PAGE 2

OF 10 8.Examination Dates 10-1-83 to 1-7-84

9. Inspection Interval from 6 ~23 YEARS to

.10 YEARS

10. Abstract of Examination.

Include a list of examinations and a

statement concerning status of work required for current interval.

SEE ATTACHED SUPPLEMENT ll. Abstract of Conditions Noted.

SAME AS ITEM 10 ABOVE

12. Abstract of Corrective Measures Recommended and Taken.

SAME AS ITEM 10 ABOVE We certify that the statements made in this report the examinations and corrective measures taken conform to the ASME Code,Section XI.

Date 3D W 19~9 Signed y

Owner correc e rules o

Certificate of Authorization no.(if applicable)

~N A Expiration date N/A CERTIFICATE OP IHSERVICB IHSPECTIOH I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and/or the State or Province of DADE CTY.

PL and employed by ee of NORWOOD MASS have inspected the components described in this Owners'ata Report during the period OCT 1993 to JANUARY 1994 and state that to the best of my knowledge and belief, the Owner has performe examinations and taken corrective measures described in this Owners'ata Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners'ata Report.

Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Dat~M~ S~

19+/

FACTORY MUTUAL SYSTEM Commissions COMM N0.4956 Inspector'ignature National Board, state, Province and No.

    • ARKWRIGHT BOSTON MFG S

MUTUAL INSURANCE COMPANY

0

SUPPLEMENTAL SHEET NIS-1 PAGE 3 OF 10

l. Owner: Florida Power 6 Light Co.

9250 West Flagler Miami, Florida 33152

2. Plant:

TURKEY POINT P.O.

Box 3088 FLORIDA CITY, Florida 33034

3. Plant Unit :

3 4.

Owner Certificate of Authorization

N/A
5. Commercial Service Date:- 14 DECEMBER 1972
6. National Board Number for Unit: N/A 10.

REPORT NUMBER ORGANIZATION DESCRIPTION OF SERVICE CIG-PTP-84-001 P

SWRI 4352 SWRI 4352 N/A FPL SWRI SWRI WESTINGHOUSE IN SERVICE INSPECTION VOLUME I THROUGH VOLUME 2 1983 INSERVICE EXAMINATION OF SELECTED COMPONENTS OP TURKEY POINT PLANT, UNIT 3 VOLUME 1.THROUGH VOLUME V

.1983 VISUAL EXAMINATIONS

" CONDUCTED 'XN CONJUNCTION WITH HYDROSTATIC PRESSURE TESTING. AT 'TURKEY POINT PL'ANTi UNIT 3

'VOLUME 1 RPV CLOSURE HEAD MODIFICATION

iS 0

FORM NIS 2

OWNER S

REPORT FOR REPAIRS OR REPLACEMENTS As required by the provisions of the hSME Code Section XI

l. Owner FLORIDA POWER

& LIGHT CO.

name P.O.

BOX 529100 MIAMI< FLORIDA 33152 address TURKEY POINT

2. Plant name P.O.

BOX 3088 FLORIDA CITY, FL.

33034 Date sheet 4

of 10 Unit PC/M NO.

82-30 I

c address WESTINGHOUSE

3. Work Performed by name P 0-BOX 2728 PITTSBURGH'ENNSYLVANIA 15230 address repair organization P.O.

No.

job No., etc.

NONE Type Code Symbol Stamp N/A Authorization no.

Expiration Date

4. Identification of system REACTOR PRESSURE VESSEL 5.

(a) Applicable Construction Code SECTION III 1980 Edition 1980 Addenda, 1588 Code Case (b) Applicable Edition of Section XI utilized for repairs or replacements 1974 EDITION

6. Identification of components repaired or replaced and replacement components Name of Component Name of Mfr.

Mfrs. Ser. Nat'1 Crn No.

Bd.

No.

No.

Other Year Ident-Built ifica-tion Repaired Replaced or repl-acement ASME Code stamped (yes,no)

RPV B5:W B&W 16081-1 16081-2 N/A N/A N/A N/A N/A 1968 N/A 1968 MODIFI-CATION MODIFI-CATION YES YES

lh

PAGE 5

OF 10 FORM NIS-2

7. Description of work SEE SUPPLEMENT SHEET, PAGE 6

OF 8

Tests Conducted:

Hydrostatic X

Pneumatic Nominal Operating Pressure Other Pressure 2335 psi Test Temp.

547 F

ICCS MODIFICATION TO THE REACTOR PRESSURE VESSEL CLOSURE

9. Remarks (Applicable Manufacturer's Data Report to be attached)

HEADf N2 DATA REPORT FOR THE RVLMS FLANGE ASSEMBLIES ARE ATTACHED CERTIFICATE OF COMPLIANCE To certify that the statements made in this report are correct and this MODIFICATION conforms to Section XI of the ASME Code.

( Repair or Replacement

)

Signed

{Orner. o er Des gnee)

. {T tie)

{Date)

CERTIFICATE OF INSPECTION I~ the Undersigned, holding a valid commission"issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade Cty, Fl. employed by of NOR%GOD MASS have inspected the MODIFICATION described in this report on 19 and state that to the best of my knowledge and belief, this repair or replacement has been constructed in accordance with Section XI of the ASME Code.

By signing this certificate, neither the Inspector nor his employer takes any warranty.

expressed or implied, concerning the repair or replacement described in this report.

Furthermor

, neither the Inspector nor his employer shall be liable in any manner fo any personal injury or property damage or a loss of any kind arising from or connected with is i spection.

DADE CTY COMM.NO.4956 DatePR-JC'/~~K Commissions FACTORY MUTUAL SYSTEMS

,.(Inspe or)

(State or Province, National Board)

    • ARKWRIGHT BOSTON MFG'S MUTUAL INS. CO.

O.

NIS-2 SUPPLEMENTAL.SHEET PAGE 6

OF 10 1

OWNER:

2'.

PLANTc FLORIDA POWER R LIGHT P O',BOX 529100 MIAMIg FLORIDA 33152 TURKEY POINT P.O.

BOX,3088 FLORIDA CITY, FLORIDA. 33034 DATEt 80&mcL IRS'I UNITc 3 3.

WORK

. PERFORMED

, BY'.

4 IDENTIFICATION OF SYSTEM:

7 DESCRIPTION

.OF WORK:

WESTINGHOUSE ELECTRIC CORPORATION JOB NO. PC/M 82-30 P.O.

BOX 2728 PITTSBURGHt PENNSYLVANIA REACTOR PRESSURE VESSEL HEAD COMBUSTION ENGINEERING PERFORMED. THE DESIGN AND FABRICATION OF THE FLANGE ASSEMBLY.

. WESTINGHOUSE ELECTRIC, PERFORMED THE INSTALLATION.

,AND. WELDING OF THE RVL'MS FLANGE ASSEMBLY.

COMBUSTION ENGINEERING PERFORMED THE INSTALLATION

.OF. THE INSTRUMENTATION.

LINESFPL.'PERFORMED.

THE.HYDROSTATIC.PRESSURE. TESTS'

0

FORiiI N t IiIANL>lACT:Rr DATA REPOFT FOR NUCLEAI PT AND APPIIRTENANCF5o

'I hr-rcqtIired bt the Prod'f. iona o! the AR)E Co c Ru)es

" Corrected 10/14/83

l. (s) lhsnufsctured by e

(hase anc adcrr ~ ~ of sranrcr crrro ~ r of part)

(b) +anuf eau 8fF1 ori da Power 5 li ht Turke Poi nt ni s

fwscar ond od&ras of Stsnufsetcvsr of creaptstsd auctaor coaponrnt)

Identifieationktanufstturer's Serial No. of Part

.Nat'l Bd. No.

N A

(> C.t~.t 8 he.o~. gaoDr ing,x E" D.- gP p~by NuClear PrOduCtS ManufaCtur (b) Descriptron of Part Inspected RVLKS Fl an e ASSembl Minter (e) hpp)ieab)e ~ECodetscecionll),Kdition3939~,

hddends dat<393f', C>>eNo.~g C)>>s Final desi n

nforttation and tr ss r or s

r (Brief dracrfptton of scrvles for oihich component v sa drslansd) 0'e certify that the statements made in this report arc'orreec,and this vessel pare.or appurtenance as defirred in the Code con-forms co ahe rules of eonstruecioo of the hShtE Code Seer)on Ill.

(The applicable Design Specification an8 Stress R

rc arc: not the responsib.')icy of ahe gart Sfanufacturer. hn appurcensnee

)danufaecurer is responsib)e for furnishing a sepsrare Design Specification and Stress Report cf the appccrterranee is arot included in che component Design Speeifieation and Stress Report.)

Date

>> g~ s;~~Combustion En In K.C. -Tolides-Manager of gualitv o

~nt Cetuficate of huthorization Expires Cenirreat. of huthoriaatfon Noo

,~Rg FIChmIN QF 9EQGN.FOR hPPi3RKNANX(vkeat applicable) f 6]

Combustion En J neeri n Stress analysts report on Gle at See 3 remarks P~f. Eng. S <<~L Reg.N&L'65 Stress analysis report certified by Prof. Eng. Scale aor.No.

CERllFlCATE OF SHOP INSPEC110N I,-ihe crndersignedr holding a valid cocnmissioo issued by the National Bot d of Botler and Pressure Vessel Inspectors and/or th>> State or Province of and employed byBBZ Hartford Connecti u

have ins ected th>> patt of a pressure resse) described in this gfanufsecure! s Partes) Dscs Report on re> /I 19',

and state that to.ahe besc of my hnoaledge an8 belief, the Manufacturer bas eonstrueced rhis part in aeeordanee <<ith the AWE Code Section Iu.

By signing this eertifieatcr neithei the lnspeccor.nor his employe:r makes any <<srranty, expressed or implied, eoneern-ing the part described in this Manufacturer s Partial Data Report Furtherrnorer t either the Inspector nor his ecnployer shall be liable in any manner for any personal injury or property damage or aloss of any hind arrsing from or eonnteced

<<ith this inspection.

Date

/al nspcctce

~ Stgnstcvs Cocmni s si on s National Soard, Sc ~rc, Province and )fo.

~ sui pfrecnraf shrcia Jn Sate of liar~, ~Lrtchr ~ or drsa'tnaa esr hr sard proetdr d tt) ster oa S)l" s ll", t2) Jnforeattog. tn ctree l 2 on thf ~

dora rcPort la tncfodrC rc. each sheet

~ snC ts) each abrrl la nrmbrrrd anC rIcL br ~ O. ~'brr r lc rrcorCrC tn tree 2, i'Rresrbc '

FO)W K-2 (bacL) liters i-6 loll. tt hr tnmf Irted (or sirfgle +aH vessels, jackets of jsd cled vessels, or shell ~ o( hest czthahgrra.

S err TSPe 316 SST.

ac ccc "'.'-'0n ~

~ 0 3.760 P-4 6 8

.3

~

ac ccc '.'f aa fir a l8 I a.2f! teer Thief st 1

.iflfo c

ia. Dis.

fc.'

. i.c fc'1 Ic,S ia case

.a

.1 fca

~ ca

% ar III ri 5.

'/A Se ams:

Long H.T.

T.S.

Crews Kaefchge

'yhlehrfess Radios Radfea (a)

G;h1 Butt Meld H T.t Heads:

(a) Material Leeat ion (yep, haetora, arlda)

R.T.

Efficiency Full No. of Courses (b) Material Beset spherical Ratio Ages Angle Radius Flat Side lo Presa.

Dimeter (Coftv. <<Csee.)

(b) lf temovsb)et bolt ~ used (ttateriatc Spec.gto.

~'TS. ~ Slee,'ltffrfcber)

Other fastening (Describe et orroch stfetch)

N/A 8

Design pressure

) acket Closure (Describe aa alee and veld,bat,ete lfbat Slee disseoaietfarif belted, describe Or Sketch)

Drop %'eight Charpy impact pst at F

at temp. of fr-lb OF items 9 and 10 to be completed for tube sections N/A 9.

Tube Sheets: Stationary Floating.

N/A 10. Tubcst Material Material Dia.

O.D.

inc Thicknes s Thickness in. Attachment laches er asse.

Number (Str. ee U)

Materi Dia.

Thee'kness in. Attachment (g(bid Sc Spec. Ro.)

(Sffblect to press<<e)

(a'aided, Bolted)

Jtems 1] ]4 tuel to be comp'leted for inner chambets of jacketed vessels, or channels of beat cscbangets.

Nominal Corrosion ShelL Material TW Ie ctacss~.

Allo 'aac ~.

D' fc.

'a. f.cafe fa ia.

(g(ttfdh Spec. Xo.) (Mfrf ef Roose Spec(Bed) 8/A 1>

H.T.*

Kfficiency Ginh Heads (a) Material N/A xy.

H.T.'.Sc Raechle Elliptical Thictfttesa Radios Radios Ratio Location

~

~

~

(a) Top, bottom, ends (b) Channel lfremovable, bolts trsed (a)

(b)

(e) 65 2500 14.

Design pressure 2500 pst at

'No. of Cottrses (b) Material Cooicel Stesalsphertcal Apes Assis Radius Flat Side to Presa.

Diafaeter (Coav. er Cooc.)

ft Ib OF Other fastening (Describe or attach stfetch)

Drop Ireight Charp) impact F

at temp, of items

'belos. to be completed for all vessels abele applicable.

jt/A 15.

Safety Valve Outletst Number Size fe/A

16. Nott)es:

Location Ptfrpoae ()IItet, (3vtiet Dtair,)

Ni=bet Dia. or Size Type

~fateriat Thictffiea s ReinfotcerDenl ltsterisl How Attached 17

)6 inspection

Manholes, No.

Openings:

Hsndholes, No.

Threaded, No.

Svpponst Skirt (Yte o. Hc)

Sizt Size Site Lugs (h rber)

Location Location Location Other Legs (ricm>et)

(De actlbt) httsth!d (Sharc b How) l'ear~el

)ice -r tt tttC tttt tt ~ tost whto e

cricebrt,

FORM!aa-2 hid'XVfA RER5 DATA BLP01(T FOR NVCLEA RT AhaD API'VRTLaa 4'.aaCL5'h retiulrcd b) )hc Prov)@loni ot chc ATE Code Rules

). (.) M.r.,dby CMbustion En ineerin

- East Mindsor Connectlcu' (rtsaoe ond ~ a)C e ~ ~ or Ctsnaarsccaoer of Casrt)

(b) Manuraccuredfoc Florida Power 5 Li ht Turke Po'.nt Units 3 5 4 (cesar and odahoss K cconadoctwer of cocstalsced nor)ear coast "oenc) 2.

)dentification4lanufacturer's Serial No. of Part 16081-1 Nat'l Bd. No.

N A (a) Constructed hecordiagcoDra<<ingNo.E EST 849 500 Dra<<ingPrepared by Nuclear Products (b) Deseriptioa of Part inspected RVLMS Fl an A S tth Minter (c) hpplicable hWE Code: Section Ol,Edition~BQ

~ hddenda date~BE}, Case Yo.M38 Class Nanufactur.i sr Renaarks'i (Brief descrtratton or service for <<hlch ccsntaonenc <<ss desisned)

Ve certify chat the statements aaade in thcs report are correct and dais vessel part or appurtenanee as defined in the Code con-forms to the rules of eoastructina of the hSME Code Seccion Dl.

(Tbe a))plicable Design Specification and Scress Report are not chc responsibility of the part Mar.ufaeturer. hn appurtenanee Manufacturer is respoasible for furaishing a separate Design Specification and Stress Report if the appurtenance is not included in che cocnpoaent Design Specification and Stress Report.)

Date Cercdicate of huthorizacion Expires Comb. Engi Inc.

Con

()tsnad oct carer)

K. C. Tolides - Manager of gualit Certificate of huthoriaatioa Nc; CERHFICA'IIONOF DEQGN FOR hPPLNTENhNCE (vetcea applicab! e)

Design iafortnatioa oa file at Scress ana)ysis'cepon oa 6)e at Design specificatioas eertified by D.

cal. NCLau hlin Prof. Kng.State~~

Reg. No.~15.

Stress analysis repon certified by See 3 remarks Prof. Eng. Scare Reg. No.

GER'OFIChTE OF SHOP INSPECTIOYi 1, che cmdersigneda holding a valid commission issued by che Nations) Board of Boiler and Pres'ure Vessel Ins~ctors and/or che State or Province of Connecticut d employ

~ by Hartford Stea B(tile 1

8, 1

Hartford Connecticut hare inspected the part of ~ pressure ve sel described in this Manufacturer s Partial Data Rcport oa 19~and state that to chc best of aay kno<<ledge aad belief, the Manufacturer bag conscructed this part in accordance with the h%E Code Section ll..

By signing this certificate, neither the laspeccor nor his employer caches any warranty, expressard a implied, concern-ing cbe part described in this Manufacturer's Parttal Data Report. Furthertnore, ~either the )ns) ector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind art;ing from or coanected

<<'itb the s inspcctcon-Date 19M~

)nstar et or ~ fiisnstcoe Conunissions Notional Boord, ficste, 'Provhsce and No.

~ fiaaPP)assents) sheets Cn for<< of list~ a s)etchc s or drsavlncs nasr be used Carovtded (3) siss ia SS" n 3 3"a (1) in(ore cion in iteana 3~2 on this data report ia Cncio"rd on each sheet, snd (3) each sheet ta nac=hered on natcher of sheets is recorded Cn iten 3, aRemsc)a

~ ~.

Ik 0

cLi

S4

.e FOpbj !cc-'2 (bs CL) items 4-$ Incl. to be completed fof single asl) vessels, jsc'Lets of jsr) c ted vessel ~, of shc ll6 of he ~ I esrhsc.ger 6,

YP 76VSI w'

.I 600 m'"'tcc 0

3 7&0

&ff Shll: ff tci~I TS Thief '. hll c

i. LS ~.

ft.'

L ftl f.

1:/A 3.

S ams:

Long H.T.

R.T.

Efficiency tl/A Crown Thickness Rs dive (a)

(b)

CtfthttL

6. Heads:

(a) Material Location (Top, bottom, ends)

T S.

Eovehls Rodin ~

R.T.

Elliptical

'Rotto~t (b) Macerial Coolcol Stemtsphertest Apex Angle Rsdlvs T.Sc tlat Diameter Side to Press.

(Conv. or Conc.)

lfremovable, bolts used (Mstertst, Spec. 74o.,TcS., Sire, Ycumber)

Other fastening (Describe or attach shctch) f',IA K/A fL Design pressure psl at items 9 and 10 co be completed for cube seccions

7. jacket Closure:(Describe os ogre snd a eld, ba, ete.ll bsr give dimensions, lfbolted, describe or sheteh)

Drop %'eight Charpy impact oF at temp. of ft-]b OF

'g/A

9. Tube Sheecst Scationaty. Materia Di~

%Sickness in. hccachmcnt (Rind a Spec No.)

(Subject to pressure)

(a'etdedc Bolted)

FloaMlg Material g/A 10.

Tslbest Narerial Dia.

O.D.

in. Thickness Thickness in. httachment inches o ange.

Number Type (Str. oc U)

N/A items ll-lf(inel. to be completed for inner chambers of jacketed vessels, or channels of heac exchangers.

Nominal Corrosion ll. Shellt Material Tef.

IhidtCCC ~, tVICVCCCC~. ISC.'t, iC LCCStft fl.

ih.

(Etndgf Spec. }go.) +tin. a(Range Spec)Bed)

'lR. Seams: Long Il/A Nr A

13. Heads (a) Natenal H.T.

H.T.*

T.S.

R.T.

R.T.

'Efficiency No. of Courses (b) Material T.S.

tla Side to Press.

Diameter (Conv. a Conc.)

Location (a) Top, boctocn, ends (b) Channel lfremovab'lc, bolts used (a)

(c)

(b)

Other fascening (Describe or attach stfetch)

Drop E'eight Charpy lmpaec F

at rcmp. of 1

fc-lb OF 650 2500

14. Design pressure*

psl at Croon Knuchte Elliptical Conical Hemi spherical Tbtctsness Radius Radius Ratio Apex Angle Radios items be)on co be eompleced for all vessels ufhere applieablc.

N,A N;A Purpose (inlet, Out let, Drain)

Number

15. Safety Valve Outletm Number
16. Nozzlest Dia. or Slee Size Location Type grsterlal Thlchn vs s Retnfcveement hr st eclat

)C oo ht to c he d l

tCC

17. lnspcccion
Manholes, No.

Openingst Handholes, No.

Threaded, No.

)E.

Sug po..st Skirt (yes or )cc}

l I! Posfurtc Hf s'. Tfvsted.

Size Size Size Lugs (hvmbcr) location Location Locatior.

Legs (rcv~er)

Ocher 1 c sett r.

Attached (De seri bc)

(Shrrv rc Heal

0 0

J 1

<4

(/