UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 2055&4001 November 16, 1998
~~->a/SfA Mr. Robert P. Powers, Senior Vice President Indiana Michigan Power Compariy Nuclear Generation Group 500 Circle Drive Buchanan, Ml 49107
SUBJECT:
GENERIC LETTER (GL) 97-01, "DEGRADATIONOF CRDM/CEDM NOZZLE AND OTHER VESSEL CLOSURE HEAD PENETRATIONS" REQUEST FOR ADDITIONALINFORMATIONFOR DONALDC. COOK NUCLEAR PLANT, UNITS 1 AND 2 (TAC NOS. M98559 AND M98560)
Dear Mr. Powers:
On April 1, 1997, the staff issued Generic Letter (GL) 97-01, "Degradation of CRDM/CEDM Nozzle and Other Vessel Closure Head Penetrations," to the industry requesting in part that addressees provide a description of the plans to inspect the vessel head penetration nozzles (VHPs) at their respective pressurized water reactor (PWR) designed plants.
With respect to the issuance of the GL, the staff required the addressees to submit an initial response within 30 days of issuance informing the staff of the intent to comply with requested information and a follow-up response within 120 days of issuance containing the technical details to the staffs information requests.
In the discussion section of the GL, the staff stated that "individual licensees may wish to determine their inspection activities based on an integrated industry inspection program...," and indicated that it did not object to individual PWR licensees basing their inspection activities on an integrated industry inspection program.
As a result, the Westinghouse Owners Group (WOG) determined that it was appropriate for its members to develop a cooperative integrated inspection program in response to GL 97-01.
The WOG program is documented in two Topical Reports issued by the Westinghouse Electric Corporation (WEC), WCAP-14901, Revision 0, "Background and Methodology for Evaluation of Reactor Vessel Closure Head Penetration Integrity for the Westinghouse Owners Group," and WCAP-14902, Revision 0, "Background Material for Response to NRC Generic Letter 97-01:
Reactor Vessel Closure Head Penetration Integrity for the Westinghouse Owners Group."
The WOG submitted the integrated programs described in WCAP-14901 and WCAP-14902 to the staff on July 25, 1997.
The staff has determined by letters dated April 29, 1997 (AEP:NRC:1218B), August 1, 1997 (AEP:NRC:1218C), and November 4, 1997 (AEP:NRC:1218D), that you were a member of the WOG and a participant in the WOG integrated program that was developed to address the staff's requests in GL 97-01.
In your letters dated April 29, 1997 (AEP:NRC:1218B), August 1, 1997 (AEP:NRC:1218C), and November 4, 1997 (AEP:NRC:1218D), you also indicated that the information in WEC Topical Report WCAP-14901 is applicable with respect to the assessment of VHP nozzles at the Donald C. Cook Nuclear Plant, Units 1 and 2.
'P8iii80i98,98iii6 PDR ADOCK 050003iS P
PDR K)yi(, gg ))gal~7'V
Mr. Robert P. Powers 4
The staff has reviewed your responses to GL 97-01, dated April29, 1997 (AEP:NRC:1218B),
August 1, 1997 (AEP:NRC:1218C), and November 4, 1997 (AEP:NRC:1218D),
and requires further information to complete its review of your resp'onses as they relate to the WOG's integrated program for assessing VHP nozzles at WOG,member plants, and to the contents of Topical Report No. WCAP-14901. The enclosure to this letter forwards staffs inquiries in the form of a request for additional information (RAI).
The attached request was discussed with Mr. Carl Toth of your staff on November 11, 1998. A mutually agreeable target date of April 15, 1999, for your response was established.
If circumstances result in the need to revise the target date, please cail me at the earliest opportunity.
It should be noted that similar staff requests have been issued to other WOG member utilities. As was the staffs position before, the staff encourages you to address these inquiries in integrated fashion with the WOG and the Nuclear Energy Institute (NEI); however, the staff also requests that you identify any deviations from the WOG's integrated program that may be specific to your facilities. The staff appreciates the efforts expended with respect to this matter.
Sincerely, hn F. Stang, Jr enior Project Manager Project Directorate III-1 Division of Reactor Projects III/IV Office of Nuclear Reactor Regulation
,Docket Nos. 50-315 and 50-316
Enclosure:
Request for Additional Information cc w/encl: See next page
.Mr. Robert P. Powers November 16, 1998 The staff has reviewed your responses to GL 97-01, dated April29, 1997 (AEP:NRC:1218B),
August 1, 1997 (AEP:NRC:1218C), and November 4, 1997 (AEP:NRC:1218D),
and requires further information to complete its review of your responses as they relate to the WOG's integrated program for assessing VHP nozzles at WOG member plants, and to the contents of Topical Report No. WCAP-14901. The enclosure to this letter forwards staffs inquiries in the form of a request for additional information (RAI).
The attached request was discussed with Mr. Carl Toth of your staff on November 11, 1998. A mutually agreeable target date of April 15, 1999, for your response was established.
If circumstances result in the need to revise the target date, please call me at the earliest opportunity.
It should be noted that similar staff requests have been issued to other WOG member utilities. As was the staffs position before, the staff encourages you to address these inquiries in integrated fashion with the WOG and the Nuclear Energy Institute (NEI); however, the staff also requests that you identify any deviations from the WOG's integrated program that may be specific to your facilities. The staff appreciates the efforts expended with respect to this matter.
Sincerely, Original signed by:
- John F. Stang, Jr., Senior Project Manager Project Directorate III-1 Division of Reactor Projects III/IV Office of Nuclear Reactor Regulation Docket Nos. 50-315 and 50-316
Enclosure:
Request for Additional Information cc w/encl: See next page DISTRIBUTION:
Docket File Public PDIII-1r/f ACRS J. Harold
'A. Vegel, Rill
,'GA1 T. Sullivan OGC DOCUMENT.NAME:G:iDCCOOKic098559.RAI To receive a copy of this document, indicate in the box: "C" ~ Copy without Io res, "E" ~ Copy with enclosures "N" ~ No copy OFFICE NAME DATE PM:PDIV-1 C
CNolan 11//5 /98 LA:PDIII-2 g
EBarnhill 11/ I 8-/98 Jst 11/
/98 CCarpenter 11/
/98 PM P I, -1 C
D:PDIII-1 OFFICIALRECgiRD COPY
. Mr. Robert P. Powers November 16, 1998 The staff has reviewed your responses to GL 97-01, dated April 29, 1997 (AEP:NRC:1218B),
August 1, 1997 (AEP:NRC:1218C), and November 4, 1997 (AEP:NRC:1218D),
and requires further information to complete its review of your responses as they relate to the WOG's integrated program for assessing VHP nozzles at WOG member plants, and to the contents of Topical Report No. WCAP-14901. The enclosure to this letter forwards staffs inquiries in the form of a request for additional information (RAI).
The attached request was discussed with Mr. Carl Toth of your staff on November 11, 1998. A mutually agreeable target date of April 15, 1999, for your response was established.
If circumstances result in the need to revise the target date, please call me at the earliest opportunity.
It should be noted that similar staff requests have been issued to other WOG member utilities. As was the staffs position before, the staff encourages you to address these inquiries in integrated fashion with the WOG and the Nuclear Energy Institute (NEI); however, the staff also requests that you identify any deviations fiom the WOG's integrated program that may be specific to your facilities. The staff appreciates the efforts expended with respect to this matter.
Sincerely,-
Original signed by:
John F. Stang, Jr., Senior Project Manager Project Directorate III-1 Division of Reactor Projects III/IV Office of Nuclear Reactor Regulation Docket Nos. 50-315 and 50-316
Enclosure:
Request for Additional Information cc w/encl: See next page
~IS U
0 Docket File Public ACRS J: Harold PDIII-1 r/f A. Vegel, Rill EGA1 T. Sullivan OGC DOCUMENT.NAME G:>DCCOOK<CO98559. RAI To receive a copy of this document, indicate in the box: "C" ~ Copy without lo res "E" ~ Copy with enclosures "N" ~ No copy OFFICE PM:PDIV-1 C
NAME CNolan LA:PDIII-2 g
EBarnhill PMP Jst 1
C D:PDIII-1 CCarpenter DATE 11//Z /98 11/ I 8-/98
/98 11/
/98 OFFICIALREC9RD COPY
Robert P. Powers Indiana Michigan Power Company CC:
Regional Administrator, Region III U:S. Nuclear Regulatory Commission 801 Warrenville Road Lisle, IL 60532-4351 Attorney General Department'of Attorney General 525 West Ottawa Street Lansing, Ml 48913 Township Supervisor Lake Township Hall P.O. Box 818 Bridgman, Ml 49106 U.S. Nuclear Regulatory Commission Resident Inspector's Office 7700 Red Arrow Highway Stevensville, Ml 49127 Jeremy J. Euto, Esquire Indiana Michigan Power Company Nuclear Generation Group 500 Circle Drive Buchanan, Ml 49107 Mayor, City of Bridgman P.O. Box 366 Bridgman, Ml 49106 Special Assistant to the Governor Room 1 - State Capitol Lansing, Ml 48909 Donald C. Cook Nuclear Plant Units 1 and 2 Drinking Water and Radiological Protection Division Michigan Department of Environmental Quality 3423 N. Martin Luther King Jr Blvd P.O. Box 30630 CPH Mailroom Lansing, Ml 48909-8130 Regulatory Affairs Director Indiana Michigan Power Company Nuclear Generation Group 500 Circle Drive Buchanan, Ml 49107 David A. Lochbaum Union of Concerned Scientists 1616 P Street NW, Suite 310 Washington, DC 20036-1495 John R. Sampson, Vice President Indiana Michigan Power Company Nuclear Generation Group One Cook Place Bridgman, Ml 49106
I ~
Request for Additional Information Regarding Utilities Participating in the Westinghouse Owners Group (WOG)
Response to Generic Letter (GL) 97-01 "Background and Methodology for Evaluation of Reactor Vessel Closure Head Penetration Integrity for the Westinghouse Owners Group" Topical Report No. WCAP-14901, Revision 0 Applicabilityof Topical Report No. WCAP-14901, Revision 0, to the Plant-Specific Responses to GL 97-01 for Participating Member Utilities and Plants in the WOG I.
Relationship and Applicabilityof WCAP-14901, Revision 0, to GL 97-01 and the WOG On April 1, 1997, the staff issued Generic Letter (GL) 97-01, "Degradation of CRDM/CEDM Nozzle and Other Vessel Closure Head Penetrations," to the industry requesting in part that addressees provide a description of the plans to inspect the vessel head penetration nozzles (VHPs) at their respective pressurized water reactor (PWR) designed plants.
With respect to the issuance of the GL, the staff required the addressees to submit an initial response within 30 days of issuance informing the staff of the intent to comply with requested information and a follow-up response within 120 days of issuance containing the technical details to the staffs information requests.
In the discussion section of the GL, the staff stated that "individual licensees may wish to determine their inspection activities based on an integrated industry inspection program...," and indicated that it did not object to individual PWR licensees basing their inspection activities on an integrated industry inspection program.
As a result, the WOG determined that it was appropriate for its members to develop a cooperative integrated inspection program in response to GL 97-01. The WOG program is documented in two Topical Reports issued by the Westinghouse Electric Corporation (WEC),
WCAP-14901, Revision 0, "Background and Methodology for Evaluation of Reactor Vessel Closure Head Penetration Integrity for the Westinghouse Owners Group," and WCAP-14902,
. Revision 0, "Background Material for Response to NRC Generic Letter 97-01: Reactor Vessel Closure Head Penetration Integrity for the Westinghouse Owners Group."
The technical content provided in WCAP-14901, Revision 0, is basically the same as that provided in WCAP-14902. The difference with regard to the reports is that WOG member plants subscribing to the content of WCAP-14901 have opted to rank the susceptibility of their vessel head penetrations according to a probabilistic Weibull analysis method that was developed by WEC. In contrast, the WOG member plants subscribing to the content of WCAP-14902, Revision 0, have opted to rank the vessel head penetrations for their facilities according to a probabilistic methodology that was developed by another vendor of choice.
The staff has determined by letters dated April29, 1997 (AEP:NRC:1218B), August 1, 1997 (AEP:NRC:.1218C), and November 4, 1997 (AEP:NRC:1218D), that you were a member of the WOG and a participant in the WOG integrated program that was developed to address the staff's requests in GL 97-01.
In your letters dated April29, 1997 (AEP:NRC:1218B), August 1, 1997 (AEP:NRC:1218C), and November 4, 1997 (AEP:NRC:1218D), you also indicated that the information in WEC Topical Report WCAP-14901 is applicable with respect to the assessment of VHP nozzles at the Donald C. Cook Nuclear Plant, Units 1 and 2.
Enclosure
n, 1 ~.
aa
2 el The staff has reviewed your responses to GL 97-01, dated April 29, 1997 (AEP:NRC:121 8B),
August 1, 1997 (AEP:NRC:1218C), and November 4, 1997 (AEP:NRC:1218D), and requires further information to complete its review of your responses as they relate to the WOG's integrated program for assessing VHP nozzles at WOG member plants, and to the contents of Topical Report No. WCAP-14901. The staff requests the following information with respect to the content'of your responses to GL 97-01, dated April 29, 1997 (AEP:NRC:1218B), August 1, 1997 (AEP:NRC:1218C), and November 4, 1997 (AEP:NRC:1218D), and to the content of WCAP-14901 as it relates to these responses:
1.
In WCAP-14901 WEC did not provide any conclusions as to what the probabilistic failure model would lead the WOG t'o conclude with respect to the assessment of PWSCC in WEC-designed vessel head penetrations.
With respect to the probabilistic susceptibility model (e.g., probabilistic failure model) provided in WCAP-14901:
- a. Provide the susceptibility rankings compiled for the WOG member plants for which WCAP-14901 is applicable.
In regard to other WOG member plants to which WCAP-14901 is applicable, include the basis for establishing the ranking of your plant(s) relative to the others.
- b. Describe how the probabilistic failure model in WCAP-14901 for assessing
, postulated flaws in vessel head penetration nozzles was benchmarked, and provide a list and discussion of the standards the model was benchmarked against.
- c. Provide additional information regarding how the probabilistic failure models in WCAP-14901 willbe refined to allow the input of plant-specific inspection data into the model's analysis methodology.
- d. Describe how the variability in product forms, material specifications, and heat treatments used to fabricate each CRDM penetration nozzle at the WOG member utilities are addressed in the probabilistic crack initiation and growth models described or referenced in Topical Report No. WCAP-14901.
2.
Table 1-2 in WCAP-14901 provides a summary of the key tasks in WEC's vessel head penetration nozzle assessment program.
The table indicates that the tasks for (1) Evaluation of PWSCC Mitigation Methods, (2) Crack Growth Data and Testing, and (3) Crack Initiation Characterization Studies have not been completed and are still in progress.
In light of the fact that the probabilistic susceptibility models appear to be dependent in part on PWSCC crack initiation and growth estimates, provide your best estimate when these tasks willbe completed by WEC, and describe how these activities relate to and will be used to update the probabilistic susceptibility assessment of VHP nozzles at your plant(s).
In the NEI letters of January 29, 1998 (Ref. 1), and April 1, 1998 (Ref. 2), NEI indicated that inspection plans have been developed for the VHP nozzles at the Farley Unit 2 plant in the year 2002, and the Diablo Canyon Unit 2 plant in the year 2001, respectively.
The staff has noted that although you have endorsed the probabilistic susceptibility model described in WCAP-14901, Revision 0, other WOG member licensees have endorsed a probabilistic susceptibility model developed by an alternate vendor of choice. The WOG's proposal to inspect the VHP nozzles at the Farley Unit 2 and Diablo Canyon Unit 2 plants appears to be based on a composite assessment of the VHP nozzles at all WOG member plants. Verifythat such a composite ranking assessment has been applied to the evaluation of VHP nozzles at your plant(s).
Ifcomposite rankings of the VHP nozzles at WOG member plants have been obtained from the composite results of the two models, justify why application of the probabilistic susceptibility model described in WCAP-14901, Revision 0, would yield the same comparable relative rankings of the VHP nozzles for your plant(s) as would application of the alternate probabilistic susceptibility model used by the WOG member plants not subscribing to WCAP-14901, Revision'.
Comment on the susceptibility rankings of the VHP nozzles'at your plant(s) relative to the susceptibility rankings of the VHP nozzles at the Farley Unit 2 and Diablo Canyon Unit 2 plants.
EFER N
1.
January 19, 1998 - Letter from David J. Modeen, Director of Engineering,'Nuclear Generation Division, Nuclear Energy Institute, to Mr. G.C. Lainas, Acting Director, Division of Engineering, Office of Nuclear Reactor Regulation, U.S. Nuclear Regulatory Commission (Untitled).
2.
April 1, 1995 - Letter from David J. Modeen, Director of Engineering, Nuclear Generation Division,'Nuclear Energy Institute, to Mr. G.C. Lainas, Acting Director, Division of Engineering, Office of Nuclear Reactor Regulation, U.S. Nuclear Regulatory Commission,
SUBJECT:
Generic Letter 97-01, 'Degradation of Control Rod Drive Mechanism Nozzle and Other Vessel Head Penetrations.'
v i
la