 3 OF 3 REF. DWG. NO. 4-C45A 325700 80117-H-341-23 F-B VT-3 NDE 4.3.62 C X - - - 4/20/93 - VT COMPLETE SLIDING STANCHION F2.10 20 I 7ll

    • N/A**

325750 80117- H-341-23 IA 0-A VT-3 NDE 4.3-62 C X - - - 4/20/93 - VT COMPLETE INTEGRAL ATTACHMENT D1.20 20'7"

    • N/A**

326050 80117-R-341-03 IA D-A VT-3 NDE 4.3-63 C X - - - 4/20/93 - VT COMPLETE INTEGRAL ATTACHMENT D1 ~ 20 29'10"

    • N/A**

00 80117- H-341-18 F-C VT-3 NDE 4.3-61 C - - - X 4/17/93 - VT COMPLETE, SUPPORT HAS ROD HANGER F3.10 CHR 93-4-023 DAMAGED INSULATION ON ADJACENT LINE, 30'10" CR 93-254 INSULATION MILL BE HODIFIED TO GIVE PQO 93012727 PROPER CLEARANCE

    • M/A**

326450 80117-H-341-18 IA D-A VT-3 NDE 4.3.61 C X - - - 4/17/93 - VT COMPLETE INTEGRAL ATTACHMENT 01.20 30'10"

    • N/A**

SYSTEM NO. 74 5610-P-818-S SH. 2 OF 3 REF. DUG. NO. 4-C45B 328100 80117- H-341-02 F-B VT-3 NDE 4.3-60 C X - - - 4/16/93 - VT COMPLETE SLIDING STANCHION F2.10 20'94

    • N/A"*

DATE: 08/11/93 TURKEY POINT NUCLEAR PLANT UNIT 4 PAGE: 85 REVI SION: 3 INSERVICE INSPECTION SUHMARY SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (93RF)

CLASS 3 ALL STATUS COMPONENTS ILIARY FEEDIJATER PUHP SUCTION FROM COND.STG.TK.

N I 0 NUMBER 163 ASME S OHGT SEC. XI T RSEH SUHMARY EXAMINATION AREA CATGY EXAH A E I 0 E REMARKS HUMBER IDENTIFICATION ITEH NO METHOD PROCEDURE T C G H R **CALIBRATIONBLOCK**

SYSTEM NO. 74 5610-P-818-S SH. 2 OF 3 REF. DMG. NO. 4-C458 328150 80117-H-341-02 IA 0-A VT-3 NDE 4.3-60 C X - - - 4/16/93 - VT COMPLETE INTEGRAL ATTACHMENT 01.20 20 l9II

    • N/A**

328200 80117-H-341-01 F-8 VT-3 NDE 4.3-59 C X - - - 4/16/93 - VT COHPLETE SLIDING STANCHION F2.10 20 I 911

    • N/A**

328210 80117-H-341-01 IA D-A VT-3 NDE 4.3-59 C X - - - 4/16/93 - VT COMPLETE INTEGRAL ATTACHHENT D1.20 20 l9ll

    • N/A**

TURKEY POINT UNIT 4 1993 REFUELING OUTAGE Summary of Visual Examinations and Functional Testing of Snubbexs

e TABLE OF CONTENTS ABSTRACT ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ o ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ 3 PROCEDURES....................... ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ 4 EXAMINATION/TESTING.............. ~ o ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ o ~ ~ ~ ~ ~ ~ ~ 5 CONCLUSION........... ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ 14 ACRONYM LIST................................................... 16

ABSTRACT Visual examination and functional testing of Mechanical Shock Arrestors were performed on Unit 4 to satisfy the requirements of ASME Section XI, 1980 Edition, Winter 1981 Addenda and Plant Technical Specifications during the 1993 Refueling Outage. Visual Examination and Functional Testing activities were performed by Siemens Nuclear Power Services, Inc. during the period of April 21, 1993 through May 18, 1993.

PROCEDURES The following Florida Power & Light procedures were used to implement the Mechanical Shock Arrestor Surveillance Program.

AP 0190.83 Mechanical Shock Arrestor Surveillance Program AP 0190.85 Functional Testing of Mechanical Shock Arrestors OP 0209.9 Visual Examination of Mechanical Shock Arrestors O-CMM-105.1 Removal and Reinstallation of Mechanical Shock Arrestors The following procedures were utilized by Siemens Nuclear Power Services, Inc. to perform the Visual Examination and Functional Testing.

SNPS Quality Assurance Manual Rev. 14 SNPS-PP-3319-TPN Project Plan SNPS-CAL-2.2, Rev. 0 Daily Verification of Test Equipment SNPS-,CAL-1.2, Rev. 1 Daily Verification of Test Equipment SNPS-EXM-1.1, Rev. 0 Visual Examination of MSA's SNPS-TST-1.1, Rev. 0 Functional Testing of PSA MSA's SNPS-MNT-3.1, Rev. 0 Disassembly and Repair of PSA MSA's

Examination Testin Visual examination (VT-3, VT-4 hand stroke) were performed on a total of ninety one (91) snubbers and functional testing was performed on thirty (30) snubbers.

TAG'ERIAL MODEL SYSTEM FT TEST SAMPLE CORRECTIVE ACTION 4

1000 184 PSA-10 SIS SAT NONE 4-1001 18010 PSA-1 SIS SAT NONE 4-1002 18016 PSA-1 SIS SAT NONE 4-1003 18008 PSA-1 SIS SAT NONE 4- SEE DEV.

SUMMARY

1004 3168 PSA-35 MS SAT 2-93-PTN-4-1004 4- SEE DEV.

SUMMARY

1005 1206 PSA-35 MS SAT 4-93-PTN-4-1005 4- EXP. SAMPLE SEE DEV.

SUMMARY

1006 8087 PSA-35 MS SAT 3-93-PTN-4-1006 4- SEE DEV.

SUMMARY

1007 11928 PSA-35 MS SAT 1-93-PTN-4-1007 4- EXP. SAMPLE 1008 1205 PSA-35 "

MS SAT SAT 83 4- SEE DEV.

SUMMARY

1009 1228 PSA-35 MS SAT 5-93-PTN-4-1009 4- SEE DEV.

SUMMARY

1010 1204 PSA-35 MS SAT 7-93-PTN-4-1010 4- EXP. SAMPLE SEE DEV.

SUMMARY

1011 1281 PSA-35 MS SAT SAT g3 6-93-PTN-4-1011 4-1012 16154 PSA-10 SAT NONE 4-1013 17418 PSA-3 SAT NONE 4-1014 17177 PSA-10 SAT NONE

0 TAG¹ SERIAL ¹ MODEL SYSTEM VT FT TEST SAMPLE CORRECTIVE ACTION 4-1015 117 PSA-10 SAT NONE 4 SEE DEV.

SUMMARY

1016 122 PSA-10 SAT 8-93-PTN-4-1016 4-1017 118 PSA-10 SAT NONE 4-1018 17420 PSA-3 SAT NONE 4-1019 17426 PSA-3 SAT NONE 4- EXP. SAMPLE 1020 27101 PSA-3 FW SAT SAT NONE 4

1021 128 PSA-3 FW SAT NONE 4- EXP. SAMPLE 1022 21381 PSA-3 FW SAT SAT ¹2 NONE 4-1032 3707 PSA-35 FW SAT NONE 4-1033 7001 PSA-35 FW SAT NONE 4-1034 16243 PSA-10 FW SAT NONE 4- ¹2 SEE DEV.

SUMMARY

1035 182 PSA-10 FW SAT UNSAT YES 11-93-PTN-4-1035 4- EXP. SAMPLE 1036 11461 PSA-10 FW SAT SAT ¹1 NONE 4-1037 11930 PSA-35 FW SAT SAT YES NONE 4-1038 29497 PSA-1/4 CVCS SAT NONE

TAG¹ SERIAL ¹ MODEL SYSTEM FT TEST SAMPLE CORRECTIVE ACTION

¹3 SEE DEV.

SUMMARY

1039 4589 PSA-35 MS SAT UNSAT YES 12-93-PTN-4-1039 4-1040 174 19 PSA-3 CVCS SAT NONE 4-1041 19721 PSA-3 CVCS SAT NONE 4-1042 19727 PSA-3 CVCS SAT NONE 4-1043 27099 PSA-3 CVCS SAT NONE 4-1044 3919 PSA-10 RCS SAT NONE 4-1045 3905 PSA-10 RCS SAT NONE 4-1046 187 PSA-10 RCS SAT NONE 4- EXP. SAMPLE 1047 185 PSA-10 RCS SAT SAT ¹1 NONE 4-1048 4251 PSA-10 RCS SAT NONE 4-1049 10169 PSA-10 RCS SAT NONE 4-1050 12374 PSA-10 RCS SAT NONE 4-1051 11125 PSA-10 RCS SAT NONE 4- EXP. SAMPLE 1052 16251 PSA-10 RCS SAT SAT ¹1 NONE 4-1053 11446 PSA-10 RCS SAT NONE

TAG¹ SERIAL MODEL SYSTEM VT FT TEST SAMPLE CORRECTIVE ACTION 4- ¹1 SEE DEV.

SUMMARY

1054 16253 PSA-10 RCS SAT UNSAT YES 10-93-PTN-4-1054 4- DEVIATION SEE DEV.

SUMMARY

1055 11110 PSA-10 RCS SAT SAT DISPOSITION 9-93-PTN-4-1055 4- INFO 1056 17841 PSA-10 RCS SAT SAT TEST NONE 4-1057 27080 PSA-3 RCS SAT NONE 4-1058 21379 PSA-3 RCS SAT NONE 4-1059 27103 PSA-3 RCS SAT NONE 4-1061 19722 PSA-3 RCS SAT NONE 4- EXP. SAMPLE 1062 27076 PSA-3 RCS SAT SAT ¹1 NONE 4-1063 27098 PSA-3 RCS , SAT NONE 4-1064 27077 PSA-3 RCS SAT SAT YES NONE 4-1065 20873 PSA-3 RCS SAT NONE 4-1066 27094 PSA-3 RCS SAT NONE 4

1067 27097 PSA-3 RCS SAT SAT YES NONE 4-1068 27085 PSA-3 RCS SAT NONE 4-1069 10033 PSA-35 FW SAT NONE

TAG¹ SERIAL ¹ MODEL SYSTEM VT FT TEST SAMPLE CORRECTIVE ACTION 4-1070 10036 PSA-35 FW SAT NONE 4-1071 11315 PSA-10 FW SAT NONE 4- EXP. SAMPLE 1072 16235 PSA-10 FW SAT SAT ¹2 NONE 4- EXP. SAMPLE 1073 3941 PSA-10 FW SAT SAT ¹2 NONE 4-1074 19298 PSA-3 FW SAT NONE 4-1075 19297 PSA-3 FW SAT NONE 4- EXP. SAMPLE 1076 24414A PSA-1 SG SAT SAT ¹1 NONE 4- EXP. SAMPLE SEE DEV.

SUMMARY

1077 18014 PSA-1 SG SAT SAT ¹2 13-93-PTN-4-1077 4-1078 24430A PSA-1 SG SAT NONE 4- EXP. SAMPLE 1079 23227 PSA-1 SG SAT SAT ¹1 NONE 4-1080 24431 PSA-1 SG SAT SAT YES NONE 4-1081 19295 PSA-3 SG SAT NONE 4 EXP. SAMPLE 1082 19296 PSA-3 SG SAT SAT ¹2 NONE 4-1083 24408A PSA-1 SAT SAT YES NONE 4- EXP. SAMPLE 1084 23229 PSA-1 SG SAT SAT ¹2 NONE

TAG'- SERIAL 8 MODEL SYSTEM VT FT TEST SAMPLE CORRECTIVE ACTION 1085 23229 PSA-1/4 CVCS SAT NONE 1086 12993 PSA-35 MS SAT NONE 4-1087 12994 PSA-35 MS SAT NONE 4

1088 12995 PSA-35 MS SAT NONE 4-1089 12996 PSA-35 MS SAT NONE 4-1090 12997 PSA-35 MS SAT NONE 4- SEE DEV.

SUMMARY

1091 12998 PSA-35 MS SAT 15-93-PTN-4-1091 4-1092 12999 PSA-35 MS SAT NONE 1093 17868 PSA-10 'S SAT NONE 4-1094 17869 PSA-10 MS SAT NONE 4- DEVIATION SEE DEV.

SUMMARY

1095 17870 PSA-10 SAT SAT DISPOSITION 19-93-PTN-4-1095 MS'S 4-1096 17871 PSA-10 SAT NONE 4 EXP. SAMPLE SEE DEV.

SUMMARY

1097 17872 PSA-10 MS SAT UNSAT g2 14-93-PTN-4-1097 4-1098 17873 PSA-10 MS SAT NONE 4-1099 17423 PSA-3 MS SAT SAT YES NONE 10

TAG/ SERIAL g MODEL SYSTEM VT FT TEST SAMPLE CORRECTIVE ACTION 4-1100 29498 PSA-1/4 WDS SAT SAT YES NONE DEVIATION REPORT

SUMMARY

~Ta ~ 4-1004 DEVIATION 4: 2-93-PTN-4-1004 Int.: 04/22/93 Closed: 04/27/93 CONDITION: 1) Spherical bearing partially dislodged.

2) Load pin holes in rear bracket and pipe attachment are elongated.

DISPOSITION: Condition Report generated CR NO.93-320. Bearing restaked and brackets replaced.

Tata ~ 4-1005 DEVIATION 4: 4-93-PTN-4-1005 Int.: 04/22/93 Closed: 04/26/93 CONDITION: 1) Load pin deformed.

2) Load pin holes in rear bracket and pipe attachment are elongated.

DISPOSITION: Condition Report generated CR NO.93-320. Load pin replaced and brackets replaced.

~Ta ~ 4-1006 DEVIATION g: 3-93-PTN-4-1006 Int.: 04/22/93 Closed: 04/26/93 CONDITION: Spherical bearing dislodged on snubber end.

DISPOSITION: Bearing restaked and verified freedom of movement IAW SNPS-MNT-3.1.

~Ta ~ 4-1007 DEVIATION g: 1-93-PTN-4-1007 Int.: 04/22/93 Closed: 04/26/93 CONDITION: Load pin deformed.

DISPOSITION: Replaced load pin IAW SNPS-MNT-3.1.

11

~Ta ~ 4-1009 DEVIATION g: 5-93-PTN-4-1009 Int.: 04/22/93 Closed: 04/26/93 CONDITION: Load pin hole on rear bracket is elongated.

DISPOSITION: Condition Report generated CR NO.93-320. Rear bracket replaced.

~aq ~ 4-1010 DEVIATION 4: 7-93-PTN-4-1010 Int.: 04/22/93 Closed: 04/26/93 CONDITION: 1) Spherical bearing dislodged on snubber end.

2) Load pin hole in rear bracket is elongated.
3) Rear bracket load pin is deformed.

DISPOSITION: Condition Report generated CR NO.93-320. Bearing restaked and rear bracket and pin replaced.

~Ta + 4-1011 DEVIATION 4: 6-93-PTN-4-1011 Int.: 04/22/93 Closed: 04/26/93 CONDITION: Load pin holes in the rear bracket and pipe attachment are elongated.

DISPOSITION: Condition Report generated CR NO.93-320. Brackets replaced.

~aq ~ 4-1016 DEVIATION g: 8-93-PTN-4-1016 Int.: 04/26/93 Closed: 04/26/93 CONDITION: Lack of thread engagement between snubber and transition tube assembly.

DISPOSITION: Condition Report generated CR NO.93-341. Bolts replaced providing adequate thread engagement.

12

Tata ~ 4-1035 DEVIATION g: 11-93-PTN-4-1035 Int.: 05/Ol/93 Closed: 05/10/93 CONDITION: MSA exceeded the 0.02G specified criteria for acceleration.

DISPOSITION: Replaced MSA with tested spare S/N 11439.

~Ta ~ 4-1039 DEVIATION 5: 12-93-PTN-4-1039 Int.: 05/02/93 Closed: 05/07/93 CONDITION: 1) MSA has damaged spherical bearing.

2) MSA exceeded the 0.02G specified criteria for acceleration DISPOSITION: Replaced MSA with tested spare S/N 6998.

~Ta ~~ 4-1054 DEVIATION g: 10-93-PTN-4-1054 Int.: 05/01/93 Closed: 05/07/93 CONDITION: MSA exceeded the specified 0.02G acceleration criteria.

DISPOSITION: Replaced MSA with tested spare S/N 15718.

~aca ~ 4-1055 DEVIATION g: 9-93-PTN-4-1055 Int.: 04/27/93 Closed: 05/07/93 CONDITION: Snubber could not be hand stroked through it's full range.

DISPOSITION: Replaced MSA with tested spare S/N 7782. Functional tested removed MSA, test sat.

~Ta ~ 4-1077 DEVIATION 4: 13-93-PTN-4-1077 Int.: 05/03/93 Closed: 10/7/92 CONDITION: "L" dimension is less than the specified minimum.

DISPOSITION: Condition Report generated CR NO.93-385. Attachment moved to reestablish proper "L" dimension.

13

Taca ~ 4-1091 DEVIATION 5: 15-93-PTN<<4-1091 Int.: 05/04/93 Closed: 05/07/93 CONDITION: Load pin hole on pipe attachment is elongated.

DISPOSITION: Condition Report generated CR NO.93-320. Bracket replaced.

~Ta + 4-1095 DEVIATION g: 19-93-PTN-4-1095 Int.: 05/04/93 Closed: 05/10/93 CONDITION: Inspector unable to hand stroke this MSA.

DISPOSITION: MSA was functional tested sat.

Taca ~~ 4-1097 DEVIATION g: 14-93-PTN-4-1097 Int.: 05/03/93 Closed: 05/07/93 CONDITION: MSA exceeded the 750 5 Final Drag criteria.

DISPOSITION: Replaced MSA with tested spare S/N 17852.

CONCLUSION During the 1993 Refueling Outage, snubber surveillances were performed on the snubber population of Turkey Point Unit 4 in accordance with AP 0190.83 (Mechanical Shock Arrestor Surveillance Program). These surveillances included visual examinations and hand stroking of all Unit 4 snubbers in accordance with OP 0209.9 (Visual Examination of Mechanical Shock Arrestors). The functional test representative sample, and additional selections were tested and selected in accordance with AP 0190.85 (Functional Testing of Mechanical Shock Arrestors).

All functional tests and visual examinations were performed in compliance with ASME Section XI and the surveillance requirements of Plant Technical Specifications (3/4.7.6). Visual examinations did 14

1 not reveal any items that would render the snubbers non-functional, therefore there were no failures. Of the snubbers that were functional tested, there were three (3) failures of the test sample.

Sample expansion of 104 of that type snubber was performed resulting in seventeen (17) additional snubbers being tested. One functional test failure did occur on a snubber tested during the sample expansion. However the failure occured during a non-Tech. Spec.

test in which the final drag is measured. Since final drag is not recyxired by Tech. Spec. 4.7.6.e an expanded sample in accordance with Tech. Spec. 4.7.6.d.l was not performed.

Therefore, FPL has met all ASME Section XI and Plant Technical Specification requirements for visual examination and functional testing of snubbers at Turkey Point Unit 4.

15

~ l ACRONYM LIST The following Summary:

is a list of all acronyms used in this Snubber ASME American Society of Mechanical Engineers AP Administrative Procedure OP Operating Procedure CMM Corrective Maintenance Mechanical SNPS Siemens Nuclear Power Services PP Project Plan CAL Calibration EXM Examination TST Testing MNT Maintenance Rev. Revision Inc. Incorporated PSA Pacific Scientific Arrestors MSA Mechanical Shock Arrestor's AFW Auxiliary Feedwater FW Feedwater MS Main Steam CCW Component Cooling Water VT Visual Test FT Functional Test SAT Satisfactory DEV Deviation PTN Turkey Point Nuclear RHR Residual Heat Removal SIS Safety Injection System SG Steam Generator RCS Reactor Coolant System INFO Information CVCS Chemical and Volume Control System WD Waste Disposal Int. Initiated TTA Transition Tube Assembly CR Condition Report PWO Plant Work Order S/N Il LII Serial Number Length PCM Plant Change Modification FPL Florida Power & Light IAW In Accordance With 16

TURKEY POINT UNIT 4 1993 REFUELING OUTAGE Final Report of Hydrostatic Testing Program

Abstract This report details the hydrostatic testing. of selected class 2, and 3 piping and components of the Florida Power and Light Company Turkey Point Unit 4 which were performed during and subsequent to the 1993 refueling outage, between the dates of April 13, 1993 and June 18, 1993.

Piping and components were selected and tested in accordance with Section XI of the American Society of Mechanical Engineers (ASME)

Boiler and Pressure Vessel Code " Rules for Inservice Inspection of Nuclear Power Plant Components", 1980 Edition with addenda through Winter 1981, and ASME Code Case N-498, "Alternative Rules for 10 Year Hydrostatic Pressure Testing for Class 1 and 2 Systems"Section XI, Division 1 (Approval date May 13, 1991).

Procedures The following FPL procedures and documents have been implemented to provide instructional guidance for the performance of the required ASME XI hydrostatic testing, and subsequent inspections.

AP 0190.90- ASME Section XI pressure tests for quality groups A, B, and C Systems/Components.

OP 1506.7 Steam Generator Hydrostatic Pressure Test.

NDE 4.2 Visual Examination VT-2 Conducted During System Pressure Tests.

0-ADM-217 Conduct of Infrequently Performed Tests or Evolutions.

WCAP-13155 Technical Basis for Determination of Secondary Side Pressure Test Temperatures, Turkey Point Units 3 and 4 Steam Generators.

S stem Summa  : Unit 4 The following safety related systems, or sections thereof were hydrostatically tested in accordance with ASME Section XI.

Name of system System number Steam Generators 71 Steam Generator Blowdown 71 Main Steam 72 Feedwater 74 Intake Cooling Water 19 Spent Fuel Pool Cooling 33

0

~Acrcn s AP Administrative Procedure ADM Administrative ASME: American Society of Mechanical Engineers CCW Component Cooling Water HX Heat Exchanger ICW Intake Cooling Water NDE Non Destructive Examination SFPC: Spent Fuel Pool Cooling TPCW: Turbine Plant Cooling Water OP Operating Procedure WCAP: Westinghouse Commercial Atomic Power

0 Test Packa e Develo ment The specific pressure test boundaries were selected after review of the applicable plant operating diagram/code boundary Drawing. The piping systems were first broken down into sub-systems. The sub systems were selected based on Technical Specification operability requirements, acceptable isolation points and availability of test connections and vent valves. These sub-systems were then assigned a test package number, which could be tested in the entirety, or based on availability, could be broken down further into numerous tests within that specific sub-system.

The pressure test package numbers contain six segments of information.

Sample: 03-CCW-30110-H-Ol t t t t t t 1 2 3 4 5 6 1~ Unit number (00) common to units 3 and 4. (03) unit 3 specific (04) unit 4 specific 2 ~ System abbreviation 3 ~ System number [First (2) digits]

4 ~ Sub-system number [(2) or (3) digits]

5. Type of test (H) hydrostatic (F) system functional (I) system inservice
6. Number of tests performed within the specific sub system.

0 Intake Coolin Water S ste 19 04-ICW-1992-H-01 Test date 4/13/93 This test involved the ICW piping associated with >>A>> ICW header, >>A>> ICW pump, >>A>> CCW HXg and >>A>> TPCW HX. All leakage noted during this test was found at mechanical joints (i.e., packing, seals, bolted connections etc.)

which does not require retesting per ASME Section XI. All leakage was addressed by the following plant work requests:

93006466 93006467 93006468 93006469 93006471 93006480 93006481 04-ICW-1993-H-01 Test date 4/13/93 This test involved the ICW piping associated with >>B>> ICW header,>>B>> and >>C>> ICW pumps, >>B>>

and >>C>> CCW HX, and >>B>> TPCW HX. All leakage noted during this test was found at mechanical joints (i.e., packing, seals, bolted connections etc.) which does not require retesting per ASME Section XI and was addressed by the following plant work requests:

93006472 93006474 93006479 93006476 93006480

8 ent Fuel Pool Coolin 8 stem 33 04-SFPC-3326-H-02 Test date 6/18/93 This test involved the SFPC piping associated with the refueling water purification pump, the spent fuel pool demineralizer, and the spent fuel pool filters. No leakage was noted during this test.

OP 1506.7 Steam Generator H drostatic Pressure Test Includes S stems 71 72 and 7i OP 1506.7 Test date 4/17/93 This test was performed in order to satisfy all repair/replacement hydrostatic testing requirements which had been deferred in accordance with ASME Code Case N-416 "Alternative Rules for Hydrostatic Testing of Repair or Replacement of Class 2 Piping"Section XI Division 1 (approval date 12/05/84).

This test included steam generators "A", "B", "C", and associated main steam, feedwater, and blowdown piping extending to the "B" to "D", or the "B" to "SR" class breaks outside containment. All leakage noted during this test was found at mechanical joints (i.e., packing, seals, bolted connections, etc.) which does not require retesting per ASME Section XZ. All leakage was addressed by the following plant work requests:

93006736 93006740 93006741 93006742 93006743 93006745 93006751 93006753 93006754 93006755 93006756 93006757 93006758 93006760 93006761 93006765 93006766 93006767 93006771 93006768 93006772 93006808 93006809 93006810 93006811 93006814 93006816 93006817 93006995 93006996 93006999 93007000 93007001 93007002 93006824 93007003 92056277 93007004 93007005 93007006 93006837 93006838 93007007 93006839 93006904 93006884 93006885 93006886 93006887 93006888 93007008 93012092 93012090 93007009 93006905 93006907 93008534 91058708 93006903 93006910 93006911