ML17334B393

From kanterella
Jump to navigation Jump to search
Application for Amends to Licenses DPR-58 & DPR-74, Consisting of Miscellaneous Administrative Changes to Tech Specs
ML17334B393
Person / Time
Site: Cook  
Issue date: 02/15/1991
From: Alexich M
INDIANA MICHIGAN POWER CO. (FORMERLY INDIANA & MICHIG
To: Murley T
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML17328A924 List:
References
AEP:NRC:1137, NUDOCS 9102220136
Download: ML17334B393 (25)


Text

P.,CCELERATED D RIBUTION DEMONS TION SYSTEM REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)

ACCESSION NBR:9102220136 DOC.DATE: 91/02/15 NOTARIZED: NO DOCKET FACIL:50-315 Donald C.

Cook Nuclear Power Plant, Unit 1, Indiana 6

05000315 50-316 Donald C.

Cook Nuclear Power Plant, Unit 2, Indiana 6

05000316 AUTH.NAME AUTHOR AFFILIATION ALEXICH,M.P.

Indiana Michigan Power Co. (formerly Indiana

& Michigan Ele RECIP.NAME RECIPIENT AFFILIATION R

MURLEY,T.E.

Document Control Branch (Document Control Desk)

SUBJECT:

Application for amends to Licenses DPR-58 6 DPR-74, consisting of miscellaneous administrative changes to Tech Specs.

DISTRIBUTION CODE:

AOOID COPIES RECEIVED:LTR t ENCL i

SIZE: l TITLE: OR Submittal:

General D'ribution NOTES RECIPIENT ID CODE/NAME PD3-1 LA COLBURN,T.

INTERNAL: NRR/DET/ECMB 9H NRR/DOEA/OTSBll NRR/DST/SELB 8D NRR/DST/SRXB 8E 0

EG FI 01 EXTERNAL: NRC PDR COPIES LTTR ENCL 1

1 2

2 1

1 1

1 1

1 1

1 1

0 1

1 1

1 RECIPIENT ID CODE/NAME PD3-1 PD NRR/DET/ESGB NRR/DST 8E2 NRR/DST/SICB 7E NUDOCS-ABSTRACT OGC/HDS2 RES/DSIR/EIB NSIC COPIES LTTR ENCL 1

1 1

1 1

1 1

1 1

1 1

0 1

1 1

1 D

S D

NOTE TO ALL"RIDS" RECIPIENTS:

PLEASE HELP US TO REDUCE WASTE! CONTACT THE DOCUMENT CONTROL DESK, ROOM Pl-37 (EXT. 20079) TO ELIMINATEYOUR NAME FROM DISTRIBUTION LISTS FOR DOCUMENTS YOU DON'T NEED! /y

/'7 TOTAL NUMBER OF COPIES REQUIRED:

LTTR ~

ENCL D

Indiana Michigan Power Company P.O. Box 16631 Columbus, OH 43216 AEP:NRC:1137 Donald C.

Cook Nuclear Plant Units 1 and 2

Docket Nos.

50-315 and 50-316 License Nos.

DPR-58 and DPR-74 MISCELLANEOUS ADMINISTRATIVE TECHNICAL SPECIFICATION CHANGE REQUESTS U.S. Nuclear Regulatory Commission Attn:

Document Control Desk Washington, D.C.

20555 Attn:

T. E. Murley February l5, 1991

Dear Dr. Murley:

This letter constitutes an application for amendment to the Technical Specifications (T/Ss) for the Donald C.

Cook Nuclear Plant:

Units 1 and 2.

Specifically, we are proposing to make miscellaneous administrative changes to the T/Ss of both units.

A description of the proposed

changes, our reasons for the changes, and our analysis concerning significant hazards considerations are included in

'ttachment 1.

The proposed revised T/Ss pages are contained in.

Attachment 3 consists of the existing T/Ss pages marked to reflect how they will be impacted by this proposed amendment.

We believe that the proposed changes will not result in (1) a significant change in the types of effluents or a significant increase in the amounts of any effluent: that may be released offsite, or (2) a significant increase in individual or cumulative occupational radiation exposure.

These proposed changes have been reviewed by the Plant Nuclear Safety Review Committee and by the Nuclear Safety and Design Review Commi.ttee.

In compliance with the requirements of 10 CFR 50.91(b)(1),

copies of this letter and its attachments have been transmitted to Mr. J.

R. Padgett of the Michigan Public Service Commi,ssion and the Michigan Department of Public Health.

9102220136 910215 PDR ADOOK 05000315

-P PDR 4'o~

ga: Q~eA~~/r ei<

li

t

Dr. T. E. Murley AEP:NRC:1137 This document has been prepared folloving Corporate procedures that incorporate a reasonable set of controls to ensure its accuracy and completeness prior to signature by the undersigned.

Sincerely, M.

. Ale ich Vice President eh Attachments cc:

D. H. Williams, Jr.

A. A. Blind - Bridgman J.

R. Padgett G, Charnoff NFEM Section Chief NRC Resident Inspector

- Bridgman A. B. Davis -

NRC Region III

/~

~ 0

~ ~

ATTACHMENT 1 TO AEP:NRC:1137 REASONS AND 10 CFR 50.92 ANALYSES FOR CHANGES TO THE DONALD C.

COOK NUCLEAR PLANT UNIT NOS.

1 AND 2 TECHNICAL SPECIFICATIONS 9 )P2220136

0

~

~

f' W

Attachment 1 to AEP:NRC:1137 Page 1

The proposed changes in this Technical Specifications (T/Ss) change request are purely administrative' description of each proposed change is given below.

1.

Add "121" to Section 2.CD 2.

of Unit 2 License This section of the Unit 2 license was deleted by License Amendment 121.

However, the new page states only the following:

(p) Deleted by Amendment Consequently, we request to revise this phrase to read as follows:

(p) Deleted by Amendment 121 2,

Correct two s ellin mistakes on Unit 2 a

e 1-7 In T/S 1.29 the word "resine" should be "resin."

In T/S 1.32 the word "particulate" should be "particulates'

3

~

Add "avera e" to T S 2.1.1 Units 1 and 2

To make the T/S clearer and more accurate we are proposing to add the word "average" to the Limiting Condition for Operation (LCO).

Currently the T/S reads:

The combination of THERMAL POWER, pressurizer

pressure, and the highest operating loop coolant temperature (Tavg) shall not exceed the limits shown in Figure 2.1-1 for 4 loop operation.

We are proposing to change it to read as follows:

The combination of THERMAL POWER, pressurizer

pressure, and the highest operating loop coolant average temperature (Tavg) shall not exceed the limits shown in Figure 2.1-1 for 4 loop operation.

4.

Delete the hrase "RATED THERMAL POWER 3413 MWT " from Unit 1

~ae 2-2 As part of the analysis Westinghouse performed to support increased steam generator tube plugging, they provided Figure 2.1-1, which was later issued as part of Amendment 152.

To be conservative, Westinghouse assumed a rated thermal power of 3413 MWT, as is stated on T/S page 2-2, Figure 2.1-1.

However, since Unit 1 is actually rated for 3250 MWT, this statement appearing in the T/Ss is very confusing.

The similar table in the Unit 2 T/Ss does not contain this statement.

Consequently, we are proposing to delete this statement from the Unit 1 T/Ss.

V<p

, V I

li g A

"Ql lg

,Jg E

b 1(

Attachment 1 to AEP:NRC:1137 Page 2

5.

Reflect ro er terminolo in Table 2.2-1 Units 1 and 2

We are proposing to change the wording for functional unit 17 '

in Table 2.2-1 from "Low Trip System Pressure" to "Low Fluid Oil Pressure."

This change is proposed to make the T/S clearer by reflecting proper terminology.

In addition, we are changing the orientation of this table from horizontal to vertical.

6.

Correct t o ra hical error in Unit 2 T S 3.2.1 LCO The Unit 2 T/S 3.2.1 LCO currently refers to the "target ban."

This should be changed to "target band."

7.

Correct inconsistenc in Unit 1 T S Table 3.3-5 Item 7 d T/S 4.6.5.6(a) requires the containment air recirculation fans to automatically start in 9 +

1 minutes after receiving a high-high containment pressure signal.

Table 3.3.5 gives a

maximum response time of less than or equal to 660 sec.

This should be changed to less than or equal to 600 sec.

Unit 2 is already correct.

In addition, we are writing out "less than or equal to" throughout this page of the table.

8.

Correct discre anc in Unit 2 T S Table 3.3-1 In the Unit 2 T/Ss, for item 22 of Table 3.3-1, Actions 1 and 14 are listed such that they refer to'Modes 1, 2, 3, '4, and 5.

We are revising item 22 such that Action 1 refers to Modes 1 and 2 and Action 14 refers to Modes 3, 4, and 5.

This is consistent with Unit 1.

In addition, we are changing the orientation from horizontal to vertical for all three pages of this table.

9.

Correct editorial error on Unit 1 a

e 3

4 3-33 Functional unit 4.d currently reads:

d.

Steam Flow in Two Steam Lines--

High Coincident with Tavg--Low-Low Pressure--Low

~ I lu

Attachment 1 to AEP:NRC:1137 Page 3

This should be broken into two functional units, as is the case for Unit 2.

We propose the following:

d.

Steam Flow in Two Steam Lines--

High Coincident with Tavg--Low-Low e

~

Steam Line Pressure--

Low 10.

Delete reference to reviousl deleted T

S in Table 3.3-6 Units 1 and 2

Currently Action 22A-3 and Action 22B-4 in Table 3.3-6 state:

Technical Specification Sections 3.0.3, 3.0.4 and 6.9.1

~ 13 Not Applicable.

However T/S 6.9.1.13 has been deleted by a previous amendment.

Consequently, we are requesting to change Action 22A-3 and Action 22B-4 to state:

Technical Specification Sections 3.0.3 and 3.0,4 Not Applicable.

11.

Correct elevation in Unit 1 Table 3.3-10 and Unit 2 Table Item a under the heading "Auxiliary Building" in Unit 1 Table 3.3-10 incorrectly lists elevation 587.

The correct listing for item a is elevation 573.

Item d under the heading "Auxiliary Building" in Unit 2 Table 3,3-11 lists elevation

587, when elevation 573 should be listed first (it is the lowest elevation).

Therefore, item d has become item a and items a

through f are relettered accordingly, 12, Correct terminolo in Unit 1 T S Table 3.3-11 and Unit 2 T S Table 3.3-10 Item 11 in these tables refers to a footnote that says,

"~PRODAC250 subcooling margin readout can be used as a

substitute for the subcooling monitor instrumentation."

Reference to the "PRODAC 250" is interpreted to be the plant process computer (PPC).

The PRODAC 250 computer was replaced by the new PPC

~

Consequently, we are proposing to revise the subject phrase to read as follows:

"PPC subcooling margin readout can be used as a substitute for the subcooling monitor instrument."

Qi

Attachment 1 to AEP:NRC:1137 Page 4

In addition, we are deleting the following note from the bottom of the Unit 1 page, since it is no longer applies:

Amendment No, 112 (Effective before startup following the refueling outage currently scheduled in August 1989),

Likewise, this note. should be deleted from the Unit 2 page:

Amendment No.

95 (Effective before startup following refueling outage currently scheduled in early 1988).

13.

Correct cross reference in T S

3 4.4.11.3 Units 1 and 2

Amendment 125 to Unit 1 and 112 to Unit 2 added new surveillance requirements and rearranged the order of the surveillances listed in T/S 4,8.11.2.

This has resulted in improper cross references being given in T/S 3/4.4.11.

For Unit 1, reference to 4.8.1.1.2b is incorrect and should be revised to 4.8.1.1.2e.

For Unit 2, reference to 4.8.1,1.2c is incorrect and should be revised to 4.8.1.1.2e.

14.

Make 2 5 4.5.2 consistent between units and provide clarification revise Unit 2 At present, Unit 2 T/S 4.5.2(a) says:

At least once per 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> by verifying that the following valves are in the indicated positions with power to the valve operator removed:

This wording implies that the valve motor breaker is to be open.

In reality the breaker is closed but control power is removed.

The same specification in Unit 1 is worded correctly.

Consequently, we are proposing to make Unit 2 read like Unit 1, as follows:

At least once per 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> by verifying that the following valves are in the indicated positions with the control power locked out.

15 'elete Unit 1 a

e 3

4 5-6a This page should have 'been deleted by Amendment No. 126.

The information on Unit 1 T/S page 3/4 5-6a has been superseded by that on page 3/4 5-6.

Consequently, we are requesting that page 3/4 5-6a be deleted.

,P l

Attachment 1 to AEP:NRC:1137 Page 5

16.

Make T S

3 4 6.1.3 consistent between units Units 1 and 2

To clarify T/S 4.6.1.3.b for both units, we wish to change the partial sentence "After each opening, except when the air lock is being used for multiple entries, when it shall be done at least once per 3 days, by performing

.." to "Within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> following each closing, perform We also propose the following editorial changes:

o T/S 3.6.1.3(b),

both units, write out "less than or equal to" o

T/S 3 '.1.3(b), Unit 2, change "12.0" to "12" o

T/S 4.6.1.3(c), Unit 1, replace the word "gap" with "volume" o

T/S 4,6.1.3(c), Unit 2, delete the commas and insert parentheses around "12 psig."

17.

Delete re eated lines on Unit 1 a

e 3 4 6-15 We are proposing to delete the following lines from the top of page 3/4 6-15 since they appear on the bottom of page 3/4 6-14:

valve or its associated

actuator, control or power circuit by performance of the cycling test,
above, and verification of isolation time.

h 18.

Chan e the described function of items in Table 3.6-1 to reflect ro er terminolo Units 1 and 2

For valves listed as items D.3 through D.6 in Table 3.6-1 the term "inlet" is used to describe the function of the valve.

The terms "inlet" and "outlet" are relative, depending on your frame of reference, At Cook Nuclear Plant we typically use the term "inlet" to refer to the reactor coolant pump inlet.

The proper terminology for these valves should be "outlet," since they are at the outlet of the boron injection tank.

R I

FW

Attachment 1 to AEP:NRC:1137 Page 6

Consequently, we are requesting to change the table from:

3.

ICM - 250 4.

ICM - 251 5.

ICM - 260 6.

ICM - 265 Boron Injection Inlet Boron Injection Inlet Safety Injection Inlet Safety Injection Inlet tol 3

~

ICM - 250 4.

ICM - 251 5.

ICM - 260 6.

ICM - 265 Boron Injection Outlet Boron Injection Outlet Safety Injection Outlet Safety Injection Outlet In addition, Items D.7 and D.8,contain an incomplete description of the valve's function.

In both cases the description currently reads "RHR Suction From Sump." It should read "RHR/CTS Suction From Sump."

19.

Provide clarification to 3.7.1.2 Units 1 and 2

Currently T/S 3,7,1.2(a) 1 and 2 read as follows:

1.

Two feedwater

pumps, each capable of being powered from separate emergency
busses, 2.

One feedwater pump capable of being powered from an OPERABLE steam supply system.

We wish to revise T/S 3.7,1.2(a) as follows to provide clarification:

1.

Two motor-driven auxiliary feedwater

pumps, each capable of being powered from separate emergency
busses, and r

2.

One steam turbine-driven auxiliary feedwater pump capable of being powered from an OPERABLE steam supply system.

20.

Correct t o ra hical error in T S

3 4.8.3 Unit 2 Currently the footnote says "Unit 2".

This should be changed to say "Unit 1".

21.

Delete non a licable T S surveillance re uirement from T S

4.9 '.1 Units 1 and 2

Currently T/S 4.9.7 '

reads as follows:

Crane interlocks and physical stops which prevent crane travel with loads in excess of 2,500 pounds over fuel

0 l

1,

Attachment 1 to AEP:NRC:1137 Page 7

assemblies shall be demonstrated OPERABLE within 7 days prior to crane use and at least once per 7 days thereafter during crane operation.

The requirement to verify both interlocks and physical stops on the auxiliary building crane within seven days prior to crane use whenever fuel is stored in the pit was taken directly from NUREG-0452, "Standard Technical Specifications for Westinghouse Pressurized Water Reactors,"

and is not totally applicable to Cook Nuclear Plant, The auxiliary building crane is not equipped with physical stops.

As such, this T/S has been interpreted such that verification of the electrical interlocks alone constitutes compliance.

Thus, we are proposing to delete this requirement, so that T/S 4.9 '.1 will state; Crane interlocks which prevent crane travel with loads in excess of 2,500 pounds over fuel assemblies shall be demonstrated OPERABLE within 7 days prior to crane use and at least once per 7 days thereafter during crane operation.

In addition, in the footnote we are changing "D.CD COOK - UNIT" to "Cook Nuclear Plant - Unit" ~

22.

Delete asterisk from T S 3.9.9 Unit 2 The first line of the action statement of Unit 2 T/S 3.9.9 reads:

With the Containment Purge and Exhaust isolation system+

inoperable, The asterisk after the word "system" was not deleted as part of Amendment No.

63 when the footnote was removed.

Consequently, we are proposing to delete the asterisk in this submittal.

23.

Ca italize defined term in T S 5.1.3 'nits 1 and 2

Technical Specification 5.1.3 currently reads as follows:

The site boundary for gaseous and liquid effluents shall be shown in Figure 5.1-3

However, the term "site boundary" is defined in T/S 1.3.6.

'Per T/S 1.1, defined terms should appear in capitalized type and we are therefore proposing to revise T/S 5.1.3 as follows:

The SITE BOUNDARY for gaseous and liquid effluents shall be shown in Figure 5.1-3.

ij tj,

"=

1 <<,II.

SI i,

id 4

Attachment 1 to AEP:NRC:1137 Page 8

24.

Correct t o ra hical error in Unit 1 T S 6.5.1.6 a

Ve propose to correct the spelling of "proceudres" to "procedures."

25.

Correct terminolo in T S 6.4 T/S 6.4 should be revised to reference Subpart "A" of 10 CFR Part 55, not Appendix "A" of 10 CFR Part 55.

Im act on Pendin Submittals Several of the technical specifications that we are proposing to change in this submittal are the subject of submittals pending NRC review and approval.

These technical specifications and the submittals that impact them are as follows:

Unit 1 Table 3.3-5 Table 4.3-2 T/S 3/4.7.1.2 T/S 6.5.1.6 T/S 6'.1 Unit 2 T/S 3/4.7.1.2 T/S 6.4.1 AEP:NRC:1030 AEP:NRC:0433N AEP:NRC:0659M AEP:NRC:0433N AEP:NRC:0659M 03/14/89 08/07/90 08/25/89 08/07/90 08/25/89 Anal sis of Si nificant Hazards Per 10 CFR 50 '2, a proposed amendment will involve no significant hazards considerations if the proposed amendment does not:

(1) involve a significant increase in the probability or consequences of an accident previously evaluated, (2) create the possibility of a new or different kind of accident from any accident previously analyzed or evaluated, or (3) involve a significant reduction in a margin of safety,

t~

Attachment 1 to AEP:NRC:1137 Page 9

Criterion 1 The proposed changes are purely administrative and are intended to correct errors or problems in the T/Ss.

Therefore, we believe these changes do not involve a significant increase in the probability or consequences of a previously analyzed accident.

Criterion 2

Since the proposed changes are purely administrative and introduce no new operating conditions, we believe that these changes will not create the possibility of a new or different kind of accident, from any previously analyzed or evaluated.

Criterion 3

For the reasons cited in Criterion 1 above, we believe that the proposed changes will not result in a significant reduction in the margin of safety,

Lastly, we note that the Commission has provided guidance concerning the determination of significant hazards by providing certain examples of amendments not likely to involve significant hazards considerations.

The first example is that of a purely administrative change to the T/Ss; for example, a change to achieve consistency throughout the T/Ss, correction of an error, or change in nomenclature.

We believe that the changes requested in this letter are of the type specified in this example, since they are intended to correct errors and problems in the T/Ss.

Therefore, we believe this change involves no significant hazards considerations as defined in 10 CFR 50.92

1f fr I