Health Physics Procedure HP-48, Process Control Program for Dewatering Radwaste Liners
ML17348A538
Person / Time
Site: Turkey Point  
Issue date: 02/13/1990
From:
FLORIDA POWER & LIGHT CO.
To:
Shared Package
ML17348A537 List:
References
HP-48, NUDOCS 9009050274
Download: ML17348A538 (14)


Text

~

s v

s

~

1.0 Titie

FLORIDA POWER AND LIGHT COMPANY TURKEY POINT UNITS 3 AND 4 OPERATING PROCEDURE 11550.4B HEALTH PHYSICS PROCEDURE HP-48 FEBRUARY 13 1990 PROCESS CONTROL PROGRAM FOR OEWATERING RADIOACTIVE WASTE LINERS 2.0 A

royal and List of Effective Pa es:

2.1

~Aroval:

Change gated

~2 13 90 Reviewed by Plant Nuclear Safety Committee:

90-037 and Approved by Plant Nanager - Nuclear:

2II13 90 2.2 List of Effective Pa es:

~Pa e

3.0

~pur ose:

Date Pacae 02/13/90 4

02/13/90 5

02/13/90 6

Date 02/13/90 02/13/90 02/13/90

~Pa e

Date 02/13/90 The Turkey Point Process Control Program (PCP) implements requirements of the Turkey Point 3 and 4 Technical Specifications and provides instructions for the removal of free-standing water from liners containing radioactive bead

resin, powdex resin, or charcoal.

3.1 Discussion

The PCP contains provisions to ensure that dewatering of radioactive bead resin, powdex resin and charcoal results in a waste form with characteristics that meet the requirements of 10CFR 61 as implemented by 10CFR 20 and of the low level radioactive waste disposal site.

The Process Control Program includes in addition to this procedure, the following related documents:

3.1. 1 Westinghouse Radiological Services, Inc. procedure STO-O-03-009, A Users Manual for the Westinghouse RAOLOK-200, RAOLOK-500, RADLOK-100, RAOLOK-179, and RAOLOK-195, SOC Controlled Vendor Manual AA693 3.1.2 Westinghouse Radiological Services, Inc. procedure STD-P-03-003, RADLOK Manway Assembly Closure and Sealing Procedure, SOC Controlled Vendor Manual AA693 RTSs 1898, 88-2985, 90-0137P This procedure may be affecti rIhv ar 0 T.S.C (On The Spot Change) verify dntorm~tioli<Jr'iof fbi us<

Date verified inioals

+/cm/sw 9009050274 900 PDR ADOCK 05000250 S27 R

PDC

~

.OPERATING ROCEOURE 11550.48, HP-48, PAGE PROCESS CONTROL PROGRAM FOR OEWATERING RADIOACTIVE WASTE LINERS 2/13/90

3. 1.3 Westinghouse Radiological Services, Inc. procedure STO-P-03-004, Closure of Hittman RADLOK High Integrity Container Fill Port Closure Assembly, SOC Controlled Vendor Manual AA693
3. 1.4 Westinghouse Radiological Services, Inc. procedure STO-P-03-046, Transfer and Oewatering Ion Exchange Resin and/or Activated Charcoal Filter Media Using the Hittman Rapid Oewatering
System, SOC Controlled Vendor Manual AA693
3. 1.5 Westinghouse Radiological Services, Inc. procedure STO-P-03-052, Transfer and Oewatering Ion Exchange Resin and/or Filter Media Using the Press Pak System, SDC Controlled Vendor Manual AA693
3. 1.6 Westinghouse Radiological Services, Inc. procedure STD-P-03-010, Transfer and Oewatering Bead Resin in Hittman RADLOK High Integrity Containers With a Single Layer Underdrain Assembly to Less Than lX Drainable Liquid, SOC Controlled Vendor Manual AA693
3. 1.7 Westinghouse Radiological Services, Inc. procedure STO-P-03-020, RAOLOK Inspection Procedure, SDC Controlled Vendor Manual AA693 3.1.8 Westinghouse Radiological Services, Inc. Process Control Program STO-PCP-03-003, Westinghouse Hittman Mobile Incontainer Oewatering and Solidification Systems
3. 1.9 Ouratek Corporation procedure TPf 10-3, Ouratek Sluicing Media 3.1. 10 Ouratek Corporation procedure TP8 12-1, Operation of the HEO System I
3. 1. 11 Duratek Corporation procedure TPf 10-1, Operation of the Ouratek EVR System
3. 1. 12 Ouratek Corporation Process Control Program 14-2, HEO Process Control Program
3. 1. 13 Ouratek Corporation Topical Report Number 0-EVR/HED-1-NP-"A",

Topical Report for EVR/HED System for Treatment of Nuclear Power Reactor Waste Liquids

3.2 Authority

The authority and responsibility to perform this procedure comes from 10CFR 20, 10CFR 61, Turkey Point Plant Units 3

and 4

Technical Specifications, and disposal site licenses.

~

~

~

I A

~

0 g

~

r

~

~

~

I OPERATING ROCEDURE 11550.48, HP-48, PAGE

~

PROCE'SS CONTROL PROGRAM FOR OEWATERIHG RADIOACTIVE WASTE LINERS 2/13/90

3.3 Definitions

3.3. 1 Dewatering:

The process of removing "Free-Standing" water from a

final disposal package.

3.3.2 "Free-Standing Water":

Liquid which is not retained by the waste form.

3.3.3 Process Control Program (PCP):

A program which contains the provisions, based on full scale testing, to ensure that dewatering of radioactive bead resin, powdered resin or charcoal results in a waste form with the properties that meet the requirements of 10CFR 61 (as implemented by 10CFR 20) and of the low level radioactive waste disposal site.

4.0 Precautions

4.1 Instructions used for the dewatering of liners which establish the conditions to be met, shall be based on full scale testing.

This is to provide reasonable assurance that the dewatering will result in volumes of free-standing water, at the time of disposal, within the limits of 10CFR, Part 61 as implemented by 10CFR 20 and of the low

-level radioactive waste disposal site.

4.2 Class "6" and "C" radioactive waste (as determined by 10CFR.61 and O-HPA-040, Shipping and Receiving Radioactive Material) may be transferred to the disposal site in a High Integrity Container (HIC) approved for disposal by the licensing agency for the disposal site.

Ho other containers may be used without PNSC approval.

4.3 Do not use High Integrity Containers for radioactive material that could chemically or physically damage or otherwise exceed the allowable limits of the HIC.

4.4 Changes to the Turkey Point Plant Process Control Program shall be reviewed and approved by the PNSC before they become effective.

4.S Changes to the Turkey Point Plant Process Control Program shall be submitted to the HRC in the Semiannual Radioactive Effluent Release Report for the period in which the change(s) was made.

This submittal shall contain the following:

4.5.1 Sufficiently detailed information to support the rationale for the change.

4.5.2 A

determination that the change did not reduce the overall conformance of the dewatered waste to existing criteria for stabilized waste form.

4.S.3 Documentation of the fact that the change has been reviewed and found acceptable by the PNSC.

klemlsw

d

~

~

~

p \\

(

I

~

~ OPERATING I

OCEOURE 11550.48, HP-48, PAGE PROCESS CONTROL PROGRAM FOR OEWATERING RAOIOACTIVE WASTE LINERS 2/13/90 4.6 4.7 4.8 4.9 Oisposal of radioact1ve bead resin which is Class 8 or Class C, or wh1ch 1s Class A and has a concentration of radionuclides with half-11ves greater than f1ve years and exceeding one microcur1e per cubic centimeter, fs limited to HICs with an approved certificate of compliance issued by the 11censing agency for the disposal site.

Radioactive bead resin which is Class A, and which has a concentration of radionuclides with half-lives greater than five years but not exceeding one microcurie per cubic centimeter, may be packaged in HICs or disposable carbon steel cask liners.

Oisposal of radioact1ve charcoal filter media which is Class B or Class C, or which has a concentration of radionucl1des with half-lives greater than five year s and exceeding one microcurie per cubic centimeter, is limited to HICs with an approved cert1ficate of compliance issued by the licensing agency for the disposal site.

Radioactive charcoal filter media which is Class A, and which has a

concentration of radionuclides with half-lives greater than five years but not exceeding one microcurie per cubic centimeter, may be packaged in HICs or d1sposable carbon steel cask liners.

4.10 01sposal of condensate polishing resin is permitted in HICs or disposable cargon steel cask liners.

4.11 Personnel performing the dewatering procedure should be aware that strong oxidizing agents such as nitric acid, when in contact w1th organic ion-exchange material and in the presence of air, may produce a slightly degraded resin in an exothermic reaction, up to an-explosion.

The first indication of an exothermic reaction due to the presence of oxid1zing agents is some fuming and a slight rise in temperature on the outside of the container.

If this cond1tion is found when dewatering a vessel, immediately refill the vessel with water.

This will elim1nate one of the 1ngredients necessary for the reaction (air) and will dissipate the majority of the heat, returning the temperature of the vessel to ambient.

When the condition has stabilized, notify the immediate supervisor.

5.0 Res onsibilities:

5.1 It is the responsibility of the Plant Manager to assure that necessary procedures, equipment and support are provided to properly implement the PCP.

5.2 It is the responsibility of the Health Physics Superv1sor, or designee, to ensure that all liners will be dewatered in accordance with the PCP.

6.0 References Commitment Oocuments:

6.1 References 6.1.1 Turkey Point Units 3 and 4 Technical Specifications No. 3.9.3 t/em/ew

I I

0

~

~

l

,I

I

~

J

~ OPERATING OCEOURE 11550.48, HP-48, PAGE PROCESS CONTROL PROGRAM FOR OEWATERING RADIOACTIVE WASTE LINERS 2/13/90 6.1.2 Westinghouse Radiological Services, Inc. procedure STD-O-03-009, A Users Manual for the Westinghouse RADLOK-200, RAOLQK-500, RADLOK-100, RAOLOK-179, and RAOLOK-195, SOC Controlled Vendor Manual AA693

6. 1.3 Westinghouse Radiological Services, Inc. procedure STO-P-03-003, RADLOK Manway Assembly Closure and Sealing Procedure, SDC Controlled Vendor Manual AA693
6. 1.4 Westinghouse Radiological Services, Inc. procedure STO-P-03-004, Closure of Hittman RAOLOK High Integrity Container Fill Port Closure Assembly, SOC Controlled Vendor Manual AA693 6.1.5 6.1.6 6.1.7 Westinghouse Radiological Services, Inc. procedure STD-P-03-046, Transfer and Dewatering Ion Exchange Resin and/or Activated Charcoal Filter Media Using the Hittman Rapid Oewatering
System, SDC Controlled Vendor Manual AA693 Westinghouse Radiological Services, Inc. procedure STD-P-03-052, Transfer and Dewatering Ion Exchange Resin and/or Filter Media Using the Press Pak System, SOC Controlled Vendor Manual AA693 Westinghouse Radiological Services, Inc. procedure STO-P-03-010, Transfer and Dewatering Bead Resin in Hittman RAOLOK High Integrity Containers With A Single Layer Underdrain Assembly to Less Than 1X Orainable Liquid, SOC Controlled Vendor Manual AA693 6.1.8 Westinghouse Radiological Services, Inc. procedure STO-P-03-020, RADLOK Inspection Procedure, SOC Controlled Vendor Manual AA693
6. 1.9 Westinghouse Radiological Services, Inc. Process Control Program STD-PCP-03-003, Westinghouse Hittman Mobile Incontainer Oewaterfng and Solidification Systems
6. 1.10 Ouratek Corp. procedure TPf 10-3, Slucing Media 6.1.11 Ouratek Corp. procedure TPk'2-1, Operation of the HED System 6.1.12 Duratek Corp. Process Control Program 14-2, HEO Process Control Program 6.1.13 Ouratek Corp. procedure TPf 10-1, Operation of the Ouratek EVR System I

6.1.14 6.1.15 Ouratek Corp., Topical Report Number D-EVR/HED-1-NP-"A", Topical Report for the EVR/HEO System for Treatment of Nuclear Power Reactor Waste Liquids.

Health Physics Administrative Procedure, 0-HPA-040 "Shipping and Receiving Radioactive Material."

0/em/sw

\\

~

~

I t

~

OPERATING CEDURE 11550.48, HP-48, PAGE 6

'ROCESS CONTROL PROGRAM FOR DEWATERING RADIOACTIVE WAS E LINERS 2/13/90 6.2 6.1.16 49CFR 6.1.17 10CFR 61 6.1.18 OP-5333.1 "WDS Transferring Spent Storage Tank To Shielded Shipping Cask" I

Commitment Documents I

6.2.1 Quality Assurance Audit QAO-PTN-89-996 7.0 Records and Notifications:

7.1 7.2 7.3 If it is suspected that the free-standing water requirements have not been met for any container shipped to a disposal site, the Plant Manager and the Health Physics Supervisor shall be notified.

If the Process Control Pr ocedures have not been followed or if free standing water is suspected in the final shipping container in amounts greater than allowed by regulations, the Radwaste Supervisor shall be notified.

Completed copies of the below listed item(s) constitute Quality Assurance Records and shall be transmitted to Site Document Control QA Records Section for retention in accordance with Quality Assurance Records Program requirements:

7.3. 1 Form HP-72C, Specification Container Shipping Release 7.3.2 Form HP-72-L, Powdex Resin Liner Shipping Release Form

8.0 Instructions

8.1 8.2 8.3 Dewatering shall be performed in accordance with the applicable vendor procedure for each liner or High Integrity Container (HIC).

If the dewatering is not performed in accordance with the vendor procedure, the process shall be terminated.

The package shall not be shipped for disposal until it is dewatered in accordance with the vendor procedure.

If the final waste form is found to be unacceptable (freestanding liquid in excess of 0.5% of the waste volume for steel liners or 1.0X for high integrity containers) processing and shipping shall be stopped until the procedures and/or dewatering equipment are corrected to prevent recurrence.

8.4 Dewatering of Westinghouse RADLOK HICs 8.4.1 Westinghouse RADLOK HICs containing bead type ion exchange resin shall be dewatered in accordance with Westinghouse Radiological Services, Inc. procedures STD-P-03-046 reference 6.1.5),

STD-P-03-052 (reference 6.6), or STD-P-03-010 reference 6.1..7) t/em/sw

'l

~

e l

p

~

~

g,

.OPERATING CEOURE 11550.48, HP-48, PAGE PROCESS CONTROL PROGRAM FOR OEWATERING RADIOACTIVE WAS E LINERS 2/13/90 8.4.2 HICs shall be dewatered to less than one percent free-standing

)

liquid.

I 8.5 Oewatering of Nupak 210 HICs fitted with Ouratek Oewatering Internals which contain bead resin and Charcoal Filter Media 8.5. 1 NuPak 210 HICs fitted with Ouratek dewatering internals shall be dewatered using Ouratek Corp procedures TPf 10-3 (reference 6.1.10),

TPP 12-1 (reference 6.11),

and TPf 10-1 (reference 6.1.13).

8.5 Oewatering of Westinghouse RAOLOK HICs or carbon steel liners containing Powdered Ion Exchange Resin 8.6. 1 Westinghouse RAOLOK HICs and carbon steel cask liners containing powdered ion exchange resin intended for direct disposal shall be dewatered in accordance with Westinghouse Radiological Services, Inc. procedure'TO-P-03-046 (reference 6.1.5).

8.6.2 The above containers shall be dewatered to less than one half of one percent free-standing water (carbon steel liners) or one percent free-standing water (HICs).