November 5, 1997 I
L 1
L'ICENSEE:<
. FACILITY:
American Electric Power Donald C. Cook Nuclear Plant, Units 1 and 2 SUBJECT
SUMMARY
OF OCTOBER 9, 1997, MEETING ON ANALYSISOF RECIRCULATION SUMP INVENTORY Ir Ill c
On October 9, 1997, NRC staff members met in Rockville, Maryland, with representatives of American Electric Power (AEP). The purpose of the meeting was for AEP to discuss their analysis of recirculation sump inventory to address Item 1 from the September 19, 1997, confirmatory action letter and the October 8, 1997, technical specification (TS) amendment request to revise the minimum quantity of ice in the containment ice condenser.
A list of the meeting participants is attached.
The licensee opened the meeting with a brief review of the discussion from the September 23, 1997, meeting on the same subject.
The discussion then focused on the TS amendment submittal.
Topics included:
conservatisms in the analysis, assumption of no operator action, allowances for sublimation and measurement error, potential increase in sampling frequency, and assumed initial humidity. The use of the material access authorization program (MAAP) code was also discussed including the sensitivity analyses and comparison analyses.
The meeting concluded with the licensee's commitment to provide the MAAP code input listing and a nonproprietary version of Attachment 5 of the TS amendment submittal.
Original signed by:
John B. Hickman, Project Manager Project Directorate III-3 Division of Reactor Projects III/IV Office of Nuclear Reactor Regulation Docket Nos. 50-315 and 50-316 Attachment; List of Meeting Participants
,cc w/att: See next page DISTRIBUTION: See next page DOCUMENT NAME: G:>DCCOOK<CO100997.MTS pwri p vari,,'l p pair,'iillitt~DQ, /)~~i.rfJ)t 4
, IIIlllllllllllllllllllllllllIIIIIIII!II
~
ff
,~ Togecelvo a copy of this document, Indicate In the box: "C" ~ Copy without endosures "E" = Copy viith endosures "N" = No copy OFFICE PD3-3:PM NAME JHickman DATE 11/
97 14 97ii200350 97ii05 PDR ADOCK 050003i5 POR PD3-3:LA E
CBoyle 11/g/97 A '
C S
I I
II Ih ii I'I i
I(
I
(
'I IJ I
E I,
I(
lf I
gf(
J II WJ I
November 5, 1997 LICENSEE:
American Electric Power FACILITY:
Donald C. Cook Nuclear Plant, Units 1 and 2
SUBJECT:
SUMMARY
OF OCTOBER 9, 1997, MEETING ON ANALYSISOF RECIRCULATION SUMP INVENTORY On October 9, 1997, NRC staff members met in Rockville, Maryland, with representatives of American Electric Power (AEP). The purpose of the meeting was for AEP to discuss their analysis of recirculation sump inventory to address Item 1 from the September 19, 1997, confirmatory action letter and the October 8, 1997, technical specification (TS) amendment request to revise the minimum quantity of ice in the containment ice condenser.
A list of the meeting participants is attached.
The licensee opened the meeting with a brief review of the discussion from the September 23, 1997, meeting on the same subject.
The discussion then focused on the TS amendment submittal.
Topics included:
conservatisms in the analysis, assumption of no operator action, allowances for sublimation and measurement error, potential increase in sampling frequency, and assumed initial humidity. The use of the material access authorization program (MAAP) code was also discussed including the sensitivity analyses and comparison analyses.
The meeting concluded with the licensee's commitment to provide the MAAP code input listing and a nonproprietary version of Attachment 5 of the TS amendment submittal.
Original signed by:
John B. Hickman, Project Manager Project Directorate III-3 Division of Reactor Projects III/IV Office of Nuclear Reactor Regulation Docket Nos. 50-315 and 50-316
Attachment:
List of Meeting Participants cc w/att: See next page DISTRIBUTION: See next page DOCUMENT NAME: G:>DCCOOK<CO100997.MTS To receive e copy of this document, Indicate In the box: "C" ~ Copy without enciosures "E" = Copy viith enctosures "N" ~ No copy OFFICE PD3-3:PM E
PD3-3:LA E
NAME JHickman DATE 11/
97 CBoyle 11/g/97
y~f
~,
qAR RECii
~c~
k n
C O
rg Op Yr
~O
+)t**+
UNITED STATES NUCLEAR REGULATORY COIVIMISSION WASHINGTON, D.C. 2055&0001 November 5, 1997 LICENSEE:
American Electric Power FACILITY:
Donald C. Cook Nuclear Plant, Units 1 and 2
SUBJECT:
SUMMARY
OF OCTOBER 9, 1997, MEETING ON ANALYSISOF RECIRCULATION SUMP INVENTORY On October 9, 1997, NRC staff members met in Rockville, Maryland, with representatives of American Electric Power (AEP). The purpose of the meeting was for AEP to discuss their analysis of recirculation sump inventory to address Item 1 from the September'19,
- 1997, confirmatory action letter and the October 8, 1997, technical specification (TS) amendment request to revise the minimum quantity of ice in the containment ice condenser.
A list of the meeting participants is attached.
The licensee opened the meeting with a brief review of the discussion from the September 23, 1997, meeting on the same subject.
The discussion then focused on the TS amendment submittal.
Topics included:
conservatisms in the analysis, assumption of no operator action, allowances for sublimation and measurement error, potential increase in sampling frequency, and assumed initial humidity. The use of the material access authorization program (MAAP) code was also discussed including the sensitivity analyses and comparison analyses.
The meeting concluded with the licensee's commitment to provide the MAAP code input listing,and a nonproprietary version of Attachment 5 of the TS amendment submittal.
John B. Hickman, Project Manager Project Directorate III-3 Division of Reactor Projects III/IV Office of Nuclear Reactor Regulation Docket Nos. 50-315 and 50-316
Attachment:
List of Meeting Participants cc w/att: See next page
J
Indiana Michigan Power Company Donald C.
Cook Nuclear Plant Units 1 and 2
Cco Regional Administrator, Region III U.S. Nuclear Regulatory Commission 801 War renville Road Lisle, IL 60532-4351 Attorney General Department of Attorney General 525 West Ottawa Street
- Lansing, HI 48913 Township Supervisor Lake Township Hall P.O.
Box 818
- Bridgman, HI 49106 Al Blind, Site Vice President Donald C.
Cook Nuclear Plant 1 Cook Place
- Bridgman, MI 49106 U.S. Nuclear Regulatory Commission Resident Inspector's Office 7700 Red Arrow Highway Stevensvi1 1 e, HI 49127 Gerald Charnoff, Esquire
- Shaw, Pittman, Potts and Trowbridge 2300 N Street, NW.
Washington, DC 20037 Mayor, City of Bridgman P.O.
Box 366
- Bridgman, MI 49106 Special Assistant to the Governor Room 1 - State Capitol
- Lansing, MI 48909 Drinking Water and Radiological Protection Division Michigan Department of Environmental guality-3423 N. Hartin Luther King Jr Blvd P.O.
Box 30630, CPH Hailroom
- Lansing, MI 48909-8130 Steve J.
Brewer Indiana Michigan Power Company Nuclear Generation Group 500 Circle Drive
- Buchanan, HI
- 49107, E.E. Fitzpatrick, Vice President Indiana Michigan Power Company Nuclear Generation Group 500 Circle Drive
- Buchanan, MI 49107
MEETING ATTENDEES NRC AND AMERICAN ELECTRIC POWER DISCUSSION OF ANALYSISOF RECIRCULATION SUMP INVENTORY OCTOBER 9, 1997 NRC John Hickman Gail Marcus Richard Lobel Walton Jensen William Long American Electric Power Steve Brewer Jeb Kingseed John Olvera Paul Schoepf Robert Henry (Fauske 8 Associates, Inc.)
Michael Young (Westinghouse)
Union of Concerned Scientists David Lochbaum Inside NRC / Nucleonics Week Liane Kucher Attachment
DISTRIBUTION FOR
SUMMARY
OF OCTOBER 9, 1997, MEETING WITH AMERICAN ELECTRIC POWER Docket File PD III-3 Reading PUBLIC GGrant, Rill OGC ACRS David A. Lochbaum, UCS E-mail w/att 1:
SCollins (SJC1)
FMiraglia (FJM)
GTracy (GMT)
RZimmerman (RPZ)
EAdensam (EGA1)
GMarcus (GHM)
TMartin (SLM3)
RLobel (RML)
WJensen (WLJ)
WLong (WOL)
V
~.