R.IC)R.I EY' ACCELERATED RIDS PROCESSING)

REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)

ACCESSION NBR:9512260340 DOC.DATE-95/12/19 NOTARIZED: YES DOCKET N

FACIL:50-315 Donald C.

Cook Nuclear Power Plant, Unit 1, Indiana M

05000315 AUTH.NAME AUTHOR AFFILIATION FITZPATRICK,E.

Indiana Michigan Power Co.

(formerly Indiana 6 Michigan Ele RECIP.NAME RECIPIENT AFFILIATION Document Control Branch (Document Control Desk)

SUBJECT:

Requests that Westinghouse Rept SG-95-11-002, "Evaluation of Far Field Residual Stresses in Hybrid Expansion Joint (HEJ)

Sleeved Tubes," submitted by WPSC 951108 ltr be included by ref on facility 950804 SG HEJ tube repair application.

DISTRIBUTION CODE:

AOOID COPIES RECEIVED:LTRj ENCL 0 SIZE:

TITLE: OR Submittal:

General Distribution NOTES RECIPIENT ID CODE/NAME PD3-1 LA HICKMAN,J INTERNAL ILE CENTE C /HICB NRR/DSSA/SRXB OGC/HDS2 EXTERNAL: NOAC COPIES LTTR ENCL RECIPIENT ID CODE/NAME PD3-1 PD NRR/DE/EMCB NRR/DSSA/SPLB NUDOCS-ABSTRACT NRC PDR COPIES LTTR ENCL NOTE TO ALL"RIDS" RECIPIENTS:

PLEASE HELP US TO REDUCE iVASTE!CONTACI THE DOCUhlENT CONTROL DESK, ROOhl PI -37 (EXT. 501-2083 ) TO EL I hl I NATE YOUR. 4AilE FROil DISTRIBUTIONLISTS FOR DOCl 'MENTS YOU DON"I'EED!

TOTAL NUMBER OF COPIES REQUIRED:

LTTR 12 ENCL 11

Indiana Michigan Power Company PO Box 16631 Coiumbus, OH 43216 lNQIAMA NICHIGAN PWM December 19, 1995 AEP:NRC'1129K Docket Nos.:

50-315 U. S. Nuclear Regulatory Commission ATTN:

Document Control Desk Washington, D.

C.

20555 Gentlemen:

Donald C.

Cook Nuclear Plant Unit 1 TECHNICAL SPECIFICATION CHANGES TO ALLOW FOR REPAIR OF HYBRID EXPANSION JOINT (HEJ)

SLEEVED STEAM GENERATOR TUBES ADDITIONALINFORMATION The purpose of this letter is to amend our unit 1 steam generator HEJ sleeved tube repair application, as requested by your staff.

We were present for the Wisconsin Power Company presentation to NRR regarding the "Evaluation of Far Field Residual Stress in HEJ Sleeved Tubes" on January 8, 1995, and agree that the Westinghouse evaluation report developed for EPRI is a useful supplement to our application submitted in AEP:NRC:1129E dated August 4,

1995.

Therefore we do hereby request that this report SG-95-11-002, "Evaluation of Far Field Residual Stresses in HEJ Sleeved Tubes",

submitted by Wisconsin Public Service by their letter NRC-95-117, dated November 8,

1995, be included by reference on our docket.

Sincerely, E.