ML17345A852

From kanterella
Jump to navigation Jump to search
Safety Evaluation Supporting Amends 142 & 137 to Licenses DPR-31 & DPR-41,respectively
ML17345A852
Person / Time
Site: Turkey Point  NextEra Energy icon.png
Issue date: 05/20/1991
From:
Office of Nuclear Reactor Regulation
To:
Shared Package
ML17345A851 List:
References
NUDOCS 9106030130
Download: ML17345A852 (4)


Text

~

~AJtkqI 'o 0

C O

I C

a0

~D

/y gO

++**+

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D. C. 20555 SAFETY EVALUATION BY THE OFFICE OF NUCLEAR REACTOR REGULATION RELATED -TO AMENDMENT NO.

TO FACILITY OPERATING LICENSE NO.

DPR-31 AND AMENDMENT N0.137 TO FACILITY OPERATING LICENSE NO.

DPR<<41 FLORIDA POWER AND LIGHT COMPANY TURKEY POINT UNIT NOS.

3 AND 4 DOCKET NOS. 50-250 AND 50-251

1.0 INTRODUCTION

By letter dated October 3, 1990, as superseded February 21, 1991, Florida Power Li'ght Company (FPL) requested changes to Section 6 of the Technical Specifications (TS) for both Turkey Point units.

The proposed amendments would change the title of the corporate executive that has corporate responsibility for overall plant nuclear safety (presently identified in the TS as the Senior Vice President-Nuclear) from the various subsections in which it appears.

The request also proposed changing the composition of the Plant Nuclear Safety Committee (PNSC) to include the Licensing Superintendent as an additional member of the committee.

FPL also proposed changing the title of a PNSC member from Quality Control Supervisor to Quality Control Superintendent.

2.0 EVALUATION The corporate structure of FPL underwent a reorganization.

As a result of that reorganization, the corporate executive responsible for overall plant nuclear safety of the Turkey Point Plant now holds the title of President-Nuclear Division.

Although that corporate executive retained the nominal title of Senior Vice President-Nuclear in order to satisfy the present requirements of the TS, that title now has been functionally eliminated.

Therefore, the licensee requested that the title be changed to President-Nuclear Division.

The requested change does not alter the intent, meaning, or the substance of the TS and reflects only the new corporate organizational titles.

For these

reasons, the change is acceptable.

Similarly, for the same reasons, the proposed change in the title of a member of the PNSC from Quality Control Supervisor to Quality Control Superintendent is also acceptable.

The propose~hange in PNSC membership would add the Licensing Superintendent as a member of the committee'.

Representation of the Licensing Superintendent on the PNSC will significantly improve the TS interpretation and compliance requirements as governed by PNSC responsibilities; therefore, the staff has determined that this change is also acceptable.

9i06030i30 910MO PDR ADOCK 05000250 P

PDR j

r E

3.0 STATE CONSULTATION

Based upon the written notice of the proposed amendments, the Florida State official had no comments.

4.0 ENVIRONMENTAL CONSIDERATION

These amendments relate to changes in recordkeeping or administrative procedures or requirements.

Accordingly, these amendments meet the eligibility criteria for categorical exclusion set forth in 10 CFR 51.22(c)(10).

Pursuant to 10 CFR 51.22(b) no environmental impact statement or environmental assessment need be prepared in connection with the issuance of these amendments.

5.0 CONCLUSION

The Commission has concluded, based on the considerations discussed above, that:

(1) there is reasonable assurance that the health and safety of the public will not be endangered by operation in the proposed

manner, (2) such activities will be conducted in compliance with the Commission's regulations, and (3) the issuance of the amendments will not be inimical to the common defense and security or to the health and safety of the public.

Principal Contributor:

F. Talbot Date:

May 20, 1991

N 4