XN-NF-82-35 SUPPLEMENT t DONALD C.

COOK UNIT 2 CYCLE 4 LIMITING BREAK LOCA-ECCS ANALYSIS USING EXEM/PWR MOTICE THE ATTACHED FILES ARE OFFICIAL RECORDS OF THE DIVISION OF DOCUMENT CONTROL.

THEY HAVE BEEN CHARGED TO YOU FOR A LIMITEDTIME PERIOD AND MUST BE RETURNED TO THE RECORDS FACILITY BRANCH 016.

PLEASE DO NOT SEND DOCUMENTS CHARGED OUT THROUGH THE MAIL. REMOVALOF ANY PAGE(S) FROM DOCUMENT FOR REPRODUCTION MUST BE REFERRED TO FILE PERSONNEL. g g /Q u/~p/e~h DEADLINERETURN DATE NOVEMBER 19S2 RICHLAND, NA 99352 RECORDS FACILITYBRANCH EQQN NUCLEAR CQIVIPAN+,I~o.

~

~

g

E)5(ON NUCLEAR COMPANY,Inc.

I 2181 Hom Rapids Road P. D Box 13g Bidiland, 5'asliington gg352'hone:

(509) 375-8100 Telex: l5-2878 November 24, 1982 GFO:091:82 Donal d C.

Cook Nuc 1 ear P lant Unit 2 Docket No. 50-Btl Slg License No.

DPR-74 Transmittal of XN-NF-82-35, Supp.

1, "Donald C.

Cook Unit 2 Cycle 4 Limiting Break LOCA-ECCS Analysis Using EXEM/PWR" Mr. Darrell G. Eisenhut, Director Division of Licensing Office of Nuclear Reactor Requlation U. S. Nuclear Regulatory Commission Washington, D.

C.

20555

Dear Mr. Eisenhut:

This letter transmits thirty-five (35) copies of the subject report.

Indiana E Michigan Electric Company will be referencing this report in future correspondence with you regarding Cycle 4 operation.

Please contact Dr. Juan Castresana of American Electric Power

Company, telephone (212) 440-9282, if you have questions or comments regarding this transmittal.

Si

erely, GFO:gf Attachment (35)

As noted CC:

Mr. D. L. Wigginton (USNRC)

Dr. J. I. Castresana (AEP)

G. F. Owsley Reload Fuel Lice sing 7olo 82ii290369 82ii24 PDR ADDC~ 0~000~ i6 P