Forwards LER 81-004/03L-0
Date released: 07/31/2018 Download: ML17340B173


LER 81-004/03L-0:on 810322,reactor Trip Resulted from Steam Flow/Feedwater Flow Mismatch Coincident W/Steam Generator a Low Level.Caused by Failed Solenoid Coil on Feedwater Regulator Valve.Evaluation Continuing
ML17340B177
Person / Time
Site: Turkey Point 
Issue date: 04/21/1981
From: Pace P
FLORIDA POWER & LIGHT CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML17340B177 (5)
Forwards LER 81-004/03L-0
ML17340B172
Person / Time
Site: Turkey Point 
Issue date: 04/21/1981
From: Schmidt A
FLORIDA POWER & LIGHT CO.
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML17340B172 (2)