L-81-313, Application for Amend to App a of Licenses DPR-31 & DPR-40, Allowing Up to 36 Assemblies of Unit 3 Region 10 Fuel to Be Removed from Unit 3 Spent Fuel Pit After Decay Period of 95 Days,Instead of Required 120 Days.Fee Encl

From kanterella
(Redirected from ML17341A390)
Jump to navigation Jump to search
Application for Amend to App a of Licenses DPR-31 & DPR-40, Allowing Up to 36 Assemblies of Unit 3 Region 10 Fuel to Be Removed from Unit 3 Spent Fuel Pit After Decay Period of 95 Days,Instead of Required 120 Days.Fee Encl
ML17341A390
Person / Time
Site: Turkey Point  
Issue date: 07/23/1981
From: Robert E. Uhrig
FLORIDA POWER & LIGHT CO.
To: Eisenhut D
Office of Nuclear Reactor Regulation
Shared Package
ML17341A391 List:
References
L-81-313, NUDOCS 8107310148
Download: ML17341A390 (4)


Text

REGULATOR.

lNFORMATION DISTRIBUTION S I'EH (RIDS)

ACCESSION NBR:8107310148 DOC ~ DATE: 81/07/23 NOTARIZED:

YES

'OCKET ¹ FACIL:50-250 Turkey Point Planti Unit 3i Florida Power and Light C

05000250 50 251 Turkey Point Planti Unit 4i Florida Power and Lignt C

0 AUTH BYNAME AUTHOR AFFILIATION UHRI Gi R ~ E, Florida Power 8 Light Co, REC IP ~ IlAME REC IPIEN i'FFILIATION EISENHUT'PD.G, Division of l.icensing

SUBJECT:

Apolication for amend to Apo A of Licenses DPR 31 8

DPR 40i allowing up to 36 assemolies of Unit. 3 Region 10 fuel to oe removed from Unit 3 spent fuel oit after decay period of 95 aaysiinstead of required 120 days.Fee encl.

DISTRIS'JTIOR CODE:

JIOO IS COPIES RECEIVED:LTR g

ENCL J SIZE: g2 TITLE: General Distribution for after Issuance of Operating License NOTES: g 6fgCg

$1900 RECIPIENT ID CODE/NAHE ACTION:

ORB ¹1 BC 04 INTERNAL: D/DIRiHUH FAC08 IaE 06 OELD 11 RAD ASHT BR COPIES LTTR ENCL 13 13 1

2 2

1 0

1 1

RECIPIENT ID CODE/NAME DIRIDIV OF LIC NRC PDR 02 0

BR 10 REG F

01 COPIES LTTR ENCL 1

1 1

1 0

EXTERNAL: ACRS NSIC 09 05 16 16 1

1 I PDR NTIS 03 1

1 1

TOTAL NUHBE<

OF COPIES REQUlRE,D:

LTTR (

41 ENCL 39

4

'. BOX 529100 i%1IAiVI,F L33 I52 i

Office of Nuclear Reactor Regulation Attention:

Mr. Darrell G. Eisenhut, Director Division of Licensing U.

S.

Nuclear Regulatory Commission Washington, D. C.

20555

Dear Mr. Ei senhut:

Re:

Turkey Point Units 3

8 4 Docket No. 50-250 5 50-251 Proposed License Amendment Fuel Assembl Decay Period FLORIOA POWER Ei LIGHT COMPANY July 23, 1981 L-81-313

~~<5.<h

'UL 3O 8@

QW ~gspH In accordance with 10 CFR 50.30, Florida Power 8 Light Company submits herewith three signed originals and forty copies of a request to amend Appendix A of Facility Operating Licenses DPR-31 and DPR-41.

This amendment is submitted to allow up to 36 assemblies of the Unit 3 Region 10 fuel to be removed from the Unit 3 spent fuel pit after a decay period of 95 days instead of the presently required period of 120 days.

These assemblies were in a

critical reactor at very low power for only approximately 6? 1/2 hours between April 19, 1981 and April 24, 1981 and are to be transferred to the Unit 4 spent fuel pit.

The proposed amendment is described below and shown on the accompanying Technical Specification pages bearing the date of this letter in the lower right hand corner.

3.

2-A footnote changing the decay period for Unit 3 from 120 days to 95 days is added.

We have determined that this is a Class I and Class III request in accordance with 10 CFR 170.

A check for $4,400 is enclosed.

The proposed amendment has been reviewed by the Turkey Point P'lant Nuclear Safety Committee and the Florida Power 8 Light Company Nuclear Review 8oard.

Very truly yours, Robert E. Uhrig Vice President Advanced Systems 8, Technology REU/PLP/ras cc:

Mr. J.

P. O'Reilly, Region II Harold F.

Rei s, Esquire 8107310148 810723 PDR ADOCK 05000250 P

PDR

STATE OF FLORIDA

)

)

COUNTY OF DADE

)

ss Robert E. Uhrig, being first duly sworn, deposes and says:

That he is a Vice President of Florida Power 6 Light Company, the Licensee herein.

That he has executed the foregoing document; that the state-ments made in this said document are true and correct to the best of his knowledge, information, and belief, and that he is authorized to execute the document on behalf of said Licensee.

Robert E.

Unr1g Subscribed and sworn to before me this day of 19J/

NOTARY PUBLXC in and for the county of Dade, State of Florida Not ry Pc'bric.

State of F~dda at Large fb,"y Cor,.m'. "ion Ev'is~ Octet:er 30, 1983 Np COmmiSSiOn Qxpi reS:

Bond~

tftra Shayn rd Bor.d:rg rtgcr'cy