ML17334A740

From kanterella
Jump to navigation Jump to search
Forwards Special RP Insp Repts 50-315/98-13 & 50-316/98-13 on 980601-02 & Nov.Violation Re Failure to Notify RP of Open Wound Prior to Entry Into Radiologically Controlled Area
ML17334A740
Person / Time
Site: Cook  American Electric Power icon.png
Issue date: 06/09/1998
From: Grobe J
NRC (Affiliation Not Assigned)
To: Sampson J
AMERICAN ELECTRIC POWER CO., INC.
Shared Package
ML17334A741 List:
References
50-315-98-13, 50-316-98-13, NUDOCS 9806150236
Download: ML17334A740 (8)


See also: IR 05000315/1998013

Text

CATE(HUH.X

. 4 ~

REGULATORY INFORMATION DISTRIBUTION SYSTEM

(RIDS)'ESSION

NBR:9806150236

,

DOC.DATE: 98/06/09

NOTARIZED: NO

DOCKET ¹

ACIL:50-315 Donald C. Cook Nuclear Power Plant, Unit 1, .Indiana

M

05000315

50-316 Donald C.

Cook Nuclear Power Plant, Unit 2, Indiana

M

05000316

AUTH.NAME

'UTHOR AFFILIATION

GROBE,J.A.

RECIP.NAME

RECIPIENT AFFILIATION

SAMPSON,J.

American Electric Power Co., Inc.

C

SUBJECT:

Forwards special

RP insp repts

50-315/98-13

5: 50-316/98-13

on 980601-02.0ne violation of NRC recpxirements identified re

A

failure to notify RP of open wound prior to entry into

radiologically controlled area;

T

DISTRIBUTION CODE'E06F

COPIES

RECEIVED'LTR

f ENCLj SIZE'~

TITLE: Environ

6 Radiological

(50 DKT)-Insp Rept/Notice of Violation Respons

G

NOTES:

RECIPIENT

ID CODE/NAME

PD3-3

PD

INTERNAL: AEOD/TTC

NMSS/SFPO

06F18

NUDOCS-ABSTRACT

OGC/HDS3

ERNAL: NOAC

NUDOCS FULLTEXT

COPIES

LTTR ENCL'

1

1

1

1

1

1

1

1

1

1

1

1

1

RECIPIENT

ID CODE/NAME

STANG,J

LE CENTE~

/5%M/PZZ8'E

DIR

RGN3

FILE

01

NRC PDR

COPIES

LTTR ENCL

1

1

1

1

1

1

1

1

1

1

1

1

R

M@~eom

) NlAC FLQPPQ

NOTE TO ALL "RIDS" RECIPIENTS:

PLEASE HELP US TO REDUCE WASTE. TO HAVE YOUR NAME OR ORGANIZATION REMOVED FROM DISTRIBUTION LIST.

OR REDUCE THE NUMBER OF COPIES RECEIVED BY YOU OR YOUR ORGANIZATION, CONTACT THE DOCUMENT CONTROI

DESK

(DCD)

ON EXTENSION 415-2083

TOTAL NUMBER OF COPIES

REQUIRED:

LTTR

. 13

ENCL

13

0

June 9,

1998

Mr. John Sampson

Site Vice President

Nuclear Generation Group

American Electric Power Company

500 Circle Drive

Buchanan, Ml 49107-1395

SUBJECT:

NRC SPECIAL RADIATIONPROTECTION INSPECTION REPORTS

50-315/98013(DRS); 50-316/98013(DRS) AND NOTICE OF VIOLATION

Dear Mr. Sampson:

On June 2, 1998, the NRC completed a special inspection, at your D. C. Cook, Units 1 and 2

reactor facilities. The enclosed report presents the results of that inspection.

The inspection was an examination of activities conducted under your license as they relate to

radiation safety and to compliance with the Commission's rules and regulations and with the

conditions of your license.

The purpose of the inspection was to follow up on an event where a

worker entered containment with an open wound without prior notification of the presence of the

wound to radiation protection personnel.

The enclosed report documents the results of the

inspection.

One violation of NRC requirements was identified, as specified in the enclosed Notice of

Violation (Notice). The violation concerned the failure to notify radiation protection of an open

wound prior to entry into a radiologically controlled area.

This violation is of concern because

there were several opportunities to notify radiation protection of the wound. Neither the worker,

his foreman, or the safety supervisor notified radiation protection of the presence of the wound.

The NRC has concluded that information regarding the reason for the violation, the corrective

actions taken and planned to correct the violation and prevent recurrence,

is already adequately

addressed

in the subject inspection report. Therefore, you are not required to respond to this

violation unless the description of the problem as described in the inspection report does not

accurately reflect your corrective actions or your position.

In that case, or ifyou choose to

provide additional information, you should follow the instructions specified in the enclosed

Notice.

In accordance with 10 CFR 2.790 of the NRC'S "Rules of Practice," a copy of this letter, the

enclosures, and your response to this letter, ifyou choose to provide one, willbe placed in the

NRC Public Document Room (PDR).

9806iS0236

9S0609'DR

ADOCK 05000315

8

PDR

J. Sampson

We willgladly discuss any questions you have concerning this inspection.

Sincerely,

Original Signed

by John A. Grobe

John A. Grobe, Director

Division of Reactor Safety

Docket Nos. 50-315; 50-316

License Nos. DPR-58; DPR-74

Enclosures:

cc w/encls:

1. Notice of Violation

2. Inspection Reports 50-315/98013(DRS); 50-316/98013(DRS)

Don Hafer, Acting Chief

Nuclear Engineer

Douglas Cooper, Plant Manager

Richard Whale, Michigan Public

Service Commission

Michigan Department of

Environmental Quality

Emergency Management

Division, Ml Department

of State Police

David A. Lochbaum, Union

of Concerned

Scientists

DOCUMENT NAME: G:DRS>DCC98013.DRS

To recehre s

of this document, Indtests In the botu 't. ~

lerthout strschmenl/nnctoeure

pi

wth attachment/enctoeure

'N ~ Ho

OFFICE

Rill

6 Rill

Rll

Rill

NAME

DNIssen:jp

Q

GShear ~

BB

ss

JGro

DATE

06/5 /98

06/5/98

064/98

06/ /

OFFICIALRECORD COPY

0

J. Sampson

DDf~M:

Project Mgr., NRR w/encls

C. Paperiello, Rillw/encls

J. Caldwell, Rill w/encls

B. Clayton, Rillw/encls

SRI DC Cook w/encls

DRP w/encls

TSS w/encls

DRS w/encls

RIIIPRR

/en

PUBLIC I

1 w/encls

Docket

le w encls

GREENS