L-83-451, Application to Amend Licenses DPR-31 & DPR-41,revising Tech Specs Re Dose Equivalent Method of Calculating Radioiodine Activity in Primary Coolant
| ML17345B216 | |
| Person / Time | |
|---|---|
| Site: | Turkey Point |
| Issue date: | 08/18/1983 |
| From: | Robert E. Uhrig FLORIDA POWER & LIGHT CO. |
| To: | Eisenhut D Office of Nuclear Reactor Regulation |
| Shared Package | |
| ML17345B217 | List: |
| References | |
| L-83-451, NUDOCS 8308220311 | |
| Download: ML17345B216 (8) | |
Text
RESULAT(
INFORMATION.DISTRIBUTIONSTER
. (RIDE)
AGCE'S SION NBR s 830822031 DOC ~ DATE 83/08/18 NOTARI'ZED
'NO
,,DOCKET '0 FACIL:50 250 >Turkey Point iPlanti "Uni;t 3r.'Florida IPower'and 'Light 'C 05000250
.'50 251 'Turkey ~Point tPl anti '.Uni,t lli F1 or ida IPower and;Light 'C
~05000251 AUTH' NAME AUTHOR AFFILIATION UHRIGiRB Es
'Fl or.ida IPower 8 -'Light iCo,
~REC I'P ~ NAME RE C IP IENT AF F IL'IATION EI'SENHUT~ D s G ~,
D i visi on of Licensing
SUBJECT:
Application >to -amend.Licenses DPR-31 8.DPR 01irevising,:Tech
'Specs re dose equivalent method of calculating <<radioiodine activi;ty in ~primary coolant'DISTRIBUTION
~CODE:
AQ01S iGOPIES )RECEIyED L'TR, 'iENCL,
'SIZE TITLE:
OR Submi,ttal:
General Distribution NOTES:
RECIPIENT ID CODE/NAME>>
NRR.,ORB1
'BC
'01 INTERNAL: ELD/HOSE NRR/DL DIR ETB EG FILE Og iGOPIES
,L"'TITR ENCL 7
4 7
,0 1
1 1-1
'REC I'P IENT ID iCODE/NAME NRR/DE/MTEB NRR/DL/ORAB NRR/DS I/RAB RGN2 jCOPIES'LT!
TR.ENCL 1'1 0
.1
.1 1
1
.EXTERNAL; ACRS NRC iPDR NTIS 09" 03 6
6 1
1 1
LPDR NSIC.
i03i 05
'-TOTAL NUMBER*.OF 'COP IES REQUIRED:
L'TT'R 25 ENCL 23
a
~
for f r
c q J
r I
l, f
~
II ~
Ij r I.
oil I
I jig f DI>>o r, cS
~ jr
"<< I f I e~'e II D f
n f I I
9 f f <<ir o f
~ g
<<'r D
D<<
D ~
wj Ilf
~,
4 I
J,
~
. O. BOX 14000, JUNO BEACH, FL 33408 8
FLORIDAPOWER & LIGHTCOMPANY August 18, 1983 L-83-451 Office of Nuclear Reactor Regulation Attention:
Nr. Darrell G. Eisenhut, Director Division of Licensing U. S. Nuclear Regulatory Commission Washington, D.C. 20555
Dear Hr. Eisenhut:
Re:
Turkey Point Units 3
5 4 Docket No. 50-250 8 251 Proposed License Amendment Maximum Reactor Coolant Activit In accordance with 10 CFR 50.90, Florida Power
& Light Company submits herewith three signed originals and forty copies of a request to amend Appendix A of Facility Operating Licenses DPR-31 and 41.
This amendment is submitted to replace the existing technical specification requirement with that of the current Standard Technical Specification, as modified by the existing Turkey Point Technical Specification format.
The dose equivalent method of calculating radioiodine activity in the primary coolant as used i n the Standard Technical Specification would significantly reduce the calculated activity compared to the method currently in the Turkey Point 'Unit 3 and 4 Technical Specifications.
The level of primary activity in Turkey Point Unit 3 is rising steadily and can be extrapolated to reach the current Technical Specification limit by the first week of September
- 1983, thereby forcing a plant shutdown four weeks prior to the scheduled refueling outage.
We therefore, request approval of the amendment by September 1,
1983,,
on an Emergency
- basis, per 10 CFR 50.91 (a) (5).
Turkey Point Unit 3 has noted relatively high coolant activity since the beginning of Cycle 8.
- However, the activity levels have significantly increased since June 1983.
We were informed by our fuel vendor, Westinghouse, on August 12, 1983, that the problem of fuel failure. has been occurring else-where throughout the country.
Westinghouse's presentation of fuel failure mechanisms, and the unpredictability of such failures, convinced us that relief from the Technical Specifications was required.
83082203ii 8308i8 PDR ADQCK 05000250 P
PDR gaul I I f
PEOP E
OP'E
0 f
Office of Nuclear Rea or Regulation Attention:
Hr. Darrell G. Eisenhut, Director Page 2
This relief is required for the following reasons:
1)
The overall trend in primary coolant activity is that of a shar'p increase.
This increase could be extrapolated to exceed the Technical Specification limit prior to planned unit shutdown.
2)
The failure mechanism is not well defined, therefore unpredictable.
3)
Any reduction in power will raise the primary coolant activity level.
The next scheduled power reduction is the 30-day test of the
~
Turbine Stop and Control Valves and Reheater Stop and Intercept Valves during the second week of September.
This date includes the grace period allowed by Technical Specifications.
4)
The current Technical Specification is much more conservative than that now approved for use by the NRC.
5)
The current Technical Specification may force the plant to shut down four weeks earlier than, scheduled.
The proposed amendment is descri bed below and shown on the accompanying
'Technical Specification pages.
Paei Kvi Definitions and a
new Figure are added to the tables.
~l-
-i Definitions are added Pa e 3.1-5, 3.1-5a 5 3.1-5b The existing requirements for maximum reactor coolant activity is replaced by those of the Standard Technical Specifications.
. 1-!
A figure of allowable dose-equivalent vs.
power level is included.
Table 4.1-2 -(Sheet 1 of 3) and (Sheet 2 of 3)
Item 1-h, containing special sampling requirements for Isotopic Analyses has been added.
B3.1-5 5 3.1-6 The Bases for the maximum reactor coolant activity has been replaced with those from the Standard Technical Specifications.
The entire Reactor Coolant System Bases has 'been resubmitted.
A Safety Evaluation and Significant Hazards Evaluation as required by 10 CFR 50.91 and 92 is in Attachment A.
II
Office of Nuclear Reactor Regulation Attention:
Mr. Darrell G. Eisenhut, Director Page 3
The proposed amendment has been reviewed by the Turkey Point Plant Nuclear Safety Committee and the Florida Power 8 Light Company Nuclear Review Board.
In accordance with 10 CFR 170.22, it has been determined that this represents a Class I and Class III amendment and a check for payment will follow under separate cover.
Very truly yours, Robert E. Uhrig Vice President Advanced Systems 8 Technology RE U/JEM/1 mg Attachment cc:
J.
P. O'Reilly, Region II Harold F. Reis, Esquire Ulray Clark, Administrator Radiation Health Services Dept. of Health 8 Rehabilitative Services 1323 Winewood Boulevard Tallahassee, Florida 32301 (904) 487-1004
%1