ML17340B418

From kanterella
Jump to navigation Jump to search
Forwards LER 80-011/03L-0
Date released: 07/31/2018 Download: ML17340B418


LER 80-011/03L-0:on 800305,while Conducting Steam Line Area Temp Switch Calibr Surveillance,Temp Switch TS 3-261-17B Tripped Above Tech Specs.Caused by Dirt Deposits on Switch Actuation Plunger.Switch Cleaned,Adjusted & Tested
ML17340B419
Person / Time
Site: Dresden 
Issue date: 03/28/1980
From: Sperroff R
COMMONWEALTH EDISON CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML17340B419 (1)
Forwards LER 80-011/03L-0
ML17340B417
Person / Time
Site: Dresden 
Issue date: 03/28/1980
From: Stephenson B
COMMONWEALTH EDISON CO.
To: KEPPLER J G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML17340B417 (1)