Text
R GULAT3RY INFORRATIOV'ISTRIBUTION SYSTEM (RIDS)
ACCESSIOV'9R:8111170264 DOC ~ DATE,. 81/11/11 NOTARIZED: ~ NO FACILCSQ'15 Donald Cook Nuclear~ Po~er~ Planti Unit ii Indiana 50;,316 Donal d
"~ "ook, Nucl ear i Power" Pl antr Uni t 2'g Indiana AUTHLN AiRE AurHQR AFFILIATION SALOVEiYiG,P; Indiana~
0 'lichi gan Kllectri c Co, RECIP, VA1="I RE "tIPZENT AFFILIIATlOV DENT3>>r 9;R ~
Office. of Vuclear Reactor-Regulationi Directors'OCKET' 05090315 85 P003 SUBJ=CT:: Forwards reviseo lech Soecs 3.7.8 8 0.7.8 re, surve,illancei r quirenents for safety-related snu'ooer s in response to 3G Ei senhut 801 l2V l.tr ~
r, 2W DISTR'IBJTI DN C3DEI:
A001S COP I 8
RECEtI VED: LiTR ANCl (
SI ZE'o:
TIKL=l:.3eneral Distribution fori af teri Issuance of Operating.
cense VOTES:.IXE: 5~ cool s al 1
materi al, ICE:-3i cori es al 1
materi el, 05090315 05090316'ECI
~I=NT'9<
CODE/HAM"1 ACTION OR3i oi BC; 01.
INTERN ALc EL'3<<
VRR'/DHF S DEP Y08 GRAB 04 COPIES LT I'R ENCL'3 13 1
0 1
1 1
Q 1
1 RECIPiENT ID CODE/>>A.lE I E E'RR!DL; DIR VRR/DSI/RA8 06 COPIES LTTR<
NCL' 2
1 1
1 1
EXTERNALr.
ACRS NR "i PORE Vris 09.
Q 7I 16 16 1
1 1
1 LPDRI
>>SIC.
03.
05 1
1-1 1
H~
c/
TOTAL >>UMBER~ OF COPIES'EQUIRED:: LiTTR ENCL;
C ~
INDIANA II MICHIGAN ELECTRIC COMPANY P. O.
BOX 18 BO WI IN G G R E EN STATION NEW YORK, N. Y. 10004 November ll, 1981 AEP:NRC:0504 Donald C.
Cook Nuclear Plant Unit Nos.
1 and 2
Docket Nos.
50-315 and 50-316 License Nos.
DPR-58 and DPR-74 REVISED SAFETY-RELATED SNUBBER SURVEILLANCE Mr. Harold R. Denton, Director Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, D.C.
20555 egjjjp~
'gg Qupg~~Qrc4II
's
Dear Mr. Denton:
This letter and its attachments respond to Mr. D.
G. Eisenhut's letter of November 20, 1980 regarding Technical Specification surveillance requirements for safety-related snubbers.
Attachment Nos.
1 and 2 contain the revised Technical Specification pages for D. C. Cook Unit Nos.
1 and 2, respectively.
As noted in the footnotes on page 3/4 7-23 of the Attachment to Mr.
Eisenhut's letter, the value "c" used in the determination of the number of snubbers to be tested was intended for use in plants with large numbers of safety-related snubbers
( +500).
Since each Unit of the Cook Plant utilizes approximately 100 safety-related
- snubbers, those portions of the
'sample'echnical Specifications referring to "c" in Mr.
Eisenhut's letter have been deleted.
Similarly, since mechanical snubbers are not used in safety-related systems at Cook Plant, the
'sample'pecifications have been modified. to refer only to hydraulic snubbers.
Other minor modifications have been made to the
'sample'pecifications to accommodate insertion into the existing Cook Plant Specifications.
The Technical Specifications contained in Attachment No.
1 reference Specification 4.0.5 which does not exist in the present Unit No.
1 Specifications.
- However, we plan to submit in the near future revisions.'o the Unit No.
1 Technical Specifications which will incorporate a Specification 4.0.5 very similar to the existing Unit No.
2 Specification.
8! g
)gyp-p OCR Oso lgi
~DR gg ~<+ 8f g"
<<Oexs I'Dp
Mr. Harold R. Denton AEP: NRC: 0504 The proposed Technical Specifications contained herein have been reviewed by the Plant Nuclear Safety Review Committee and the American Electric Power Service Corporation Nuclear Safety Design Review Committee.
As a result of these reviews, it has been concluded that implementation of the proposed Technical Specifications will not in any way endanger the health and safety of the general public.
Indiana 6 Michigan Electric Company interprets 10 CPR 170.22 such that no fee be required for this submittal.
This document has been prepared following Corporate procedures which incorporate a reasonable set of controls to insure its accuracy and completeness prior to signature by the undersigned.
V. ry truly yours, G. P. Mal e
Vice Pre de t
/emc cc:
John E. Dolan - Columbus R. C. Callen G. Charnoff R.
W. Jurgensen D. V. Shaller Bridgman Joe Williams, Jr.
NRC Region IIIResident Inspector Bridgman