ENCLOSURE 1
NOTICE OF VIOLATION Florida Power and Light Company Turkey Point Nuclear Plant Docket Nos. 50-250, 50-251 License Nos.
During the Nuclear Regulatory Commission (NRC) inspection conducted on April 2-6, and April 30 - May 4, 1990, violations of NRC requirements were identified.
In accordance with the "General Statement of Policy and Procedure for NRC Enforcement Actions,"
10 CFR Part 2, Appendix C (1990), the violations are listed below:
A.
Technical Specification 6.11 requires procedures for personnel radiation protection to be prepared consistent with the requirements of 10 CFR 20 and to be adhered to for all operations involving personnel radiation protection exposure.
Licensee procedure O-HPA-002, Requirements for Entry and Work in the RCA.,
dated July 14,
- 1989, requires all personnel working in areas under a,
Radiation Work Permit (RWP) to read and to comply with all instructions, requirements, and remarks listed on the RWP.
'RWP 90-401'5, Uni't 3 '(U3) 'Containment 58 foot (58') and '30'" 'Elevations-Replace/Repair/Maintain/Modify the Normal Containment Cooler System and
- Motors, dated February 1,
- 1990, requires that.prior to entering the Radiologically Controlled Area (RCA) each individual discuss the scope of work with the Health Physics Shift Supervisor (HPSS) and notify the Work Area Health Physics (HP) technician prior to starting work.
Contrary to the
- above, during the period March 26-28,
- 1990, selected workers entered the U3 Containment and initiated work on the "C"
Containment Cooler System without contacting the HPSS nor the Containment Work Area HP technicians.
This is. a-...Severity Level IV violation (Supplement IV).
B.
10 CFR. 20.203(e)requires each area in which licensed material is used or stored.'and<which contained any radioactive material in an amount exceeding ten times< the; quantity of such material specified in Appendix C of this part to be posted with a sign or signs bearing the radiation caution symbol and the words:
"Caution, Radioactive Material(s)."
Contrary to the above, on May 2,
- 1990, the licensee failed to maintain adequate visible posting for a radioactive waste bin storage area located adjacent to, and north of the Old Compactor Waste Building.
This is a Severity Level IV violation (Supplement IV).
9006Zi047Z 900606 PDR ADOCK 05000250,-)
6 PNU eke
'Florida Power and Light Company Turkey Point Nuclear Plant Docket Nos. 50-250, 50-251 License Nos.
DPR-31, DPR-41 Pursuant to the provisions of 10 CFR 2.201, Florida Power and Light Company is hereby required to submit a written statement or explanation to the Nuclear Regulatory Coranission, ATT8:
Document Control'esk, Washington, DC
- 20555, with a
copy to the Regional Administrator, Region II, and a copy to the NRC Resident. Inspector, within 30 days of the date of the letter transmitting this Notice.
This reply should be clearly marked as a "Reply to a Notice of Violation" and should include [for each violation]:
(1) admission or denial of the violation, (2) the reason for the violation if admitted, (3) the corrective steps which have been taken and the results achieved, (4) the corrective steps which will be taken to avoid further violations, and (5) the date when full compliance will be achieved.
Where good cause is shown, consideration will be given to extending the response time.
If an adequate reply is not received within the time specified in this Notice, an order may be issued to show cause why the license should not be modified, suspended, or, revoked or why such other action as may be proper should not be taken.
-. FOR THE NUCLEAR REGULATORY COMMISSION Dated at Atlanta, Georgia this~ day ofM~~
1990 Douglas N. Collins, Chief Emergency Preparedness'nd Radiological Protection Branch Division of Radiation Safety and Safeguards