ML17332A916
| ML17332A916 | |
| Person / Time | |
|---|---|
| Site: | Cook |
| Issue date: | 08/08/1995 |
| From: | Fitzpatrick E INDIANA MICHIGAN POWER CO. (FORMERLY INDIANA & MICHIG |
| To: | NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM) |
| References | |
| AEP:NRC:120BL, NUDOCS 9509140020 | |
| Download: ML17332A916 (9) | |
Text
PRIORITY (ACCELERATED RIDS PROCESSING)
REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)
ACCESSION NBR:9509140020 DOC.DATE: 95/08/08 NOTARIZED: NO DOCKET g FACIL:50-315 Donald C.
Cook Nuclear Power Plant, Unit 1, Indiana M
05000315 50-316 Donald C.
Cook Nuclear Power Plant, Unit 2, Indiana M
05000316 AUTH.NAME AUTHOR AFFILIATION FITZPATRICK,E.
(formerly Indiana
& Michigan Ele RECIP.NAME RECIPIENT AFFILIATION Document Control Branch (Document Control Desk)
I
SUBJECT:
Provides notification of spill of ethylene glycol monobutyl ether to ground.
0 DISTRIBUTION CODE:
C001D COPIES RECEIVED:LTR ENCL SIZE:
TITLE: Licensing Submittal: Environmental Rept Amdt elated Correspondence NOTES RECIPIENT ID CODE/NAME D
INTERNAL: F EaGENSB 0 1 RGN3 DRSS/RPB EXTERNAL LITCO AKERS i D NRC PDR COPIES
'LTTR ENCL 1
1 1
1 1
1 1
1 1
1 RECIPIENT ID CODE/NAME HICKMAN;J OGC/HDS2 NOAC COPIES LTTR ENCL 1
1 1
0 1
1 D
N NOTE TO ALL "RIDS" RECIPIENTS:
PLEASE HELP US TO REDUCE WASTE!
CONTACT THE DOCUMENT CONTROL
- DESK, ROOM OWFN 5D8 (415-2083)
TO ELIMZNATE YOUR NAME FROM DISTRIBUTION LISTS FOR DOCUMENTS YOU DON'T NEED!
TOTAL NUMBER OF COPIES REQUIRED:
LTTR 8
ENCL 7
Indiana Michigan Power Company P.O. Box 16631 Cofumbus, OH 43216 August 8, 1995 AEP:NRC:1208L Docket Nos.:
50-315 50-316 U.
S. Nuclear Regulatory Commission ATTN:
Document Control Desk Washington, D.
C.
20555 Gentlemen:
Donald C.
Cook Nuclear Plant Units 1 and 2
SPILL NOTIFICATION The attached notifications are forwarded for your information pursuant to Appendix B of the Donald C.
Cook Nuclear Plant Environmental Technical Specifications.
The subject of these notifications concern a spill of ethylene glycol monobutyl ether (high expansion foam from a fire suppression system) to the ground, and a spill of transformer oil to the catch basin and the ground.
Should you have any questions or concerns regarding this notification, please contact Walter T. MacRae at 614-223-2019.
gf~pmQ E.
E. Fitzpatrick Vice President pit Attachment CC:
A. A. Blind G. Charnoff H. J. Miller NFEM Section Chief NRC Resident Inspector
- Bridgman J.
R. Padgett
,%An,w 9509140020 950808 PDR ADOCK 05000315
. P PDR
ATTACHMENTS TO AEP'NRC:1208L ETHYLENE GLYCOL MONOBUTYL ETHER SPILL NOTIFICATION TRANSFORMER OIL SPILL NOTIFICATION
Indiana Michigan Power Company Cook Nuclear Plant One Cook Place Brjdgman. Ml 49106 616 465 5901 INDIANA NICHIGAN.
POWER Mr. Fred Morley, District Supervisor Surface Water Quality Division Michigan Department of Natural Resources 621 North Tenth Street P.O.
Box 355 Plainwell, MI 49080 August 24, 1995 Re:
D.C.
Cook Nuclear Plant==-
Ethylene Glycol Monobutyl Ether Spill Notification NPDES Permit No. MI0005827
Dear Mr. Morley:
The following notification is being performed per NPDES Permit MI0005827, Part II.
Section A.6 '
Spill Notification.
The spill was previously reported via a telephone call to Mr. Greg Danneffel of the Michigan DNR Plainwell office at 4:00 p.m.
on August 16, 1995.
The spill occurred at approximately 3:30 p.m.
on August:
15, 1995 when a lightning strike caused a
spurious discharge of the fire suppression system at an on site warehouse.
.An estimated 36.3 gal. of High Expansion Foam (see attached MSDS) containing 104 lbs. of ethylene glycol monobutyl ether mixed with fire suppression water reached the ground.
No remediation of the surrounding soil was performed.
We are undertaking an investigation to determine actions to prevent future spill of this nature.
If you have any questions
. or require further information, please contact me at.
(616) 466-2546.
Sincerely,
/
C('- ~i've Diane M.
t gerald Environmental, Safety
& Health Superintendent,
I certify under penalty of law that I have personally examined and am familiar with the information submitted on this and all attached documents; and based on my incpxiry of those individuals immediately responsible for obtaining the information, I believe the submitted information is true, accurate and complete.
I am aware,.
that there are significant penalties for submitting false information, including the possibility of fine and imprisonment.
P.d.
A. A. Bli d Site Vice President c:
Thomas Leep MDNR Larry Pointer MDNR
Indiana Michigan Power Company Cook Nuclear Plant One Cook Place Sridgman. Ml 49106 416 465 5901 Mr. Fred Morley, District Supervisor Surface Water Quality Division Michigan Department of Natural Resources 621 North Tenth Street P.O.
Box 355 Plainwell, MI 49080 PP
~
INDIANA NICHIGilLN POWER August 24, 1995 Re:
Cook Nuclear Plant Transformer Oil Spill Notification NPDES Permit No. MI0005827
Dear Mr. Morley:
The following notification is being performed per NPDES Permit MI0005827, Part II.
Section A.6.,
Spill Notification.
The spill was previously reported via telephone calls to the Michigan DNR PEAS Operator 32 at 4:45 a.m.
on August 20, 1995 and Ms. Lorraine Thomas of the Environmental
Response
Division at 2:00 p.m.
on
'August 21, 1995.
The spill occurred at 00:49 a.m.
on August 20, 1995 when the Cook Plant, Unit 1 Main Transformer experienced a
phase to phase internal arc
- over, which caused a
catastrophic failure;of the transformer.
Approximately 600 gallons of non-PCB mineral oil (Ultravolt 60) were
- released, of which 50 gallons were spilled to the ground surrounding the concrete transformer catch basin.
Per
- design, the bulk of the spill went via the bermed containment area to an oil/water separator where it is being recovered.
Approximately 10 cubic yards of oil contaminated soil was removed.
The soil was removed to a layer where there was no visible contamination or odor. Oil-Dry was used to clean up stains on the asphalt'.
and concrete, and the steel surfaces were wiped down with absorbents.
No oil was spilled to Lake Michigan, or reached the groundwaters of the State.
If you have any questions or require further information, please contact me at. (616) 466-2546.
Sincerely,
&,(.-..t!)=,
Diane M. Fitzgerald Environmental, Safety
& Health Superintendent
I certify under penalty of law that I have personally examined and am familiar with the information submitted on this and all attached documents; and based on my inquiry of those individuals immediately responsible for obtaining the information, I believe the submitted information is true, accurate and complete.
I am-aware.
that there are significant penalties for submitting false information, including the possibility of fine and.
imprisonment.
.Pg A. A. B1 nd Site Vice President co Thomas Leep - MDNR Larry Pointer MDNR Lorraine Thomas MDNR =.
0 V
~ ~
f