ML17333A302

From kanterella
Jump to navigation Jump to search
Forwards Insp Repts 50-315/95-13 & 50-316/95-13 on 951205- 960116 & Notice of Violation
ML17333A302
Person / Time
Site: Cook  
Issue date: 02/08/1996
From: Kropp W
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To: Fitzpatrick E
INDIANA MICHIGAN POWER CO. (FORMERLY INDIANA & MICHIG
Shared Package
ML17333A303 List:
References
NUDOCS 9602200317
Download: ML17333A302 (8)


See also: IR 05000315/1995013

Text

CATEGORY 2

+IV

NOTES:

REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)

'v

-ACCESSION NBR:9602200317

DOC.DATE: 96/02/08

NOTARIZED: NO

DOCKET

g.

ACIL:50-315 Donald C.

Cook Nuclear

Power Plant, Unit 1, Indiana

M

05000315

50-316 Donald C.

Cook Nuclear

Power Plant, Unit 2, Indiana

M

05000316

AUTH.NAME

AUTHOR AFFILIATION

KROPP,H.J.

Region

3 (Post

820201)

RECIP.NAME

RECIPIENT AFFILIATION

FITZPATRI"K,E.

Indiana Micnigan Power

Co. (formerly Indiana

& Michigan Ele

SUBJECT:

Forwards

insp repts

50-315/95-13

6 50-316/95-13

on 951205-

960116

& notice of violation.

DISTRIBUTION CODE:

IE01D

COPIES

RECEIVED:LTR

ENCL

SIZE:

TITLE: General

(50 Dkt)-Insp Rept/Notice of Violation Response

RECIPIENT

ID CODE/NAME

PD3-1

PD

INTERNAL: AEOD/DEIB

AEOD/TTC

PX53.

CENTER

CH HHFB

NRR/DRPM/PERB

OE DIR

RGN3

FILE

01

~i

ERNAL: LITCO BRYCE,J

H

NRC

PDR

'I

COPIES

LTTR ENCL

1

1

1

1

1

1

1

1

1

1

1

1

1

1

'1

1

1

1

1

1

RECIPIENT

ID CODE/NAME

HICKMAN,J

AEOD/SPD/RAB

DEDRO

NRR/DISP/PIPB

NRR/DRPM/PECB

NUDOCS-ABSTRACT

OGC/HDS2

NOAC

COPIES

LTTR ENCL

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

NOTE TO ALL "RIDS" RECIPIENTS:

PLEASE HELP US TO REDUCE WASTE!

CONTACT THE DOCUMENT CONTROL DESK,

ROOM OWFN SD-5(EXT. 415-2083)

TO ELIMINATE YOUR NAME FROM

DISTRIBUTION LISTS

FOR

DOCUMENTS YOU DON AT NEEDI

TOTAL NUMBER OF COPIES

REQUIRED:

LTTR

18

ENCL

18

February 8,

1996

,8

Mr. E.

E. Fitzpatrick

Senior Vice President

Nuclear Generati'on

Indiana Michigan Power

Company.

1 Riverside

Plaza

Columbus,

OH

43216

SUBJECT:

INTEGRATED INSPECTION

REPORT 50-315/316-95013 (DRP)

AND NOTICE OF VIOLATION-

Dear Mr. Fitzpatrick:

This refers to the routine safety inspection

conducted

by Messrs.

B. Bartlett,

D. Hartland,

C. Orsini,

R. Paul,

B. Fuller,

and

N. Shah of this office from

December

5,

1995,

through January

16,

1996.

The inspection

included

a review

of activities at your Donald C.

Cook Nuclear Plant,

Units

1 and 2.

At the conclusion of the inspection,

the findings were discussed

with those

members of your staff identified in the enclosed report.

Based

on the results of this inspection,

the

NRC has determined that two

violations of NRC requirements

occurred.

The violations are cited in the

enclosed

Notice of Violation (Notice)

and the circumstances'surrounding

them

are described

in detail in the subject inspection report.

The violations are

of concern

because

in one case

a Technical Specification requirement for. the

diesel

generators

was not properly implemented,

and in the other case there

was

a failure to test safety-related

equipment

under conditions

assumed

in

design basis

documents.

We are concerned

that during this inspection there were several

issues

identified which pertained to implementation of technical specification

requirements

in the area of surveillance testing.

There were also continuing

performance

issues

identified in the work control process,

two of which

pertained

to post maintenance

testing.

You.are required to respond to this letter and should follow',the instructions

specified in the enclosed

Notice when preparing your response.

In your

response,

you should document the specific actions

taken -and any additional

actions

you plan to- prevent recurrence.

Your response

may reference

or

include previous docketed

correspondence, if the correspondence

adequately

96022003i7

960208

PDR

ADOCK 050003i5

G

PDR

4>geog

Areas examined during the inspection

are identified in the report.

Within

these

areas,

the inspection consisted of,a selective

examination of procedures

and representative

records,

observations,

and interviews with personnel.

This

report represents

an integra

ad product of a number of inspections

conducted

during the inspection period.

The summary contained

in the report provides

an

overview of our assessment

of your performance

in the functional

areas

inspected.

E.

E. Fitzpatrick

addresses

the required response.

After reviewing your response

to this

Notice, including your -proposed corrective actions

and the results of future

inspections,

the

NRC will determine whether further

NRC enforcement

action is

necessary

to ensure

compliance with NRC regulatory requirements.

In-accordance

with 10 CFR 2.790 of the NRC's "Rules of Practice,"

a copy of

this letter, its enclosures,

and your response will be placed in the

NRC

Public Document

Room (PDR).

To the extent possible,

your response

should not

include any personal

privacy, propriety, or safeguards

information so that it

can

be placed in the

PDR without redaction.

The responses

directed

by this letter and the accompanying

Notice are not

subject to the clearance

procedures

of the Office of Management

and Budget

as

required

by the Paperwork Reduction Act of 1980,

PL 96-511.

We will gladly discuss

any questions

you have concerning this inspection.

Sincerely,

/s/W. J.

Kropp, Chief

W. J.

Kropp, Chief

Reactor Projects

Branch

3

Docket No. 50-315

Docket No. 50-316

Enclosures:

1.

Notice of Violation

'.

Inspection

Report

No.

50-315/95013 (DRP);

50-316/95013 (DRP)

cc w/encl:

A. A. Blind, Site Vice President

John

Sampson,

Plant Manager

James

R. Padgett,

Michigan Public

Service

Commission

Michigan Department of

Public Health

Distribution:

Docket File w/encl

PUBLIC IE-01 w/encl

OC/LFDCB w/encl

SRI D.

C.

Cook w/encl

RMB/FEES w/o encl

R:iinsprptsipowersicookidcc95013.drp

DRP w/encl

RIII PRR w/encl

D.

C. Cook,

PM,

NRR w/encl

IPAS (E-Mail) w/encl

A. B. Beach,

w/encl

Sea httachod Coneurroaeo)

o rocotw a copy of this doc+et,

tadtcato fa tho hoa

C

~ Copy>>lthout attach/oocl

E

Copy ulth attach/oocl

N>>

No co

OFFICE

NAME

DATE

RIII

Jackiw d

02/

/96

RIII

Caniano

02/

/96

OFFICIAL RECORD

COPY

E.

E. Fitzpatrick

In accordance

with 10 CFR 2.790 of the NRC's "Rules of Practice,"

a copy of

this letter, its enclosures,

and your response will be placed in the

NRC

Public Document

Room (PDR).

To the extent possible,

your response

should not

include any personal

privacy, propriety,

or safeguards

information so that it

can

be placed in the

PDR without redaction.

The responses

directed

by this letter and the accompanying

Notice are not

subject to the clearance

procedures

of the Office of Management

and Budget

as

required

by the Paperwork Reduction Act of 1980,

PL 96-511.

We will gladly discuss

any questions

you have concerning this inspection.

Sincerely,

Docket No. 50-315

Docket No. 50-316

W. J.

Kropp, Chief

Reactor Projects

Branch

3

Enclosures:

1.

Notice of Violation

2.

Inspection

Report

No.

50-315/95013(DRP);

50-316/95013 (DRP)

cc w/encl:

A. A. Blind, Site Vice President

John

Sampson,

Plant Hanager

James

R. Padgett,

Michigan Public

Service

Commission

Michigan Department of

Public Health

'b

Docket File w/encl

PUBLIC IE-Ol w/encl

OC/LFDCB w/encl

SRI D. C.

Cook w/encl

RHB/FEES w/o encl

DRP w/encl

RIII PRR w/encl

D.

C. Cook,

PH,

NRR w/encl

IPAS (E-Mail) w/encl

A. B. Beach,

w/encl

R:iinsprptsipowersicookidcc95013.drp

To vocaiva a copy of this docent,

isdicata ia tho hoa

C

Copy without attach/oacl

P i Copy with attach/aacl

N

No c

OFFICE

RIII

RIII

NANE

DATE

Jackiw

02

7

96

"

Caniano

02

96

OFFICIAL RECORD

COPY

J,

UNITED STATES

NUCLEAR REGULATORYCOMMISSION

REGION III

801 WARRENVILLEROAD

USLE. ILLINOIS60532-.4351

February 8,

1996

Mr. E.

E. Fitzpatrick

Senior Vice President

Nuclear Generation

Indiana Michigan Power

Company

1 Riverside

Plaza

Columbus,

OH

43216

SUBJECT:

INTEGRATED INSPECTION

REPORT 50-315/316-95013 (DRP)

AND NOTICE OF VIOLATION

Dear Mr. Fitzpatrick:

This refers to the routine safety inspection

conducted

by Messrs.

B. Bartlett,

D. Hartland,

C. Orsini,

R. Paul,

B. Fuller,

and

N. Shah of this office from

December

5,

1995,

through January

16,

1996.

The inspection

included

a review

of activities at your Donald C. Cook Nuclear Plant, Units

1 and 2.

At the conclusion of the inspection,

the findings were discussed

with those

members of your staff identified in the enclosed

report.

Areas

examined during the inspection

are identified in the report.

Within

these

areas,

the inspection consisted

of a selective

examination of procedures

and representative

records,

observations,

and interviews with personnel.

This

report represents

an integrated

product of a number of inspections

conducted

during the inspection period.

The summary contained

in the report provides

an

overview of our assessment

of your performance

in the functional

areas

inspected.

Based

on the results of this inspection,

the

NRC has determined that two

violations of NRC requirements

occurred.

The violatioIIs are cited in the

enclosed

Notice of Violation (Notice)

and the circumstances

surrounding

them

are described

in detail in the subject inspection report.

The violations are

of concern

because

in one case

a Technical Specification requirement for the

diesel

generators

was not properly implemented,

and in the other

case

there

was

a failure to test safety-related

equipment

under conditions

assumed

in

design basis

documents.

We are concerned

that during this inspection there were several

issues

identified which pertained

to implementation of technical specification

requirements

in the area of surveillance testing.

There were also continuing

performance

issues

identified in the work control process,

two of which

pertained

to post maintenance

testing.

You are required to respond to this letter and should follow the instructions

specified in the enclosed

Notice when preparing your response.

In your

response,

you should document the specific actions

taken

and

any additional

actions you plan to prevent recurrence.

Your response

may reference

or

include previous docketed

correspondence, if the correspondence

adequately

E.

E. Fitzpatrick

addresses

the required

response.

After reviewing your response

to this

Notice, including your proposed corrective 'actions

and the res '.ts of future

inspections,

the

NRC will determine

whether further

NRC enforcement

action is

necessary

to ensure

compliance with NRC regulatory requirements.

In accordance

with 10 CFR 2.790 of the NRC's "Rules of Practice,"

a copy of

this letter, its enclosures,

and your response will be placed in the

NRC

Public Document

Room (PDR).

To the extent possible,

your response

should not

include

any personal

privacy, propriety, or safeguards

information so that it

can

be placed in the

PDR without redaction.

The responses

directed

by this letter and the accompanying

Notice are not

subject to the clearance

procedures

of the Office of Hanagement

and Budget

as

required

by the Paperwork Reduction Act of 1980,

PL 96-511.

We will gladly discuss

any questions

you have concerning this inspection.

Sincerely,

j/

(

W. J.

Kropp, Chief

Reactor Projects

Branch

3

Docket No. 50-315

Docket No. 50-316

Enclosures:

1.

Notice of Violation

2.

Inspection

Report

No.

50-315/95013 (DRP);

50-316/95013(DRP)

cc w/encl:

A. A. Blind, Site Vice President

John

Sampson,

Plant Hanager

James

R. Padgett,

Hichigan Public

Service

Commission

Hichigan Department of

Public Health