Application for Amends to Licenses DPR-58 & DPR-74,modifying Tech Specs 3/4.3.1 (Reactor Trip Sys Instrumentation) & 3/4.3.2 (ESFAS Instrumentation) & Bases to Relocate Tables of Response Time Limits to Ufsar,Per GL 93-08
ML17334B546
Person / Time
Site: Cook  
Issue date: 05/26/1995
From: Fitzpatrick E
INDIANA MICHIGAN POWER CO. (FORMERLY INDIANA & MICHIG
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML17332A781 List:
References
AEP:NRC:1210, GL-93-08, GL-93-8, NUDOCS 9506060449
Download: ML17334B546 (10)


Text

cr,~ '>

I yes

!~i, (iI RIORITY 1

CCELERATED RIDS PROCESSING)

REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS) 0 ACCESSION NBR:9506060449 DOC.DATE: 95/05/26 NOTARIZED: YES DOCKET N

FACIL:50-315 Donald C.

Cook Nuclear Power Plant, Unit 1, Indiana M

05000315 50-316 Donald C.

Cook Nuclear Power Plant, Unit 2, Indiana M

05000316 AUTH.NAME AUTHOR AFFILIATION FITZPATRICK,E.

Indiana Michigan Power Co.

(formerly Indiana

& Michigan Ele P

RECIP.NAME RECIPIENT AFFILIATION Document Control Branch (Document Control Desk) 5~

SUBJECT:

Application for amends to licenses DPR-58 6 DPR-74,modifyin tech specs 3/4.3.1 (Reactor Trip Sys Instrumentation)

I 3/4.3.2 (ESFAS Instrumentation)

S bases to relocate tables of response time limits to UFSAR,per GL 93-08.

DISTRIBUTION CODE:

AOOID COPIES RECEIVED:LTR l ENCL 7 SIZE: (0+'VV TITLE: OR Submittal:

General Distribution R

t NOTES:

I RECIPIENT ID CODE/NAME PD3-1 LAJ INTER

FILE CE CH/HICB NRR/DSSA/SRXB OGC/HDS2 EXTERNAL: NOAC COPIES LTTR ENCL 1

1 1

1 1

1 1

1 1

1 1

0 1

1 RECIPIENT ID CODE/NAME PD3-1 PD NRR/DE/EMCB NRR/DSSA/SPLB NUDOCS-ABSTRACT NRC PDR COPIES LTTR ENCL 1

1 1

1 1

1 1

1 1

1 D

C U

N NOTE TO ALL"BIDS" RECIPIENTS:

PLEASE HELP US TO REDUCE iVASTE!CONTACTTHE DOCUMENTCONTROL DESK, ROOM PI-37 (EXT. 504-2083 ) TO ELIXIINATE YOUR XrhiIE PRO%I DISTRIBUTIONLISTS I:OR DOC! 'MENTS YOU DON"I'EED!

TOTAL NUMBER OF COPIES REQUIRED:

LTTR 12 ENCL 11

0:

~

<e 0 'h

Indiana Michigan Power Company P.O. Box 16631 Columbus, OH 43216 5

May 26, 1995 AEP'NRC:1210 Docket Nos.:

50-315 50-316 U.

S. Nuclear Regulatory Commission ATTN:

Document Control Desk Washington, D.

C.

20555 Gentlemen:

Donald C.

Cook Nuclear Plant Units 1 and 2

RELOCATION OF TECHNICAL SPECIFICATION TABLES OF INSTRUMENT RESPONSE TIME LIMITS (GENERIC LETTER 93-08)

This letter and its attachments constitute an application for amendment of the technical specifications (T/Ss) for the Donald C.

Cook Nuclear Plant units 1 and 2.

Specifically, we propose to modify T/Ss 3/4.3.1 (Reactor Trip System Instrumentation) and 3/4.3.2 (Engineered Safety Feature Actuation System Instrumentation) and their accompanying

Bases, to relocate the tables of response time limits to the UFSAR.

These changes are submitted as a line item improvement in accordance with the guidance of Generic Letter 93-08.

Attachment 1 provides a detailed description of the proposed changes, justification for the changes, and our determination of no significant hazards consideration performed pursuant to 10 CFR 50.92.

Attachment 2 contains the existing T/S pages marked to reflect the proposed changes.

Attachment 3 contains the proposed revised T/S pages.

We believe that the proposed changes will not result in (1) a significant change in the types of any effluent that may be released offsite, or (2) a significant increase in individual or cumulative occupational radiation exposure.

The proposed changes have been reviewed by the Plant Nuclear Safety Review Committee and the Nuclear Safety and Design Review Committee.

950b0b0449 95052b PDR ADQCK,050003i5 P

"'DR

0 1

U.

S; Nuclear Regulatory Commission Page 2

AEP'NRC:1210 In compliance with the requirements of 10 CFR 50.91(b)(1),

copies of this letter and its attachments have been transmitted to the Michigan Public Service Commission and to the Michigan Department of Public Health.

Sincerely, Vice President SWORN TO AND SUBSCRIBED BEFORE ME THIS ~~@

DAY OF 1995 Notary Pu lic eh Attachments CC; A. A. Blind G. Charnoff J.

B. Martin NFEM Section Chief NRC Resident Inspector

- Bridgman J.

R. Padgett

0 0

e gQ r

I/~

~r H l

,P ~

ATTACHMENT 1 TO AEP:NRC:1210 JUSTIFICATION AND 10 CFR 50.92 ANALYSIS FOR CHANGES TO THE DONALD C.

COOK NUCLEAR PLANT UNITS 1 AND 2 TECHNICAL SPECIFICATIONS 95O6Q60449 II

ATTACHMENT 1 TO AEP:NRC:1210 Page 1

DESCRIPTION OF CHANGES Units 1

and 2 technical specification (T/S)

Tables

3. 3-2 (Reactor Trip System Instrumentation Response Times) and 3

~ 3-5 (Engineered Safety Features

Response

Times) are deleted.

As discussed

below, the information currently contained in these tables will be relocated to the UFSAR.

2.

Units 1 and 2 T/Ss 3.3.1.1 and 3.3.2.1 are modified to remove reference to Tables 3.3-2 and 3.3-5, respectively.

3.

Units 1 and 2 Bases page B 2-7 is modified to remove specific time response information from the description of the reactor coolant bus undervoltage and underfrequency reactor trips.

4.

Unit 1 Bases page B 3/4 3-1 and unit 2 Bases pages B 3/4 3-1 and B 3/4 3-la are revised to delete discussion of response times designated as "not applicable" and response times associated with RWST and VCT valves.

5.

Units 1 and 2 T/S 4.3.1.1.3 is modified to include a footnote currently located in the response time table (Table 3.3-2).

The footnote states:

"Neutron detectors are exempt from response time testing.

Response

time of the neutron flux signal portion of the channel shall be measured from detector output or input of first electronic component in channel."

Footnotes associated with previous surveillance interval extensions were deleted from Unit 2 pages 3/4 3-1 and 3/4 3-14.

SO D JUSTIF CATION 0

C GES Generic Letter (GL) 93-08 was issued by the NRC to provide guidance to licensees for requesting a license amendment to relocate tables of instrument response time limits from the T/Ss to the UFSAR.

The NRC developed this line item improvement in response to T/S proposals by applicants for operating licenses.

As discussed in the GL, licensees'were encouraged to propose T/S changes that are consistent with the guidance given in the enclosures to the GL.

The limiting conditions for operation (LCOs) for the reactor trip and engineered safety features actuation system (ESFAS) instruments require that these systems be operable with response times as specified in the T/S tables.

The surveillance requirements specify that the licensee test these systems and verify that the response

ATTACHMENT 1 TO AEP'NRC'1210 Page 2

time of each function is within its limits.

Relocating the tables of the reactor trip and ESFAS instrument response time limits from the T/Ss to the UFSAR will not alter these surveillance requirements.

The UFSAR will now address the response time limits for the reactor trip and ESFAS instruments, including those channels for which the response time limit is indicated as "not applicable."

The UFSAR will also clarify response time limits where footnotes are included in the tables that describe how those limits are applied.

This T/S change allows us to administratively control" changes to the response time limits for the reactor trip and ESFAS instruments in accordance with the provisions of 10 CFR 50.59 without the need to process a T/S amendment request.

The present time response surveillance requirements (T/Ss 4.3.1.1.3 and 4.3.2.1.3) do not reference the response time tables.

Therefore, the surveillance requirements did not need to be modified to implement the changes.

However, a footnote in the reactor trip response time table (Table 3.3-2) contains a statement exempting neutron detectors from response time testing.

So that this exemption will be maintained, we have modified surveillance requirement 4.3.1.1.3 to include the text currently in the footnote.

This is in accordance with the recommendations of GL 93-08.

As recommended by GL 93-08, we have confirmed that plant procedures for response time testing include acceptance criteria that reflect the reactor trip and ESFAS.response time limits in the tables being relocated from the T/Ss to the UFSAR.

Following NRC approval, the response time limits will be included in the UFSAR in accordance with 10 CFR 50.71(e).

0 C

50 EV LUAT ON Per 10 CFR 50.92, a

proposed amendment will not involve a

significant hazards consideration if the proposed amendment does not:

(1) involve a

significant increase in the probability or consequences of an accident previously evaluated, (2) create the possibility of a new or different kind of accident from any accident previously evaluated, or (3) involve a significant reduction in a margin of safety.

ATTACHMENT 1 TO AEP:NRC:1210 Page 3

Criterion 1 The proposed changes willnot involve a significant increase in the probability of an accident previously evaluated because the changes will not result in a change to any of the process variables that might initiate an accident.

There are no physical changes to the plant associated with this T/S change.

The consequences of an accident previously evaluated will not be increased because the changes simply allow relocation of response time limits to the UFSAR.

Time response testing will continue to be required by the T/Ss.

Any changes to the response time values will be made in accordance with the requirements of 10 CFR 50.59. It is noted that these T/S changes have previously been determined acceptable by the NRC in GL 93-08.

CRITERION 2 The proposed changes will not create the possibility of a new or different kind of accident from any accident previously evaluated because the changes will involve no physical changes to the plant nor any changes in plant operations.

Time response testing will continue to be required by the T/Ss.

Any changes to the time response values willbe made in accordance with the requirements of 10 CFR 50.59. It is noted that these changes have previously been determined acceptable by the NRC in GL 93>>08.

CRITERION 3 The proposed amendment will not involve a significant reduction in a margin of safety because time response testing will continue to be required by the T/Ss.

Any changes to the response time values will be made in accordance with the requirements of 10 CFR 50.59.

It is noted that these changes have previously been determined acceptable by the NRC in GL 93-08.