APR c, 8 IS79 APPENDIX A NOTICE OF VIOLATION Florida Pover and Light Company Turkey Point Units 3 and 4 License Nos.
DPR-31 6 DPR-41 Based on the NRC inspection March 19-23, 1979, certain of your activities vere apparently not conducted in full compliance with NRC,requirements as indicated below.
These items have been categorized as described in corre-spondence to you dated December 31, 1974.
A.
As required by Technical Specification 6.11 in conjunction vith Health Physics Procedure HP-60, "Respiratory Protection Manual", no detectable removable contamination is allowed on respirators made available for reissuance.
Contrary to the above, on March 21, 1979, a respirator, Number F68-B, showed levels of removable contamination greater than 3000 disintegrations per minute.
This is an infraction.
B.
As required by 10 CFR 20.203(d) each airborne radioactivity area shall be conspicuously posted vith a sign bearing the radiation caution symbol and the words "Caution Airborne Radioactivity Area".
Contrary to the above, on March 22, 1979, the entrance to the Unit 4 containment vas not posted as an airborne radioactivity area and the concentration of radionuclides exceeded the limits oi 10 CFR 2 Appendix B, Table 1, column 1.
This is a deficiency.