ML17334B176

From kanterella
Jump to navigation Jump to search
Forwards Corrected Pages 1,2 & 5 of Chemical Composition Table Submitted w/870112 Response to NRC Compliance Bulletin 87-002 Re safety-related & nonsafety-related Fastener Testing
ML17334B176
Person / Time
Site: Cook  
Issue date: 01/27/1988
From: Alexich M
INDIANA MICHIGAN POWER CO. (FORMERLY INDIANA & MICHIG
To: Davis A
NRC, NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM)
References
AEP:NRC:1045A, IEB-87-002, IEB-87-2, NUDOCS 8802020202
Download: ML17334B176 (5)


Text

REGULATOR.

NFORMATION DISTRIBUTION S%FI'EM (RIDS)

ACCESSION NBR:8802020202 DOC. DATE: 88/01/27 NOTARIZED:

NO DOCKET FACIL: 50-315 Donald C.

Cook Nuclear Power Planti Unit iI Indiana Sc 05000315 50-318 Calvert Cliffs Nuclear Power Planti Unit 2I Baltimore 05000318 AUTH. NAME AUTHOR AFFILIATION ALEXICHI M. P.

Indiana Michigan Power Co.

REC IP. NAME RECIPIENT AFFILIATION DAVIST A. B.

Document Control Branch (Document Control Desk)

SUBJECT:

Forwards corrected Pages 1I 2 5 5 of chemical composition table submitted w/870112 response to NRC Compliance Bulletin 87-002 re safety-related 8c nonsafetg-related fastener testing.

DISTRIBUTION CODE:

IE11D COPIES. RECEIVED'TR i ENCL J SIZE:

TITLE: Bulletin Response (50 DKT)

NOTES:

RECIPIENT ID CODE/NAME PD3-3 LA PD3-3 PD WIGGINGTONI D INTERNAL: AEOD/DOA AEOD/DSP/TP*B NRR/DEST/ADS NRR/DOEA/EAB NRR/ RE~PB REG ILB 02 RGN1 FILE 01 EXTERNAL:

LPDR NSIC CQP IES LTTR ENCL 1

0 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

2 2

1 RECIPIENT ID CODE/NAME PD1-1 PD PDi-1 PD MCNEILIS AEQD/DSP NRR/DEST/ADE NRR/DEBT/MEB NRR/DOEA/GCB NRR/PMAS/ ILRB RES/DE/EIB RGN3 FILE 01 NRC PDR I

COPIES LTTR ENCL 1

0 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

TOTAL NUMBER OF COPIES REQUIRED:

LTTR 24 ENCL 22

Indiana Michigan Power Company P.O. Box 16631 Columbus, OH 432 I6 INDIANA NICHIGAN POWER AEP:NRC'1045A Donald C.

Cook Nuclear Plant Units 1 and 2

Docket Nos.

50-315 and 50-316 License Nos.

DPR-58 and DPR-74 NRC COMPLIANCE BULLETIN NO. 87-02'ASTENER TESTING TO DETERMINE CONFORMANCE WITH APPLICABLE MATERIAL SPECIFICATIONS-RESUBMITTAL OF THREE PAGES U.S. Nuclear Regulatory Commission Attn:

Document Control Desk Washington, D.C.

205555 Attn:

A. B. Davis January 27, 1988

Dear Mr. Davis:

Our submittal AEP:NRC:1045 dated January 12, 1987 responded to the information required by NRC Compliance Bulletin 87-02 on safety-related and nonsafety-related fastener testing.

Attachment 2 to that submittal contained the mechanical/chemical test results of the sample of fasteners tested.

Inadvertently, three pages of the chemical composition table were not printed properly as the data was shifted too far to the right side of the pages (pages 1,

2, and 5).

We are transmitting these three pages in this submittal.

Please replace the previously transmitted pages with the attached pages.

We apologize for any inconvenience that this may have caused.

This document has been prepared following Corporate procedures which incorporate a reasonable set of controls to ensure its accuracy and completeness prior to signature by the undersigned.

, Sincerely, M. P.

A exich Vice President cm cc:

John E. Dolan W.

G. Smith, Jr.

- Bridgman R.

C. Callen G.

Bruchmann G. Charnoff NRC Resident Inspector

- Bridgman 8802020202 880l27 PDR ADQCK 050003i5 G

PDR

ATTACHMENT 2 DONALD C.

COOK NUCLEAR PLANT Data Summary SA-193 Gr B7 Bolts/Studs Safety-Related AEP:NRC:1045 Page 1

IDQ Mechanical Anal sis Hardness UTS si 0.2%

YS si Chemical Anal sis Mn Si Mo Cr DCCNP/30-028980/

ASP9708 30.5 Rc 141,500 124,300 0.37 0.72 0.010 0.013 0.22 0.20 0.87 DCCNP/30-029918/

ASP6071 29.5 Rc 133,100 113,200 0.40 0.91 0.012 0.016 0.25 0.21 0.98 DCCNP/30-046489/

ASP9735 27.5 Rc 135,700 116,300 0.35 0.89 0.011 0.016 0.23 0.20 0.88 DCCNP/30-046542/

ASP6110 32 Rc 143,300 127,800 0.44 0.89 0.007 0.023 0.23 0.21 1.04 DCCNP/30-046403/

ASP9673 29 Rc 138,000 122,700 0.40 0.84 0.006 0.023 0.17 0.20 0.93 Note:

UTS - Ultimate Tensile Strength; YS - Yield Strength; C - Carbon; Mn - Manganese; P - Phosphorus; S

- Sulfur; Si - Silicon; Mo - Molybdenum; Cr - Chromium.

AEP NRC 1045 Page 2

ATTACHMENT 2 DONALD C.

COOK NUCLEAR PLANT Data Summary SA-193 Gr B8 Boles/Studs Safety-Related IDO Mechanical Anal sis Hardness UTS si 0.2%

YS si Chemical Anal sis C

Mn P

S Si Ni Cr DCCNP/30-029989/

ASP9828 89 Rb 83,600 37,400 0.03 1.62 0.025 0.033 0.83 9.44 18.26 DCCNP/30-046730/

ASP4184 87 Rb 106,400 51,000 0.06 0.81 0.013

<0.005 0.65 8.30 18.85 DCCNP/30-046785/

ASP4184 89 Rb 90,900 47,000 0.05 1.78 0.031 0.015 0.47 9.09 18.81 Note:

UTS - Ultimate Tensile Strength; YS - Yield Strength; C - Carbon; Mn - Manganese; P - Phosphorus; S - Sulfur; Si - Silicon; Ni - Nickel; Cr - Chromium.

ATTACHMENT 2 DONALD C.

COOK NUCLEAR PLANT AEP:NRC:1045 p

Page 5

Data Summary SA-194 Gr 2H Heavy Hex Nuts'afety-Related Mechanical Anal sis Chemical Anal sis ID¹ DCCNP/30-028980/

ASP9708 Hardness Nut A Nut B 32 Rc 32 Rc 0.47 0'5 0.014 0.012 0.024 0.022 DCCNP/30-029918/

ASP6071 Nut A Nut B DCCNP/30-046625/

ASP3693 26 Rc 26 Rc 31 Rc 0.46 0.46 0.44 0.007 0.007 0.019 0.025 0.025 0.012 DCCNP/30-046627/

ASP3631 27 Rc 0.42 0.021 0.022 DCCNP/30-046622/

ASP9224 32.5 Rc 0.44 0.010 0.023 Note:

C - Carbon; P - Phosphorus; S

- Sulfur