P RIORITY 1

ACCELERATED RIDS PROCI'.SSI4G)

REGULATORY XNFORMATION DISTRIBUTXON SYSTEM (BIDS)

ACCESSION NBR:9512110187 DOC.DATE: 95/12/01 NOTARIZED: YES DOCKET FACIL:50-315 Donald C.

Cook Nuclear Power Plant, Unit 1, Xndiana M

05000315 AUTH.NAME AUTHOR AFFILIATION FITZPATRICK,E.

Indiana Michigan Power Co.

(formerly Indiana S Michigan Ele RECIP.NAME RECXPIENT AFFILIATION P

Document Control Branch (Document Control Desk} ~~~-

SUBZECT: Forwards proprietary

& nonproprietary presentation matl from 950810 meeting wiAEPSC,NRC

& Westrnghouse re i.>p/}I application of revised pressure boundary limits for hybrid expansion joint sleeved tubes. Proprietary matl withheld.

DISTRIBUTION CODE:

AP01D COPIES RECEIVED LTR ENCL SXZE:

TITLE: Proprietary Review Distribution - Pre Operating License Operating NOTES:

RECXPXENT XD CODE/NAME PD3-1 LA HICKMAN,J COPIES LTTR ENCL 1

1 1

1 RECIPIENT ID CODE/NAME PD3-1 PD COPIES LTTR ENCL 1

1 EXTERNAL: NRC PDR 01 1

1 OGC/HDS2 ppP 1

0 D

N iNOTE TO ALL"RIDS" RECIPIENTS:

PLEASE HELP US TO REDUCE KV'iSTE! COh,'TACT TIIE DOCL'iIE4TCONTROL DESK, ROOA I P I -37

<EAT. 504-90S3

) TO I;LIMIi%TE YOI'R iAMLf PRO.'i!

DISTRIIIVI'IOY, LIS'I'S I:OR DOCI:41Ei'I'S YOI: DON"I'!9 I D!

TOTAL NUMBER'OF COPXES REQUIRED:

LTTR 6

ENCL

Indiana Michigan Power Company PO Box 16631 Columbus, OH 43216 IRON NAl NICHIGAN

&GISM December 1,

1995 Docket Nos.:

50-315 AEP'NRC'1129J U.

S. Nuclear Regulatory Commission ATTN:

Document Control Desk Washington, D.

C.

20555 Gentlemen:

Donald C. Cook Nuclear Plant Unit 1 TECHNICAL SPECIFICATION CHANGE FOR HYBRID EXPANSION JOINT (HEJ)

SLEEVED GENERATOR TUBES REQUEST FOR ADDITIONALINFORMATION (RAI)

The purpose of this letter is to transmit copies of Westinghouse WCAP-14513 and

14514, "Presentation Materials from the August 10, 1995 Meeting with American Electric Power Service Corporation, U.S.
NRC, and Westinghouse Concerning Application of the Revised Pressure Boundary Limits for HEJ Sleeved Generator Tubes."

The proprietary and non proprietary versions of the presentation material are contained in Attachment 1.

Attachment 2

contains the affidavit and the justification for withholding information from public disclosure.

Sincerely, E.

E. Fitzp trick Vice President pit Attachments CC; A. A. Blind G. Charnoff H. J. Miller NFEM Section

.rhie'~>

NRC Resident Inspector

- Bridgman J.

R. Padgett i)0034 9512110187 951201 PDR ADOCK 05000315 P