ML17334B353

From kanterella
Jump to navigation Jump to search
Forwards Rev 2 to DC Cook Nuclear Plant Units 1 & 2 Inservice Testing Pump Program, Rev 3 to DC Cook Nuclear Plant Unit 2 Inservice Testing Valve Program & Rev 3 to DC Cook...Unit 1...Program... in Response to 890829 SER
ML17334B353
Person / Time
Site: Cook  
Issue date: 02/16/1990
From: Alexich M
INDIANA MICHIGAN POWER CO. (FORMERLY INDIANA & MICHIG
To: Murley T
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML17334B354 List:
References
AEP:NRC:0969R, AEP:NRC:969R, NUDOCS 9003090172
Download: ML17334B353 (5)


Text

.A.C CE1Z RA,FED D1 BUT1 ON DEMONS TIOYi SYSTEM REGULAT INFORMATION'DISTRIBUTION ZSTEM (RIDS)

ACCESSION NBR:9003090172 DOC.DATE: 90/02/16 NOTARIZED: NO DOCKET g FACIL:.50=315:Donald=C.

Cook=Nuclear Power Plant

., Unit:1, India'na 050003l5W 50-316 Donald C.

Cook Nuclear Power Plant, Unit 2, Indiana 05000316 AUTH.NAME AUTHOR AFFILIATION ALEXICH,M.P.

Indiana Michigan Power Co. (formerly Indiana

& Michigan Ele RECIP.NAME RECIPIENT AFFILIATION MURLEY,T.E.

Document Control Branch (Document Control Desk)

SUBJECT:

Forwards Rev 2 to "DC Cook Nuclear Plant Units 1

2 Inservice Testing Pump Program,"

Rev 3 to "...Unit 2 IST....

DISTRIBUTION CODE:

A047D COPIES RECEIVED:LTR l

ENCL /

SIZE:

+ 3/W TITLE: OR Submittal: Inservice Inspection/Testing/Relief from ASME Code NOTEB:%~~M+ 4 RECIPIENT ID CODE/NAME PD3-1 LA GIITTER,J.

INTERNAL: AEOD/DSP/TPAB NRR/DET/EMEB 9H O~

E ILE 01 EXTERNAL: EG&G BROWNgB LPDR NSIC COPIES LTTR ENCL 1

0 1

1 1

1 1

1 1

0 1

1 1

1 1

1 1

1 RECIPIENT ID CODE/NAME PD3-1 PD NRR/DET/ECMB 9H NUDOCS-ABSTRACT OGC/HDS1 RES/DSIR/EIB EG&G RANSOMEgC NRC PDR COPIES LTTR ENCL 1

1 1

1' 0

1 1

1 1

1 1

S h

NaTE 'ZO ALL "RIES" RECIPIEFZS:

PIZASE HELP US IO RKZQCE KQi~.'GMI'ACT'IHE DOCUMEÃZ CONTROL DESK, RDCN Pl-37 (EXT. 20079)

'IQ EZiZMZICQR YOUR NAME PMM DIPHGBVZIQN LISTS FOR DOCUMEWIS YOU DONIT NEEDt t

D S

TOTAL NUMBER OF COPIES REQUIRED:

LTTR 20 ENCL

t 1

0 4

I y

Indiana Michigan Power Company P.O. Box 16631 Columbus, OH 43216 AEP:NRC:0969R Donald C.

Cook Nuclear Plant Units 1 and 2

Docket Nos.

50-315 and 50-316 License Nos

~

DPR-58 and DPR-74 REVISED SECOND 10-YEAR INSERVICE TEST PROGRAM U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D.C.

20555 Attn: T.

E. Murley February 16, 1990

Dear Dr. Murley:

This letter and its attachments are provided in response to the NRC Safety Evaluation Report (SER) dated August 29,

1989, and the Supplemental Safety Evaluation Report dated November 28,
1989, issued for the Second 10-Year Inservice Test (IST) Program for pumps and valves at the Donald C.

Cook Nuclear Plant.

This submittal provides the additional technical justification and suggested revisions agreed upon in a meeting between the NRC staff and AEPSC on November 8, 1989.

The attachments to this letter are as follows:

Attachment 1 - Inservice Testing Program for Pumps

- Units 1 and 2, Revision 2 dated February 5,

1990 Attachment 2

- Inservtce Testing Program for Valves

- Unit 1, Revision 3 dated February 5, 1990 Attachment 3 - Inservice Testing Program for Valves

- Unit 2, Revision 3 dated February 5,

1990 Attachment 4 - Summary of Revision 2, IST Pump Program and Revision 3, IST Valve Program

)0 C

f73 0

C The first three attachments contain the revised IST Program for the second 10-year interval for pumps and valves.

This submittal replaces the IST Pumps and Valve Program submitted in AEP:NRC:0969H dated October 5, 1987.

A brief summary of the changes that have been made to the IST Pump and Valve Program are contained in the fourth attachment.

The attachment has been divided into three sections with the first pDR ADDCK 050003Ui5 F'

Dr. T.

E. Murley AEP:NRC:0969R section responding to Enclosure 3 of the Supplemental Safety Evaluation Report dated November 28, 1989.

The second section addresses the revisions made to the program for clarification and consistency to alleviate anomalies identified in the Safety Evaluation Report dated August 28, 1989.

Section 3 addresses additional refinements that have been made as a result of the latest review of the program.

This letter has been reviewed by the Plant Nuclear Safety Review Committee and will be by the Nuclear Safety and Design Review Committee at its next regularly scheduled meeting.

This letter has been prepared following Corporate procedures that incorporate a reasonable set of controls to ensure its accuracy and completeness prior to signature by the undersigned.

Sincerely, M. P. Alexich Vice President ldp Attachments cc:

D. H. Williams, Jr.

A. A. Blind - Bridgman R.

C. Callen G. Charnoff A. B. Davis

- Bridgman NRC Resident Inspector

- Bridgman NFEM Section Chief

0 ill